Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Epidemiol Infect ; 146(7): 920-930, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29636119

RESUMEN

Coinfection with human immunodeficiency virus (HIV) and viral hepatitis is associated with high morbidity and mortality in the absence of clinical management, making identification of these cases crucial. We examined characteristics of HIV and viral hepatitis coinfections by using surveillance data from 15 US states and two cities. Each jurisdiction used an automated deterministic matching method to link surveillance data for persons with reported acute and chronic hepatitis B virus (HBV) or hepatitis C virus (HCV) infections, to persons reported with HIV infection. Of the 504 398 persons living with diagnosed HIV infection at the end of 2014, 2.0% were coinfected with HBV and 6.7% were coinfected with HCV. Of the 269 884 persons ever reported with HBV, 5.2% were reported with HIV. Of the 1 093 050 persons ever reported with HCV, 4.3% were reported with HIV. A greater proportion of persons coinfected with HIV and HBV were males and blacks/African Americans, compared with those with HIV monoinfection. Persons who inject drugs represented a greater proportion of those coinfected with HIV and HCV, compared with those with HIV monoinfection. Matching HIV and viral hepatitis surveillance data highlights epidemiological characteristics of persons coinfected and can be used to routinely monitor health status and guide state and national public health interventions.


Asunto(s)
Coinfección/epidemiología , Infecciones por VIH/epidemiología , Hepatitis Viral Humana/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Coinfección/virología , Femenino , Infecciones por VIH/virología , Hepatitis Viral Humana/virología , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Salud Pública , Estados Unidos/epidemiología , Adulto Joven
2.
Analyst ; 141(3): 902-9, 2016 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-26779571

RESUMEN

The potential of IR absorption and Raman spectroscopy for rapid identification of novel psychoactive substances (NPS) has been tested using a set of 221 unsorted seized samples suspected of containing NPS. Both IR and Raman spectra showed large variation between the different sub-classifications of NPS and smaller, but still distinguishable, differences between closely related compounds within the same class. In initial tests, screening the samples using spectral searching against a limited reference library allowed only 41% of the samples to be fully identified. The limiting factor in the identification was the large number of active compounds in the seized samples for which no reference vibrational data were available in the libraries rather than poor spectral quality. Therefore, when 33 of these compounds were independently identified by NMR and mass spectrometry and their spectra used to extend the libraries, the percentage of samples identified by IR and Raman screening alone increased to 76%, with only 7% of samples having no identifiable constituents. This study, which is the largest of its type ever carried out, therefore demonstrates that this approach of detecting non-matching samples and then identifying them using standard analytical methods has considerable potential in NPS screening since it allows rapid identification of the constituents of the majority of street quality samples. Only one complete feedback cycle was carried out in this study but there is clearly the potential to carry out continuous identification/updating when this system is used in operational settings.


Asunto(s)
Psicotrópicos/análisis , Espectrofotometría Infrarroja , Espectrometría Raman
3.
Chem Commun (Camb) ; 52(3): 493-6, 2016 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-26529417

RESUMEN

A set of seized "legal high" samples and pure novel psychoactive substances have been examined by surface-enhanced Raman spectroscopy using polymer-stabilized Ag nanoparticle (Poly-SERS) films. The films both quenched fluorescence in bulk samples and allowed identification of µg quantities of drugs collected with wet swabs from contaminated surfaces.


Asunto(s)
Nanopartículas del Metal/química , Metanfetamina/análogos & derivados , Polímeros/química , Plata/química , Drogas Ilícitas/análisis , Metanfetamina/análisis , Metanfetamina/química , Espectrometría Raman , Propiedades de Superficie
4.
Forensic Sci Int ; 216(1-3): e5-8, 2012 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-21873007

RESUMEN

It has been shown that a handheld Raman spectrometer can be used to determine hydrogen peroxide concentration in aqueous solutions in seconds. To allow quantitative analysis, the aqueous peroxide samples were mixed 50/50 (v/v) with a 4mol/dm(3) sodium perchlorate solution which acted as the internal standard. Standard calibration using relative peak heights of the strongest perchlorate (932cm(-1)) and peroxide bands (876cm(-1)) gave an average error of 1.43% for samples in the range 5-30% peroxide. PLS regression of the same data set gave an average error of 0.98%. In addition, the concentrations of the samples were estimated by searching spectra against a library of standard spectra prepared using the same range of peroxide concentrations at 5% increments and with the same perchlorate internal standard. It was found that the library searching method classified all the test samples correctly, matching either the spectra of the same concentration, if they were present, or matching to the closest concentration if an exact match was not possible. This method thus provides a very rapid technique to allow determination of hydrogen peroxide concentrations in the field, for example at suspected improvised explosives manufacturing sites, without complex calibration procedures.

5.
Anal Chim Acta ; 711: 1-6, 2012 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-22152788

RESUMEN

Raman spectra of a representative range of ß-ketophenethylamine (ß-KP), the rapidly growing family of cathinone-related "legal high" recreational drugs, have been recorded. These spectra showed characteristic changes that were associated with the pattern of substitution on the aromatic rings, for example, the compounds carrying substituents at the 4- position could be distinguished from 3,4-methylenedioxy "ecstasy" derivatives. They also showed small but detectable changes with differences in substitution on the ethylamine substituent. These features allowed the ß-KPs present in seized casework samples to be identified. The seized samples typically contained only small amounts of bulking agents, which meant that the band intensities of these components within averaged data were very small. In contrast, grid sampling normally gave at least some spectra which had a higher than average proportion of the bulking agent(s), which allowed them to also be identified. This study therefore demonstrates that Raman spectroscopy can be used both to provide a rapid, non-destructive technique for identification of this class of drugs in seized samples and to detect minor constituents, giving a composition profile which can be used for drugs intelligence work.


Asunto(s)
Alcaloides/química , Medicina Legal/métodos , Drogas Ilícitas/análisis , Cetonas/análisis , Fenetilaminas/análisis , Espectrometría Raman , Metanfetamina/análogos & derivados , Metanfetamina/análisis , Psicotrópicos/química , Estándares de Referencia
6.
J Forensic Sci ; 52(5): 1063-7, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17680788

RESUMEN

2,5,-Dimethoxy-4-bromoamphetamine (DOB) is of particular interest among the various "ecstasy" variants because there is an unusually long delay between consumption and effect, which dramatically increases the danger of accidental overdose in users. Screening for DOB in tablets is problematic because it is pharmacologically active at 0.2-3 mg, which is c. 50 times less than 3,4-methylenedioxy-N-methylamphetamine (MDMA) and makes it more difficult to detect in seized tablets using conventional spot tests. The normal Raman spectra of seized DOB tablets are dominated by the bands of the excipient with no evidence of the drug component. Here we report the first use of on-tablet surface-enhanced Raman spectroscopy (SERS) to enhance the signal from a low concentration drug. Raman studies (785-nm excitation) were carried on series of model DOB/lactose tablets (total mass c. 400 mg) containing between 1 mg and 15 microg of DOB and on seized DOB tablets. To generate surface-enhanced spectra, 5 microL of centrifuged silver colloid was dispensed onto the upper surface of the tablets, followed by 5 microL of 1.0 mol/dm(3) NaCl. The probe laser was directed onto the treated area and spectra accumulated for c. 20 sec (10 sec x 2). It was found that the enhancement of the DOB component in the model tablets containing 1 mg DOB/tablet and in the seized tablets tested was so large that their spectra were completely dominated by the vibrational bands of DOB with little or no contribution from the unenhanced lactose excipient. Indeed, the most intense DOB band was visible even in tablets containing just 15 microg of the drug. On-tablet surface-enhanced Raman spectroscopy is a simple method to distinguish between low dose DOB tablets and those with no active constituent. The fact that unique spectra are obtained allows identification of the drug while the lack of sample preparation and short signal accumulation times mean that the entire test can be carried out in <1 min.

7.
Appl Spectrosc ; 59(11): 1333-9, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16316510

RESUMEN

The ability of Raman spectroscopy and Fourier transform infrared (FT-IR) microscopy to discriminate between resins used for the manufacture of architectural finishes was examined in a study of 39 samples taken from a commercial resin library. Both Raman and FT-IR were able to discriminate between different types of resin and both split the samples into several groups (six for FT-IR, six for Raman), each of which gave similar, but not identical, spectra. In addition, three resins gave unique Raman spectra (four in FT-IR). However, approximately half the library comprised samples that were sufficiently similar that they fell into a single large group, whether classified using FT-IR or Raman, although the remaining samples fell into much smaller groups. Further sub-division of the FT-IR groups was not possible because the experimental uncertainty was of similar magnitude to the within-group variation. In contrast, Raman spectroscopy was able to further discriminate between resins that fell within the same groups because the differences in the relative band intensities of the resins, although small, were larger than the experimental uncertainty.


Asunto(s)
Arquitectura/métodos , Materiales de Construcción/análisis , Ciencias Forenses/métodos , Pintura/análisis , Resinas Sintéticas/análisis , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Espectrometría Raman/métodos
8.
Appl Spectrosc ; 59(11): 1340-6, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16316511

RESUMEN

White household paints are commonly encountered as evidence in the forensic laboratory but they often cannot be readily distinguished by color alone so Fourier transform infrared (FT-IR) microscopy is used since it can sometimes discriminate between paints prepared with different organic resins. Here we report the first comparative study of FT-IR and Raman spectroscopy for forensic analysis of white paint. Both techniques allowed the 51 white paint samples in the study to be classified by inspection as either belonging to distinct groups or as unique samples. FT-IR gave five groups and four unique samples; Raman gave seven groups and six unique samples. The basis for this discrimination was the type of resin and/or inorganic pigments/extenders present. Although this allowed approximately half of the white paints to be distinguished by inspection, the other half were all based on a similar resin and did not contain the distinctive modifiers/pigments and extenders that allowed the other samples to be identified. The experimental uncertainty in the relative band intensities measured using FT-IR was similar to the variation within this large group, so no further discrimination was possible. However, the variation in the Raman spectra was larger than the uncertainty, which allowed the large group to be divided into three subgroups and four distinct spectra, based on relative band intensities. The combination of increased discrimination and higher sample throughput means that the Raman method is superior to FT-IR for samples of this type.


Asunto(s)
Arquitectura/métodos , Color , Materiales de Construcción/análisis , Ciencias Forenses/métodos , Pintura/análisis , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Espectrometría Raman/métodos , Resinas Sintéticas/análisis
9.
Appl Spectrosc ; 59(1): 100-8, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15720744

RESUMEN

The potential of Raman spectroscopy to discriminate between architectural finishes (household paint) has been investigated using a test set of 51 ''lilac'' paints and three different excitation wavelengths. The spectra obtained with visible excitation typically displayed a series of intense Raman bands on a featureless fluorescence background but the spectra of all the paints studied had essentially identical bands. With 785 nm excitation, although the same bands that dominated the 514 nm spectra were still observed, other bands with comparable intensity also appeared. The two strongest scattering constituents were identified as a dioxazine dye, Violet 23 and beta-Cu(phthalocyanine). A scatter plot of the intensities of marker bands for these constituents (normalized to the strong rutile bands that were always present) showed that, despite the fact that the sample set spanned a wide range of rutile : dioxazine dye : phthalo- cyanine ratios, many of the samples had very similar ratios and could not be discriminated. However, all the samples (even those with similar relative proportions of the main constituents) could be discriminated on the basis of their minor constituents, either by manually measuring band intensities or through the creation and searching of spectral libraries.


Asunto(s)
Arquitectura/métodos , Ciencias Forenses/métodos , Pintura/análisis , Pintura/clasificación , Reconocimiento de Normas Patrones Automatizadas/métodos , Espectrometría Raman/métodos
10.
Analyst ; 128(11): 1331-5, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14700225

RESUMEN

Here we report the results of the largest study yet carried out on composition profiling of seized "ecstasy" tablets by Raman spectroscopy. Approximately 1500 tablets from different seizures in N. Ireland were analysed and even though practically all the tablets contained MDMA as active constituent, there were very significant differences in their Raman spectra, which were due to variations in both the nature and concentration of the excipients used and/or the degree of hydration of the MDMA. The ratios of the peak heights of the prominent drug bands at 810 cm(-1) and 716 cm(-1) (which vary with hydration state of the drug), and the drug band at 810 cm(-1) against the largest clearly discernible excipient band in the spectrum were measured for all the samples. It was found that there was sufficient variation in composition in the general sample population to make any matches between batches of tablets taken from different seizures significant, rather than the result of random chance. Despite the large number of different batches of tablets examined in this study, only two examples of indistinguishable sets of tablets were found and in only one of these had the two batches of tablets been seized at different times. Finally, the fact that there are many examples of batches of tablets (particularly in different batches taken from single seizures) in which the differences between each set are sufficiently small that they appear to arise only from random variations within a standard manufacturing method implies that, with more extensive data, it may be possible to recognize the "signature" of tablets prepared by major manufacturers.


Asunto(s)
Control de Medicamentos y Narcóticos , N-Metil-3,4-metilenodioxianfetamina/análisis , Estudios de Factibilidad , Espectrometría Raman
12.
Haemostasis ; 6(3): 157-62, 1977.
Artículo en Inglés | MEDLINE | ID: mdl-885378

RESUMEN

Plasma from a patient factor VIII inhibitor was mixed at several low concentrations with fresh normal plasma. The factor VIII deficient plasmas obtained after a short incubation period were used as substrate plasmas in the normal one-stage factor VIII assay method. Results obtained using 0.5-1% of the inhibitor plasma in normal plasma compared favourably with those obtained using normal haemophilia A factor VIII deficient plasma provided that tests were carried out without delay. A single plasma exchange of this patient provided enough antibody to prepare more than 500 litres of factor VIII deficient plasma by simple mixing with fresh normal plasma.


Asunto(s)
Factor VIII , Plasma , Adulto , Anticuerpos , Pruebas de Coagulación Sanguínea , Hemofilia A/diagnóstico , Humanos , Masculino , Tromboplastina/análisis , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA