Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cardiovasc Diagn Ther ; 4(4): 299-306, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25276615

RESUMEN

BACKGROUND: This study aims to compare the image quality of second generation versus first generation 320-computed tomography coronary angiography (CTCA) in patients with heart rate ≥65 bpm as it has not been specifically reported. METHODS: Consecutive patients who underwent CTCA using second-generation-320-detector-row-CT were prospectively enrolled. A total of 50 patients with elevated (≥65 bpm) heart rate and 50 patients with controlled (<65 bpm) heart rate were included. Age and gender matched patients who were scanned with the first-generation-320-detector-row-CT were retrospectively identified. Image quality in each coronary artery segment was assessed by two blinded CT angiographers using the five-point Likert scale. RESULTS: In the elevated heart rate cohorts, while there was no significant difference in heart rate during scan-acquisition (66 vs. 69 bpm, P=0.308), or body mass index (28.5 vs. 29.6, P=0.464), the second generation scanner was associated with better image quality (3.94±0.6 vs. 3.45±0.8, P=0.001), and with lower radiation (2.8 vs. 4.3 mSv, P=0.009). There was no difference in scan image quality for the controlled heart rate cohorts. CONCLUSIONS: The second generation CT scanner provides better image quality at lower radiation dose in patients with elevated heart rate (≥65 bpm) compared to first generation CT scanner.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...