Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Heart J ; 44(40): 4259-4269, 2023 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-37632437

RESUMEN

BACKGROUND AND AIMS: De novo implanted cardiac resynchronization therapy with defibrillator (CRT-D) reduces the risk of morbidity and mortality in patients with left bundle branch block, heart failure and reduced ejection fraction (HFrEF). However, among HFrEF patients with right ventricular pacing (RVP), the efficacy of CRT-D upgrade is uncertain. METHODS: In this multicentre, randomized, controlled trial, 360 symptomatic (New York Heart Association Classes II-IVa) HFrEF patients with a pacemaker or implantable cardioverter defibrillator (ICD), high RVP burden ≥ 20%, and a wide paced QRS complex duration ≥ 150 ms were randomly assigned to receive CRT-D upgrade (n = 215) or ICD (n = 145) in a 3:2 ratio. The primary outcome was the composite of all-cause mortality, heart failure hospitalization, or <15% reduction of left ventricular end-systolic volume assessed at 12 months. Secondary outcomes included all-cause mortality or heart failure hospitalization. RESULTS: Over a median follow-up of 12.4 months, the primary outcome occurred in 58/179 (32.4%) in the CRT-D arm vs. 101/128 (78.9%) in the ICD arm (odds ratio 0.11; 95% confidence interval 0.06-0.19; P < .001). All-cause mortality or heart failure hospitalization occurred in 22/215 (10%) in the CRT-D arm vs. 46/145 (32%) in the ICD arm (hazard ratio 0.27; 95% confidence interval 0.16-0.47; P < .001). The incidence of procedure- or device-related complications was similar between the two arms [CRT-D group 25/211 (12.3%) vs. ICD group 11/142 (7.8%)]. CONCLUSIONS: In pacemaker or ICD patients with significant RVP burden and reduced ejection fraction, upgrade to CRT-D compared with ICD therapy reduced the combined risk of all-cause mortality, heart failure hospitalization, or absence of reverse remodelling.

2.
Clin Cardiol ; 46(8): 942-949, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37408170

RESUMEN

BACKGROUND: Catheter ablation is a rarely used procedure to treat arrhythmias during pregnancy. HYPOTHESIS: In the case of maternal arrhythmia during pregnancy, zero-fluoroscopic catheter ablation is preferable to medical treatment. METHODS: Between April 2014 and September 2021, we examined the demographic data, procedural parameters, and fetal and maternal outcomes in pregnant women undergoing ablation at the Gottsegen National Cardiovascular Center and University of Pécs Medical School, Heart Institute. RESULTS: Fourteen procedures (14 electrophysiological studies [EPS], 13 ablations) performed on 13 pregnant women (age 30.3 ± 5.2 years, primipara n = 6) were studied. During EPS, 12 patients had inducible arrhythmias. Atrial tachycardia was confirmed in three, atrioventricular re-entry tachycardia via manifest accessory pathway (AP) in three, and via concealed AP in one case. Atrioventricular nodal re-entry tachycardia was confirmed in three and sustained monomorphic ventricular tachycardia in two cases. Eleven radiofrequency ablation (84.6%) and two cryoablation (15.4%) were performed. The electroanatomical mapping system was used in all cases. Transseptal puncture was performed in two cases (15.4%) due to left lateral APs. The mean procedure time was 76.0±33.0 minutes. All procedures were performed without fluoroscopy. No complications occurred. During the follow-up, arrhythmia-free survival was achieved in all cases, but in two patients, we used antiarrhythmic drugs (AADs) to achieve it. APGAR score was within the normal range in all cases [median (interquartile range), 9.0/10.0 (9.0-10.0/9.3-10.0)]. CONCLUSIONS: Zero-fluoroscopic catheter ablation was an effective and safe treatment option for our 13 pregnant patients. Catheter ablation may have less side effects on fetal development than the use of AADs during pregnancy.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Femenino , Embarazo , Adulto , Mujeres Embarazadas , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Arritmias Cardíacas/etiología , Taquicardia Ventricular/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Resultado del Tratamiento
3.
Orv Hetil ; 164(4): 140-147, 2023 Jan 29.
Artículo en Húngaro | MEDLINE | ID: mdl-36709438

RESUMEN

INTRODUCTION: Left common pulmonary vein is the most common anatomical variant of pulmonary veins that may affect the outcome of pulmonary vein isolation. OBJECTIVE: Our aim was to compare procedural data and outcomes in patients with common trunk versus normal left atrial anatomy for radiofrequency and cryoballoon catheter ablation. METHOD: Data from patients who underwent pulmonary vein isolation for atrial fibrillation and had a preprocedural cardiac CT scan at our Institution between 01. 10. 2019 and 10. 03. 2022 were retrospectively evaluated. We defined a common trunk where the left superior and inferior pulmonary vein merged at least 5 mm before the left atrial ostium. RESULTS: From the study population (n = 210), data from 42 patients with a left common trunk (LCPV group) and 60 patients with normal left atrial anatomy (control group) were examined. No significant differences were found between the common trunk and the control group in terms of demographic data. There was no significant difference between the two groups in procedural data for radiofrequency and cryoballoon ablation (procedure time, fluoroscopy time, left atrial dwelling time, radiation dose). After radiofrequency ablation, the success rate at 1-year follow-up was 72.0% in the common trunk group and 76.2% in the control group (p = 0.659). For cryoballoon ablation, the success rate was 64.7% and 69.2% for common trunk and normal anatomy, respectively (p = 0.641). CONCLUSION: There was no significant difference in the procedural parameters and clinical outcome between patients with left common pulmonary vein and those with normal left atrial anatomy. Both radiofrequency and cryoballoon ablation techniques are well suited for this population. Orv Hetil. 2023; 164(4): 140-147.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Pronóstico , Resultado del Tratamiento , Estudios Retrospectivos , Criocirugía/efectos adversos , Criocirugía/métodos , Ablación por Catéter/métodos , Recurrencia
4.
J Cardiovasc Dev Dis ; 9(10)2022 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-36286279

RESUMEN

This randomized study aims to compare the left atrial (LA) lesion size, function, and tissue damage following pulmonary vein isolation (PVI) by high-power short-duration (HPSD) radiofrequency (RF) and second-generation cryoballoon (CB2) ablation. We enrolled 40 patients with paroxysmal atrial fibrillation who underwent PVI by HPSD RF (n = 21) or CB2 (n = 19). Every patient underwent LA CT angiography and transthoracic echocardiography (TTE) to assess the LA anatomy and function. Biomarker levels (hs-cTnT, hs-CRP, LDH) were compared pre- and post-procedurally. Pre- and post-ablation high-density mapping (HDM) was performed. The isolation area was defined under 0.2 mV bipolar voltage (low voltage area, LVA). We calculated the post-PVI LVA/LA surface ratio using LA CT-HDM merge images. At 3-month follow-up, TTE was performed to assess the changes in LA function. Post-ablation hs-cTnT level was significantly higher in the RF group (RF: 1249 ± 469 ng/L, CB2: 995 ± 280 ng/L, p = 0.024). Post-PVI hs-CRP (RF: 9.53 ± 10.30 mg/L, CB2: 12.36 ± 5.76 mg/L, p = 0.034) and LDH levels (RF: 349.9 ± 65.6 U/L, CB2: 451.6 ± 91.3 U/L, p < 0.001) were significantly higher following CB2 ablation. Post-PVI LVA/LA surface ratios were 8.37 ± 6.42% in the RF group and 13.58 ± 8.92% in the CB2 group (p = 0.022). LA function did not change significantly after the PVI procedure. Our data indicate that second-generation cryoballoon ablation produces a significantly larger LA lesion size compared to "point-by-point" HPSD radiofrequency. Both techniques preserve LA function. The myocardial component of tissue loss appears to be higher using HPSD radiofrequency ablation, with less collateral damage.

5.
Orv Hetil ; 161(46): 1953-1958, 2020 11 15.
Artículo en Húngaro | MEDLINE | ID: mdl-33190126

RESUMEN

Összefoglaló. Bevezetés: Az inadekvát, aránytalan sinuscsomó-tachycardia a szív nomotop ingerképzési zavarával járó, nem ritka klinikai szindróma. A szívritmuszavar-entitást a nem paroxysmalis, magas nyugalmi sinusfrekvencia, a fizikai/pszichés stresszre adott aránytalan sinustachycardia, valamint foként palpitációs panaszok jellemzik. Célkituzés: Az aránytalan sinuscsomó-tachycardiás betegeink gyógyszeres kezelésével szerzett tapasztalataink ismertetése. Módszerek: 2008 és 2018 között 104 beteget (92 no, 12 férfi; átlagéletkor 31 ± 10 év) kezeltünk ezzel a szívritmuszavarral. A betegek kivizsgálásuk után 12 elvezetéses EKG-, terheléses EKG-, valamint 24 órás Holter-monitoros EKG-megfigyeléseken vettek részt a gyógyszeres kezelés elott és után (bizoprolol: 2 × 5 mg/nap; ivabradin: 2 × 5 mg/nap). Az életminoség változását a European Heart Rhythm Association (EHRA) tüneti skálája szerint állapítottuk meg. Eredmények: Mindkét gyógyszer jelentosen csökkentette a nyugalmi sinusfrekvenciát (kontroll: 102 ± 10/min; bizoprolol: 78 ± 6/min; ivabradin: 74 ± 8/min, mindketto: p<0,0001). A gyógyszeres kezelés nélküli, 24 órás Holter-monitoros EKG-felvételek során mért szívfrekvenciák (minimum-maximum [átlag] sinusfrekvencia/min) a kontrollértékekrol (58 ± 8-159 ± 14 [94 ± 6]/min) mindkét gyógyszerre egyaránt szignifikánsan csökkentek (bizoprolol: 53 ± 7-132 ± 13 [77 ± 9]/min [mindhárom: p<0,0001]; ivabradin 51 ± 6-134 ± 18 [77 ± 8]/min [mindhárom: p<0,0001]). A terheléses EKG-vizsgálatok elott (kontroll: 99 ± 13/min; bizoprolol 81 ± 11/min [p<0,0001]; ivabradin: 84 ± 10/min [p<0,0001]) és a terhelés csúcspontján mért sinusfrekvenciák (kontroll: 164 ± 15/min; bizoprolol: 140 ± 16/min [p<0,0001]; ivabradin: 142 ± 14/min [p<0,0001]) is jelentosen mérséklodtek. Az azonos dózisban adott két gyógyszer szívfrekvencia-csökkento hatásai között számottevo különbséget nem tapasztaltunk. Az életminoséget tükrözo EHRA tüneti skálán (kontroll: 2,3 ± 0,7) mind a bizoprolol (1,4 ± 1,4; p<0,0001), mind az ivabradin (1,1 ± 0,2; p<0,0001) egyformán csökkentette a betegek tüneteit, panaszait. Számottevo cardiovascularis mellékhatás egyik betegcsoportban sem jelentkezett. Következtetések: Vizsgálati eredményeink alapján megállapítható, hogy az aránytalan sinuscsomó-tachycardiás betegek gyógyszeres kezelésére: (1) a kardiospecifikus adrenerg béta-blokkoló bizoprolol és az If-csatorna-gátló ivabradin egyaránt hatékonynak és biztonságosnak bizonyult; (2) az azonos adagban adott két gyógyszer hatékonysága között számottevo különbség nem volt; (3) a gyógyszeres kezelés nemcsak a sinusfrekvenciát csökkentette, hanem a betegek panaszait, tüneteit is mérsékelte. Orv Hetil. 2020; 161(46): 1953-1958. INTRODUCTION: The inadequate, inappropriate sinus-node tachycardia is not a rare clinical syndrome, defined as a disturbance of the nomotopic impulse formation of the heart. This cardiac arrhythmic entity is characterized by a non-paroxismal, increased sinus rate at rest, and/or inadequate response to physical and/or emotional stress and palpitations. OBJECTIVE: The aim of this study was to describe our experiences with pharmacological therapy of patients with inappropriate sinus tachycardia syndrome. METHODS: Between 2008 and 2018, 104 patients (92 women, 12 men, mean age: 31 ± 10 years) were treated with this cardiac arrhythmia entity. All patients underwent 12-lead ECG, 24-hour Holter-ECG monitoring and standard bicycle dynamic exercise tests before and after drug treatment (bisoprolol: 5 mg bid; ivabradine: 5 mg bid). Changes in the quality of life were estimated by using the European Heart Rhythm Association (EHRA) score. RESULTS: Both drugs decreased significantly the resting heart rate (control: 102 ± 10/min; bisoprolol 78 ± 6/min (p<0.0001), ivabradine: 74 ± 8/min (p<0.0001). The results of the parameters of the 24-hour Holter ECG recordings (expressed as minimal-maximal [average] heart rate/min) with drug therapy showed a significant decrease from control values in all three parameters: control 58 ± 8-159 ± 14 (94 ± 6)/min; bisoprolol 53 ± 7-132 ±13 (77 ± 9)/min (all three: p<0.0001); ivabradine: 51 ± 6-134 ± 18 (77 ± 8)/min (all three: p<0.0001). The sinus rate reduced significantly both before the bicycle dynamic exercise tests (control: 99 ± 13/min; bisoprolol: 81 ± 11/min [p<0.0001]; ivabradine: 84 ± 10/min [p<0.0001]) and at the peaks of the exercise test (control: 164 ± 15/min; bisoprolol: 140 ± 16/min [p<0.0001]; ivabradine 142 ± 14/min [p<0.0001]). The heart rate reducing effects of the two drugs did not differ significantly. The EHRA quality of life score was equally improved by the two drugs (control: 2.3 ± 0.7; bisoprolol: 1.4 ± 1.4 [p<0.0001]; ivabradine: 1.1 ± 0.2 [p<0.0001]). No cardiovascular side effects were observed while taking bisoprolol or ivabradine. CONCLUSIONS: Based on our clinical results, it can be pointed out that in the drug therapy of patients with inappropriate sinus node tachycardia: (1) bisoprolol (5 mg bid) and ivabradine (5 mg bid) proved to be equally effective and safe; (2) the heart rate reducing effect of the two drugs - given in the same dosage - did not differ considerably; (3) the pharmacological therapy significantly decreased not only the sinus frequency, but also reduced the symptoms of the patients. Orv Hetil. 2020; 161(46): 1953-1958.


Asunto(s)
Calidad de Vida , Taquicardia Sinusal , Adulto , Arritmias Cardíacas/tratamiento farmacológico , Electrocardiografía , Electrocardiografía Ambulatoria , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Taquicardia Sinusal/tratamiento farmacológico , Resultado del Tratamiento , Adulto Joven
6.
Orv Hetil ; 160(37): 1464-1470, 2019 Sep.
Artículo en Húngaro | MEDLINE | ID: mdl-31495186

RESUMEN

Introduction: The inadequate, inappropriate sinus-node tachycardia is not a rare clinical syndrome, defined as a non-paroxysmal, increased sinus-rate at rest, and/or inadequate response to physical and/or emotional stress, and palpitations. Aim: The aim of this study was to describe our experiences with the investigations of our inappropriate sinus-node tachycardia patients. Method: In the last years, 104 patients (92 women, 12 men, mean age: 31 ± 10 years) were treated with this cardiac arrhythmia entity. All patients underwent 12 leads ECG, chest X-ray, echocardiography, Holter-monitoring and transtelephonic ECG observations. The quality of life score was estimated by using the European Heart Rhythm Association scale. Results: Patients had no structural heart disease (physical examination ECG, chest X-ray, echocardiography were normal), the laboratory values (TSH, blood count) were within normal limits, but the resting heart rates were repeatedly high (102 ± 8/min). The results of Holter recording (expressed as minimal-maximal [average] heart rate/min) without drug therapy showed high heart rate values (59 ± 8, 160 ± 14 [94 ± 6]/min). The standard bicycle ergometry showed an average loading capacity of 124 ± 23 watt (heart rate: control: 99 ± 12/min, top: 167 ± 13/min) with early, inadequate sinus tachycardia. To disclose the episodes of paroxysmal supraventricular tachycardia, beside the Holter-monitoring transtelephonic ECG system was used. This diagnostic modality was very useful for the exclusion of paroxysmal supraventricular tachycardia episodes during the palpitation symptoms. Out of 104 patients, 4 patients (3.8%) showed familiar occurrence, another 16 patients (15.2%) had previous slow-pathway radiofrequency ablation due to atrioventricular nodal reentry tachycardia. Conclusions: Based on our clinical observations, it can be pointed out that inappropriate sinus-node tachycardia syndrome (1) occurs mainly in young women, mostly in students, inducing decreased quality of life scores (EHRA score: 2.3 ± 0.4); (2) the prevalence in our outpatient clinic was 0.7%; (3) the patient population is not homogeneous: familiar or postablation occurrence is possible in some patients; (4) transtelephonic ECG has been proved to be very useful to disclose episodes of paroxysmal supraventricular tachycardia in these patients. Orv Hetil. 2019; 160(37): 1464-1470.


Asunto(s)
Ablación por Catéter , Nodo Sinoatrial/cirugía , Taquicardia Sinusal/cirugía , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Adulto , Arritmias Cardíacas , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Nodo Sinoatrial/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/fisiopatología
7.
J Interv Card Electrophysiol ; 56(1): 19-27, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31399921

RESUMEN

PURPOSE: Iatrogenic atrial septal defect (IASD) after catheter ablation (CA) for atrial fibrillation (AF) due to transseptal puncture (TSP) can occur. The aim of this prospective study was to describe the incidence of IASD and to detect any cerebrovascular accident (CVA) after radiofrequency (RF) and cryoballoon (CB) CA. METHODS: Between July 2014 and September 2016, 94 patients (pts) (RF; 48, CB; 46, 30 (31.9%) women, mean age = 60 ± 9.7 years) with paroxysmal AF were enrolled who underwent CA procedure for the first time. During RF ablation a single (n = 30, 62.5%) or double (n = 18, 37.5%) TSP was performed. Transoesophageal echocardiography before the procedure and at the 3-month and 12-month follow-up (FU) was accomplished. During the FU period, we evaluated the occurrence of any postprocedural CVA. RESULTS: At the 3-month FU, IASD was detected in 17/94 (18.1%) pts; in 9/48 (18.8%) pts in the RF while in 8/46 (17.4%) pts in the CB group (p = 0.866), all of them with left-to-right shunt. In the RF group, 6/30 (20%) pts with a single TSP while 3/18 (16.7%) pts in the double TSP group had IASD (p = 0.780). 14/17 (82.4%) IASDs showed high spontaneous closure rate at the 12-month FU. None of the pts died or suffered from CVA. CONCLUSION: Persistent IASD can occur rather frequently following AF CA. No significant difference was observed between the RF and CB techniques concerning the presence of IASD at 3-month. IASDs showed a high spontaneous closure rate. No cerebral thromboembolic event was observed in the 12-month FU period.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Defectos del Tabique Interatrial/etiología , Enfermedad Iatrogénica , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
8.
Orv Hetil ; 158(27): 1067-1070, 2017 Jul.
Artículo en Húngaro | MEDLINE | ID: mdl-28670989

RESUMEN

Sarcoidosis is a systemic granulomatous disease of unknown aetiology, which is characterized by bilateral hilar lymphadenopathy and pulmonary disease. Clinically detected cardiac involvement occurs in 5% of sarcoid patients, although cardiac manifestations are discovered in 25% of the cases at autopsy. Sarcoid heart disease frequently causes atrioventricular block. The authors present the case of a 44-year-old man with bradycardia. On admission, second degree Mobitz II, then third degree atrioventricular block was diagnosed. Coronarography showed normal coronary arteries. 2.5 years following artificial Biotronik Entovis DR type pacemaker implantation, sudden cardiac death occurred. Autopsy revealed sarcoidosis with cardiac, pulmonary, splenic, renal and lymph node involvement. In case of young or middle-aged patients with atrioventricular block, it is best to search for other causes if the most common coronary origin can be excluded. Orv Hetil. 2017; 158(27): 1067-1070.


Asunto(s)
Cardiomiopatías/patología , Muerte Súbita Cardíaca/patología , Sarcoidosis/patología , Nodo Atrioventricular/patología , Cardiomiopatías/complicaciones , Resultado Fatal , Humanos , Masculino , Persona de Mediana Edad , Sarcoidosis/complicaciones
9.
Biomed Res Int ; 2016: 6495753, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27314032

RESUMEN

Background. There are little comparative data on catheter ablation of paroxysmal atrial fibrillation (AF) using the contact force radiofrequency (CF-RF) catheter versus the second-generation cryoballoon (CB2). Methods and results. This is a single center, retrospective, nonrandomized study of 98 patients with symptomatic, drug-refractory paroxysmal AF who underwent their first PVI ablation using either the CB2 (n = 40) or CF-RF (n = 58). The mean age was 60 years with 63% men, a mean LA size of 42 mm. The procedure duration (74 ± 17 versus 120 ± 49 minutes p < 0.05) was shorter for CB2 group; the fluoroscopy time (14 ± 17 versus 16 ± 5 minutes, p = 0.45) was similar. Complete PVI was achieved in 96% of patients with RF-CF and 98% with CB2. Phrenic nerve palsies (2 transient and 1 persistent) occurred exclusively in the CB2 group and 1 severe, nonlethal complication (pericardial tamponade) occurred in the CF-RF group. At 24-month follow-up, the success rate, defined as freedom from AF/atrial tachycardia (AT) after a single procedure without antiarrhythmic drug, was comparable in CF-RF group and CB2 group (65.5% versus 67%, resp., log rank p = 0.54). Conclusion. Both the CB2 and the RF-CF ablation appeared safe; the success rate at 2 years was comparable between both technologies.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Criocirugía/métodos , Anciano , Anticoagulantes/uso terapéutico , Femenino , Fluoroscopía , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Ondas de Radio , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
Orv Hetil ; 157(22): 849-54, 2016 May 29.
Artículo en Húngaro | MEDLINE | ID: mdl-27211354

RESUMEN

INTRODUCTION: Contact force sensing radiofrequency ablation and the new generation cryoballoon ablation are prevalent techniques for the treatment of paroxysmal atrial fibrillation. AIM: The authors aimed to compare the procedural and 1-year outcome of patients after radiofrequency and cryoballoon ablation. METHOD: 96 patients with paroxysmal atrial fibrillation (radiofrequency ablation: 58, cryoballoon: 38 patients; 65 men and 31 women aged 28-70 years) were enrolled. At postprocedural 1, 3, 6 and 12 months ECG, Holter monitoring and telephone interviews were performed. RESULTS: Procedure and fluorosocopy time were: radiofrequency ablation, 118.5 ± 15 min and 15.8 ± 6 min; cryoballoon, 73.5 ± 16 min (p<0.05) and 13.8 ± 4.,1 min (p = 0.09), respectively. One year later freedom from atrial fibrillation was achieved in 76.5% of patients who underwent radiofrequency ablation and in 81% of patients treated with cryoballoon. Temporary phrenic nerve palsy occurred in two patients and pericardial tamponade developed in one patient. CONCLUSIONS: In this single center study freedom from paroxysmal atrial fibrillation was similar in the two groups with significant shorter procedure time in the cryoballoon group.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Criocirugía/métodos , Electrocardiografía , Electrocardiografía Ambulatoria , Femenino , Fluoroscopía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Dosis de Radiación , Recurrencia , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
11.
Orv Hetil ; 154(7): 262-5, 2013 Feb 17.
Artículo en Húngaro | MEDLINE | ID: mdl-23395790

RESUMEN

The "gold standard" of the prevention of atrial fibrillation related thromboembolic events is anticoagulation therapy with oral vitamin K antagonists. A certain proportion of high-risk patients with atrial fibrillation are not receiving effective antithrombotic therapy because of problems associated with its use. Resolution of subsequent left atrial appendage thrombi is quite a great challenge in patients who are not tolerating "standard" antithrombotic drugs. According to the knowledge of the authors, this is the first report of a patient with non-valvular persistent atrial fibrillation and high stroke risk, who was intolerant to "standard" anticoagulant therapy and had persistent left atrial appendage thrombi following the use of a wide variety of "standard" anticoagulants. Successful resolution of left atrial appendage thrombi with dabigatran and successful percutaneous left atrial appendage closure were performed in this case.


Asunto(s)
Antitrombinas/uso terapéutico , Aterectomía , Apéndice Atrial , Fibrilación Atrial/terapia , Bencimidazoles/uso terapéutico , Trombosis/tratamiento farmacológico , beta-Alanina/análogos & derivados , Anticoagulantes/administración & dosificación , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/patología , Fibrilación Atrial/diagnóstico por imagen , Comorbilidad , Dabigatrán , Ecocardiografía Transesofágica , Femenino , Heparina de Bajo-Peso-Molecular/administración & dosificación , Humanos , Persona de Mediana Edad , Obesidad Mórbida/complicaciones , Factores de Riesgo , Accidente Cerebrovascular/prevención & control , Trombosis/diagnóstico por imagen , Resultado del Tratamiento , beta-Alanina/uso terapéutico
12.
Orv Hetil ; 149(38): 1779-84, 2008 Sep 21.
Artículo en Húngaro | MEDLINE | ID: mdl-18805763

RESUMEN

Atrial fibrillation is the most frequent arrhythmia with increasing prevalence. Given a limited success rate of drug therapy for atrial fibrillation, interventional treatment options have been developed during the last years. Catheter ablation of atrial fibrillation (until recently the mostly used energy source was radiofrequency energy) has been established as an important therapeutic alternative. Depending on interpersonal (both on patient and operator side) and technical variabilities using radiofrequency energy potentially life-threatening complications such as pulmonary vein stenosis or atrio-esophageal fistulas may occur. Cryoenergy is a novel energy source for transcatheter ablation eliminating the arrhythmia substrate by freezing. The cornerstone of catheter ablation for atrial fibrillation is electrical isolation of the pulmonary veins. During cryoballoon ablation the targeted pulmonary vein transiently occluded by the inflated balloon catheter and using this method a circumferential lesion is created. The success rate of cryoballoon ablation is comparable with the radiofrequency ablation with increased safety. We performed the first cryoballoon ablations for patients with paroxysmal atrial fibrillation in Hungary. On this occasion we review the potential advantages of this technique which may serve as basis for its widespread use in the future.


Asunto(s)
Fibrilación Atrial/terapia , Cateterismo/métodos , Criocirugía/métodos , Venas Pulmonares , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrofisiología , Humanos , Hungría , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...