Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Chempluschem ; : e202400165, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38829273

RESUMEN

Escalating biodiesel production led to a surplus of glycerol, prompting its exploration as a valuable resource in industrial applications. Electrochemical systems have been studied, specifically employing noble metal catalysts like palladium for glycerol electrooxidation. Despite numerous studies on Pd-based catalysts for glycerol electrooxidation, a comprehensive analysis addressing critical questions related to the economic feasibility, global sourcing of Pd, and the thematic cohesion of publications in this field is lacking. Moreover, a standardized framework for comparing the results of various studies is absent, hindering progress on glycerol technologies. This critical overview navigates the evolution of Pd-based catalysts for glycerol electrooxidation, examining catalytic activity, stability, and potential applications. It critically addresses the geographical sources of Pd, the motivation behind glycerol technology exploration, thematic coherence in existing publications, and the meaningful comparison of results. It correlates the use of Pd-based catalysts with the natural source of Pd and the origin of glycerol derived from biodiesel. The proposed standardized approach for comparing electrochemical parameters and establishing experimental protocols provides a foundation for meaningful study comparisons. This critical overview underscores the need to address fundamental questions to accelerate the transition of glycerol technologies from laboratories to practical applications.

3.
Brain Stimul ; 17(2): 184-193, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38342363

RESUMEN

BACKGROUND: The operation of a transcranial magnetic stimulation (TMS) coil produces high-intensity impulse sounds. In TMS, a magnetic field is generated by a short-duration pulse in the range of thousands of amperes in the TMS coil. When placed in a strong magnetic field, such as inside a magnetic resonance imaging (MRI) bore, the interaction of the magnetic field and the current in the TMS coil can cause strong forces on the coil casing. The strengths of these forces depend on the coil orientation in the main magnetic field (B0). Part of the energy in this process is dissipated in the form of acoustic noise. OBJECTIVE: Our objective was to measure the sound pressure levels (SPL) of TMS "click" sounds created by commercial TMS stimulators and coils in a typical environment and inside a 3-T MRI scanner and advance the knowledge of the acoustic behaviour of TMS to safely conduct TMS alone as well as concurrently with functional MRI (fMRI). METHODS: We report SPL measurements of two commercial MRI-compatible TMS systems in the 3-T B0 field of an MRI scanner and in the earth's magnetic field. Also, we present the acoustic noise measurements of four commercial TMS stimulators and three different TMS coils in a typical operational environment without the B0 field. RESULTS: The maximum peak SPL measured was 158 dB(C) inside the 3-T MRI scanner. Outside the scanner, the maximum peak SPL was 117 dB(C). Inside the scanner, the peak SPL increased by 21-45 dB(C) depending on the stimulator and the orientation of the electric field relative to the B field. CONCLUSIONS: Hearing protection is obligatory during concurrent TMS-fMRI experiments and highly recommended during any TMS experiment. The manufacturing of quieter TMS systems is encouraged to reduce the risk of hearing damage and other unwanted effects.


Asunto(s)
Imagen por Resonancia Magnética , Ruido , Estimulación Magnética Transcraneal , Imagen por Resonancia Magnética/instrumentación , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Humanos , Acústica/instrumentación
7.
Scand J Med Sci Sports ; 33(12): 2524-2533, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37642219

RESUMEN

The neurophysiological mechanisms underlying muscle force control for different wrist postures still need to be better understood. To further elucidate these mechanisms, the present study aimed to investigate the effects of wrist posture on the corticospinal excitability by transcranial magnetic stimulation (TMS) of extrinsic (flexor [FCR] and extensor carpi radialis [ECR]) and intrinsic (flexor pollicis brevis (FPB)) muscles at rest and during a submaximal handgrip strength task. Fourteen subjects (24.06 ± 2.28 years) without neurological or motor disorders were included. We assessed how the wrist posture (neutral: 0°; flexed: +45°; extended: -45°) affects maximal handgrip strength (HGSmax ) and the motor evoked potentials (MEP) amplitudes during rest and active muscle contractions. HGSmax was higher at 0° (133%) than at -45° (93.6%; p < 0.001) and +45° (73.9%; p < 0.001). MEP amplitudes were higher for the FCR at +45° (83.6%) than at -45° (45.2%; p = 0.019) and at +45° (156%; p < 0.001) and 0° (146%; p = 0.014) than at -45° (106%) at rest and active condition, respectively. Regarding the ECR, the MEP amplitudes were higher at -45° (113%) than at +45° (60.8%; p < 0.001) and 0° (72.6%; p = 0.008), and at -45° (138%) than +45° (96.7%; p = 0.007) also at rest and active conditions, respectively. In contrast, the FPB did not reveal any difference among wrist postures and conditions. Although extrinsic and intrinsic hand muscles exhibit overlapping cortical representations and partially share the same innervation, they can be modulated differently depending on the biomechanical constraints.


Asunto(s)
Fuerza de la Mano , Músculo Esquelético , Humanos , Electromiografía , Fuerza de la Mano/fisiología , Músculo Esquelético/fisiología , Muñeca/fisiología , Extremidad Superior , Contracción Muscular/fisiología , Potenciales Evocados Motores/fisiología , Estimulación Magnética Transcraneal
8.
Sci Rep ; 13(1): 8225, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37217502

RESUMEN

The analysis of motor evoked potentials (MEPs) generated by transcranial magnetic stimulation (TMS) is crucial in research and clinical medical practice. MEPs are characterized by their latency and the treatment of a single patient may require the characterization of thousands of MEPs. Given the difficulty of developing reliable and accurate algorithms, currently the assessment of MEPs is performed with visual inspection and manual annotation by a medical expert; making it a time-consuming, inaccurate, and error-prone process. In this study, we developed DELMEP, a deep learning-based algorithm to automate the estimation of MEP latency. Our algorithm resulted in a mean absolute error of about 0.5 ms and an accuracy that was practically independent of the MEP amplitude. The low computational cost of the DELMEP algorithm allows employing it in on-the-fly characterization of MEPs for brain-state-dependent and closed-loop brain stimulation protocols. Moreover, its learning ability makes it a particularly promising option for artificial-intelligence-based personalized clinical applications.


Asunto(s)
Aprendizaje Profundo , Corteza Motora , Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Estimulación Magnética Transcraneal/métodos , Algoritmos , Electromiografía
9.
Phys Eng Sci Med ; 46(2): 887-896, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37166586

RESUMEN

Navigated transcranial magnetic stimulation (nTMS) is a valuable tool for non-invasive brain stimulation. Currently, nTMS requires fixing of markers on the patient's head. Head marker displacements lead to changes in coil placement and brain stimulation inaccuracy. A markerless neuronavigation method is needed to increase the reliability of nTMS and simplify the nTMS protocol. In this study, we introduce and release MarLe, a Python markerless head tracker neuronavigation software for TMS. This novel software uses computer-vision techniques combined with low-cost cameras to estimate the head pose for neuronavigation. A coregistration algorithm, based on a closed-form solution, was designed to track the patient's head and the TMS coil referenced to the individual's brain image. We show that MarLe can estimate head pose based on real-time video processing. An intuitive pipeline was developed to connect the MarLe and nTMS neuronavigation software. MarLe achieved acceptable accuracy and stability in a mockup nTMS experiment. MarLe allows real-time tracking of the patient's head without any markers. The combination of face detection and a coregistration algorithm can overcome nTMS head marker displacement concerns. MarLe can improve reliability, simplify, and reduce the protocol time of brain intervention techniques such as nTMS.


Asunto(s)
Neoplasias Encefálicas , Estimulación Magnética Transcraneal , Humanos , Estimulación Magnética Transcraneal/métodos , Reproducibilidad de los Resultados , Mapeo Encefálico/métodos , Encéfalo
10.
IEEE Trans Biomed Eng ; 70(7): 2025-2034, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37018249

RESUMEN

OBJECTIVE: This work aims for a method to design manufacturable windings for transcranial magnetic stimulation (TMS) coils with fine control over the induced electric field (E-field) distributions. Such TMS coils are required for multi-locus TMS (mTMS). METHODS: We introduce a new mTMS coil design workflow with increased flexibility in target E-field definition and faster computations compared to our previous method. We also incorporate custom current density and E-field fidelity constraints to ensure that the target E-fields are accurately reproduced with feasible winding densities in the resulting coil designs. We validated the method by designing, manufacturing, and characterizing a 2-coil mTMS transducer for focal rat brain stimulation. RESULTS: Applying the constraints reduced the computed maximum surface current densities from 15.4 and 6.6 kA/mm to the target value 4.7 kA/mm, yielding winding paths suitable for a 1.5-mm-diameter wire with 7-kA maximum currents while still replicating the target E-fields with the predefined 2.8% maximum error in the FOV. The optimization time was reduced by two thirds compared to our previous method. CONCLUSION: The developed method allowed us to design a manufacturable, focal 2-coil mTMS transducer for rat TMS impossible to attain with our previous design workflow. SIGNIFICANCE: The presented workflow enables considerably faster design and manufacturing of previously unattainable mTMS transducers with increased control over the induced E-field distribution and winding density, opening new possibilities for brain research and clinical TMS.


Asunto(s)
Encéfalo , Estimulación Magnética Transcraneal , Animales , Ratas , Estimulación Magnética Transcraneal/métodos , Encéfalo/fisiología , Cabeza , Técnicas Estereotáxicas , Transductores
11.
Brain Sci ; 13(3)2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36979228

RESUMEN

Coregistration of transcranial magnetic stimulation (TMS) and electroencephalography (EEG) allows non-invasive probing of brain circuits: TMS induces brain activation due to the generation of a properly oriented focused electric field (E-field) using a coil placed on a selected position over the scalp, while EEG captures the effects of the stimulation on brain electrical activity. Moreover, the combination of these techniques allows the investigation of several brain properties, including brain functional connectivity. The choice of E-field parameters, such as intensity, orientation, and position, is crucial for eliciting cortex-specific effects. Here, we evaluated whether and how the spatial pattern, i.e., topography and strength of functional connectivity, is modulated by the stimulus orientation. We systematically altered the E-field orientation when stimulating the left pre-supplementary motor area and showed an increase of functional connectivity in areas associated with the primary motor cortex and an E-field orientation-specific modulation of functional connectivity intensity.

12.
Stem Cells Int ; 2022: 5111782, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35371263

RESUMEN

Global prevalence of chronic kidney disease (CKD) has increased considerably in the recent decades. Overactivity of the renin-angiotensin-aldosterone system (RAAS), associated to renal inflammation and fibrosis, contributes to its evolution. The treatments currently employed to control CKD progression are limited and mainly based on the pharmacological inhibition of RAAS, associated with diuretics and immunosuppressive drugs. However, this conservative management promotes only partial deceleration of CKD evolution and does not completely avoid the progression of the disease and the loss of renal function, which motivates the medical and scientific community to investigate new therapeutic approaches to detain renal inflammation/fibrosis and CKD progression. Recent studies have shown the application of mesenchymal stem cells (mSC) to exert beneficial effects on the renal tissue of animals submitted to experimental models of CKD. In this context, the aim of the present study was to evaluate the effects of subcapsular application of adipose tissue-derived mSC (ASC) in rats submitted to the 5/6 renal ablation model, 15 days after the establishment of CKD, when the nephropathy was already severe. We also verify whether ASC associated to Losartan would promote greater renoprotection when compared to the respective monotherapies. Animals were followed until 30 days of CKD, when body weight, systolic blood pressure, biochemical, histological, immunohistochemical, and gene expression analysis were performed. The combination of ASC and Losartan was more effective than Losartan monotherapy in reducing systolic blood pressure and glomerulosclerosis and also promoted the complete normalization of proteinuria and albuminuria, a significant reduction in renal interstitial macrophage infiltration and downregulation of renal IL-6 gene expression. The beneficial effects of ACS are possibly due to the immunomodulatory and anti-inflammatory role of factors secreted by these cells, modulating the local immune response. Although studies are still required, our results demonstrated that a subcapsular inoculation of ASC, associated with the administration of Losartan, exerted additional renoprotective effect in rats submitted to a severe model of established CKD, when compared to Losartan monotherapy, thus suggesting ASC may be a potential adjuvant to RAAS-blockade therapy currently employed in the conservative management of CKD.

13.
Brain Topogr ; 35(3): 322-336, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35262840

RESUMEN

Most of the motor mapping procedures using navigated transcranial magnetic stimulation (nTMS) follow the conventional somatotopic organization of the primary motor cortex (M1) by assessing the representation of a particular target muscle, disregarding the possible coactivation of synergistic muscles. In turn, multiple reports describe a functional organization of the M1 with an overlapping among motor representations acting together to execute movements. In this context, the overlap degree among cortical representations of synergistic hand and forearm muscles remains an open question. This study aimed to evaluate the muscle coactivation and representation overlapping common to the grasping movement and its dependence on the stimulation parameters. The nTMS motor maps were obtained from one carpal muscle and two intrinsic hand muscles during rest. We quantified the overlapping motor maps in size (area and volume overlap degree) and topography (similarity and centroid Euclidean distance) parameters. We demonstrated that these muscle representations are highly overlapped and similar in shape. The overlap degrees involving the forearm muscle were significantly higher than only among the intrinsic hand muscles. Moreover, the stimulation intensity had a stronger effect on the size compared to the topography parameters. Our study contributes to a more detailed cortical motor representation towards a synergistic, functional arrangement of M1. Understanding the muscle group coactivation may provide more accurate motor maps when delineating the eloquent brain tissue during pre-surgical planning.


Asunto(s)
Corteza Motora , Mapeo Encefálico/métodos , Potenciales Evocados Motores/fisiología , Antebrazo/fisiología , Mano , Humanos , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Estimulación Magnética Transcraneal/métodos
14.
Brain Stimul ; 15(2): 523-531, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35337598

RESUMEN

BACKGROUND: Transcranial magnetic stimulation (TMS) is widely used in brain research and treatment of various brain dysfunctions. However, the optimal way to target stimulation and administer TMS therapies, for example, where and in which electric field direction the stimuli should be given, is yet to be determined. OBJECTIVE: To develop an automated closed-loop system for adjusting TMS parameters (in this work, the stimulus orientation) online based on TMS-evoked brain activity measured with electroencephalography (EEG). METHODS: We developed an automated closed-loop TMS-EEG set-up. In this set-up, the stimulus parameters are electronically adjusted with multi-locus TMS. As a proof of concept, we developed an algorithm that automatically optimizes the stimulation orientation based on single-trial EEG responses. We applied the algorithm to determine the electric field orientation that maximizes the amplitude of the TMS-EEG responses. The validation of the algorithm was performed with six healthy volunteers, repeating the search twenty times for each subject. RESULTS: The validation demonstrated that the closed-loop control worked as desired despite the large variation in the single-trial EEG responses. We were often able to get close to the orientation that maximizes the EEG amplitude with only a few tens of pulses. CONCLUSION: Optimizing stimulation with EEG feedback in a closed-loop manner is feasible and enables effective coupling to brain activity.


Asunto(s)
Electroencefalografía , Estimulación Magnética Transcraneal , Encéfalo/fisiología , Mapeo Encefálico , Retroalimentación , Humanos
15.
Open Res Eur ; 2: 45, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36035767

RESUMEN

Background: Spontaneous cortical oscillations have been shown to modulate cortical responses to transcranial magnetic stimulation (TMS). However, whether these oscillations influence cortical effective connectivity is largely unknown. We conducted a pilot study to set the basis for addressing how spontaneous oscillations affect cortical effective connectivity measured through TMS-evoked potentials (TEPs). Methods: We applied TMS to the left primary motor cortex and right pre-supplementary motor area of three subjects while recording EEG. We classified trials off-line into positive- and negative-phase classes according to the mu and beta rhythms. We calculated differences in the global mean-field amplitude (GMFA) and compared the cortical spreading of the TMS-evoked activity between the two classes. Results: Phase affected the GMFA in four out of 12 datasets (3 subjects × 2 stimulation sites × 2 frequency bands). Two of the observed significant intervals were before 50 ms, two between 50 and 100 ms, and one after 100 ms post-stimulus. Source estimates showed complex spatial differences between the classes in the cortical spreading of the TMS-evoked activity. Conclusions: TMS-evoked effective connectivity seems to depend on the phase of local cortical oscillations at the stimulated site. This work paves the way to design future closed-loop stimulation paradigms.

16.
Brain Stimul ; 15(1): 116-124, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34818580

RESUMEN

BACKGROUND: Transcranial magnetic stimulation (TMS) allows non-invasive stimulation of the cortex. In multi-locus TMS (mTMS), the stimulating electric field (E-field) is controlled electronically without coil movement by adjusting currents in the coils of a transducer. OBJECTIVE: To develop an mTMS system that allows adjusting the location and orientation of the E-field maximum within a cortical region. METHODS: We designed and manufactured a planar 5-coil mTMS transducer to allow controlling the maximum of the induced E-field within a cortical region approximately 30 mm in diameter. We developed electronics with a design consisting of independently controlled H-bridge circuits to drive up to six TMS coils. To control the hardware, we programmed software that runs on a field-programmable gate array and a computer. To induce the desired E-field in the cortex, we developed an optimization method to calculate the currents needed in the coils. We characterized the mTMS system and conducted a proof-of-concept motor-mapping experiment on a healthy volunteer. In the motor mapping, we kept the transducer placement fixed while electronically shifting the E-field maximum on the precentral gyrus and measuring electromyography from the contralateral hand. RESULTS: The transducer consists of an oval coil, two figure-of-eight coils, and two four-leaf-clover coils stacked on top of each other. The technical characterization indicated that the mTMS system performs as designed. The measured motor evoked potential amplitudes varied consistently as a function of the location of the E-field maximum. CONCLUSION: The developed mTMS system enables electronically targeted brain stimulation within a cortical region.


Asunto(s)
Corteza Motora , Estimulación Magnética Transcraneal , Electromiografía/métodos , Potenciales Evocados Motores , Humanos , Corteza Motora/fisiología , Técnicas Estereotáxicas , Estimulación Magnética Transcraneal/métodos
17.
J Neural Eng ; 18(6)2021 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-34673563

RESUMEN

Objective. Coils designed for transcranial magnetic stimulation (TMS) must incorporate trade-offs between the required electrical power or energy, focality and depth penetration of the induced electric field (E-field), coil size, and mechanical properties of the coil, as all of them cannot be optimally met at the same time. In multi-locus TMS (mTMS), a transducer consisting of several coils allows electronically targeted stimulation of the cortex without physically moving a coil. In this study, we aimed to investigate the relationship between the number of coils in an mTMS transducer, the focality of the induced E-field, and the extent of the cortical region within which the location and orientation of the maximum of the induced E-field can be controlled.Approach.We applied convex optimization to design planar and spherically curved mTMS transducers of different E-field focalities and analyzed their properties. We characterized the trade-off between the focality of the induced E-field and the extent of the cortical region that can be stimulated with an mTMS transducer with a given number of coils.Main results.At the expense of the E-field focality, one can, with the same number of coils, design an mTMS transducer that can control the location and orientation of the peak of the induced E-field within a wider cortical region.Significance. With E-fields of moderate focality, the problem of electronically targeted TMS becomes considerably easier compared with highly focal E-fields; this may speed up the development of mTMS and the emergence of new clinical and research applications.


Asunto(s)
Encéfalo , Estimulación Magnética Transcraneal , Encéfalo/fisiología , Estimulación Magnética Transcraneal/métodos
18.
PLoS One ; 16(9): e0257554, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34550997

RESUMEN

Besides stimulus intensities and interstimulus intervals (ISI), the electric field (E-field) orientation is known to affect both short-interval intracortical inhibition (SICI) and facilitation (SICF) in paired-pulse transcranial magnetic stimulation (TMS). However, it has yet to be established how distinct orientations of the conditioning (CS) and test stimuli (TS) affect the SICI and SICF generation. With the use of a multi-channel TMS transducer that provides electronic control of the stimulus orientation and intensity, we aimed to investigate how changes in the CS and TS orientation affect the strength of SICI and SICF. We hypothesized that the CS orientation would play a major role for SICF than for SICI, whereas the CS intensity would be more critical for SICI than for SICF. In eight healthy subjects, we tested two ISIs (1.5 and 2.7 ms), two CS and TS orientations (anteromedial (AM) and posteromedial (PM)), and four CS intensities (50, 70, 90, and 110% of the resting motor threshold (RMT)). The TS intensity was fixed at 110% RMT. The intensities were adjusted to the corresponding RMT in the AM and PM orientations. SICI and SICF were observed in all tested CS and TS orientations. SICI depended on the CS intensity in a U-shaped manner in any combination of the CS and TS orientations. With 70% and 90% RMT CS intensities, stronger PM-oriented CS induced stronger inhibition than weaker AM-oriented CS. Similar SICF was observed for any CS orientation. Neither SICI nor SICF depended on the TS orientation. We demonstrated that SICI and SICF could be elicited by the CS perpendicular to the TS, which indicates that these stimuli affected either overlapping or strongly connected neuronal populations. We concluded that SICI is primarily sensitive to the CS intensity and that CS intensity adjustment resulted in similar SICF for different CS orientations.


Asunto(s)
Potenciales Evocados Motores/fisiología , Inhibición Neural/fisiología , Estimulación Magnética Transcraneal/métodos , Adulto , Electromiografía , Voluntarios Sanos , Humanos , Masculino , Corteza Motora/fisiología , Adulto Joven
19.
RSC Adv ; 9(27): 15158-15161, 2019 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-35514849

RESUMEN

We turned printed plastic pieces into a conductive material by electrochemical polymerization of aniline on the plastic surface assisted by graphite. The conductive piece was then turned into a metallic electrode by potentiodynamic electrodeposition. As a proof-of-concept, we built indirect-3D-printed Pd, Pt and Au electrodes, which were used for glycerol electrooxidation.

20.
HLA ; 92(5): 298-303, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30225991

RESUMEN

The aim of this study was to determine the allele and haplotype frequencies of HLA-A, -B, -DRB1, and -DQB1 in a self-declared White population from the north and northwestern state of Paraná, southern Brazil, and compare the data with populations worldwide. The genotyping was performed with a group of 641 individuals, based on PCR-SSO and -SSP methods, and allele and haplotype frequencies were estimated. Comparisons with European, African, Asian, and Amerindian populations were performed. The most frequent allelic groups, alleles and haplotypes were: HLA-A*02, HLA-B*35, HLA-DRB1*07:01, HLA-DQB1*03:01, and HLA-A*01/B*08/DRB1*03:01. The results reinforced a predominance of a European composition in the self-declared White population from the north and northwestern Paraná.


Asunto(s)
Genética de Población , Antígenos HLA-A/genética , Antígenos HLA-B/genética , Cadenas alfa de HLA-DQ/genética , Cadenas beta de HLA-DQ/genética , Cadenas HLA-DRB1/genética , Haplotipos , Adulto , Alelos , Brasil , Femenino , Frecuencia de los Genes , Voluntarios Sanos , Humanos , Masculino , Polimorfismo Genético
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...