Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
2.
Ann Vasc Surg ; 78: 190-196, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34464729

RESUMEN

BACKGROUND: A total percutaneous approach for management of aortic pathologies with endovascular grafts requires the use of large size delivery-systems. The diameter of these delivery systems usually exceeds the recommended sizes for most of the currently available percutaneous closure devices. A safe, effective and simple vascular access site closure device is desirable for success for percutaneous procedures for aortic pathologies. Hence, we aim to study safety and effectiveness of the use of a single suture based vascular access closure device (ProGlide) using a technique involving serial up and downsizing of the sheath size to achieve access site hemostasis in patients undergoing endovascular graft placement using femoral artery approach. MATERIALS AND METHODS: We studied all consecutive patients who underwent endovascular grafting from January 2018 to December 2019. It is a retrospective observational study comparing procedural and short-term outcomes between single ProGlide use and surgical cut-down for femoral access site closure. We excluded patients with femoral artery minimal luminal diameter less than 5 mm, the presence of an aneurysm of the femoral artery, ≥180 degrees of calcium present at femoral/ external iliac artery and history of any vascular closure device use in the last six months. RESULTS: We included 30 patients in single ProGlide group and 30 patients in the surgical cut-down group. One-third of the procedures were urgent procedures in the single Proglide group. Single ProGlide was successful in 93.34% patients and failure (6.66%) was seen due to hematoma and pseudoaneurysm in one patient each detected before discharge. The primary end-point defined by the success of procedure did not differ between the two groups. There were higher complications in the surgical group till 30 days as evidenced by infection, hematoma and neuronal injury. The secondary end-point, defined by the composite of complication events after discharge till 30 days was significantly higher in the surgical group (P-0.005) CONCLUSION: In patients with suitable femoral artery anatomy who undergo endovascular graft placement, effective hemostasis can be achieved safely using up and downsizing of the sheath with a single suture-based technique (Proglide). The results of the study could be considered hypothesis generating and needs to be confirmed in a randomized controlled trial before being adopted in clinical practice.


Asunto(s)
Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Periférico/instrumentación , Procedimientos Endovasculares/instrumentación , Hemorragia/prevención & control , Técnicas Hemostáticas/instrumentación , Dispositivos de Acceso Vascular , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Periférico/efectos adversos , Procedimientos Endovasculares/efectos adversos , Diseño de Equipo , Femenino , Arteria Femoral , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Punciones , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
3.
J Am Heart Assoc ; 10(17): e021207, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-34465133

RESUMEN

Background Estimation of the balance between subendocardial oxygen supply and demand could be a useful parameter to assess the risk of myocardial ischemia. Evaluation of the subendocardial viability ratio (SEVR, also known as Buckberg index) by invasive recording of left ventricular and aortic pressure curves represents a valid method to estimate the degree of myocardial perfusion relative to left ventricular workload. However, routine clinical use of this parameter requires its noninvasive estimation and the demonstration of its reliability. Methods and Results Arterial applanation tonometry allows a noninvasive estimation of SEVR as the ratio of the areas directly beneath the central aortic pressure curves obtained during diastole (myocardial oxygen supply) and during systole (myocardial oxygen demand). However, this "traditional" method does not account for the intra-ventricular diastolic pressure and proper allocation to systole and diastole of left ventricular isometric contraction and relaxation, respectively, resulting in an overestimation of the SEVR values. These issues are considered in the novel method for SEVR assessment tested in this study. SEVR values estimated with carotid tonometry by "traditional" and "new" method were compared with those evaluated invasively by cardiac catheterization. The "traditional" method provided significantly higher SEVR values than the reference invasive SEVR: average of differences±SD= 44±11% (limits of agreement: 23% - 65%). The noninvasive "new" method showed a much better agreement with the invasive determination of SEVR: average of differences±SD= 0±8% (limits of agreement: -15% to 16%). Conclusions Carotid applanation tonometry provides valid noninvasive SEVR values only when all the main factors determining myocardial supply and demand flow are considered.


Asunto(s)
Presión Sanguínea , Oxígeno , Diástole , Humanos , Imagen de Perfusión Miocárdica , Oxígeno/sangre , Reproducibilidad de los Resultados , Sístole , Función Ventricular Izquierda
4.
Blood Press ; 29(6): 375-381, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32608283

RESUMEN

PURPOSE: Cuffless blood pressure (CL-BP) measurements are believed to be a potentially alternative to cuff-occlusion-based (C-BP) measurement. A new cuffless device was developed for ambulatory BP monitoring. We assessed the accuracy of a new CL-BP device compared to a standard oscillatory C-BP device over the 24 h. MATERIALS AND METHODS: Eighty-four consecutive patients were included in the study. BP was measured simultaneously by the CL-BP device and by a C-BP device over the 24 h. Calculations included 24 h mean systolic (S) BP, the mean diastolic (D) BP and the heart rate (HR). Correlations between the CL-BP and C-BP measurements were sought using Pearson's correlation coefficients and Bland-Altman plots. RESULTS: Using the C-BP device, the 24 h SBP value for the cohort was 125.4 ± 10.9 mmHg (mean ± SD); the corresponding DBP value being 75 ± 8.3 mmHg. Mean SBP/DBP were higher with the CL-BP device, i.e. 131.1 ± 15.9/80.2 ± 9.7 mmHg . The correlation coefficients between the two sets of values were significant (SBP: r = 0.58, DBP: r = 0.65). Better correlations for SBP and DBP were found 1) in patients with BMI > 25 (SBP: r = 0.65, DBP: r = 0.70) compared to those with BMI <25 and 2) in males compared to females (SBP: r = 0.71, DBP: r = 0.77). CONCLUSIONS: In our patients a CL-BP device estimated 24 h mean SBP and DBP differently from the classical oscillometric device, with a moderate correlation. CL-BP measurements were most accurate on male and overweight subjects.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Presión Sanguínea , Anciano , Diástole , Diseño de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Sístole
5.
J Hypertens ; 38(5): 936-942, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31990900

RESUMEN

INTRODUCTION: Recent randomized controlled trials have confirmed the ability of renal denervation to lower blood pressure (BP) in patients, resistant to the BP-lowering effect of multiple antihypertensive drug administration. Evidence is limited, however, in patients with end-stage renal disease (ESRD) and haemodialysis, a condition in which a persistent BP elevation, despite administration of many antihypertensive drugs, is common. Aim of the present study was to test the BP-lowering efficacy of renal denervation in patients with resistant hypertension and ESRD on haemodialysis. BP was measured repeatedly in the office and over the 24 h during 1-year follow-up. METHODS AND RESULTS: The study was conducted from February 2017 to January 2018 at the Policlinico of Monza, Monza, Italy. We included 24 men and women aged at least 20 years (mean 55 ±â€Š16) who had ESRD, were on long-term haemodialysis and exhibited resistant hypertension, that is, elevated office and ambulatory BP values, despite multidrug antihypertensive treatment (n = 5.4 ±â€Š1). We excluded patients with renal artery stenosis, malignancy, and a probable life expectancy less than 1 year. Twelve patients were included in the renal denervation and 12 in the medical treatment (control) group. All patients underwent office and 24 h ambulatory BP measurements at baseline and at 1, 6 and 12 months during the follow-up. In the renal denervation group, baseline office and 24 h mean SBP were 180 ±â€Š112 and 175 ±â€Š11 mmHg, respectively, the corresponding values in the control group being 181 ±â€Š19 and 181 ±â€Š20 mmHg. Most of the other baseline characteristics were also similar or only slightly different between groups, including the mean number of administered antihypertensive drugs at baseline. SBP showed an early and persistent reduction after renal denervation (office SBP: 165 ±â€Š13; 150 ±â€Š7 and 149 ±â€Š11mmHg; 24 h SBP 163 ±â€Š20, 148 ±â€Š10 and 149 ±â€Š17 mmHg after 1, 6 and 12 months, respectively). The BP-lowering effect was almost always present and statistically significant during both the day and night. DBP changes followed a similar pattern whereas heart rate never showed any significant change. No significant periprocedural complication of renal denervation was seen. The mean number of administered drugs did not show any significant BP change during the study. CONCLUSION: In ESRD patients under long-term haemodialysis in whom BP was markedly elevated despite administration of many antihypertensive drugs, renal denervation lowered both ambulatory and office BP. The reduction persisted over a 1-year follow-up.


Asunto(s)
Presión Sanguínea/fisiología , Desnervación/métodos , Hipertensión/cirugía , Fallo Renal Crónico/cirugía , Riñón/inervación , Diálisis Renal , Adulto , Anciano , Antihipertensivos/uso terapéutico , Monitoreo Ambulatorio de la Presión Arterial , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Hipertensión/tratamiento farmacológico , Hipertensión/fisiopatología , Italia , Riñón/fisiopatología , Fallo Renal Crónico/fisiopatología , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
Hypertension ; 74(1): 117-129, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31132954

RESUMEN

Aortic pulse wave velocity is a worldwide accepted index to evaluate aortic stiffness and can be assessed noninvasively by several methods. This study sought to determine if commonly used noninvasive devices can all accurately estimate aortic pulse wave velocity. Pulse wave velocity was estimated in 102 patients (aged 65±13 years) undergoing diagnostic coronary angiography with 7 noninvasive devices and compared with invasive aortic pulse wave velocity. Devices evaluating carotid-femoral pulse wave velocity (Complior Analyse, PulsePen ET, PulsePen ETT, and SphygmoCor) showed a strong agreement between each other ( r>0.83) and with invasive aortic pulse wave velocity. The mean difference ±SD with the invasive pulse wave velocity was -0.73±2.83 m/s ( r=0.64) for Complior-Analyse: 0.20±2.54 m/s ( r=0.71) for PulsePen-ETT: -0.04±2.33 m/s ( r=0.78) for PulsePen ET; and -0.61±2.57 m/s ( r=0.70) for SphygmoCor. The finger-toe pulse wave velocity, evaluated by pOpmètre, showed only a weak relationship with invasive aortic recording (mean difference ±SD =-0.44±4.44 m/s; r=0.41), and with noninvasive carotid-femoral pulse wave velocity measurements ( r<0.33). Pulse wave velocity estimated through a proprietary algorithm by BPLab (v.5.03 and v.6.02) and Mobil-O-Graph showed a weaker agreement with invasive pulse wave velocity compared with carotid-femoral pulse wave velocity (mean difference ±SD =-0.71±3.55 m/s, r=0.23; 1.04±2.27 m/s, r=0.77; and -1.01±2.54 m/s, r=0.71, respectively), revealing a negative proportional bias at Bland-Altman plot. Aortic pulse wave velocity values provided by BPLab and Mobil-O-Graph were entirely dependent on age-squared and peripheral systolic blood pressure (cumulative r2=0.98 and 0.99, respectively). Thus, among the methods evaluated, only those assessing carotid-femoral pulse wave velocity (Complior Analyse, PulsePen ETT, PulsePen ET, and SphygmoCor) appear to be reliable approaches for estimation of aortic stiffness.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Hemodinámica/fisiología , Análisis de la Onda del Pulso/métodos , Rigidez Vascular/fisiología , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Determinación de la Presión Sanguínea/métodos , Enfermedades Cardiovasculares/fisiopatología , Estudios de Cohortes , Estenosis Coronaria/fisiopatología , Humanos , Italia , Modelos Lineales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Flujo Pulsátil/fisiología , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
7.
EuroIntervention ; 14(12): e1278-e1285, 2018 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-30327287

RESUMEN

AIMS: The success of transfemoral transcatheter aortic valve implantation (TAVI) and thoraco-abdominal aneurysm repair (TAAR) depends on haemostatic control of the access site, which is usually obtained with suture-based closure devices (Prostar or two ProGlide). A single ProGlide/Glubran technique, involving a suture placement on the vessel wall followed by tissue glue injection around the vessel wall, has not been previously investigated in this clinical setting. Our aim was to study the feasibility and safety of a single ProGlide/Glubran technique for vascular access-site closure after transfemoral TAVI and TAAR. METHODS AND RESULTS: This technique was used in 250 patients from 2012 to 2017. The primary endpoint was the success of the technique, defined as access-site haemostasis without complications and not requiring any additional intervention within 30 days of the index procedure. Patients had a mean age of 82.4±1.93 years, with a logistic EuroSCORE of 20.2±2.32. A total of 218 TAVI and 32 TAAR procedures were performed with a mean sheath size of 18.09±1.55 Fr. The mean sheath to femoral artery ratio was 1.04±0.16, with mean femoral artery minimal lumen diameter 6.65±0.64 mm. The overall success rate of this technique was 98.4%. Four patients (1.6%) developed critical stenosis of the femoral artery requiring balloon dilatation. No major VARC-2 vascular complications were observed. Thirty-day mortality was 0.4% (non-cardiovascular). CONCLUSIONS: The results of this study suggest that the single ProGlide/Glubran technique is a safe and effective method of closing the arterial access site after transfemoral TAVI and TAAR. The results of our study need to be confirmed in a randomised controlled trial before being adopted in routine clinical practice.


Asunto(s)
Aneurisma de la Aorta Abdominal , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/cirugía , Válvula Aórtica , Arteria Femoral , Humanos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 91(5): 884-891, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28707375

RESUMEN

BACKGROUND: Patients with diabetes mellitus (DM) remain at higher risk of restenosis after percutaneous coronary intervention despite the use of contemporary drug-eluting stents. The Cre8 amphilimus-eluting stent (AES) has shown promising results in DM patients. Whether this holds true irrespective of patient's clinical and angiographic complexity is unknown. METHODS: Five hundred and ninety five consecutive patients (738 lesions) undergoing AES implantation were included in the INVESTIG8 multicenter registry. Patients were stratified according to DM status and further stratified according to patients' complexity. The prespecified primary endpoint was target lesion failure (TLF)-defined as the composite of cardiac death, target-vessel myocardial infarction, and target lesion revascularization (TLR). RESULTS: DM patients were more often complex as compared to non-DM patients (70% vs. 61%, P = 0.015). At 18-month follow-up, there was a trend to a higher TLF rate in DM than in non-DM patients (6.9% vs. 3.5%, P = 0.063). This was largely driven by a markedly higher risk of TLF among complex DM patients as compared to simple DM patients (8.9% vs. 2.4%, P = 0.053). A multivariate analysis identified complexity (HR 6.11, 95% CI: 1.42-26.2) but not DM (HR 1.59; 95% CI 0.71-3.56) as an independent predictor of TLF. Of note, TLR rates were similar between DM and non-DM patients (3.3% vs. 1.9%, P = 0.228). CONCLUSIONS: In this real-world, multicenter registry the Cre8 AES showed favorable clinical outcomes in DM patients. Increased risk of TLF appears to be driven by patients' complexity rather than DM status. These findings will need to be confirmed in a large-scale randomized trial.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/etiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Recurrencia , Sistema de Registros , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
9.
Am J Hypertens ; 31(1): 80-88, 2017 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-29059329

RESUMEN

BACKGROUND: Aortic pulse wave velocity (PWV) is an indirect index of arterial stiffness and an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus an essential feature for its clinical application. However, studies providing a comparative estimate of the reproducibility of PWV across different noninvasive devices are lacking, especially in the elderly and in individuals at high cardiovascular risk. METHODS: Aimed at filling this gap, short-term repeatability of PWV, estimated with 6 different devices (Complior Analyse, PulsePen-ETT, PulsePen-ET, SphygmoCor Px/Vx, BPLab, and Mobil-O-Graph), was evaluated in 102 high cardiovascular risk patients hospitalized for suspected coronary artery disease (72 males, 65 ± 13 years). PWV was measured in a single session twice, at 15-minute interval, and its reproducibility was assessed though coefficient of variation (CV), coefficient of repeatability, and intraclass correlation coefficient. RESULTS: The CV of PWV, measured with any of these devices, was <10%. Repeatability was higher with cuff-based methods (BPLab: CV = 5.5% and Mobil-O-Graph: CV = 3.4%) than with devices measuring carotid-femoral PWV (Complior: CV = 8.2%; PulsePen-TT: CV = 8.0%; PulsePen-ETT: CV = 5.8%; and SphygmoCor: CV = 9.5%). In the latter group, PWV repeatability was lower in subjects with higher carotid-femoral PWV. The differences in PWV between repeated measurements, except for the Mobil-O-Graph, did not depend on short-term variations of mean blood pressure or heart rate. CONCLUSIONS: Our study shows that the short-term repeatability of PWV measures is good but not homogenous across different devices and at different PWV values. These findings, obtained in patients at high cardiovascular risk, may be relevant when evaluating the prognostic importance of PWV.


Asunto(s)
Aorta/fisiología , Análisis de la Onda del Pulso/instrumentación , Análisis de la Onda del Pulso/estadística & datos numéricos , Rigidez Vascular/fisiología , Anciano , Anciano de 80 o más Años , Algoritmos , Presión Sanguínea , Determinación de la Presión Sanguínea , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/fisiopatología , Arterias Carótidas/fisiopatología , Femenino , Arteria Femoral/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Riesgo
10.
J Interv Cardiol ; 29(4): 406-13, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27338839

RESUMEN

INTRODUCTION: Percutaneous patent foramen ovale (PFO) closure by means of a septal occluder device (SOD) is a well-known therapeutic strategy for the secondary prevention of paradoxical embolic neurological events. The aim of this study was to provide long-term echocardiographic and clinical follow-up data on patients who had undergone percutaneous PFO closure with 2 different SOD. METHODS: We selected 2 groups of patients treated with 2 different SOD: Group A: 52 patients with an Amplatzer(®) PFO Occluder and Group B: 49 patients with a Figulla Flex(®) device. All patients underwent follow-up Bubble Test Transthoracic Echocardiography (BTTE) and clinical examination. The results were compared with those recently reported in a group of patients with similar characteristics, but that had been treated conservatively, which acted as a control group. RESULTS: The mean follow-up after PFO closure was 53 months. The Amplatzer(®) PFO Occluder and the Figulla Flex were used in 52 (51.5%) and 49 (48.5%) of patients, respectively. We found no significant difference in the rate of effective PFO closure between the devices: Amplatzer 91.4%, Figulla 93.9% (P = 0.71). One patient (1.0%) suffered a recurrent neurologic event. BTTE was positive (BTTE+) in 8 patients (8%), 5 with an Amplatzer, and 3 with a Figulla device (P = 0.516). Only 1 patient with BTTE+ had a recurrent TIA (12.5%). No significant relationship was found between device dimensions and BTTE+ (P = 0.062). In the control group (163 patients), the recurrence of neurologic events was 9.2% (15 events), that was significantly higher in respect to the patients who had undergone percutaneous closure of the PFO. CONCLUSIONS: Percutaneous PFO closure was associated with a remarkably low risk of recurrent embolic neurological events, and no long-term device-related major complications. No statistically significant difference emerged between the 2 different SODs regarding BTTE positivity. Long-term follow-up showed that the recurrence of neurological events has been significantly higher in the group treated in a conservative way.


Asunto(s)
Foramen Oval Permeable , Efectos Adversos a Largo Plazo , Complicaciones Posoperatorias , Implantación de Prótesis , Dispositivo Oclusor Septal , Adulto , Anciano , Cateterismo Cardíaco/métodos , Ecocardiografía/métodos , Ecocardiografía/estadística & datos numéricos , Diseño de Equipo , Femenino , Estudios de Seguimiento , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/cirugía , Humanos , Italia , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/epidemiología , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud/estadística & datos numéricos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Implantación de Prótesis/estadística & datos numéricos , Dispositivo Oclusor Septal/efectos adversos , Dispositivo Oclusor Septal/clasificación , Resultado del Tratamiento
11.
Cardiovasc Revasc Med ; 16(3): 141-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25708003

RESUMEN

AIM: An innovative xenon-chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. METHODS AND RESULTS: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. CONCLUSIONS: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications.


Asunto(s)
Angioplastia de Balón Asistida por Láser , Aterectomía Coronaria , Angiografía Coronaria , Stents , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/métodos , Angioplastia de Balón Asistida por Láser/métodos , Aterectomía Coronaria/métodos , Angiografía Coronaria/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/métodos , Factores de Tiempo , Resultado del Tratamiento
12.
Int J Cardiol ; 174(3): 624-7, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24809922

RESUMEN

BACKGROUND: Common clinical practice recommends dual antiplatelet therapy (DAPT) for transcatheter aortic valve implantation (TAVI). The aim of the study was to evaluate, in a double blind randomized study, the safety of TAVI, with adjunctive pharmacotherapy consisting of single antiplatelet therapy. METHODS AND RESULTS: From April 2010 to April 2011, 120 consecutive patients, undergoing TAVI, have been enrolled in the study. Patients were randomly assigned to DAPT group (aspirin and clopidogrel 75 mg/qd or ticlopidine 500 mg/bid) or ASA group (aspirin only). TAVI device was the Sapien XT-Novaflex Delivery System (Edwards Lifesciences, Inc.). All patients were followed up to 6 months. Device success was achieved in 100% of patients. No difference in the VARC combined 30 day safety endpoint, all cause and cardiovascular mortality was observed. At 30 days vascular complications were reduced in the ASA group (p<0.05). No differences in the clinical status were detected between the groups up to 6 months. CONCLUSIONS: This study suggests that TAVI procedures can be performed without DAPT without increasing the morbidity and mortality. These findings, if confirmed in a larger multicenter randomized trial, will no longer support the use of DAPT for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/mortalidad , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Masculino , Proyectos Piloto , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
13.
EuroIntervention ; 10(1): 169-72, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24602835

RESUMEN

BACKGROUND: An 84-year-old man suffering from dyspnoea on mild exertion and a 10-year history of mitral valve replacement with a mechanical prosthesis presented to our department. The patient had an isolated right aortic arch. INVESTIGATION: Transthoracic echocardiography demonstrated severe LV systolic dysfunction (EF 25%), good function of the previously implanted mechanical prosthesis and severe aortic stenosis. Multislice computed tomography confirmed the presence of an isolated right aortic arch with mirror-image branching. DIAGNOSIS: Severe symptomatic aortic stenosis in a patient with right aortic arch at high risk for surgical reintervention. MANAGEMENT: Transcatheter aortic valve implantation using conventional delivery system.


Asunto(s)
Aorta Torácica/anomalías , Estenosis de la Válvula Aórtica/cirugía , Cardiopatías Congénitas/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Angiografía , Estenosis de la Válvula Aórtica/complicaciones , Humanos , Masculino , Tomografía Computarizada por Rayos X
15.
J Am Coll Cardiol ; 60(18): 1739-42, 2012 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-23040582

RESUMEN

OBJECTIVES: The purpose of this prospective registry was to evaluate the safety and efficacy, at 1 year, of the use of drug-eluting balloons (DEB) for the treatment of superficial femoral artery (SFA) in-stent restenosis (ISR). BACKGROUND: The use of the self-expanding nitinol stent has improved the patency rate of SFA after percutaneous transluminal angioplasty (PTA). As the population with SFA stenting continues to increase, occurrence of ISR has become a serious problem. The use of DEB has showed promising results in reducing restenosis recurrence in coronary stents. METHODS: From December 2009 to December 2010, 39 consecutive patients underwent PTA of SFA-ISR in our institution. All patients underwent conventional SFA PTA and final post-dilation with paclitaxel-eluting balloons (IN.PACT, Medtronic, Minneapolis, Minnesota). Patients were evaluated up to 12 months. RESULTS: Technical and procedural success was achieved in every patient. No in-hospital major adverse cardiac and cerebrovascular events occurred. At 1 year, 1 patient died due to heart failure. Primary endpoint, primary patency rate at 12 months, was obtained in 92.1% (35 patients). At 1 year, patients were asymptomatic for claudication, and duplex assessment demonstrated lack of recurrent restenosis (100% rate of Secondary patency). The presence of an occlusive restenosis at the time of treatment was not associated with an increased restenosis rate, when compared with non-occlusive restenosis, at 1 year. CONCLUSIONS: The data suggest that adjunctive use of DEB for the treatment of SFA-ISR represents a potentially safe and effective therapeutic strategy. These data should be considered hypothesis-generating to design a randomized trial.


Asunto(s)
Reestenosis Coronaria , Stents Liberadores de Fármacos , Arteria Femoral/patología , Anciano , Aleaciones/administración & dosificación , Angioplastia/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Stents , Resultado del Tratamiento , Enfermedades Vasculares/terapia , Grado de Desobstrucción Vascular
16.
G Ital Cardiol (Rome) ; 13(11): 772-6, 2012 Nov.
Artículo en Italiano | MEDLINE | ID: mdl-23096589

RESUMEN

At present, transcatheter aortic valve implantation (TAVI) is a proven treatment option for patients with symptomatic degenerative aortic stenosis at high risk for conventional surgery. In countries where TAVI is currently performed, the number of procedures and centers involved has been continuously increasing. The present document from the Italian Society of Interventional Cardiology (SICI-GISE) aims to improve the available evidence and current consensus on this topic through the definition of training needs and knowledge base for both operators and centers.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco , Cardiología , Implantación de Prótesis de Válvulas Cardíacas , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Cardiología/normas , Equipos y Suministros/normas , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/normas , Arquitectura y Construcción de Hospitales/normas , Humanos , Italia , Medición de Riesgo , Índice de Severidad de la Enfermedad , Sociedades Médicas , Ultrasonografía
17.
Cardiovasc Revasc Med ; 13(4): 219-23, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22632996

RESUMEN

BACKGROUND: The use of directional atherectomy (DA) for the treatment of calcified femoro-popliteal lesions seems to improve the acute procedural success, however without reducing the long term restenosis rate. Drug coated balloons (DCB) reduced restenosis rate in non heavy calcified lesions. Aim of this study was to demonstrate safety and efficacy of a combined endovascular approach using DA and DCB for the treatment of heavy calcified lesions of the femoro-popliteal tract. METHODS: From January 2010 to November 2010, 240 patients underwent PTA of the femoro-popliteal tract in our institution. Within this cohort a total of 30 patients had life limiting claudication (LLC) (n=18) and 12 a critical limb ischemia (CLI) with baseline Rutherford class 4.2±1.2 underwent PTA of heavy calcified lesions with intravascular ultrasound guided DA and DCB. All procedures have been performed using a distal protection device. Stent implantation was allowed only in case of flow limiting dissections or suboptimal result (residual stenosis>50%) by visual estimation. After the intervention patients were followed up to 12 months. RESULTS: Procedural and clinical success, was achieved in all cases. Bail-out stenting was necessary in only two (6.5%). At twelve month follow up median Rutherford class was 2.2±1.2, ABI was 0.8±0.1 and Limb salvage rate was 100%. Two minor, foot finger or forefoot amputations, were performed to reach complete wound healing and/or preserve deambulation. Duplex control was performed in all the cases (n=30). In three cases duplex scan showed a significant target lesion restenosis requiring a reintervention (TLR=10%) leading a total one-year secondary patency rate of 100%. All the three restenosed patients were insulin dependent diabetics and none of them were stented during the procedure. CONCLUSION: The data suggest that combined use of DA and DCB may represent a potential alternative strategy for the treatment of femoro-popliteal severely calcified lesions. These very promising data and the considered hypothesis have to be confirmed in a multicentre randomised trial.


Asunto(s)
Angioplastia de Balón , Aterectomía , Fármacos Cardiovasculares/administración & dosificación , Catéteres , Materiales Biocompatibles Revestidos , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Calcificación Vascular/terapia , Anciano , Amputación Quirúrgica , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/instrumentación , Angioplastia de Balón/métodos , Aterectomía/efectos adversos , Aterectomía/instrumentación , Aterectomía/métodos , Constricción Patológica , Enfermedad Crítica , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Claudicación Intermitente/etiología , Claudicación Intermitente/terapia , Isquemia/etiología , Isquemia/terapia , Italia , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/complicaciones , Enfermedad Arterial Periférica/diagnóstico , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Radiografía , Recurrencia , Sistema de Registros , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Ultrasonografía Intervencional , Calcificación Vascular/complicaciones , Calcificación Vascular/diagnóstico , Calcificación Vascular/fisiopatología , Grado de Desobstrucción Vascular
18.
J Clin Endocrinol Metab ; 97(8): 2862-71, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22639289

RESUMEN

OBJECTIVE: We examined the effects of peri-procedural intensive glycemic control (IGC) during early percutaneous coronary intervention (PCI) on restenosis rate in hyperglycemic patients with ST-segment elevation myocardial infarction (STEMI). RESEARCH DESIGN AND METHODS: A total of 165 hyperglycemic patients (glucose ≥ 140 mg/dl) with first STEMI undergoing PCI were studied. Patients were randomized to IGC for almost 24 h after PCI (n = 82; glucose, 80-140 mg/dl) followed by multidose sc insulin during the hospital stay or conventional glycemic control (CGC; n = 83; glucose, 180-200 mg/dl) followed by conventional therapy. Coronary angiography was performed at study entry and at 6-month follow-up. Blood samples for glycemia, hemoglobin A1c, inflammatory markers (C-reactive protein and TNF-α), monocyte chemoattractant-protein-1, and oxidative stress (nitrotyrosine) were collected immediately before and 24 h, 30 and 180 d after PCI. RESULTS: After insulin infusion, mean plasma glucose during the peri-procedural period was greater in the CGC group than in the IGC group (CGC, 191 ± 15 mg/dl; IGC, 145 ± 35 mg/dl; P < 0.001). After the insulin infusion period, the levels of markers of oxidative stress (nitrotyrosine), inflammation (C-reactive protein, TNF-α), and monocyte chemoattractant-protein-1 were significantly higher in CGC patients compared with IGC patients. Moreover, ICG during PCI reduces restenosis by half (48 and 24%) at 6 months. During follow-up, there was no difference in mortality rates, glucose, inflammatory and oxidative stress markers among the groups. In-stent restenosis was positively associated with mean plasma glucose levels as well as oxidative stress and inflammatory markers during the insulin infusion period. CONCLUSIONS: In hyperglycemic patients with STEMI, optimal peri-procedural glycemic control by reducing oxidative stress and inflammation may improve the outcome after PCI.


Asunto(s)
Angioplastia Coronaria con Balón , Glucemia/análisis , Reestenosis Coronaria/prevención & control , Electrocardiografía , Infarto del Miocardio/fisiopatología , Stents/efectos adversos , Angiografía Coronaria , Reestenosis Coronaria/epidemiología , Hemoglobina Glucada/análisis , Humanos , Infarto del Miocardio/sangre , Estudios Prospectivos
19.
J Vasc Surg ; 52(6): 1505-10, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20719465

RESUMEN

BACKGROUND: General recommendations indicate that, during a carotid artery stenting (CAS), sufficient unfractionated heparin (UFH) has to be given to maintain the activated clotting time between 250 to 300 seconds. Bivalirudin use is able to reduce postprocedural bleedings in percutaneous interventions when compared with UFH. The study purpose was to evaluate, in a randomized study, the safety and efficacy of bivalirudin versus heparin during CAS, using proximal endovascular occlusion (PEO) as a distal protection device. METHODS: From January 2006 to December 2009, 220 patients undergoing CAS using PEO have been randomly assigned to one of the study arms (control arm: 100 UI/kg UFH or bivalirudin arm: 0.75 mg/kg intravenous bolus and intraprocedural infusion at 1.75 mg/kg/h). RESULTS: Procedural success was achieved in all the patients. No episodes of intraprocedural thrombosis occurred. One major stroke occurred in the bivalirudin arm, and two minor strokes occurred, one in each group. A significant difference in the incidence of postprocedural bleedings was observed between the study groups; bivalirudin use was associated with reduced number of bleedings according to Thrombolysis In Myocardial Infarction criteria. CONCLUSIONS: The use of bivalirudin should be considered a safe and effective anticoagulation regimen during CAS, using PEO as a distal protection device. Bivalirudin use is associated with a reduced incidence of bleedings.


Asunto(s)
Anticoagulantes/uso terapéutico , Oclusión con Balón , Arteria Carótida Interna , Estenosis Carotídea/cirugía , Procedimientos Endovasculares , Heparina/uso terapéutico , Fragmentos de Péptidos/uso terapéutico , Stents , Accidente Cerebrovascular/prevención & control , Anciano , Pérdida de Sangre Quirúrgica/prevención & control , Femenino , Hirudinas , Humanos , Masculino , Proteínas Recombinantes/uso terapéutico , Trombosis/prevención & control , Tiempo de Coagulación de la Sangre Total
20.
Catheter Cardiovasc Interv ; 76(1): 9-15, 2010 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-20578188

RESUMEN

BACKGROUND: Carotid stenting (CAS) has been proposed as an alternative to carotid endoarterectomy also in elderly patients with discrepant results. However, the use of proximal neuroprotection devices have not been evaluated in octogenarians. PURPOSE: The aim of this multicenter prospective registry was to demonstrate that CAS in octogenarians is safe and effective if performed in high-volume centers by experienced operators. METHODS: From July 2005 to May 2009, a total of 198 octogenarians patients, in three different institutions, were included in this registry. All patients underwent CAS using proximal endovascular occlusion device (Mo.Ma. device Invatec, Roncadelle, Italy). An independent neurologist evaluated all patients. The primary endpoint was death and stroke rate at 30 days. RESULTS: 198 octogenarians (135 men; mean age: 83.2 years) were included in the registry. 39.4% of the patients were symptomatic. Procedural success was 100%. In-hospital complications: Two minor and two major strokes (2.02%) occurred. No device-related complications and no serious access site complication were noted. Between discharge and 30-day follow-up, one patient died due to a cardiac arrest. The overall 30-day combined stroke/death rate was 2.52%, resulting in 1.61% event incidence in asymptomatic and 3.9% in symptomatic patients (P = ns). Logistic regression did not identify independent predictor of neurological events, except in the female gender. CONCLUSION: This multicenter prospective registry shows that CAS performed with proximal flow blockage is safe and feasible also in octogenarians. Thirty days death/stroke rates are similar to those of the overall population and within the International guidelines.


Asunto(s)
Angioplastia/instrumentación , Oclusión con Balón/instrumentación , Estenosis Carotídea/terapia , Embolia Intracraneal/prevención & control , Stents , Anciano de 80 o más Años , Angioplastia/efectos adversos , Angioplastia/mortalidad , Estenosis Carotídea/diagnóstico , Estenosis Carotídea/mortalidad , Diseño de Equipo , Femenino , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/mortalidad , Italia , Modelos Lineales , Modelos Logísticos , Masculino , Selección de Paciente , Guías de Práctica Clínica como Asunto , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...