Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Gastrointest Endosc ; 77(3): 319-27, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23410693

RESUMEN

Biliary and pancreatic stents are used in a variety of benign and malignant conditions including strictures and leaks and in the prevention of post-ERCP pancreatitis.Both plastic and metal stents are safe, effective, and easy to use. SEMSs have traditionally been used for inoperable malignant disease. Covered SEMSs are now being evaluated for use in benign disease. Increasing the duration of patency of both plastic and metal stents remains an important area for future research.


Asunto(s)
Enfermedades de las Vías Biliares/cirugía , Enfermedades Pancreáticas/cirugía , Stents , Colangiopancreatografia Retrógrada Endoscópica , Diseño de Equipo , Humanos , Metales , Plásticos , Stents/efectos adversos , Stents/economía
6.
Gastrointest Endosc ; 76(1): 1-7, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22579259

RESUMEN

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of new or emerging endoscopic technologies that have the potential to have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent preclinical and clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. For this review, the MEDLINE database was searched through January 2011 using the keywords "bariatric," "endoscopic," "intragastric balloon," "duodenojejunal bypass sleeve," and "transoral gastroplasty." Reports on Emerging Technologies are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. These reports are scientific reviews provided solely for educational and informational purposes. Reports on Emerging Technologies are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Asunto(s)
Endoscopía Gastrointestinal/métodos , Balón Gástrico , Obesidad/terapia , Prótesis e Implantes , Toxinas Botulínicas/uso terapéutico , Endoscopía Gastrointestinal/instrumentación , Humanos , Neurotoxinas/uso terapéutico
11.
Gastrointest Endosc ; 74(3): 455-64, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21762904

RESUMEN

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2010 for articles related to enteral, esophageal, duodenal, and colonic stents. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Asunto(s)
Enfermedades Gastrointestinales/terapia , Stents , Humanos , Stents/efectos adversos , Stents/economía
13.
Gastrointest Endosc ; 73(3): 423-7, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21237458

RESUMEN

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of new or emerging endoscopic technologies that have the potential to have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent preclinical and clinical studies on the topic, and a MAUDE (Manufacturer and User Facility Device Experience; U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized but, in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. For this review, the MEDLINE database was searched through January 2010 using the keywords "computer," "computerized," "computer-assisted," "sedation," "propofol." Reports on Emerging Technology are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. These reports are scientific reviews provided solely for educational and informational purposes. Reports on Emerging Technology are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Asunto(s)
Colonoscopía , Sedación Consciente/instrumentación , Sistemas de Liberación de Medicamentos/instrumentación , Monitoreo de Drogas/instrumentación , Propofol , Computadores , Sedación Consciente/métodos , Aprobación de Recursos , Humanos , Enfermeras y Enfermeros , Médicos , Programas Informáticos , Estados Unidos , United States Food and Drug Administration
14.
Gastrointest Endosc ; 72(2): 227-35, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20537638

RESUMEN

The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, by using a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2009 for articles related to personal protection equipment by using the key words "personal protection equipment" (exp Protective Clothing/ or exp Protective Devices/ or exp Masks/ or exp Occupational Exposure/'') "infection control" paired with "Endoscopy." For the radiation section, the following key words were used: "radiation and endoscopy," "radiation and ERCP," and "radiation safety." For the ergonomics section, the following key words were used: "ergonomics of endoscopy," "endoscopist injury," "medical ergonomics," "endoscopy and musculoskeletal strain," "musculoskeletal injury and endoscopists," "occupational diseases and endoscopy," "cumulative trauma disorder and endoscopy," "repetitive strain injury and endoscopy." Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Asunto(s)
Endoscopios/normas , Endoscopía/normas , Ergonomía/métodos , Exposición Profesional/prevención & control , Equipos de Seguridad/normas , Liberación de Radiactividad Peligrosa/prevención & control , Administración de la Seguridad/métodos , Seguridad de Equipos , Humanos
15.
Gastrointest Endosc ; 72(2): 236-48, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20541746

RESUMEN

The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but, in many cases, data from randomized, controlled trials are lacking. In such situations, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the ASGE Governing Board. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2009 for articles related to endoscopy in patients requiring enteral feeding access by using the keywords "endoscopy," "percutaneous," "gastrostomy," "jejunostomy," "nasogastric," "nasoenteric," "nasojejunal," "transnasal," "feeding tube," "enteric," and "button." Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Asunto(s)
Endoscopios Gastrointestinales/normas , Nutrición Enteral/instrumentación , Yeyunostomía/instrumentación , Diseño de Equipo , Humanos
17.
Gastrointest Endosc ; 70(1): 9-17, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19394009

RESUMEN

BACKGROUND: Autofluorescence imaging is a novel imaging technique that may improve the detection of early neoplasia in Barrett's esophagus. Autofluorescence imaging is, however, associated with a 40% to 81% false-positive rate. OBJECTIVE: Our purpose was to identify endoscopic features that may predict the presence of early neoplasia in autofluorescence-positive areas. DESIGN: Descriptive and prospective cohort study. SETTING: Tertiary referral centers for the detection and treatment of early Barrett's neoplasia. PATIENTS AND METHODS: Patients undergoing autofluorescence endoscopy. High-quality images with autofluorescence imaging and white-light endoscopy were obtained with corresponding histologic study. A systematic image evaluation process was performed, including an unblinded orientation phase (10 areas), a blinded derivation phase, and a blinded validation phase by 5 international experts in autofluorescence imaging (80 areas). Subsequently the identified features were validated in a prospective pilot study. MAIN OUTCOME MEASUREMENTS: Association between endoscopic features and presence of early neoplasia in autofluorescence-positive areas. RESULTS: Autofluorescence intensity, proximity of gastric folds <1 cm, and different appearance on white-light endoscopy were independently associated with early neoplasia in autofluorescence-positive areas on multivariate analysis. The kappa values for interobserver agreement of these factors were moderate, ranging between 0.49 to 0.56. The association with autofluorescence intensity and different appearance on white-light endoscopy was confirmed in a prospective pilot study. LIMITATION: Selected set of images from a high-risk population (tertiary referral center). CONCLUSION: We found specific endoscopic features that were associated with early neoplasia in autofluorescence-positive areas. These findings can be used in future prospective studies to improve the accuracy of autofluorescence imaging without performing magnification endoscopy for detailed inspection of suspicious areas.


Asunto(s)
Esófago de Barrett/diagnóstico , Endoscopía Gastrointestinal/métodos , Neoplasias Esofágicas/diagnóstico , Fluorescencia , Mucosa Intestinal/patología , Medición de Riesgo/métodos , Anciano , Esófago de Barrett/complicaciones , Esófago de Barrett/epidemiología , Biopsia , Diagnóstico Diferencial , Neoplasias Esofágicas/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Países Bajos/epidemiología , Proyectos Piloto , Prevalencia , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Método Simple Ciego , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...