Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Nat Sci Sleep ; 10: 203-215, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30046256

RESUMEN

BACKGROUND: Melatonin is a neuroendocrine hormone that regulates many functions involving energy metabolism and behavior in mammals throughout the light/dark cycle. It is considered an output signal of the central circadian clock, located in the suprachiasmatic nucleus of the hypothalamus. Melatonin synthesis can be influenced by other hormones, such as insulin and glucocorticoids in pathological conditions or during stress. Furthermore, glucocorticoids appear to modulate circadian clock genes in peripheral tissues and are associated with the onset of metabolic diseases. In the pineal gland, the modulation of melatonin synthesis by clock genes has already been demonstrated. However, few studies have shown the effects of glucocorticoids on clock genes expression in the pineal gland. RESULTS: We verified that rats treated with dexamethasone (2 mg/kg body weight, intraperitoneal) for 10 consecutive days, showed hyperglycemia and pronounced hyperinsulinemia during the dark phase. Insulin sensitivity, glucose tolerance, melatonin synthesis, and enzymatic activity of arylalkylamine N-acetyltransferase, the key enzyme of melatonin synthesis, were reduced. Furthermore, we observed an increase in the expression of Bmal1, Per1, Per2, Cry1, and Cry2 in pineal glands of rats treated with dexamethasone. CONCLUSION: These results show that chronic treatment with dexamethasone can modulate both melatonin synthesis and circadian clock expression during the dark phase.

2.
Radiol. bras ; 47(3): 159-164, May-Jun/2014. tab, graf
Artículo en Portugués | LILACS | ID: lil-713632

RESUMEN

Objetivo: Avaliar a situação atual da braquiterapia de alta taxa dose (BATD) realizada no Brasil para neoplasias do colo uterino, no que diz respeito aos aparelhos, métodos de planejamento, prescrições, fracionamentos e avaliações de dose nos órgãos de risco. Materiais e Métodos: Foi elaborado um questionário contendo questões de múltipla escolha, o qual, entre os meses de março de 2012 e maio de 2013, foi enviado a 89 instituições hospitalares de todo o Brasil que possuem equipamento de BATD. Resultados: Sessenta e um serviços responderam o questionário. Todas as regiões do País experimentaram aumento acentuado no número de serviços que oferecem BATD entre os anos de 2001 e 2013. Quanto aos planejamentos, apesar de 91% dos centros afirmarem que possuem softwares capazes de suportar planejamento tridimensional, o aparelho de raios X convencional foi apontado por 92% dos entrevistados como ferramenta de aquisição de imagens na rotina. Aproximadamente 35% dos entrevistados afirmaram que as sessões de braquiterapia são realizadas após a teleterapia. O esquema de quatro inserções de 7 Gy foi apontado como o mais praticado. Conclusão: Neste estudo percebeu-se que há dificuldade dos profissionais ao acesso às ferramentas de aquisição de imagens adjuvantes aos planejamentos tridimensionais, como tomografia computadorizada e ressonância magnética. .


Objective: To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. Materials and Methods: In the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. Results: Sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. Conclusion: The authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging. .

3.
Radiol Bras ; 47(3): 159-64, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25741073

RESUMEN

OBJECTIVE: To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. MATERIALS AND METHODS: In the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. RESULTS: Sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. CONCLUSION: The authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging.


OBJETIVO: Avaliar a situação atual da braquiterapia de alta taxa dose (BATD) realizada no Brasil para neoplasias do colo uterino, no que diz respeito aos aparelhos, métodos de planejamento, prescrições, fracionamentos e avaliações de dose nos órgãos de risco. MATERIAIS E MÉTODOS: Foi elaborado um questionário contendo questões de múltipla escolha, o qual, entre os meses de março de 2012 e maio de 2013, foi enviado a 89 instituições hospitalares de todo o Brasil que possuem equipamento de BATD. RESULTADOS: Sessenta e um serviços responderam o questionário. Todas as regiões do País experimentaram aumento acentuado no número de serviços que oferecem BATD entre os anos de 2001 e 2013. Quanto aos planejamentos, apesar de 91% dos centros afirmarem que possuem softwares capazes de suportar planejamento tridimensional, o aparelho de raios X convencional foi apontado por 92% dos entrevistados como ferramenta de aquisição de imagens na rotina. Aproximadamente 35% dos entrevistados afirmaram que as sessões de braquiterapia são realizadas após a teleterapia. O esquema de quatro inserções de 7 Gy foi apontado como o mais praticado. CONCLUSÃO: Neste estudo percebeu-se que há dificuldade dos profissionais ao acesso às ferramentas de aquisição de imagens adjuvantes aos planejamentos tridimensionais, como tomografia computadorizada e ressonância magnética.

4.
Radiol. bras ; 44(2): 104-108, mar.-abr. 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-588196

RESUMEN

OBJETIVO: O objetivo deste trabalho foi verificar a aceitabilidade para a implantação no Brasil de um banco de objetos simuladores nacional, ou bancos regionais, para uso compartilhado desses objetos em atividades de controle de qualidade nos serviços de medicina nuclear. MATERIAIS E MÉTODOS: Foram analisadas as respostas dadas em um questionário que foi enviado a supervisores de radioproteção e físicos médicos de serviços de medicina nuclear do Brasil. Inicialmente, o questionário foi validado por profissionais da cidade de Aracaju, SE, que está localizada no Nordeste. De acordo com as regiões geográficas brasileiras, fizeram parte da amostra investigada: o Nordeste, com respostas de profissionais de 13 serviços de medicina nuclear; o Norte, com 2 profissionais; o Sul, com 7 profissionais; o Sudeste, com 43 profissionais; e o Centro-Oeste, com 2 profissionais. RESULTADOS: Segundo os dados analisados, 82 por cento dos entrevistados consideram que a implantação de um banco de simuladores seria uma alternativa apropriada para o aprimoramento do controle de qualidade em medicina nuclear. O interesse em compartilhar com o banco foi de 87 por cento. CONCLUSÃO: Os resultados mostraram que há motivação para o compartilhamento de objetos simuladores, ou seja, para o uso desses objetos de forma socializada.


OBJECTIVE: The present study was aimed at determining the acceptability of a national or regional phantoms bank to be deployed in Brazil for shared use in quality control activities by nuclear medicine centers. MATERIALS AND METHODS: The authors analyzed the answers to a questionnaire applied to medical physicists and radioprotection supervisors in Brazilian nuclear medicine centers. Initially, the questionnaire was validated by professionals in the city of Aracaju, SE, which is located in the Northeast region. The present study sample was geographically distributed as follows: the Northeast region, with answers from 13 professionals of nuclear medicine centers; the North region, with 2 professionals; the South region, with 7 professionals; the Southeast region, with 43 professionals; and the Midwest region, with 2 professionals. RESULTS: According to the data analyzed, 82 percent of the respondents consider that the implementation of a phantoms bank would be a suitable alternative for improving nuclear medicine quality control. The interest in sharing the bank was reported by 87 percent of the respondents. CONCLUSION: The present study demonstrated the motivation for a shared use of a future phantoms bank.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...