Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neuroradiology ; 56(5): 397-403, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24619135

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the safety and efficacy of the pREset stent retriever in a real-world clinical setting. METHODS: Patients treated with pREset were selected from a prospectively maintained single-center database. A TICI score ≥2b after ≤3 passes was regarded as successful recanalization. All device-related complications and their clinical significance were reported. Parenchymal hematomas (PH) were classified according to ECASS, adding focal and diffuse subarachnoid hemorrhage (SAH) as categories. A 90-day mRS of 0-2 was defined as favorable outcome. In addition, we separately analyzed patients treated with >3 pREset passes and patients receiving other rescue maneuvers. RESULTS: We included 271 patients. Successful recanalization was achieved in 76.4 %. Device-related complications occurred in 9.2 % of which 2.2 % were clinically significant. PH I, PH II, focal SAH, and diffuse SAH was observed in 5.2, 4.8, 12.2, and 2.2 %, respectively. A total of 39.5 % of patients had favorable clinical outcome. Considering treatments with >3 pREset passes or other rescue procedures, an additional 8.5 and 9.3 % of target vessels were recanalized. The chance of favorable clinical outcome decreased significantly with any kind of rescue therapy. In addition, the rate of PH I was significantly higher in patients treated with >3 pREset passes, whereas all other types of hemorrhage showed no difference. CONCLUSION: In terms of safety and effectiveness, pREset performed comparably to other stent retriever devices. To avoid futile recanalization and potential additional harm, escalation of therapy beyond three thrombectomy passes should only be performed after careful individual consideration of each case.


Asunto(s)
Isquemia Encefálica/cirugía , Stents , Accidente Cerebrovascular/cirugía , Trombectomía/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Adulto Joven
2.
Neurosurgery ; 70(1): 91-101; discussion 101, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21778921

RESUMEN

BACKGROUND: Balloon dilatation and deployment of a self-expanding stent is a safe treatment for intracranial atherosclerotic stenoses. The significant recurrence rate might be related to the high radial force of the Wingspan stent. OBJECTIVE: To evaluate the procedural safety and stenosis recurrence rate by the use of a stent with reduced radial force (Enterprise). METHODS: Two hundred nine atherosclerotic stenoses (189 patients) were treated (median age, 68 years; 132 male) in a single center. Lesion locations included internal carotid artery (n = 27), middle cerebral artery (n = 62), vertebral artery (n = 64), basilar artery (n = 55), and posterior cerebral artery (n = 1). Pre- and postmedication included acetylsalicylic acid and Clopidogrel for at least 12 months. Preprocedural and follow-up examinations included magnetic resonance imaging (MRI), neurological assessment, and digital subtraction angiography (6, 12, 26, and 52 weeks). Data registry included age, sex, normal vessel diameter, degree of stenosis, residual stenosis after stent, minimal in-stent diameter, and occurrence of ischemic symptoms during follow-up. RESULTS: Median pre- and postprocedural stenosis rate was 65.4 ± 1% vs 25.1 ± 1%. Technical success rate was 100%. Major procedural complications occurred in 16 patients (8.1%). Combined neurological morbidity and mortality rate at 30 days was 2 patients (0.9%). In 174 stenoses (83%) angiographic follow-up was obtained (mean, 10.2 months). A restenosis (>50%) was observed in 43 (24.7%) cases after 4.2 months (mean) with 4 (9.3%) symptomatic lesions. Incidence of recurrent ischemia related to the stented artery was 2.2% during 10.2 months of mean follow-up. CONCLUSION: Undersized balloon angioplasty and deployment of an Enterprise stent is safe and effective for intracranial stenoses. Follow-up results were equal to or better than those reported for bare-metal balloon-expandable or self-expanding stents and yielded excellent protection from recurrent ischemia.


Asunto(s)
Angioplastia de Balón/instrumentación , Angioplastia de Balón/métodos , Arteria Carótida Interna/cirugía , Arteriosclerosis Intracraneal/cirugía , Stents , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital/métodos , Arteria Carótida Interna/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Arteriosclerosis Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Curva ROC , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...