Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Psychol Psychother ; 26(6): 673-683, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31343093

RESUMEN

This paper sought to assess whether cognitive analytic therapy (CAT) was effective with a male patient meeting diagnostic criteria for hoarding disorder (HD) who had been nonresponsive to two previous courses of cognitive behaviour therapy. An adjudicated hermeneutic single-case efficacy design (HSCED) evaluation was undertaken. A rich case record (i.e., a summary document containing the case details, formulations, and detailed qualitative and quantitative outcomes) was created. The rich case record was then debated by affirmative (N = 3) and sceptic (N = 3) research teams. Expert judges (N = 3) reviewed the debate and then delivered a final verdict as to whether treatment had worked. Judges unanimously returned a verdict in favour of the sceptic position, concluding that CAT had not enabled change. Lack of change on the primary nomothetic hoarding outcome measure was particularly influential in the final judgement. In this case of HD, CAT was therefore not effective as an intervention. More research is needed before any definitive conclusions can be drawn however as to the wider utility of CAT with HD. Methodological limitations are outlined, alongside considerations for future research.


Asunto(s)
Terapia Cognitivo-Conductual/métodos , Trastorno de Acumulación/terapia , Hermenéutica , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Reino Unido
2.
Int J Pediatr Otorhinolaryngol ; 83: 193-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26968076

RESUMEN

OBJECTIVES: The aim of this study was to investigate whether experienced paediatric cochlear implant users could show benefits to speech perception outcomes from the introduction of noise reduction and automated scene classification technologies as implemented in the Nucleus(®) 6 sound processor. Previous research with adult cochlear implant users had shown significant improvements in speech intelligibility for listening in noisy conditions and good user acceptance for upgrading to the Nucleus 6 processor. In adults, these improvements for listening in noise were primarily attributed to the use of a range of new input processing technologies including noise reduction, as well as introduction of automatic scene classification technology. METHODS: Experienced paediatric cochlear implant users (n=25) were recruited from four clinics located in three countries. Research participants were evaluated on three occasions, an initial session using their Nucleus 5 sound processor; a second session in which participants used the Nucleus 6 processor programmed with the same technologies as were used in their Nucleus 5 sound processor; and a final session in which participants used the Nucleus 6 processor programmed with the default technologies including automatic scene classification (SCAN) which automatically selects the microphone directionality, noise reduction (SNR-NR), and wind noise reduction (WNR) technologies. Prior to both the second and third evaluations, research participants had approximately two weeks take-home experience with the new system. Speech perception performances on monosyllabic word tests presented in quiet and in noise, and a sentence test presented in noise, were compared across the three processor conditions. Acceptance of the Nucleus 6 default settings was assessed in a final session. RESULTS: No group mean difference in performance was found for monosyllabic words in quiet. A significant improvement in speech perception was found for both monosyllabic words and sentences in noise with the default Nucleus 6 program condition as compared with the Nucleus 5 condition. No acceptance issues were noted for any of the children. CONCLUSIONS: Experienced paediatric cochlear implant users showed a significant improvement in speech perception in listening in noise when upgraded to the Nucleus 6 sound processor primarily due to the introduction of a noise reduction technology, and all children accepted the default program. These findings suggest that school-aged children may benefit from upgrading to the Nucleus 6 sound processor using the default program.


Asunto(s)
Implantación Coclear/instrumentación , Implantes Cocleares , Percepción del Habla/fisiología , Niño , Femenino , Humanos , Lenguaje , Masculino , Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...