Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Intervalo de año de publicación
1.
Allergol Immunopathol (Madr) ; 32(4): 228-32, 2004.
Artículo en Español | MEDLINE | ID: mdl-15324654

RESUMEN

BACKGROUND: Determining the risk season for the presence of pollen in the atmosphere aids primary care physicians in the diagnosis and treatment of allergic diseases. Our objective was to identify the taxa of pollen that cause allergic rhinoconjunctivitis in a sample of patients from a health center who presented seasonal symptoms. METHODS: We designed an observational, cross-sectional, non-randomized study to be carried out in the Cazoña Health Center in Santander, Spain. We selected 30 volunteers of both sexes, aged between 13 and 69 year old, who suffered seasonal rhinoconjunctivitis symptoms and who had always lived in Santander. Patients underwent skin-prick tests with the 25 pollen extracts routinely used in Spain, house dust mite (HDM), cat dander and Alternaria extracts by means of the Prick-Film system. The test result was expressed as the percentage of the papule area caused by histamine. Measurement was performed by scanning the copied papule area with the Prick-Scan program for PC. RESULTS: All patients were positive to grass pollen, 26 % were sensitized to grass pollen only and 23 % were also sensitized to other non-pollen allergens. Twenty-seven percent tested positive to Plantago, 20 % to Quercus and 13 % to Morus; the remaining pollen extracts were positive in less than 10 %. Fifty-six percent of the patients were positive to HDM and 6 % to cat dander. CONCLUSIONS: A warning period for pollinosis patients in the city of Santander can be defined. In our case, the important period is the grass pollen season, since the remaining pollen taxa sensitized few patients. Most of our patients were also sensitized to HDM.


Asunto(s)
Alérgenos/inmunología , Plantas/inmunología , Polen/inmunología , Rinitis Alérgica Estacional/etiología , Adolescente , Adulto , Anciano , Alérgenos/farmacología , Animales , Gatos/inmunología , Conjuntivitis Alérgica/epidemiología , Conjuntivitis Alérgica/etiología , Conjuntivitis Alérgica/inmunología , Estudios Transversales , Femenino , Liberación de Histamina/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Ácaros/inmunología , Morus/inmunología , Plantago/inmunología , Plantas/clasificación , Prevalencia , Quercus/inmunología , Rinitis Alérgica Estacional/epidemiología , Rinitis Alérgica Estacional/inmunología , Pruebas Cutáneas , España/epidemiología
2.
Allergol. immunopatol ; 32(4): 228-232, jul. 2004.
Artículo en Es | IBECS | ID: ibc-33761

RESUMEN

Antecedentes: Es de utilidad para los médicos de atención primaria el conocer el periodo de riesgo de presencia atmosférica de polen en su zona. Nuestro objetivo fue identificar los taxones de polen causantes de rinoconjuntivitis alérgica en una muestra de pacientes procedentes de un Centro de Salud, que presentaban síntomas de alergia en relación con la estación polínica. Métodos: Se diseñó un estudio observacional, transversal y no aleatorio, para realizar en el Centro de Salud de Cazoña (Santander, España). Se escogió a treinta pacientes voluntarios, de ambos sexos, entre 13 y 69 años, que padecían síntomas estacionales de rinoconjuntivitis y siempre habían vivido en Santander. Se realizaron pruebas cutáneas con los mismos 25 extractos de polen habitual en España y con extractos de ácaros, epitelio de gato y Alternaria, mediante sistema Prick-Film. El resultado se expresó como porcentaje de área de pápula causada por la histamina, medido por escaneado de la pápula copiada, mediante el programa Prick-Scan para P.C. Resultados: En todos los pacientes las pruebas fueron positivas para polen de gramíneas, el 26 por ciento estaba sensibilizado solamente a gramíneas y el 23 por ciento era alérgico además a otro alergeno no polínico. El 27 por ciento fue positivo con Plantago, 20 por ciento con Quercus y 13 por ciento con Morus; el resto de los taxones fueron positivos en menos del 10 por ciento. El 56 por ciento fue positivo con ácaros y 6 por ciento con epitelio de gato. Conclusiones: Se puede considerar un periodo de alerta para los polínicos de la ciudad. En este caso, el periodo de polinización de las gramíneas, pues otros taxones sensibilizaron a pocos pacientes. Los polínicos estaban además mayoritariamente sensibilizados a ácaros (AU)


Background: Determining the risk season for the presence of pollen in the atmosphere aids primary care physicians in the diagnosis and treatment of allergic diseases. Our objective was to identify the taxa of pollen that cause allergic rhinoconjunctivitis in a sample of patients from a health center who presented seasonal symptoms. Methods: We designed an observational, cross-sectional, non-randomized study to be carried out in the Cazoña Health Center in Santander, Spain. We selected 30 volunteers of both sexes, aged between 13 and 69 year old, who suffered seasonal rhinoconjunctivitis symptoms and who had always lived in Santander. Patients underwent skin-prick tests with the 25 pollen extracts routinely used in Spain, house dust mite (HDM), cat dander and Alternaria extracts by means of the Prick-Film® system. The test result was expressed as the percentage of the papule area caused by histamine. Measurement was performed by scanning the copied papule area with the Prick-Scan® program for PC. Results: All patients were positive to grass pollen, 26 % were sensitized to grass pollen only and 23 % were also sensitized to other non-pollen allergens. Twenty-seven percent tested positive to Plantago, 20 % to Quercus and 13 % to Morus; the remaining pollen extracts were positive in less than 10 %. Fifty-six percent of the patients were positive to HDM and 6 % to cat dander. Conclusions: A warning period for pollinosis patients in the city of Santander can be defined. In our case, the important period is the grass pollen season, since the remaining pollen taxa sensitized few patients. Most of our patients were also sensitized to HDM (AU)


Asunto(s)
Anciano , Adulto , Animales , Gatos , Adolescente , Femenino , Humanos , Persona de Mediana Edad , Masculino , Polen , Alérgenos , Conjuntivitis Alérgica , Estudios Transversales , Liberación de Histamina , Quercus , España , Morus , Plantago , Plantas , Prevalencia , Conjuntivitis Alérgica , Ácaros , Rinitis Alérgica Estacional , Pruebas Cutáneas
3.
Alergol. inmunol. clín. (Ed. impr.) ; 16(2): 84-90, abr. 2001. tab, graf
Artículo en Es | IBECS | ID: ibc-1585

RESUMEN

Fundamento: El especialista debe conocer bien la aerobiología particular de la zona en que vive la población que atiende. Se pretende conocer los taxones de polen atmosférico más frecuentes en Santander, y cuales producen más sensibilizaciones, así como se estudia la influencia del clima atlántico. Métodos: Recuentos de polen de 24 horas, desde mayo de 1998 a abril de 2000, mediante método volumétrico. Pruebas de prick con la misma batería de pólenes a 50 pacientes de Santander con clínica de polinosis. Se correlacionaron los recuentos mensuales de gramíneas con las ventas mensuales de antihistamínicos en la ciudad. Se correlacionaron los recuentos de gramíneas en mayo y junio con los correspondientes datos meteorológicos. Resultados: Los tipos polínicos más frecuentes fueron: poaceae (28,79 por ciento), urticaceae (19,05 por ciento), Platanus (7,80 por ciento), Quercus (5,71 por ciento), Pinus (5,07 por ciento) y Plantago (5,05 por ciento).Las pruebas cutáneas positivas fueron: Lolium (98 por ciento) y Plantago (65 por ciento), Chenopodium (20 por ciento), Artemisa (12 por ciento), Platanus (14 por ciento), Betula (14 por ciento), Olea (12 por ciento), Quercus (6 por ciento) y Parietaria (4 por ciento). Se encontró correlación de los valores mensuales de recuentos de gramíneas con los de ventas de antihistamínicos. Se encontraron recuentos con valores de gramíneas superiores a 45 granos/m3 más frecuentemente entre los correspondientes a 24 horas sin precipitación registrada o con viento del Este en las horas previas al recuento, que entre los recuentos coincidentes con alguna precipitación o viento del Oeste. Se encontró correlación del recuento de 24 h de polen de gramíneas con los registros de precipitación y con la temperatura máxima. Conclusiones: El polen de gramíneas es el predominante en la atmósfera de Santander y es la causa más frecuente de polinosis. Durante su período de polinización la variación diaria de precipitación, temperatura y dirección del viento influye en su incidencia atmosférica. (AU)


Asunto(s)
Adolescente , Adulto , Femenino , Masculino , Niño , Humanos , Polen/efectos adversos , Alérgenos/aislamiento & purificación , Monitoreo del Aire , Contaminantes Atmosféricos/aislamiento & purificación , Antialérgicos/provisión & distribución , Antialérgicos/uso terapéutico , Hipersensibilidad Respiratoria/epidemiología , Efectos del Clima , Poaceae/efectos adversos , Pruebas Cutáneas
4.
Rev Sanid Hig Publica (Madr) ; 66(3-4): 197-201, 1992.
Artículo en Español | MEDLINE | ID: mdl-1366215

RESUMEN

BACKGROUND: The recent Spanish legislation on drinkable waters for public use includes a paragraph establishing the requirements to be fulfilled by waters in relation with their radioactivity and the methods to be used to measure it. As water radioactivity depends on the radioactive content of the grounds and rocks where it flows, it is possible to expect high levels in those zones whose characteristic is their high level of natural radiation. METHODS: For this reason, we have organized two measurement campaigns with the objective of characterizing the drinkable waters in an Spanish area, where the radioactive elements concentration in the ground is high. The methodology used is as described in legislation, using a low-bottomed proportional counter. RESULTS: The results we have obtained indicate that the zone, where measurements have been made, shows lower radioactivity levels than the legally established limits, nevertheless, at same time, there appear several points, where the radioactivity levels are high, showing values exceeding in great measure the legal limit for drinkable waters. CONCLUSIONS: With the results, we have obtained, its seems necessary that a greater attention is paid to drinkable waters in those points, where the radioactivity levels are high including corrective measures.


Asunto(s)
Radiación de Fondo , Abastecimiento de Agua , Partículas alfa , Partículas beta , España , Contaminantes Radiactivos del Agua/análisis , Abastecimiento de Agua/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...