Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
J Chest Surg ; 57(3): 289-290, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38695115
2.
J Clin Med ; 13(4)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38398272

RESUMEN

BACKGROUND: Myocardial injury after non-cardiac surgery (MINS) has been known to be associated with mortality in various surgical patients; however, its prognostic role in abdominal aortic aneurysm (AAA) open repair remains underexplored. This study aimed to investigate the role of MINS as a predictor of mortality in patients who underwent AAA open repair. METHODS: This retrospective study investigated 352 patients who underwent open repair for non-ruptured AAA. The predictors of 30-day and 1-year mortalities were investigated using logistic regression analysis. RESULTS: MINS was diagnosed in 41% of the patients after AAA open repair in this study. MINS was an independent risk factor of 30-day mortality (odds ratio [OR]: 10.440, 95% confidence interval [CI]: 1.278-85.274, p = 0.029) and 1-year mortality (OR: 5.189, 95% CI: 1.357-19.844, p = 0.016). Kaplan-Meier survival curves demonstrated significantly lower overall survival rates in patients with MINS compared to those without MINS (p = 0.003). CONCLUSION: This study revealed that MINS is a common complication after AAA open repair and is an independent risk factor of 30-day and 1-year mortalities. Patients with MINS have lower overall survival rates than those without MINS.

3.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38238991

RESUMEN

OBJECTIVES: In this cohort study, we aimed to assess the 1-year clinical outcomes of using the E-vita Open NEO™ hybrid prosthesis for total arch replacement with frozen elephant trunk (FET) to repair extensive aortic pathologies. METHODS: We reviewed individuals who underwent thoracic aortic surgery between April 2021 and March 2023 from the Gangnam Severance Aortic Registry. Exclusion criteria included ascending aortic replacement, 1 or 2 partial arch replacement, descending aortic replacement and total arch replacement without an FET. Finally, all consecutive patients who underwent total arch replacement and FET with E-vita Open NEO for aortic arch pathologies between April 2021 and March 2023 were included in this cohort study. The patients were divided into 3 groups based on their pathology: acute aortic dissection, chronic aortic dissection and thoracic aortic aneurysm. The primary end point was in-hospital mortality. The secondary end points during the postoperative period comprised stroke, spinal cord injury and redo sternotomy for bleeding. Additionally, the secondary end points during the follow-up period included the 1-year survival rate, 1-year freedom from all aortic procedures and 1-year freedom from unplanned aortic interventions. RESULTS: The study included 167 patients in total: 92 patients (55.1%) with acute aortic dissection, 20 patients (12.0%) with chronic aortic dissection and 55 patients (32.9%) with thoracic aortic aneurysm. The in-hospital mortality was 1.8% (n = 3). Strokes occurred in 1.8% (n = 3) of the patients, spinal cord injury in 1.8% (n = 3) and redo sternotomy for bleeding was performed in 3.0% (n = 5). There were no significant differences between the pathological groups. The median follow-up period (quartile 1-quartile 3) was 198 (37-373) days, with 1-year survival rates of 95.9%. At 1 year, the freedom from all aortic procedures and unplanned aortic interventions were 90.3% and 92.0%, respectively. CONCLUSIONS: The 1-year clinical outcomes of total arch replacement with FET using the E-vita Open NEO were favourable. Long-term follow-up is required to evaluate the durability of the FET.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Traumatismos de la Médula Espinal , Accidente Cerebrovascular , Humanos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Estudios de Cohortes , Aneurisma de la Aorta Torácica/cirugía , Aorta Torácica/cirugía , Disección Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
4.
J Thorac Dis ; 15(11): 5942-5951, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38090294

RESUMEN

Background: Reports on the residual descending aortic dissection (AD) after acute type A AD (TAAD) repair has been limited. Therefore, we evaluated the fate of descending aorta in patients who underwent acute TAAD repair. Methods: We reviewed 299 patients (mean: 60.4 years, 51.5% male) patients who received acute TAAD repair between 2009 and 2018, except genetic aortopathy and concomitant surgeries for the descending aorta. Subjects are categorized into classic TAAD (Classic, n=226), retrograde extension of TAAD from the intimal tear in the descending aorta (Retro, n=31), and intramural hematoma (IMH, n=42) types of AD. Interested outcome was expansion rate of descending aorta. Secondary outcome was descending aorta events including surgical repair, interventions, and aortic rupture. To reduce selection bias, baseline variables were adjusted. Multivariable risk analyses were performed to find risk factors of the study outcomes. Results: In crude analysis, descending aorta in Retro [beta, 2.260; standard error (SE), 0.559] and Classic (beta, 1.542; SE, 0.233) groups expanded faster than IMH (beta, 0.443; SE, 0.491) group. Unadjusted risk of aortic event was significantly higher in the Retro group compared with the IMH [hazard ratio (HR) =4.80; 95% confidence interval (CI): 1.56-14.7] and Classic (HR =2.36; 95% CI: 1.24-4.49) groups. Baseline adjustment did not alter these findings. In multivariable analyses, the presence of intimal tear in the upper thoracic descending aorta (above 7th thoracic vertebra) was significantly associated with the aortic expansion (beta, 2.06; SE, 0.61) and events (HR =8.74; 95% CI: 4.34-17.6). Conclusions: The descending aorta growth was faster in Retro and Classic than IMH and related with the tear location. Careful assessment on the descending is warranted.

5.
Front Cardiovasc Med ; 10: 1303816, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38155987

RESUMEN

Introduction: Recent reports have questioned the blood impermeability of the novel frozen elephant trunk (FET) device E-vita Open NEO© (EO-NEO). Therefore, standardized in vitro bleeding tests using porcine heparinized blood were performed, as well as stress testing on the blood tightness of the collar suture line, to investigate this observation. Material and methods: EO-NEO prostheses were examined in vitro for blood permeability in three test series. Initially, antegrade perfusion with heparinized porcine blood [activated clotting time (ACT) of 500 s, with a 60 min duration] was performed, followed by ante/retrograde testing via the EO-NEO side port. Testing of the collar suture line under a tension of 10 Newton (N) within a suspension device (blood pressure 120 mmHg, ACT of 560 s, 1 min duration) was carried out with the suture material force fiber white (FFWs) yarn, using standard fixation (5 stitches/cm), FFWh yarn in hemostatic fixation (15 stitches/cm), and flow weave yarn (FWYh). Results: Blood permeability testing of EO-NEO through the prosthetic lumen or via the side port demonstrated minor leakage without statistical difference between the standard and hemostatic suture lines or suture materials used, or positioning on the crimped or tapered portion (p > 0.05). The specific collar anastomosis testing demonstrated leakage volumes of 140 ml/min for FFWs vs. 16 ml/min for FFWh (p = 0.02), vs. 9 ml/min with the FWYh (p = 0.01). Conclusion: Different blood leakage tests showed minimal oozing and no difference in blood loss through the fabric and different collar suture lines, but unphysiological pressurized retrograde perfusion of the collar region showed significantly less leakage using FWYh and FFWh, prompting production modification of EO-NEO. Clinical results confirmed low blood loss using this novel FET device.

6.
Sci Rep ; 13(1): 13803, 2023 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-37612347

RESUMEN

Aortic surgery is one of the most challenging types of surgeries, which is possibly related to cognitive sequelae. We aimed to investigate the changes in resting-state functional connectivity (rsFC) associated with intraoperative circulatory arrest (CA) in aortic surgery, exploring the relationship between the altered connectivity and postoperative cognitive functions. Thirty-eight patients participated in this study (14 with CA, 24 without). Functional magnetic resonance imaging was scanned on the fifth day after surgery or after the resolution of delirium if it was developed. We assessed the differences in the development of postoperative cognitive changes and rsFC between patients with and without CA. The occurrence of postoperative delirium and postoperative cognitive dysfunction was not significantly different between the patients with and without the application of CA. However, patients with CA showed increased in posterior cingulate cortex-based connectivity with the right superior temporal gyrus, right precuneus, and right hippocampus, and medial prefrontal cortex-based connectivity with the dorsolateral prefrontal cortex. The application of moderate hypothermic CA with unilateral antegrade cerebral perfusion is unlikely to affect aspects of postoperative cognitive changes, whereas it may lead to increased rsFC of the default mode network at a subclinical level following acute brain insults.


Asunto(s)
Encéfalo , Paro Cardíaco , Humanos , Encéfalo/diagnóstico por imagen , Cognición , Perfusión , Corteza Prefrontal , Circulación Cerebrovascular
7.
J Chest Surg ; 56(4): 262-263, 2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-37248714
9.
J Chest Surg ; 56(3): 213-215, 2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37131284
10.
Int J Med Sci ; 20(5): 663-668, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37082727

RESUMEN

Background: Hypoalbuminemia is a marker of poor overall health with influences from protein energy malnutrition, systemic inflammation and hepatic and renal disease. Albumin has been reported to have a prognostic impact in various cohorts. This study investigated whether preoperative serum albumin levels could be used to predict mortality in patients with aortic aneurysms undergoing graft replacement of ascending aorta and aortic arch. Methods: We retrospectively reviewed 183 patients who underwent graft replacement of ascending aorta and aortic arch between January 2010 and December 2020. The exclusion criteria included patients with traumatic aortic injuries (n=2), previous aortic repair within 6 months (n=2), ruptured aortic aneurysms (n=14), or a lack of preoperative laboratory data or medical records (n=10). The remaining 87% eligible patients were divided into two groups based on their preoperative serum albumin levels. The lower albumin group was defined as having serum albumin levels ≤3.5 g/dL, while the higher albumin group was defined as having albumin levels >3.5 g/dL. The incidence of mortality was compared between the two groups, and a logistic regression analysis was performed to evaluate the predictors of mortality. Results: The incidence of 1-year mortality was higher in the lower albumin group than in the higher albumin group (3.4% vs. 23.5%, p=0.006). The optimal cut-off value of albumin to predict 1-year mortality was 4.0 g/dL (area under the curve 0.885, 95% CI 0.821-0.949, p<0.001), with a sensitivity and specificity of 90.0% and 80.3%, respectively. Preoperative serum albumin levels (OR = 0.116, 95% CI 0.021-0.641, p=0.014) and diabetes mellitus (OR = 5.757, 95% CI 1.018-32.565, p=0.048) remained independent predictors of mortality. Conclusion: Preoperative serum albumin levels were an independent predictor of 1-year mortality after the graft replacement of ascending aorta and aortic arch. These findings underscore that the optimization of patients' nutritional status before surgery may be warranted and should be further explored in this high-risk population.


Asunto(s)
Aneurisma de la Aorta , Implantación de Prótesis Vascular , Humanos , Aorta Torácica/cirugía , Albúmina Sérica , Pronóstico , Estudios Retrospectivos , Aneurisma de la Aorta/cirugía , Resultado del Tratamiento
11.
12.
J Thorac Dis ; 15(2): 484-493, 2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36910067

RESUMEN

Background: Aortic arch pathology often requires staged segmental repairs. Total aortic arch replacement with frozen elephant trunk (FET) offers surgical options for these pathologies. The Jotec E-vita Open NEO™ branched prosthesis was introduced in 2020; we sought to share our initial experience focusing on the prosthesis selection strategies, surgical techniques, anastomosis-bleeding and graft-oozing control methods, and early clinical outcomes from two Asian centers. Methods: We performed a retrospective cohort study in patients with aortic arch pathologies who underwent total arch replacement using the FET procedure with Jotec E-vita Open NEO™ branched prosthesis from two Asian centers between October 2020 and August 2021. The primary outcome was overall 30-day mortality, and the secondary outcomes were operative complications. Results: Twenty-five consecutive patients underwent total arch replacement with FET with the novel hybrid prosthesis. Overall 30-day mortality from both centers was 0%. Overall mean operative, cardiopulmonary bypass, hypothermic circulatory arrest, and selective antegrade cerebral perfusion times were 353.4±80.5, 183.2±39.6, 57.2±14.7, and 138.2±28.6 minutes, respectively. No patient developed stroke. Permanent spinal cord injury (SCI) was recorded in one patient (4%) and one (4%) had transient lower limb weakness that resolved after spinal drainage. There was no requirement of re-sternotomy for hemostasis. Conclusions: We reported a multicenter Asian case series with the novel FET hybrid prosthesis demonstrating the feasibility and safety of promising initial clinical outcomes. The technique of circumferential reinforcement of vascular anastomosis for hemostasis may be one of the methods for lowering the rates of re-sternotomy for hemostasis, and proper surgical or transfusion strategies would overcome the excessive oozing of the prosthesis. Long-term follow-up is required for further evaluation of aortic pathology progression and device-related outcomes.

13.
Sci Rep ; 13(1): 2502, 2023 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-36781928

RESUMEN

Optimal antiplatelet therapy after endovascular therapy (EVT) for peripheral artery disease is controversial. This trial aimed to evaluate whether sarpogrelate plus aspirin was non-inferior for preventing early restenosis after femoropopliteal (FP) EVT compared to clopidogrel plus aspirin. In this open-label, prospective randomized trial, 272 patients were enrolled after successful EVT for FP lesions. Patients in each group received aspirin 100 mg and clopidogrel 75 mg or sarpogrelate 300 mg orally once per day for 6 months. The primary outcome was target lesion restenosis at 6 months, tested for noninferiority. Patient characteristics and EVT patterns were similar, except for increased inflow procedures in the sarpogrelate group and increased outflow procedures in the clopidogrel group. The sarpogrelate group showed a tendency of less restenosis at 6 months than the clopidogrel group (13.0% vs. 19.1%, difference 6.1 percentage points, 95% CI for noninferiority - 0.047 to 0.169). Secondary endpoints related to safety outcomes were rare in both groups. Risks of target lesion restenosis of the two intervention arm were uniform across most major subgroups except for those with coronary artery disease. In conclusion, Sarpogrelate plus aspirin is non-inferior to clopidogrel plus aspirin in preventing early restenosis after FP EVT. Larger multi-ethnic trials are required to generalize these findings. Trial registration: National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT02959606; 09/11/2016).


Asunto(s)
Enfermedad Arterial Periférica , Inhibidores de Agregación Plaquetaria , Humanos , Clopidogrel/uso terapéutico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Preparaciones de Acción Retardada , Aspirina/uso terapéutico , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/tratamiento farmacológico , Resultado del Tratamiento , Quimioterapia Combinada
14.
Sci Rep ; 13(1): 1116, 2023 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-36670162

RESUMEN

Hemodynamics in aortic dissection (AD) is closely associated with the risk of aortic aneurysm, rupture, and malperfusion. Altered blood flow in patients with AD can lead to severe complications such as visceral malperfusion. In this study, we aimed to investigate the effect of cannulation flow on hemodynamics in AD using a fluid-structure interaction simulation. We developed a specific-idealized AD model that included an intimal tear in the descending thoracic aorta, a re-entry tear in the left iliac artery, and nine branches. Two different cannulation methods were tested: (1) axillary cannulation (AC) only through the brachiocephalic trunk and (2) combined axillary and femoral cannulation (AFC) through the brachiocephalic trunk and the right common iliac artery. AC was found to result in the development of a pressure difference between the true lumen and false lumen, owing to the difference in the flow rate through each lumen. This pressure difference collapsed the true lumen, disturbing blood flow to the celiac and superior mesenteric arteries. However, in AFC, the pressure levels between the two lumens were similar, and no collapse occurred. Moreover, the visceral flow was higher than that in AC. Lastly, the stiffness of the intimal flap affected the true lumen's collapse.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Disección Aórtica , Humanos , Aneurisma de la Aorta/cirugía , Cateterismo , Aorta Abdominal , Perfusión , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento
15.
Asian Cardiovasc Thorac Ann ; 31(1): 48-50, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35678833

RESUMEN

Total arch replacement for aortic dissection is traditionally associated with high mortality and morbidity rates. Here, we share our strategies for improving surgical outcomes such as Y incision, unilateral antegrade cerebral perfusion, Teflon felt neo-media formation, and reinforcement of the anastomosis site.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Humanos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aorta Torácica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Perfusión , Resultado del Tratamiento
16.
J Thorac Cardiovasc Surg ; 166(5): 1400-1410, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-35221028

RESUMEN

OBJECTIVES: Intramural hematoma may be generated by a minimal intimal tear. Most surgeries for acute type A intramural hematoma are performed on the proximal aorta alone regardless of the intimal tear site. Under the assumption that major adverse aortic events (MAAEs) would be related to the location of primary intimal tear, we reviewed preoperative computed tomography scan findings. METHODS: Sixty patients with acute type A intramural hematoma who underwent surgery from January 2008 to December 2019 were retrospectively analyzed. The maximal diameter, maximal thickness of the intramural hematoma, and hematoma thickness ratio of the ascending and descending aortae were measured. MAAEs were defined as newly developed aortic dissection, rupture, newly developed penetrating aortic ulcer (PAU), enlargement of the PAU, and aortic death. RESULTS: The number of patients with PAU in the descending aorta (dPAU) was significantly higher in the MAAE (+) group. The MAAE (+) group showed lower measurements of the ascending aorta and higher measurements of the descending aorta than the MAAE (-) group. In the univariate analysis, dPAU, hematoma thickness ratio of the ascending and descending aortae, and descending aorta hematoma thickness >8.58 mm were risk factors of MAAE. Intimal tear noted intraoperatively and ascending aorta hematoma thickness >10.25 mm were protective factors of MAAE. CONCLUSIONS: Aortopathies (ie, PAU, ulcer-like projections, and the hematoma thickness ratio) are important clues to determine the location of intimal tear. Occurrence of MAAEs seems to be highly related to the pathology of the descending aorta. The modalities of treatment for stable acute type A intramural hematoma that do not meet the existing guidelines should be tailored to the location of the intimal tear.


Asunto(s)
Enfermedades de la Aorta , Disección Aórtica , Humanos , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/patología , Estudios Retrospectivos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/patología , Hematoma/diagnóstico por imagen , Hematoma/cirugía , Hematoma/etiología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aorta Torácica/patología
17.
Vascular ; 31(3): 447-454, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35100906

RESUMEN

OBJECTIVES: The aim of this study is to summarize a single-center experience of hybrid debranching endovascular repair of the aortic arch and proximal descending thoracic aorta (DTA) with regard to the mid-term outcomes with highlighting the difference between the landing zones 0-2. METHODS: A retrospective review of data from a prospectively collected registry (Gangnam Severance Endovascular Aortic Registry) was performed. From among 332 patients whose aortic pathology was managed with TEVAR, 112 patients who underwent hybrid arch repair during the study period between 2012 and 2016 were identified. The patients were grouped into three cohorts according to the proximal landing zones (0, 1, and 2) of Ishimaru. The early outcome (30-days) in terms of mortality, morbidity, supra-aortic vessels patency, and presence of endoleak were analyzed. The survival, freedom from re-intervention, and major complications during follow-up were demonstrated. RESULTS: During the study period. 112 patients (mean age 65±7, 79% males) were included. The patients were distributed in three cohorts: 8 (7%) patients with proximal landing zone 0, 20 (18%) with zone 1, and 80 (75%) with zone 2 hybrid aortic arch repair. Technical success was achieved in 7 (88%), 19 (90%), and 79 (94%) patients for zones 0, 1, and 2, respectively. The mean intensive care unit (ICU) stay was shorter in zone 2 (p = .005). The mean total hospital stay was shorter in zone 2 (p = .03). The overall in-hospital mortality rate was 5% (4/112). There was no spinal cord ischemia or early surgical conversion. Renal function deterioration was seen more but not significantly in zone 0 patients (p = .08). Respiratory failure was seen significantly in zone 0 patients (p = .01). Stroke occurred in 6/44 (14%) patients with degenerative aneurysm versus 1/60 (2%) patients with aortic dissection (p =.06). Early CTA showed 100% patency of the supra-aortic vessels. The early endoleak rate was significant in zone 0 patients (p = .008). The mean follow-up period was (32±19 months). The survival rates and freedom from re-intervention were not statistically significant among the three zones. However, the survival rate and freedom from intervention tend to be higher in zone 2 versus zone 0 (p = .07 and .09), respectively. CONCLUSION: Hybrid debranching endovascular aortic arch repair is feasible and relatively safe with acceptable mid-term outcomes. Zone 0 patients has worse early and late outcomes in comparison to other zones. Careful patient selection and improved endovascular technology may be the key to improve the outcomes.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Endofuga/etiología , Endofuga/cirugía , Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...