Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Echo Res Pract ; 11(1): 14, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38825684

RESUMEN

BACKGROUND: Echocardiography is widely used to evaluate left ventricular (LV) diastolic function in patients suspected of heart failure. For patients in sinus rhythm, a combination of several echocardiographic parameters can differentiate between normal and elevated LV filling pressure with good accuracy. However, there is no established echocardiographic approach for the evaluation of LV filling pressure in patients with atrial fibrillation. The objective of the present study was to determine if a combination of several echocardiographic and clinical parameters may be used to evaluate LV filling pressure in patients with atrial fibrillation. RESULTS: In a multicentre study of 148 atrial fibrillation patients, several echocardiographic parameters were tested against invasively measured LV filling pressure as the reference method. No single parameter had sufficiently strong association with LV filling pressure to be recommended for clinical use. Based on univariate regression analysis in the present study, and evidence from existing literature, we developed a two-step algorithm for differentiation between normal and elevated LV filling pressure, defining values ≥ 15 mmHg as elevated. The parameters in the first step included the ratio between mitral early flow velocity and septal mitral annular velocity (septal E/e'), mitral E velocity, deceleration time of E, and peak tricuspid regurgitation velocity. Patients who could not be classified in the first step were tested in a second step by applying supplementary parameters, which included left atrial reservoir strain, pulmonary venous systolic/diastolic velocity ratio, and body mass index. This two-step algorithm classified patients as having either normal or elevated LV filling pressure with 75% accuracy and with 85% feasibility. Accuracy in EF ≥ 50% and EF < 50% was similar (75% and 76%). CONCLUSIONS: In patients with atrial fibrillation, no single echocardiographic parameter was sufficiently reliable to be used clinically to identify elevated LV filling pressure. An algorithm that combined several echocardiographic parameters and body mass index, however, was able to classify patients as having normal or elevated LV filling pressure with moderate accuracy and high feasibility.

3.
Eur Heart J Cardiovasc Imaging ; 25(4): 539-547, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37976177

RESUMEN

AIMS: Permanent pacemaker (PM) implantation is common after transcatheter aortic valve implantation (TAVI). Left ventricular mechanical dispersion (MeDi) by speckle tracking echocardiography is a marker of fibrosis that causes alterations in the conduction system. We hypothesized that MeDi can be a predictor of the need for PM implantation after TAVI. METHODS AND RESULTS: Consecutively, 200 TAVI patients were enrolled. Transthoracic echocardiography and electrocardiography examinations were recorded before TAVI to evaluate global longitudinal strain (GLS), MeDi, and conduction disturbances. PM implantation information was obtained 3 months after TAVI. Patients were stratified into PM or no PM group. Mean age was 80 + 7 years (44% women). Twenty-nine patients (16%) received PM. MeDi, QRS duration, existence of right bundle branch abnormality (RBBB), and first-degree atrioventricular (AV) block were significantly different between groups. MeDi was 57 ± 15 ms and 48 ± 12 ms in PM and no PM groups, respectively (P < 0.001). In multivariate analysis, MeDi predicted the need for PM after TAVI independently of GLS, QRS duration, RBBB, and first-degree AV block [odds ratio (OR): 1.73, 95% confidence interval (CI): 1.22-2.45] with an area under the curve (AUC) of 0.68 in receiver operating characteristic (ROC) curves. Moreover, RBBB was an independent predictor of PM need after TAVI (OR: 8.98, 95% CI: 1.78-45.03). When added to RBBB, MeDi had an incremental predictive value with an AUC of 0.73 in ROC curves (P = 0.01). CONCLUSION: MeDi may be used as an echocardiographic functional predictor of the need for PM after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Bloqueo Atrioventricular/etiología , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos
5.
Cardiovasc Ultrasound ; 21(1): 19, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37833731

RESUMEN

BACKGROUND: Measurement of the left ventricular outflow tract diameter (LVOTd) in echocardiography is a common source of error when used to calculate the stroke volume. The aim of this study is to assess whether a deep learning (DL) model, trained on a clinical echocardiographic dataset, can perform automatic LVOTd measurements on par with expert cardiologists. METHODS: Data consisted of 649 consecutive transthoracic echocardiographic examinations of patients with coronary artery disease admitted to a university hospital. 1304 LVOTd measurements in the parasternal long axis (PLAX) and zoomed parasternal long axis views (ZPLAX) were collected, with each patient having 1-6 measurements per examination. Data quality control was performed by an expert cardiologist, and spatial geometry data was preserved for each LVOTd measurement to convert DL predictions into metric units. A convolutional neural network based on the U-Net was used as the DL model. RESULTS: The mean absolute LVOTd error was 1.04 (95% confidence interval [CI] 0.90-1.19) mm for DL predictions on the test set. The mean relative LVOTd errors across all data subgroups ranged from 3.8 to 5.1% for the test set. Generally, the DL model had superior performance on the ZPLAX view compared to the PLAX view. DL model precision for patients with repeated LVOTd measurements had a mean coefficient of variation of 2.2 (95% CI 1.6-2.7) %, which was comparable to the clinicians for the test set. CONCLUSION: DL for automatic LVOTd measurements in PLAX and ZPLAX views is feasible when trained on a limited clinical dataset. While the DL predicted LVOTd measurements were within the expected range of clinical inter-observer variability, the robustness of the DL model requires validation on independent datasets. Future experiments using temporal information and anatomical constraints could improve valvular identification and reduce outliers, which are challenges that must be addressed before clinical utilization.


Asunto(s)
Aprendizaje Profundo , Humanos , Ecocardiografía , Corazón , Volumen Sistólico
6.
Hypertens Pregnancy ; 42(1): 2245054, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37559403

RESUMEN

AIMS: To objectively study cardiorespiratory fitness (CRF) and physical activity (PA) and to evaluate limiting factors of exercise intolerance associated with poor CRF after severe pre-eclampsia. METHODS: In this single-centre, cross-sectional study, CRF was measured as peak oxygen uptake (VO2peak) during a cardiopulmonary exercise test (CPET) on a treadmill in women 7 years after severe pre-eclampsia. Ninety-six patients and 65 controls were eligible to participate. Cardiac output (CO) was measured by impedance cardiography. PA was measured using accelerometers. RESULTS: In 62 patients and 35 controls (mean age 40 ± 3 years), the VO2peak (in mL·kg-1·min-1) values were 31.4 ± 7.2 and 39.1 ± 5.4, respectively (p<0.01). In the patients, the COpeak was (9.6 L·min-1), 16% lower compared to controls (p<0.01). Twelve patients (19%) had a cardiac limitation to CPET. Twenty-three (37%) patients and one (3%) control were classed as unfit, with no cardiopulmonary limitations. The patients demonstrated 25% lower PA level (in counts per minute; p<0.01) and 14% more time being sedentary (p<0.01), compared with the controls. Twenty-one patients (34%) compared with four (17%) controls did not meet the World Health Organization's recommendations for PA (p=0.02). Body mass index and PA level accounted for 65% of the variability in VO2peak. CONCLUSION: Significantly lower CRF and PA levels were found in patients on long-term follow-up after severe pre-eclampsia. CPET identified cardiovascular limitations in one third of patients. One third appeared unfit, with adiposity and lower PA levels. These findings highlight the need for clinical follow-up and exercise interventions after severe pre-eclampsia.


Asunto(s)
Capacidad Cardiovascular , Preeclampsia , Humanos , Femenino , Adulto , Estudios Transversales , Ejercicio Físico , Prueba de Esfuerzo
7.
Eur Heart J Open ; 3(4): oead072, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37559925

RESUMEN

Aims: The aim was to study pregnancy outcomes in women with coarctation of the aorta (CoA) and associations to hypertensive disorders of pregnancy. Maternal morbidity and mortality are higher in women with heart disease and pre-eclampsia. Chronic hypertension, frequently encountered in CoA, is a risk factor for pre-eclampsia. Methods and results: Clinical data from the National Unit for Pregnancy and Heart Disease database was reviewed for pregnant women with CoA from 2008 to 2021. The primary outcome was hypertensive pregnancy disorders. The secondary outcomes were other cardiovascular, obstetric, and foetal complications. Seventy-six patients were included, with a total of 87 pregnancies. Seventeen (20%) patients were treated for chronic hypertension before pregnancy. Fifteen (20%) patients developed pre-eclampsia, and 5 (7%) had pregnancy-induced hypertension. Major adverse cardiac events developed in four (5%) patients, with no maternal or foetal mortality. Maternal age at first pregnancy [odds ratio (OR) 1.37], body mass index before first pregnancy (OR 1.77), and using acetylsalicylic acid from the first trimester (OR 0.22) were statistically significantly associated with pre-eclampsia. At follow-up (median) 8 years after pregnancy, 29 (38%) patients had anti-hypertensive treatment, an increase of 16% compared to pre-pregnancy. Five (7%) patients had progression of aorta ascendens dilatation to >40 mm, seven (9%) had an upper to lower systolic blood pressure gradient >20 mmHg, and six (8%) had received CoA re-intervention. Conclusion: Pre-eclampsia occurred in 20% of women with CoA in their first pregnancy. All pre-eclamptic patients received adequate anti-hypertensive treatment. All CoA patients were provided multi-disciplinary management, including cardiologic follow-up, to optimize maternal-foetal outcomes.

8.
G Ital Cardiol (Rome) ; 24(1 Suppl 1): e1-e102, 2023 01.
Artículo en Italiano | MEDLINE | ID: mdl-36645369
9.
ASAIO J ; 68(9): 1117-1125, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36066353

RESUMEN

We have previously demonstrated that accelerometer-based vibration analysis detects thromboembolism and pump thrombosis in HeartWare Left Ventricular Assist Device (HVAD) using the third harmonic frequency (pump_speedx3). Thromboembolism also affected the amplitude of the nonharmonic frequencies. The aim of this study was to determine whether nonharmonic-amplitude (NHA) analysis can improve the diagnosis of thromboembolic complications. An accelerometer was attached to HVAD in three in vitro and seven in vivo experiments. Control interventions, including load and pump speed alternations (n = 107), were followed by thromboembolic events (n = 60). A sliding fast-Fourier-transform was analyzed, and changes in NHAs were quantified in the acute phase and in a steady state. Receiver operating characteristic curves were constructed with cutoff values of NHA to detect thromboembolic events. Positive predictive values were calculated on the basis of a specificity of 1. In the acute phase, NHA change was 6.5 times higher under thromboembolism than under control interventions (p < 0.001). Most thromboembolic events lead to concomitant changes in both NHA and third-harmonic amplitude. Combining the two methods improved the PPV by 8.3%. At steady state, signal changes predominantly demonstrated either NHA or third-harmonic changes. Combined signal analysis improved the PPV by 36%. This method enhanced the detection of thromboembolism and pump thrombosis in the HVAD.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Tromboembolia , Trombosis , Acelerometría/métodos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Tromboembolia/diagnóstico , Tromboembolia/etiología , Trombosis/diagnóstico , Trombosis/etiología
11.
J Am Heart Assoc ; 11(14): e023921, 2022 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-35861834

RESUMEN

Background Little is known about the cause of death (CoD) in patients with transposition of the great arteries palliated with a Mustard or Senning procedure. The aim was to describe the CoD for patients with the Mustard and Senning procedure during short- (<10 years), mid- (10-20 years), and long-term (>20 years) follow-up after the operation. Methods and Results This is a retrospective, descriptive multicenter cohort study including all Nordic patients (Denmark, Finland, Norway, and Sweden) who underwent a Mustard or Senning procedure between 1967 and 2003. Patients who died within 30 days after the index operation were excluded. Among 968 patients with Mustard/Senning palliated transposition of the great arteries, 814 patients were eligible for the study, with a mean follow-up of 33.6 years. The estimated risk of all-cause mortality reached 36.0% after 43 years of follow-up, and the risk of death was highest among male patients as compared with female patients (P=0.004). The most common CoD was sudden cardiac death (SCD), followed by heart failure/heart transplantation accounting for 29% and 27%, respectively. During short-, mid-, and long-term follow-up, there was a change in CoD with SCD accounting for 23.7%, 46.6%, and 19.0% (P=0.002) and heart failure/heart transplantation 18.6%, 22.4%, and 46.6% (P=0.0005), respectively. Conclusions Among patients corrected with Mustard or Senning transposition of the great arteries, the most common CoD is SCD followed by heart failure/heart transplantation. The CoD changes as the patients age, with SCD as the most common cause in adolescence and heart failure as the dominant cause in adulthood. Furthermore, the risk of all-cause mortality, SCD, and death attributable to heart failure or heart transplantation was increased in men >10 years after the Mustard/Senning operation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Transposición de los Grandes Vasos , Adolescente , Adulto , Arterias , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Causas de Muerte , Estudios de Cohortes , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Estudios Retrospectivos
12.
Physiol Rep ; 10(8): e15259, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35439365

RESUMEN

Moderate hypothermia has been used to improve outcomes in comatose out-of-hospital cardiac arrest survivors during the past two decades, although the effects remain controversial. We have recently shown in an experimental study that myocardial electrophysiological and mechanical relationships were altered during moderate hypothermia. Electromechanical window positivity increased, and electrical dispersion of repolarization decreased, both of which are changes associated with decreased arrhythmogenicity in clinical conditions. Mechanical dispersion, a parameter also linked to arrhythmic risk, remained unaltered. Whether corresponding electrophysiological and mechanical changes occur in humans during moderate hypothermia, has not been previously explored. Twenty patients with normal left ventricular function were included. Measurements were obtained at 36 and 32°C prior to ascending aortic repair while on partial cardiopulmonary bypass and at 36°C after repair. Registrations were performed in the presence of both spontaneous and comparable paced heart rate during standardized loading conditions. The following electrical and mechanical parameters were explored: (1) Electromechanical window, measured as time difference between mechanical and electrical systole, (2) dispersion of repolarization from ECG T-wave, and (3) mechanical dispersion, measured as segmental variation in time to peak echocardiographic strain. At moderate hypothermia, mechanical systolic prolongation (425 ± 43-588 ± 67 ms, p < 0.001) exceeded electrical systolic prolongation (397 ± 49-497 ± 79 ms, p < 0.001), whereby, electromechanical window positivity increased (29 ± 30-86 ± 50 ms, p < 0.001). Dispersion of repolarization and mechanical dispersion remained unchanged. Corresponding electrophysiological and mechanical relationships were present at comparable paced heart rates. After rewarming, the increased electromechanical window was reversed in the presence of both spontaneous and paced heart rates. Moderate hypothermia increased electromechanical window positivity, while dispersion of repolarization and mechanical dispersion remained unchanged. This impact of hypothermia may be clinically relevant for selected groups of patients after cardiac arrest.


Asunto(s)
Paro Cardíaco , Hipotermia , Arritmias Cardíacas/etiología , Electrofisiología Cardíaca , Electrocardiografía , Paro Cardíaco/terapia , Humanos , Miocardio
13.
J Am Heart Assoc ; 11(8): e024960, 2022 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-35434999

RESUMEN

Background We aimed to assess the association between number of pregnancies and long-term progression of cardiac dysfunction, arrhythmias, and event-free survival in women with pathogenic or likely pathogenic variants of gene encoding for Lamin A/C proteins ( LMNA+). Methods and Results We retrospectively included consecutive women with LMNA+ and recorded pregnancy data. We collected echocardiographic data, occurrence of atrial fibrillation, atrioventricular block, sustained ventricular arrhythmias, and implantation of cardiac electronic devices (implantable cardioverter defibrillator/cardiac resynchronization therapy defibrillator). We analyzed retrospectively complications during pregnancy and the peripartum period. We included 89 women with LMNA+ (28% probands, age 41±16 years), of which 60 had experienced pregnancy. Follow-up time was 5 [interquartile range, 3-9] years. We analyzed 452 repeated echocardiographic examinations. Number of pregnancies was not associated with increased long-term risk of atrial fibrillation, atrioventricular block, sustained ventricular arrhythmias, or implantable cardioverter defibrillator/cardiac resynchronization therapy defibrillator implantation. Women with previous pregnancy and nulliparous women had a similar annual deterioration of left ventricular ejection fraction (-0.5/year versus -0.3/year, P=0.37) and similar increase of left ventricular end-diastolic diameter (0.1/year versus 0.2/year, P=0.09). Number of pregnancies did not decrease survival free from death, left ventricular assist device, or need for cardiac transplantation. Arrhythmias occurred during 9% of pregnancies. No increase in maternal and fetal complications was observed. Conclusions In our cohort of women with LMNA+, pregnancy did not seem associated with long-term adverse disease progression or event-free survival. Likewise, women with LMNA+ generally well-tolerated pregnancy, with a small proportion of patients experiencing arrhythmias.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Cardiomiopatías , Desfibriladores Implantables , Adulto , Cardiomiopatías/genética , Cardiomiopatías/terapia , Femenino , Genotipo , Humanos , Lamina Tipo A/genética , Masculino , Persona de Mediana Edad , Embarazo , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda
14.
Crit Care Med ; 50(1): e52-e60, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34259452

RESUMEN

OBJECTIVES: Targeted temperature management (32-36°C) is used for neuroprotection in cardiac arrest survivors. The isolated effects of hypothermia on myocardial function, as used in clinical practice, remain unclear. Based on experimental results, we hypothesized that hypothermia would reversibly impair diastolic function with less tolerance to increased heart rate in patients with uninsulted hearts. DESIGN: Prospective clinical study, from June 2015 to May 2018. SETTING: Cardiothoracic surgery operation room, Oslo University Hospital. PATIENTS: Twenty patients with left ventricular ejection fraction greater than 55%, undergoing ascending aorta graft-replacement connected to cardiopulmonary bypass were included. INTERVENTIONS: Left ventricular function was assessed during reduced cardiopulmonary bypass support at 36°C, 32°C prior to graft-replacement, and at 36°C postsurgery. Electrocardiogram, hemodynamic, and echocardiographic recordings were made at spontaneous heart rate and 90 beats per minute at comparable loading conditions. MEASUREMENTS AND MAIN RESULTS: Hypothermia decreased spontaneous heart rate, and R-R interval was prolonged (862 ± 170 to 1,156 ± 254 ms, p < 0.001). Although systolic and diastolic fractions of R-R interval were preserved (0.43 ± 0.07 and 0.57 ± 0.07), isovolumic relaxation time increased and diastolic filling time was shortened. Filling pattern changed from early to late filling. Systolic function was preserved with unchanged myocardial strain and stroke volume index, but cardiac index was reduced with maintained mixed venous oxygen saturation. At increased heart rate, systolic fraction exceeded diastolic fraction (0.53 ± 0.05 and 0.47 ± 0.05) with diastolic impairment. Strain and stroke volume index were reduced, the latter to 65% of stroke volume index at spontaneous heart rate. Cardiac index decreased, but mixed venous oxygen saturation was maintained. After rewarming, myocardial function was restored. CONCLUSIONS: In patients with normal left ventricular function, hypothermia impaired diastolic function. At increased heart rate, systolic function was subsequently reduced due to impeded filling. Changes in left ventricular function were rapidly reversed after rewarming.


Asunto(s)
Paro Cardíaco/terapia , Hipotermia Inducida/métodos , Hipotermia/fisiopatología , Recalentamiento , Función Ventricular Izquierda/fisiología , Anciano , Electrocardiografía , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
16.
Open Heart ; 8(2)2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34663747

RESUMEN

OBJECTIVE: Adults operated for tetralogy of Fallot (TOF) have high risk of ventricular arrhythmias (VA). QRS duration >180 ms is an established risk factor for VA. We aimed to investigate heart function, prevalence of arrhythmias and sex differences in patients with TOF at long-term follow-up. METHODS: We included TOF-operated patients≥18 years from our centre's registry. We reviewed medical records and the most recent echocardiographic exam. VA was recorded on ECGs, 24-hour Holter registrations and from implantable cardioverter defibrillator. RESULTS: We included 148 patients (age 37±10 years). Left ventricular global longitudinal strain (LV GLS, -15.8±3.1% vs -18.8±3.2%, p=0.001) and right ventricular (RV) GLS (-15.8±3.9% vs -19.1±4.1%, p=0.001) were lower in men at all ages compared with women. Higher RV D1 (4.3±0.5 cm vs 4.6±0.6 cm, p=0.01), lower ejection fraction (55%±8% vs 50%±9%, p=0.02), lower RV GLS (-18.1±4.0 ms vs -16.1±4.8 ms, p=0.04) and N-terminal pro-brain natriuretic peptide (NT-proBNP) over reference range (n=27 (23%) vs n=8 (77%), p<0.001) were associated with higher incidence of VA. QRS duration was longer in men (151±30 ms vs 128±25 ms, p<0.001). No patients had QRS duration >180 ms. QRS duration did not differ in those with and without VA (143±32 ms vs 137±28 ms, p=0.06). CONCLUSIONS: Our results confirmed reduced RV function in adults operated for TOF. Male patients had impaired LV and RV function expressed by lower LV and RV GLS values at all ages. Reduced cardiac function and elevated NT-proBNP were associated with higher incidence of VA and may be important in risk assessment.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Tetralogía de Fallot/epidemiología , Adolescente , Adulto , Niño , Preescolar , Ecocardiografía , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Morbilidad/tendencias , Noruega/epidemiología , Estudios Retrospectivos , Distribución por Sexo , Factores Sexuales , Tetralogía de Fallot/diagnóstico , Tetralogía de Fallot/cirugía , Factores de Tiempo , Adulto Joven
17.
JACC Cardiovasc Imaging ; 14(11): 2059-2069, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34147454

RESUMEN

OBJECTIVES: This study sought to investigate if contractile asymmetry between septum and left ventricular (LV) lateral wall drives heart failure development in patients with left bundle branch block (LBBB) and whether the presence of lateral wall dysfunction affects potential for recovery of LV function with cardiac resynchronization therapy (CRT). BACKGROUND: LBBB may induce or aggravate heart failure. Understanding the underlying mechanisms is important to optimize timing of CRT. METHODS: In 76 nonischemic patients with LBBB and 11 controls, we measured strain using speckle-tracking echocardiography and regional work using pressure-strain analysis. Patients with LBBB were stratified according to LV ejection fraction (EF) ≥50% (EFpreserved), 36% to 49% (EFmid), and ≤35% (EFlow). Sixty-four patients underwent CRT and were re-examined after 6 months. RESULTS: Septal work was successively reduced from controls, through EFpreserved, EFmid, and EFlow (all p < 0.005), and showed a strong correlation to left ventricular ejection fraction (LVEF; r = 0.84; p < 0.005). In contrast, LV lateral wall work was numerically increased in EFpreserved and EFmid versus controls, and did not significantly correlate with LVEF in these groups. In EFlow, however, LV lateral wall work was substantially reduced (p < 0.005). There was a moderate overall correlation between LV lateral wall work and LVEF (r = 0.58; p < 0.005). In CRT recipients, LVEF was normalized (≥50%) in 54% of patients with preserved LV lateral wall work, but only in 13% of patients with reduced LV lateral wall work (p < 0.005). CONCLUSIONS: In early stages, LBBB-induced heart failure is associated with impaired septal function but preserved lateral wall function. The advent of LV lateral wall dysfunction may be an optimal time-point for CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Bloqueo de Rama/complicaciones , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Humanos , Valor Predictivo de las Pruebas , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
18.
PLoS One ; 16(4): e0249610, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33826652

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Patients with asymptomatic, severe aortic stenosis are presumed to have a benign prognosis. In this retrospective cohort study, we examined the natural history of contemporary patients advised against aortic valve replacement due to a perceived lack of symptoms. MATERIALS AND METHODS: We reviewed the medical records of every patient given the ICD-10-code for aortic stenosis (I35.0) at Oslo University Hospital, Rikshospitalet, between Dec 1st, 2002 and Dec 31st, 2016. Patients who were evaluated by the heart team due to severe aortic stenosis were categorized by treatment strategy. We recorded baseline data, adverse events and survival for the patients characterized as asymptomatic and for 100 age and gender matched patients scheduled for aortic valve replacement. RESULTS: Of 2341 patients who were evaluated for aortic valve replacement due to severe aortic stenosis, 114 patients received conservative treatment due to a lack of symptoms. Asymptomatic patients had higher mortality than patients who had aortic valve replacement, log-rank p<0.001 (mean follow-up time: 4.0 (SD: 2.5) years). Survival at 1, 2 and 3 years for the asymptomatic patients was 88%, 75% and 63%, compared with 92%, 83% and 78% in the matched patients scheduled for aortic valve replacement. 28 (25%) of the asymptomatic patients had aortic valve replacement during follow-up. Age, previous history of coronary artery disease and N-terminal pro B-type natriuretic peptide (NT-proBNP) were predictors of mortality and coronary artery disease and NT-proBNP were predictors of 3-year morbidity in asymptomatic patients. CONCLUSIONS: In this retrospective study, asymptomatic patients with severe aortic stenosis who were advised against surgery had significantly higher mortality than patients who had aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Enfermedades Asintomáticas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Índice de Severidad de la Enfermedad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/terapia , Enfermedades Asintomáticas/terapia , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Pronóstico , Estudios Retrospectivos , Tasa de Supervivencia
19.
Acta Anaesthesiol Scand ; 65(5): 648-655, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33595102

RESUMEN

BACKGROUND: Transpulmonary passage of air emboli can lead to fatal brain- and myocardial infarctions. We studied whether pigs with open chest and pericardium had a greater transpulmonary passage of venous air emboli than pigs with closed thorax. METHODS: We allocated pigs with verified closed foramen ovale to venous air infusion with either open chest with sternotomy and opening of the pleura and pericardium (n = 8) or closed thorax (n = 16). All pigs received a five-hour intravenous infusion of ambient air, starting at 4-6 mL/kg/h and increased by 2 mL/kg/h each hour. We assessed transpulmonary air passage by transesophageal M-mode echocardiography and present the results as median with inter-quartile range (IQR). RESULTS: Transpulmonary air passage occurred in all pigs with open chest and pericardium and in nine pigs with closed thorax (56%). Compared to pigs with closed thorax, pigs with open chest and pericardium had a shorter to air passage (10 minutes (5-16) vs. 120 minutes (44-212), P < .0001), a smaller volume of infused air at the time of transpulmonary passage (12 mL (10-23) vs.170 mL (107-494), P < .0001), shorter time to death (122 minutes (48-185) vs 263 minutes (248-300, P = .0005) and a smaller volume of infused air at the time of death (264 mL (53-466) vs 727 mL (564-968), P = .001). In pigs with open chest and, infused air and time to death correlated strongly (r = 0.95, P = .001). CONCLUSION: Open chest and pericardium facilitated the transpulmonary passage of intravenously infused air in pigs.


Asunto(s)
Embolia Aérea , Animales , Ecocardiografía , Pericardio , Porcinos , Tórax
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...