Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Environ Sci Technol ; 57(8): 3075-3084, 2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36796018

RESUMEN

Several thousand intentional and unintentional chemical releases occur annually in the U.S., with the contents of almost 30% being of unknown composition. When targeted methods are unable to identify the chemicals present, alternative approaches, including non-targeted analysis (NTA) methods, can be used to identify unknown analytes. With new and efficient data processing workflows, it is becoming possible to achieve confident chemical identifications via NTA in a timescale useful for rapid response (typically 24-72 h after sample receipt). To demonstrate the potential usefulness of NTA in rapid response situations, we have designed three mock scenarios that mimic real-world events, including a chemical warfare agent attack, the contamination of a home with illicit drugs, and an accidental industrial spill. Using a novel, focused NTA method that utilizes both existing and new data processing/analysis methods, we have identified the most important chemicals of interest in each of these designed mock scenarios in a rapid manner, correctly assigning structures to more than half of the 17 total features investigated. We have also identified four metrics (speed, confidence, hazard information, and transferability) that successful rapid response analytical methods should address and have discussed our performance for each metric. The results reveal the usefulness of NTA in rapid response scenarios, especially when unknown stressors need timely and confident identification.

2.
Anal Chim Acta ; 1190: 339258, 2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-34857134

RESUMEN

Several species are simultaneously used for internal standardization to improve accuracy in inductively coupled plasma optical emission spectrometry (ICP-OES). In multi-internal standard calibration (MISC), signal ratios between the analyte and each of several internal standard species are used for calibration. A single calibration solution is required, and the MISC graph is built with intensity ratios calculated with analytical signals recorded for the sample (IA,sam) on the y-axis, while those recorded for the calibration standard (IA,std) are plot on the x-axis (i.e. IA,sam/IIS(i)vs. IA,std/IIS(i), where IIS(i) represents the signal intensity for a given internal standard species). Nine analytes (As, Cd, Cr, Cu, Fe, Mg, Mn, Pb and Zn), and two sets of internal standard species (i.e. Bi, Ge, In, Rh, Sc, Te, Tl and Y in solution, or eighteen emission lines from plasma naturally occurring Ar) were evaluated in this proof-of-concept study. The MISC method's efficiency was evaluated by analyte addition and recovery experiments and by analyzing two certified reference materials. Figures of merit for MISC (limit of detection, repeatability and trueness) were comparable to those obtained for the traditional external standard calibration (EC) and internal standard (IS) methods. Different from IS, MISC requires no time-consuming study to identify an ideal internal standard species, and signal biases are minimized by an averaged, more encompassing internal standardization effect.


Asunto(s)
Calibración , Estándares de Referencia , Análisis Espectral
3.
Anal Bioanal Chem ; 413(5): 1293-1302, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33388844

RESUMEN

The extrapolation approach, traditionally used with standard additions (SA), is compared with the alternative strategies of interpolation, reversed-axis, and normalization. The interpolation approach is based on employing twice the analytical signal recorded for the sample (ysam) to determine an unknown analyte concentration. In the reversed-axis strategy, x- and y-axes are swapped when building the SA calibration plot to facilitate uncertainty estimation. A new strategy, based on signal normalization using ysam, is also described and compared to the other approaches. Results from 3 instrumental methods, 396 sample replicates, 16 analytes, and 2 certified reference materials are included in this study. For most applications, all four SA approaches provide statistically similar trueness and precision. However, extrapolation and reversed-axis provide more consistent values (within narrower ranges) than the other strategies when employing inductively coupled plasma optical emission spectrometry (ICP OES). On the other hand, normalization provides better trueness for the less robust method of microwave-induced plasma OES (MIP OES), as it is capable of minimizing systematic errors associated with different points of the calibration curve. Normalization is particularly useful for quickly processing data, without the need for inspecting each individual calibration plot to identify outlying points. Reversed-axis and normalization are the most adequate approaches for SA applications involving MIP OES and ICP-based methods. In addition to providing similar accuracies to the traditional extrapolation approach, these strategies present the advantage of a simple uncertainty estimation, which can be easily calculated using commonly available software such as Microsoft Excel and R.

4.
Talanta ; 205: 120160, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31450451

RESUMEN

Simple data processing and unattended calibration are achieved in automated standard dilution analysis (aSDA) using two internal standards and an inline lab-made mixing chamber furnished from a common plastic syringe. Only two calibration solutions are required per sample, which minimizes reagent consumption and waste generation. Solution 1 contains 50% sample and 50% of a standard containing the analytes and internal standard 1 (IS1). Solution 2 has 50% sample and 50% of a blank containing internal standard 2 (IS2). The concentration of analyte in the sample is calculated from (i) the slope and intercept of an analyte vs. IS1 plot, (ii) the concentration of analyte in the standard added to Solution 1, and (iii) the intercept of a second plot with IS1vs. IS2. The aSDA method was used to determine Cd, Co, Cr, Cu, Pb and Zn in tap and creek water, beer, cola soft drink, mouthwash, cough syrup and cachaça by ICP OES. Addition/recovery experiments involving these same samples and other challenging matrices (i.e. 40% v/v HNO3, and 1% m/v Na, Ca or C) were performed to evaluate the method's accuracy. The results were compared with values obtained with external standard calibration (EC), internal standardization (IS) and standard additions (SA). Considering all samples and analytes evaluated, aSDA provided the best accuracy, with an average absolute error (ε‾=|analytepercentrecovery-100|) of 4% (EC, IS and SA had 13%, 9% and 7% errors, respectively). The aSDA strategy is a simple and inexpensive alternative to traditional methods. It has great potential for broad implementation with existing ICP OES instrumentation, as it requires little modification to systems already in place in routine laboratories.

5.
J Trace Elem Med Biol ; 54: 62-68, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31109622

RESUMEN

BACKGROUND: Platinum-based anticancer drugs are relatively successful chemotherapeutic agents, which can cause significant elemental changes in key organs and are known for undesirable side effects, such as nephrotoxicity (damage to the kidneys). OBJECTIVES AND METHODS: Inductively coupled plasma mass spectrometry (ICP-MS) and traditional statistical tools such as two-sample Student's t-test and Pearson's correlation analysis are used to evaluate the effects of different investigational Pt-based anticancer drugs on the elemental constitution of kidneys and liver of mice. Principal component analysis is used to uncover relationships in element concentration and potential correlations between those and clinical effects. Random forest importance is used to identify elements most associated with the drug's maximum tolerated doses (MTDs). RESULTS: Strong negative correlations between Pt and both Cu (-0.814) and Zn (-0.784) in kidneys were observed for one of the Pt-acridine anticancer agents evaluated (Drug C). Strong positive correlations were observed between Cu in both kidneys (0.834) and liver (0.756) with Zn in liver for the same compound. Cisplatin administration correlates to higher concentrations of Ca, Cu, Rb and Zn in liver. Calcium and Mo in kidneys and Pt and Zn in liver are the features most associated with MTDs. CONCLUSIONS: The results indicate that the Pt-based agents investigated are major modulators of ion homeostasis in excretory organs, which most likely contributes to their systemic toxicity and limits their efficacy. A better understanding of subtle patterns and correlations among elements in key organs may provide deeper insights into the mechanisms of action and ultimately contribute for better, safer drugs. To achieve this goal, researchers involved in cancer drug development may leverage the high sensitivity and high sample throughput of ICP-MS, and the capabilities of modern statistical tools to extract relevant information from a large dataset.


Asunto(s)
Antineoplásicos/farmacología , Riñón/efectos de los fármacos , Riñón/metabolismo , Hígado/efectos de los fármacos , Hígado/metabolismo , Oligoelementos/análisis , Animales , Calcio/análisis , Cobre/análisis , Espectrometría de Masas , Ratones , Análisis de Componente Principal , Rubidio/análisis , Zinc/análisis
6.
Anal Chim Acta ; 1062: 37-46, 2019 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-30947994

RESUMEN

An unsupervised data-driven methodology is used to quantify matrix effects caused by carbon and easily ionizable elements (EIEs) in inductively coupled plasma optical emission spectrometry (ICP OES). Background signals from nine plasma naturally-occurring species of Ar, H and O are used with principal component analysis (PCA) and affinity propagation (AP) clustering to evaluate the effects of complex matrices on ionic emission lines of Cd, Co, Cr and Pb. Matrix effect severity is then quantified based on Euclidean distance in principal component space from an average calibration curve point. The method has been applied to spiked solutions of Mediterranean Sea and Dead Sea water samples, and a significant correlation (- 0.997) was found between Euclidean distance and analyte recoveries. For sea water analysis, accurate results are found using external standard calibration (EC) when Euclidean distance < 1 for a given sample, and/or when that sample point groups with the calibration curve after affinity propagation clustering. Thus, by applying the PCA-AP strategy, one needs to perform no addition/recovery experiment to evaluate EC applicability. In addition, it can be carried out on the fly, as the background species used to monitor plasma changes are simultaneously recorded with the analytical signals, and a specific algorithm can be added to the instrument control software to flag instances in which EC may be ineffective. This is a proof-of-concept study, and additional work is required to evaluate the method's applicability to a larger number of analytes and sample matrices. However, the PCA-AP method described here for ICP OES can be used to quantify matrix effects, allowing for informed decisions regarding calibration. It requires no additional sample preparation and can be easily implemented in routine analyses of such complex-matrix samples as sea water.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...