Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Food Chem ; 452: 139549, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38762939

RESUMEN

The prevention of pollution requires real-time monitoring of cadmium (Cd2+) concentration in the food, as it has a dramatic impact on poultry and can pose a threat to human health. Here, we fabricate a portable workstation integrating a microfluidic chip that facilitates real-time monitoring of Cd2+ levels in real samples by utilizing the Luminol-KMnO4 chemiluminescence (CL) system. Interestingly, Cd2+ can significantly enhance the CL signal, resulting in sensitive detection of Cd2+ in the range of 0-0.18 mg/L with the limit of detection (LOD) of 0.207 µg/L. Furthermore, a remote-controlled unit is integrated into the portable workstation to form a remote-controlled portable workstation (RCPW) performing automated point-of-care testing (POCT) of Cd2+. The as-prepared strategy allows remote control of RCPW to avoid long-distance transportation of samples to achieve real-time target monitoring. Consequently, this system furnishes RCPW for monitoring Cd2+ levels in real samples, thereby holding potential for applications in preventing food pollution.


Asunto(s)
Cadmio , Contaminación de Alimentos , Límite de Detección , Mediciones Luminiscentes , Cadmio/análisis , Contaminación de Alimentos/análisis , Mediciones Luminiscentes/instrumentación , Mediciones Luminiscentes/métodos , Animales , Luminiscencia , Pruebas en el Punto de Atención
2.
Micromachines (Basel) ; 15(4)2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38675366

RESUMEN

The Micromachines Editorial Office retracts the article "Preparation and analysis of structured color Janus droplets based on microfluidic 3D droplet printing" [...].

3.
Biosens Bioelectron ; 257: 116338, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38677017

RESUMEN

Foodborne pathogens have a substantial bearing on food safety and environmental health. The development of automated, portable and compact devices is essential for the on-site and rapid point-of-care testing (POCT) of bacteria. Here, this work developed a micro-automated microfluidic device for detecting bacteria, such as Escherichia coli (E. coli) O157:H7, using a seashell-like microfluidic chip (SMC) as an analysis and mixing platform. The automated device integrates a colorimetric/fluorescent system for the metabolism of copper (Cu2+) by E. coli affecting o-phenylenediamine (OPD) for concentration analysis. A smartphone was used to read the RGB data of the chip reaction reservoir to detect colorimetric and fluorescence patterns in the concentration range of 102-106 CFU mL-1. The automated device overcomes the low efficiency and tedious steps of traditional detection and enables high-precision automated detection that can be applied to POCT in the field, providing an ideal solution for broadening the application of E. coli detection.


Asunto(s)
Técnicas Biosensibles , Colorimetría , Cobre , Diseño de Equipo , Escherichia coli O157 , Microbiología de Alimentos , Dispositivos Laboratorio en un Chip , Pruebas en el Punto de Atención , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Escherichia coli O157/aislamiento & purificación , Humanos , Colorimetría/instrumentación , Cobre/química , Teléfono Inteligente/instrumentación , Enfermedades Transmitidas por los Alimentos/microbiología , Fenilendiaminas/química , Infecciones por Escherichia coli/microbiología , Contaminación de Alimentos/análisis
4.
Micromachines (Basel) ; 14(10)2023 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-37893348

RESUMEN

The microfluidic technique for the three-dimensional (3D) printing of Janus droplets offers precise control over their size, orientation, and positioning. The proposed approach investigates the impact of variables such as the volume ratio of the oil phase, droplet size, and the ratio of nonionic surfactants on the dimensions of the structured color apertures of Janus droplets. The findings reveal that structured color apertures modulate accurately. Furthermore, fabricating color patterns facilitates cat, fish, and various other specific shapes using structured color Janus droplets. The color patterns exhibit temperature-sensitive properties, enabling them to transition between display and concealed states. Herein, the adopted microfluidic technique creates Janus droplets with customizable characteristics and uniform size, solving orientation as well as space arrangement problems. This approach holds promising applications for optical devices, sensors, and biomimetic systems.

5.
Micromachines (Basel) ; 14(8)2023 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-37630113

RESUMEN

The market for microfluidic chips is experiencing significant growth; however, their development is hindered by a complex design process and low efficiency. Enhancing microfluidic chips' design quality and efficiency has emerged as an integral approach to foster their advancement. Currently, the existing structural design schemes lack careful consideration regarding the impact of chip area, microchannel length, and the number of intersections on chip design. This inadequacy leads to redundant chip structures resulting from the separation of layout and wiring design. This study proposes a structural optimization method for microfluidic chips to address these issues utilizing a simulated annealing algorithm. The simulated annealing algorithm generates an initial solution in advance using the fast sequence pair algorithm. Subsequently, an improved simulated annealing algorithm is employed to obtain the optimal solution for the device layout. During the wiring stage, an advanced wiring method is used to designate the high wiring area, thereby increasing the success rate of microfluidic chip wiring. Furthermore, the connection between layout and routing is reinforced through an improved layout adjustment method, which reduces the length of microchannels and the number of intersections. Finally, the effectiveness of the structural optimization approach is validated through six sets of test cases, successfully achieving the objective of enhancing the design quality of microfluidic chips.

6.
Foods ; 12(15)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37569137

RESUMEN

Food safety is a significant issue that affects people worldwide and is tied to their lives and health. The issue of pesticide residues in food is just one of many issues related to food safety, which leave residues in crops and are transferred through the food chain to human consumption. Foods contaminated with pesticide residues pose a serious risk to human health, including carcinogenicity, neurotoxicity, and endocrine disruption. Although traditional methods, including gas chromatography, high-performance liquid chromatography, chromatography, and mass spectrometry, can be used to achieve a quantitative analysis of pesticide residues, the disadvantages of these techniques, such as being time-consuming and costly and requiring specialist staff, limit their application. Therefore, there is a need to develop rapid, effective, and sensitive equipment for the quantitative analysis of pesticide residues in food. Microfluidics is rapidly emerging in a number of fields due to its outstanding strengths. This paper summarizes the application of microfluidic techniques to pyrethroid, carbamate, organochlorine, and organophosphate pesticides, as well as to commercial products. Meanwhile, the study also outlines the development of microfluidics in combination with 3D printing technology and nanomaterials for detecting pesticide residues in food.

7.
Micromachines (Basel) ; 14(7)2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37512588

RESUMEN

Gel fibers prepared based on microfluidic laminar flow technology have important research value in constructing biomimetic scaffolds and tissue engineering. The key point of microfluidic laminar flow technology is to find the appropriate fluid flow rate in the micropipe. In order to explore the influence of flow rate on the laminar flow phenomenon of a microfluidic chip, a microfluidic chip composed of an intermediate main pipe and three surrounding outer pipes are designed, and the chip is prepared by photolithography and the composite molding method. Then, a syringe pump is used to inject different fluids into the microtubing, and the data of fluid motion are obtained through fluid dynamics simulation and finite element analysis. Finally, a series of optimal adjustments are made for different fluid composition and flow rate combinations to achieve the fluid's stable laminar flow state. It was determined that when the concentration of sodium alginate in the outer phase was 1 wt% and the concentration of CaCl2 in the inner phase was 0.1 wt%, the gel fiber prepared was in good shape, the flow rate was the most stable, and laminar flow was the most obvious when the flow rate of both was 1 mL/h. This study represents a preliminary achievement in exploring the laminar flow rate and fabricating gel fibers, thus offering significant reference value for investigating microfluidic laminar flow technology.

8.
J Mater Chem B ; 11(9): 1978-1986, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36752153

RESUMEN

Since procalcitonin (PCT) is a specific inflammation indicator of severe bacterial inflammation and fungal infection, it is of great significance to construct a sensitive and rapid microfluidic chip to detect PCT in clinical application. The design of micromixers using a lab-on-a-chip (LOC) device is the premise to realizing the adequate mixing of analytical samples and reagents and is an important measure to improve the accuracy and efficiency of determination. In this research study, we investigate the mixing characteristics of hyperbolic micromixers and explore the effects of different hyperbolic curvatures, different Reynolds numbers (Re) and different channel widths on the mixing performance of the micromixers. Then, an optimal micromixer was integrated into a microfluidic chip to fabricate a desirable hyperbolic microfluidic chip (DHMC) for the sensitive determination of inflammation marker PCT with a limit of detection (LOD) as low as 0.17 ng mL-1via a chemiluminescence signal, which can be used as a promising real-time platform for early clinical diagnosis.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microfluídica , Humanos , Polipéptido alfa Relacionado con Calcitonina , Luminiscencia , Inflamación
9.
Micromachines (Basel) ; 13(8)2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-36014162

RESUMEN

A microfluidic chip is a tiny reactor that can confine and flow a specific amount of fluid into channels of tens to thousands of microns as needed and can precisely control fluid flow, pressure, temperature, etc. Point-of-care testing (POCT) requires small equipment, has short testing cycles, and controls the process, allowing single or multiple laboratory facilities to simultaneously analyze biological samples and diagnose infectious diseases. In general, rapid detection and stage assessment of viral epidemics are essential to overcome pandemic situations and diagnose promptly. Therefore, combining microfluidic devices with POCT improves detection efficiency and convenience for viral disease SARS-CoV-2. At the same time, the POCT of microfluidic chips increases user accessibility, improves accuracy and sensitivity, shortens detection time, etc., which are beneficial in detecting SARS-CoV-2. This review shares recent advances in POCT-based testing for COVID-19 and how it is better suited to help diagnose in response to the ongoing pandemic.

10.
Analyst ; 147(15): 3424-3433, 2022 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-35670058

RESUMEN

Since cancer has emerged as one of the most serious threats to human health, the highly sensitive determination of cancer cells is of significant importance to improve the accuracy of early clinical diagnosis. In our investigation, a novel cascade Fermat spiral microfluidic mixer chip (CFSMMC) combined with fluorescence sensors as a point-of-care (POC) testing system is successfully fabricated to detect and differentiate cancer cells (MCF-7) from normal cells with excellent sensitivity and selectivity. Here, copper ions (Cu2+) with peroxidase properties can catalyze the oxidation of the non-fluorescent substrate Amplex Red (AR) to the highly fluorescent resorufin (ox-AR) in the presence of hydrogen peroxide (H2O2). Subsequently, thanks to the quenching response of AS1411-AuNPs to ox-AR in the microchannel and the binding of AS1411 to nucleolin on the surface of cancer cells, a CFSMMC-based POC system is established for the highly sensitive detection and identification of human breast cancer cells in a "turn on" manner. The change in fluorescence intensity is linearly related to the concentration of MCF-7, ranging from 102 to 107 cells per mL with a limit of detection (LOD) as low as 17 cells per mL. Interestingly, the cascaded AND logic gate is integrated with CFSMMC for the first time to distinguish cancer cells from normal cells under the control of logic functions, which exhibits great potential in the development of one-step rapid and intelligent detection and logic discrimination.


Asunto(s)
Nanopartículas del Metal , Neoplasias , Oro , Humanos , Peróxido de Hidrógeno , Límite de Detección , Microfluídica
11.
Mil Med Res ; 9(1): 8, 2022 02 11.
Artículo en Inglés | MEDLINE | ID: mdl-35144683

RESUMEN

BACKGROUND: Early diagnosis and classification of infections increase the cure rate while decreasing complications, which is significant for severe infections, especially for war surgery. However, traditional methods rely on laborious operations and bulky devices. On the other hand, point-of-care (POC) methods suffer from limited robustness and accuracy. Therefore, it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements. METHODS: We developed a wave-shaped microfluidic chip (WMC) assisted multiplexed detection platform (WMC-MDP). WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents. We further combined the detection platform with the streptavidin-biotin (SA-B) amplified system to enhance the sensitivity while using chemiluminescence (CL) intensity as signal readout. We realized simultaneous detection of C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) on the detection platform and evaluated the sensitivity, linear range, selectivity, and repeatability. Finally, we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits. RESULTS: Detection of CRP, PCT, and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25-40 µg/ml, 0.4-12.8 ng/ml, and 50-1600 pg/ml, respectively. The limit of detection of CRP, PCT, and IL-6 were 0.54 µg/ml, 0.11 ng/ml, and 16.25 pg/ml, respectively. WMC-MDP is capable of good adequate selectivity and repeatability. The whole detection procedure takes only 22 min that meets the requirements of a POC device. Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits. CONCLUSIONS: WMC-MDP allows simultaneous, rapid, and sensitive detection of CRP, PCT, and IL-6 with satisfactory selectivity and repeatability, requiring minimal manipulation. However, WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10% enabling WMC-MDP to be a type of point-of-care testing (POCT). Therefore, WMC-MDP provides a promising alternative to POCT of multiple biomarkers. We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers.


Asunto(s)
Microfluídica , Pruebas en el Punto de Atención , Biomarcadores , Proteína C-Reactiva/análisis , Humanos , Sistemas de Atención de Punto
12.
ACS Omega ; 6(45): 30779-30789, 2021 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-34805706

RESUMEN

Micromixers with the microchannel structure can enable rapid and efficient mixing of multiple types of fluids on a microfluidic chip. Herein, we report the mixing performance of three passive micromixers based on the different mathematical spiral structures. We study the fluid flow characteristics of Archimedes spiral, Fermat spiral, and hyperbolic spiral structures with various channel widths and Reynolds number (Re) ranging from 0 to 10 via numerical simulation and visualization experiments. In addition, we analyze the mechanism of streamlines and Dean vortices at different cross sections during fluid flows. As the fluid flows in the Fermat spiral channel, the centrifugal force induces the Dean vortex to form a chaotic advection, enhancing the fluid mixing performance. By integrating the Fermat spiral channel into a microfluidic chip, we successfully detect acute myocardial infarction (AMI) marker with the double-antibody sandwich method and reduce the detection time to 10 min. This method has a low reagent consumption and a high reaction efficiency and demonstrates great potential in point-of-care testing (POCT).

13.
Micromachines (Basel) ; 12(11)2021 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-34832792

RESUMEN

Metal ions in high concentrations can pollute the marine environment. Human activities and industrial pollution are the causes of Cu2+ contamination. Here, we report our discovery of an enzyme method-based microfluidic that can be used to rapidly detect Cu2+ in seawater. In this method, Cu2+ is reduced to Cu+ to inhibit horseradish peroxidase (HRP) activity, which then results in the color distortion of the reaction solution. The chip provides both naked eye and spectrophotometer modalities. Cu2+ concentrations have an ideal linear relationship, with absorbance values ranging from 3.91 nM to 256 µM. The proposed enzyme method-based microfluidic chip detects Cu2+ with a limit of detection (LOD) of 0.87 nM. Other common metal ions do not affect the operation of the chip. The successful detection of Cu2+ was achieved using three real seawater samples, verifying the ability of the chip in practical applications. Furthermore, the chip realizes the functions of two AND gates in series and has potential practical implementations in biochemical detection and biological computing.

14.
Front Chem ; 9: 741058, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34671590

RESUMEN

Existing methods for detecting cardiac markers are difficult to be applied in point-of-care testing (POCT) due to complex operation, long time consumption, and low sensitivity. Here, we report a snail-shaped microfluidic chip (SMC) for the multiplex detection of cTnI, CK-MB, and Myo with high sensitivity and a short detection time. The SMC consists of a sandwich structure: a channel layer with a mixer and reaction zone, a reaction layer coated with capture antibodies, and a base layer. The opening or closing of the microchannels is realized by controlling the downward movement of the press-type mechanical valve. The chemiluminescence method was used as a signal readout, and the experimental conditions were optimized. SMC could detect cTnI, CK-MB, and Myo at concentrations as low as 1.02, 1.37, and 4.15. The SMC will be a promising platform for a simultaneous determination of multianalytes and shows a potential application in POCT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...