Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Bioanalysis ; 16(7): 77-119, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38389403

RESUMEN

The 17th Workshop on Recent Issues in Bioanalysis (17th WRIB) took place in Orlando, FL, USA on June 19-23, 2023. Over 1000 professionals representing pharma/biotech companies, CROs, and multiple regulatory agencies convened to actively discuss the most current topics of interest in bioanalysis. The 17th WRIB included 3 Main Workshops and 7 Specialized Workshops that together spanned 1 week to allow an exhaustive and thorough coverage of all major issues in bioanalysis of biomarkers, immunogenicity, gene therapy, cell therapy and vaccines. Moreover, in-depth workshops on "EU IVDR 2017/746 Implementation and impact for the Global Biomarker Community: How to Comply with these NEW Regulations" and on "US FDA/OSIS Remote Regulatory Assessments (RRAs)" were the special features of the 17th edition. As in previous years, WRIB continued to gather a wide diversity of international, industry opinion leaders and regulatory authority experts working on both small and large molecules as well as gene, cell therapies and vaccines to facilitate sharing and discussions focused on improving quality, increasing regulatory compliance, and achieving scientific excellence on bioanalytical issues. This 2023 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2023 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 3) covers the recommendations on Gene Therapy, Cell therapy, Vaccines and Biotherapeutics Immunogenicity. Part 1A (Mass Spectrometry Assays and Regulated Bioanalysis/BMV), P1B (Regulatory Inputs) and Part 2 (Biomarkers, IVD/CDx, LBA and Cell-Based Assays) are published in volume 16 of Bioanalysis, issues 8 and 9 (2024), respectively.


Asunto(s)
Bioensayo , Tecnología , Bioensayo/métodos , Biomarcadores/análisis , Tratamiento Basado en Trasplante de Células y Tejidos , Inmunoterapia Activa
2.
Bioanalysis ; 15(15): 861-903, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37584363

RESUMEN

The 16th Workshop on Recent Issues in Bioanalysis (16th WRIB) took place in Atlanta, GA, USA on September 26-30, 2022. Over 1000 professionals representing pharma/biotech companies, CROs, and multiple regulatory agencies convened to actively discuss the most current topics of interest in bioanalysis. The 16th WRIB included 3 Main Workshops and 7 Specialized Workshops that together spanned 1 week in order to allow exhaustive and thorough coverage of all major issues in bioanalysis, biomarkers, immunogenicity, gene therapy, cell therapy and vaccines. Moreover, in-depth workshops on ICH M10 BMV final guideline (focused on this guideline training, interpretation, adoption and transition); mass spectrometry innovation (focused on novel technologies, novel modalities, and novel challenges); and flow cytometry bioanalysis (rising of the 3rd most common/important technology in bioanalytical labs) were the special features of the 16th edition. As in previous years, WRIB continued to gather a wide diversity of international, industry opinion leaders and regulatory authority experts working on both small and large molecules as well as gene, cell therapies and vaccines to facilitate sharing and discussions focused on improving quality, increasing regulatory compliance, and achieving scientific excellence on bioanalytical issues. This 2022 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2022 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations on LBA, Biomarkers/CDx and Cytometry. Part 1 (Mass Spectrometry and ICH M10) and Part 3 (Gene Therapy, Cell therapy, Vaccines and Biotherapeutics Immunogenicity) are published in volume 15 of Bioanalysis, issues 16 and 14 (2023), respectively.


Asunto(s)
Bioensayo , Informe de Investigación , Citometría de Flujo/métodos , Ligandos , Biomarcadores/análisis , Bioensayo/métodos
3.
Artículo en Inglés | MEDLINE | ID: mdl-35732105

RESUMEN

The majority of women have health problems that require medication after giving birth. Complications such as allergies, postpartum depression, and diabetes are often treated with drugs such as cetirizine, venlafaxine, and metformin, respectively. These treatments are considered safe during lactation, but information of the transfer of drugs to breast milk and possible effects on the infant is scarce. Therefore, this needs to be systematically investigated in larger populations. To enable the determination of drug transfer, we here describe the validation of two rapid, sensitive, and high-throughput analysis methods for 1) simultaneous quantification of cetirizine, venlafaxine, and O-desmethylvenlafaxine in human breast milk, and 2) metformin in human breast milk and plasma. In both methods, a simple protein precipitation protocol with acetonitrile and benchtop-centrifugation was used prior to compound analysis with liquid-chromatography tandem mass spectrometry. The methods had linear ranges between 0.39 - 194.5 ng/mL for cetirizine, 0.28 - 138.7 ng/mL for venlafaxine, 0.26 - 131.7 ng/mL for O-desmethylvenlafaxine, in milk, and 0.65 - 193.7 ng/mL for metformin in both milk and plasma. Intra-run and inter-run precision and accuracy were ≤ 9% for cetirizine, venlafaxine, and O-desmethylvenlafaxine in milk, and ≤ 7% for metformin in milk and plasma. Cetirizine was measured to median milk concentrations of 13 ng/mL (range: 0.65 - 65 ng/mL) in 228 donor samples from breast-feeding women.


Asunto(s)
Metformina , Espectrometría de Masas en Tándem , Cetirizina , Cromatografía Líquida de Alta Presión/métodos , Succinato de Desvenlafaxina , Femenino , Humanos , Lactante , Leche Humana , Embarazo , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos , Clorhidrato de Venlafaxina
4.
Life (Basel) ; 12(2)2022 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-35207446

RESUMEN

We present our approach to rapidly establishing a standardized, multi-site, nation-wide COVID-19 screening program in Belgium. Under auspices of a federal government Task Force responsible for upscaling the country's testing capacity, we were able to set up a national testing initiative with readily available resources, putting in place a robust, validated, high-throughput, and decentralized qPCR molecular testing platform with embedded proficiency testing. We demonstrate how during an acute scarcity of equipment, kits, reagents, personnel, protective equipment, and sterile plastic supplies, we introduced an approach to rapidly build a reliable, validated, high-volume, high-confidence workflow based on heterogeneous instrumentation and diverse assays, assay components, and protocols. The workflow was set up with continuous quality control monitoring, tied together through a clinical-grade information management platform for automated data analysis, real-time result reporting across different participating sites, qc monitoring, and making result data available to the requesting physician and the patient. In this overview, we address challenges in optimizing high-throughput cross-laboratory workflows with minimal manual intervention through software, instrument and assay validation and standardization, and a process for harmonized result reporting and nation-level infection statistics monitoring across the disparate testing methodologies and workflows, necessitated by a rapid scale-up as a response to the pandemic.

5.
J Mol Diagn ; 23(10): 1249-1258, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34358676

RESUMEN

Nasopharyngeal swabs are considered the preferential collection method for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnostics. Less invasive and simpler alternative sampling procedures, such as saliva collection, are desirable. We compared saliva specimens and nasopharyngeal (NP) swabs with respect to sensitivity in detecting SARS-CoV-2. A nasopharyngeal and two saliva specimens (collected by spitting or oral swabbing) were obtained from >2500 individuals. All samples were tested by RT-qPCR, detecting RNA of SARS-CoV-2. The test sensitivity was compared on the two saliva collections with the nasopharyngeal specimen for all subjects and stratified by symptom status and viral load. Of the 2850 patients for whom all three samples were available, 105 were positive on NP swab, whereas 32 and 23 were also positive on saliva spitting and saliva swabbing samples, respectively. The sensitivity of the RT-qPCR to detect SARS-CoV-2 among NP-positive patients was 30.5% (95% CI, 1.9%-40.2%) for saliva spitting and 21.9% (95% CI, 14.4%-31.0%) for saliva swabbing. However, when focusing on subjects with medium to high viral load, sensitivity on saliva increased substantially: 93.9% (95% CI, 79.8%-99.3%) and 76.9% (95% CI, 56.4%-91.0%) for spitting and swabbing, respectively, regardless of symptomatic status. Our results suggest that saliva cannot readily replace nasopharyngeal sampling for SARS-CoV-2 diagnostics but may enable identification of the most contagious cases with medium to high viral loads.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/virología , Saliva/virología , Manejo de Especímenes/métodos , Adulto , COVID-19/etiología , Portador Sano/virología , Humanos , Nasofaringe/virología , Estudios Prospectivos , Manejo de Especímenes/instrumentación , Carga Viral
6.
Pharmacol Res Perspect ; 7(1): e00459, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30705758

RESUMEN

In this phase I, single-center, open-label study of ten heathy adults (18-45 years; NCT02647697), the PK, safety, and tolerability profile of radiprodil oral suspension in healthy adults were assessed, as well as two PK microsampling techniques. All participants received a single 30 mg radiprodil dose (12 mL oral suspension). Blood was collected at various time points using conventional venous sampling (intravenous catheter or venepuncture), and Mitra™ and Aqua-Cap™ Drummond microsampling (finger-prick and blood taken from venous blood sample tubes). Geometric mean radiprodil plasma concentrations from conventional venous samples were above the lower limit of quantification up to 48 hours after administration of a single oral dose of radiprodil. Geometric mean AUC inf and Cmax were 2042 h ng mL -1 and 89.4 ng mL -1, respectively. Geometric mean t½ was 15.8 hour; median tmax was 4 hour (range: 3-6 hour). Radiprodil exposure variables for Aqua-Cap™ Drummond sampling were similar to the conventional venous-derived data. Conversely, radiprodil exposure variables were lower with Mitra™ sampling compared with conventional venous sampling. The geometric mean ratio (90% confidence interval) for Cmax of conventional venous versus Mitra™ and Aqua-Cap™ Drummond sampling (finger-prick blood) was 0.89 (0.85, 0.94) and 1.03 (0.97,1.08), respectively, and therefore within the conventional bioequivalence range (0.80-1.25). Radiprodil oral suspension had an acceptable safety, tolerability, and palatability profile. The PK profile of radiprodil oral suspension was established in healthy adults, and was comparable when analyzed using conventional versus microsampling techniques. These results will support future radiprodil paediatric studies.


Asunto(s)
Acetamidas/farmacocinética , Recolección de Muestras de Sangre/métodos , Piperidinas/farmacocinética , Receptores de N-Metil-D-Aspartato/antagonistas & inhibidores , Acetamidas/administración & dosificación , Acetamidas/efectos adversos , Administración Oral , Adulto , Disponibilidad Biológica , Cromatografía Líquida de Alta Presión , Estudios Cruzados , Femenino , Voluntarios Sanos , Humanos , Masculino , Piperidinas/administración & dosificación , Piperidinas/efectos adversos , Suspensiones , Espectrometría de Masas en Tándem , Equivalencia Terapéutica , Adulto Joven
8.
Bioanalysis ; 9(16): 1217-1226, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28705025

RESUMEN

AIM: In order to evaluate placental transfer of certolizumab pegol (CZP), a more sensitive and selective bioanalytical assay was required to accurately measure low CZP concentrations in infant and umbilical cord blood. Results & methodology: A new electrochemiluminescence immunoassay was developed to measure CZP levels in human plasma. Validation experiments demonstrated improved selectivity (no matrix interference observed) and a detection range of 0.032-5.0 µg/ml. Accuracy and precision met acceptance criteria (mean total error ≤20.8%). Dilution linearity and sample stability were acceptable and sufficient to support the method. CONCLUSION: The electrochemiluminescence immunoassay was validated for measuring low CZP concentrations in human plasma. The method demonstrated a more than tenfold increase in sensitivity compared with previous assays, and improved selectivity for intact CZP.


Asunto(s)
Análisis Químico de la Sangre/métodos , Certolizumab Pegol/sangre , Límite de Detección , Calibración , Ensayo de Inmunoadsorción Enzimática , Sangre Fetal/química , Humanos , Lactante
9.
Bioanalysis ; 9(9): 675-681, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28520459

RESUMEN

European Bioanalysis Forum Focus Workshop, Lisbon, Portugal, 9-10 June 2016 At the recent European Bioanalysis Forum's Focus Workshop 'Bringing Assay Validation and Analysis of Biomarkers into Practice', the discussion on best practice for biomarker assay validation continued. Both the presentations and the adjacent panel discussions yielded valuable food for thought for the broader bioanalytical community. The present conference report summarizes the essence from these discussions and from the proposals or conclusions made by all delegates on how to increase the necessary connectivity of the stakeholders involved in the bioanalysis of biomarkers.


Asunto(s)
Biomarcadores/análisis , Técnicas de Química Analítica/métodos , Humanos , Portugal , Estudios de Validación como Asunto
10.
Bioanalysis ; 8(23): 2475-2496, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27855512

RESUMEN

The 2016 10th Workshop on Recent Issues in Bioanalysis (10th WRIB) took place in Orlando, Florida with participation of close to 700 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations, and regulatory agencies worldwide. WRIB was once again a weeklong event - A Full Immersion Week of Bioanalysis for PK, Biomarkers and Immunogenicity. As usual, it is specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecules involving LCMS, hybrid LBA/LCMS, and LBA approaches, with the focus on PK, biomarkers and immunogenicity. This 2016 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. This White Paper is published in 3 parts due to length. This part (Part 3) discusses the recommendations for large molecule bioanalysis using LBA, biomarkers and immunogenicity. Parts 1 (small molecule bioanalysis using LCMS) and Part 2 (Hybrid LBA/LCMS and regulatory inputs from major global health authorities) have been published in the Bioanalysis journal, issues 22 and 23, respectively.


Asunto(s)
Biomarcadores/análisis , Ligandos , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales/farmacocinética , Cromatografía Líquida de Alta Presión , Conferencias de Consenso como Asunto , Agencias Gubernamentales , Humanos , Sustancias Macromoleculares/análisis , Sustancias Macromoleculares/inmunología , Sustancias Macromoleculares/farmacocinética , Espectrometría de Masas , Estudios de Validación como Asunto
11.
Bioanalysis ; 8(12): 1297-305, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27217058

RESUMEN

Metabolite quantification and profiling continues to grow in importance in today's drug development. The guidance provided by the 2008 FDA Metabolites in Safety Testing Guidance and the subsequent ICH M3(R2) Guidance (2009) has led to a more streamlined process to assess metabolite exposures in preclinical and clinical studies in industry. In addition, the European Bioanalysis Forum (EBF) identified an opportunity to refine the strategies on metabolite quantification considering the experience to date with their recommendation paper on the subject dating from 2010 and integrating the recent discussions on the tiered approach to bioanalytical method validation with focus on metabolite quantification. The current manuscript summarizes the discussion and recommendations from a recent EBF Focus Workshop into an updated recommendation for metabolite quantification in drug development.


Asunto(s)
Descubrimiento de Drogas/métodos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/metabolismo , Preparaciones Farmacéuticas/metabolismo , Animales , Europa (Continente) , Humanos , Metabolómica/métodos
12.
Bioanalysis ; 7(24): 3107-24, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26635247

RESUMEN

The 2015 9th Workshop on Recent Issues in Bioanalysis (9th WRIB) took place in Miami, Florida with participation of 600 professionals from pharmaceutical and biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5 day, week-long event - A Full Immersion Bioanalytical Week - specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS and LBA approaches, including the focus on biomarkers and immunogenicity. This 2015 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2015 edition of this comprehensive White Paper has been divided into three parts. Part 3 discusses the recommendations for large molecule bioanalysis using LBA, biomarkers and immunogenicity. Part 1 (small molecule bioanalysis using LCMS) and Part 2 (hybrid LBA/LCMS and regulatory inputs from major global health authorities) have been published in volume 7, issues 22 and 23 of Bioanalysis, respectively.


Asunto(s)
Anticuerpos Neutralizantes/inmunología , Bioensayo , Biomarcadores/análisis , Biofarmacia/organización & administración , Biotecnología/organización & administración , Humanos
13.
Bioanalysis ; 7(18): 2387-2398, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26354595

RESUMEN

The principles of tiered approach have been part of the bioanalytical toolbox for some years. Nevertheless, an in spite of many valuable discussions in industry, they remain difficult to apply in a harmonized way for a broad array of studies in early drug development where these alternative approaches to regulated validation would make sense. The European Bioanalysis Forum has identified the need to proposes some practical workflows for five categories of studies for chromatography based assays where scientific validation will allow additional freedom while safeguarding scientific rigor and robust documentation: quantification of metabolites in plasma in relation to ICH M3(R2), urine analysis, tissue homogenate analysis, and preclinical and clinical studies in early stages of drug development. The recommendation would introduce a common language and harmonized best practice for these study categories and can help to refocus towards optimized scientific and resource investments for bioanalysis in early drug development.

14.
Bioanalysis ; 6(22): 3039-49, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25496256

RESUMEN

The 2014 8th Workshop on Recent Issues in Bioanalysis (8th WRIB), a 5-day full immersion in the evolving field of bioanalysis, took place in Universal City, California, USA. Close to 500 professionals from pharmaceutical and biopharmaceutical companies, contract research organizations and regulatory agencies worldwide convened to share, review, discuss and agree on approaches to address current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches and immunogenicity. From the prolific discussions held during the workshop, specific recommendations are presented in this 2014 White Paper. As with the previous years' editions, this paper acts as a practical tool to help the bioanalytical community continue advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2014 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for small molecule bioanalysis using LCMS. Part 2 (Hybrid LBA/LCMS, Electronic Laboratory Notebook and Regulatory Agencies' input) and Part 3 (Large molecules bioanalysis using LBA and Immunogenicity) will be published in the upcoming issues of Bioanalysis.


Asunto(s)
Bioensayo , Cromatografía Liquida/métodos , Espectrometría de Masas/métodos
15.
Bioanalysis ; 6(24): 3355-68, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25534792

RESUMEN

The 2014 8th Workshop on Recent Issues in Bioanalysis (8th WRIB), a 5-day full immersion in the evolving field of bioanalysis, took place in Universal City, California, USA. Close to 500 professionals from pharmaceutical and biopharmaceutical companies, contract research organizations and regulatory agencies worldwide convened to share, review, discuss and agree on approaches to address current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches and immunogenicity. From the prolific discussions held during the workshop, specific recommendations are presented in this 2014 White Paper. As with the previous years' editions, this paper acts as a practical tool to help the bioanalytical community continue advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2014 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 3) covers the recommendations for Large molecules bioanalysis using LBA and Immunogenicity. Part 1 (Small molecules bioanalysis using LCMS) and Part 2 (Hybrid LBA/LCMS, Electronic Laboratory Notebook and Regulatory Agencies' Input) were published in the Bioanalysis issues 6(22) and 6(23), respectively.


Asunto(s)
Técnicas de Química Analítica , Inmunidad , Anticuerpos Neutralizantes/inmunología , Biotransformación , Humanos , Preparaciones Farmacéuticas/metabolismo , Farmacocinética , Polietileno/química , Guías de Práctica Clínica como Asunto , Estados Unidos , United States Food and Drug Administration
16.
Bioanalysis ; 6(23): 3237-49, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25529890

RESUMEN

The 2014 8th Workshop on Recent Issues in Bioanalysis (8th WRIB), a 5-day full immersion in the evolving field of bioanalysis, took place in Universal City, California, USA. Close to 500 professionals from pharmaceutical and biopharmaceutical companies, contract research organizations and regulatory agencies worldwide convened to share, review, discuss and agree on approaches to address current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches and immunogenicity. From the prolific discussions held during the workshop, specific recommendations are presented in this 2014 White Paper. As with the previous years' editions, this paper acts as a practical tool to help the bioanalytical community continue advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2014 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations for Hybrid LBA/LCMS, Electronic Laboratory Notebook and Regulatory Agencies' Input. Part 1 (Small molecules bioanalysis using LCMS) was published in the Bioanalysis issue 6(22) and Part 3 (Large molecules bioanalysis using LBA and Immunogenicity) will be published in the Bioanalysis issue 6(24).


Asunto(s)
Técnicas de Laboratorio Clínico , Métodos Analíticos de la Preparación de la Muestra , Cromatografía Liquida , Humanos , Espectrometría de Masas
18.
Bioanalysis ; 6(6): 729-32, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24702107

RESUMEN

Crystal City V meeting on Quantitative Bioanalytical Method Validation and Implementation: 2013 Revised US FDA Guidance 3-5 December 2013, Hilton Baltimore, MD, USA The meeting provided an opportunity for Industry and regulators from the US FDA to discuss the recently published revised draft FDA Guidance for Industry on Bioanalytical Methods Validation during the 90 day review period. Key perspective and philosophical positions were shared leading to a healthy exchange of views and ideas on topics in the revised document. Discussions covered all aspects of bioanalytical method validation and method utilization. However, the main dialogue was focused on chromatographic methods, ligand-binding assay methods and biomarker analysis. The resulting open debate led to greater understanding of the document, but also provided clear feedback, including the request on harmonization with approved Bioanalytical Methods Validation guidance's release from other health authorities, as well as the consensus view between industry and the FDA. Members of the European Bioanalysis Forum summarized prospective discussions during the meeting in Baltimore; however, this Report is not intended to constitute the official proceedings from the meeting, which are expected to be published later this year.


Asunto(s)
Bioensayo/métodos , Cromatografía , Regulación Gubernamental , Humanos , Estados Unidos , United States Food and Drug Administration , Estudios de Validación como Asunto
19.
AAPS J ; 16(2): 194-205, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24343771

RESUMEN

As part of the GBC (Global Bioanalysis Consortium), the L3 assay format team has focused on reviewing common platforms used to support ligand binding assays in the detection of biotherapeutics. The following review is an overview of discussions and presentations from around the globe with a group of experts from different companies to allow an international harmonization of common practices and suggestions for different platforms. Some of the major platforms include Gyrolab, Erenna, RIA, AlphaLISA, Delfia, Immuno-PCR, Luminex, BIAcore, and ELISAs. The review is meant to support bioanalysts in taking decisions between different platforms depending on the needs of the analyte with a number of recommendations to help integration of platforms into a GLP environment.


Asunto(s)
Conducta Cooperativa , Guías de Práctica Clínica como Asunto , Ensayo de Inmunoadsorción Enzimática , Ligandos , Reacción en Cadena de la Polimerasa , Radioinmunoensayo
20.
Bioanalysis ; 5(2): 139-45, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23330557

RESUMEN

On 12-13 June 2012, the European Bioanalysis Forum hosted its third Focus Meeting in Brussels (Belgium). At the meeting, a panel discussion was held on the hurdles that the bioanalytical community encounters when adopting new technologies or managing regulated bioanalysis expectations around emerging technologies. Over the last few years, the industry has seen many new technologies maturing. As they became available, the bioanalytical scientist has observed that implementing these technologies in the regulated environment has become increasingly challenging. For one, scientific developments and regulatory expectations may not go hand in hand. At the same time, the pharmaceutical industry has become increasingly risk averse in their response to these real or perceived higher expectations in regulated bioanalysis. As a downstream consequence, the potential result of overinterpretation of guidance or occasional widespread and premature implementation of responses to health authority inspections, industry may be contributing significantly to raising the bar on some processes related to day-to-day practices in the bioanalytical laboratory. Last but not least, with the community being satisfied with the performance of the current tools, potential complacency can be observed in the regulated bioanalytical community because existing technologies, such as LC-MS/MS and ligand-binding assays, have served and still are serving them extremely well. Hence, the question 'what's next after LC-MS/MS or ELISA?' is not resonating with many scientists as pertinently compared with 'What's next after RIA, GC or LC-UV?', which was the key question in the 1990s, certainly in the context of an increasing effort needed to validate these new tools. With this article, the European Bioanalysis Forum aims to stimulate an open dialogue between all stakeholders in regulated bioanalysis to positively influence how we balance science, process and regulations in day-to-day work. This discussion should facilitate the evaluation and the subsequent implementation of innovative techniques for the benefit of the patient, while stimulating our community to raise the bar on added-value science, but at the same time removing the bar on processes with limited or no added value.


Asunto(s)
Química Farmacéutica/organización & administración , Industria Farmacéutica/organización & administración , Invenciones/tendencias , Química Farmacéutica/normas , Industria Farmacéutica/normas , Unión Europea , Humanos , Invenciones/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...