Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Int J Comput Assist Radiol Surg ; 19(3): 591-599, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37523011

RESUMEN

PURPOSE: The aim of the study was to assess the deviation between clinical implant axes (CIA) determined by a surgeon during preoperative planning and reconstructed tooth axes (RTA) of missing teeth which were automatically computed by a previously introduced anatomical SSM. METHODS: For this purpose all available planning datasets of single-implant cases of our clinic, which were planned with coDiagnostix Version 9.9 between 2018 and 2021, were collected for retrospective investigation. Informed consent was obtained. First, the intraoral scans of implant patients were annotated and subsequently analyzed using the SSM. The RTA, computed by the SSM, was then projected into the preoperative planning dataset. The amount and direction of spatial deviation between RTA and CIA were then measured. RESULTS: Thirty-five patients were implemented. The mean distance between the occlusal entry point of anterior and posterior implants and the RTA was 0.99 mm ± 0.78 mm and 1.19 mm ± 0.55, respectively. The mean angular deviation between the CIA of anterior and posterior implants and the RTA was 12.4° ± 3.85° and 5.27° ± 2.97° respectively. The deviations in anterior implant cases were systematic and could be corrected by computing a modified RTA (mRTA) with decreased deviations (0.99 mm ± 0.84 and 4.62° ± 1.95°). The safety distances of implants set along the (m)RTA to neighboring teeth were maintained in 30 of 35 cases. CONCLUSION: The RTA estimated by the SSM revealed to be a viable implant axis for most of the posterior implant cases. As there are natural differences between the anatomical tooth axis and a desirable implant axis, modifications were necessary to correct the deviations which occurred in anterior implant cases. However, the presented approach is not applicable for clinical use and always requires manual optimization by the planning surgeon.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Diente , Humanos , Tomografía Computarizada de Haz Cónico , Estudios Retrospectivos , Prótesis e Implantes , Diseño Asistido por Computadora , Imagenología Tridimensional
2.
Clin Oral Implants Res ; 34 Suppl 26: 86-103, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37750526

RESUMEN

OBJECTIVE: The objectives of the study were to assess the survival, failure, and technical complication rates of implant-supported fixed dental prosthesis (iFDPs) with pontic or splinted crown (iSp C) designs in the posterior area and compare the influence of prosthetic materials and prosthetic design on the outcomes. METHODS: Electronic and manual searches were performed to identify randomized-, prospective-, and retrospective clinical trials with follow-up time of ≥12 months, evaluating the clinical outcomes of posterior iFDPs with pontic or iSp Cs. Survival and complication rates were analyzed using robust Poisson's regression models. RESULTS: Thirty-two studies reporting on 42 study arms were included in the present systematic review. The meta-analysis of the included studies indicated estimated 3-year survival rates of 98.3% (95%CI: 95.6-99.3%) for porcelain-fused-to-metal (PFM) iFDPs, 97.5% (95%CI: 95.5-98.7%) for veneered zirconia (Zr) iFDPs with pontic, 98.9% (95%CI: 96.8-99.6%) for monolithic or micro-veneered zirconia iFDPs with pontic, and 97.0% (95%CI: 84.8-99.9%) for lithium disilicate iFDPs with pontics. The survival rates for different material combination showed no statistically significant differences. Veneered restorations, overall, showed significantly (p < .01) higher ceramic fracture and chipping rates compared with monolithic restorations. Furthermore, there was no significant difference in survival rates (98.3% [95%CI: 95.6-99.3%] vs. 99.1% [95%CI: 97.6-99.7%]) and overall complication rates between PFM iFDPs with pontic and PFM iSp Cs. CONCLUSIONS: Based on the data identified by this systematic review, PFM, veneered Zr, and monolithic Zr iFDPs with pontic and iSp Cs showed similarly high short-term survival rates in the posterior area. Veneered restorations exhibit ceramic chipping more often than monolithic restorations, with the highest fracture rate reported for veneered Zr iFDPs.


Asunto(s)
Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Estudios Prospectivos , Estudios Retrospectivos , Porcelana Dental , Cerámica , Circonio , Coronas , Prótesis Dental de Soporte Implantado
3.
Clin Oral Investig ; 27(10): 5875-5886, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37581766

RESUMEN

OBJECTIVES: To assess clinical, radiological and esthetic outcomes of restorations supported by root-analogue implants (RAIs) or roots of severely damaged teeth after forced orthodontic extrusion (FOE). MATERIALS AND METHODS: Clinical data regarding milled one-piece (titanium/zirconia roots and zirconia abutments) RAIs (REPLICATE™ System) and FOE were recorded and retrospectively evaluated for 40 patients by two investigators. Strict inclusion and exclusion criteria were applied. Functional and esthetic outcomes were assessed for n = 20 pre-molars and n = 20 anterior teeth via comparison of radiographic and digital images applying the novel Functional Implant Prosthodontic Score (FIPS). Krippendorff's alpha coefficient was calculated to assess inter-rater reliability. Mann-Whitney-U-Test was used to compare the assessed parameters. Level of significance was set to p < 0.05. RESULTS: After a mean observation period of 18.4 ± 5.7 months for restorations supported by RAIs and 43.9 ± 16.4 months for restorations after FOE, mean FIPS scores were 9.2/8.8 ± 1.1/1.2 (RAIs) and 7.4/7.7 ± 1.3/1.5 (FOE), respectively. Krippendorff's alpha coefficients did not reveal unacceptable inter-rater reliabilities regarding the investigators and applicability of FIPS. Significant differences were documented when comparing restorations after FOE or supported by RAIs regarding bone loss (p < 0.01), presence of papillae (p < 0.05) and quality and quantity of mucosa (p < 0.02) in favor of FOE. CONCLUSIONS: Within the main limitations of sample size and the retrospective study design, both concepts seem to provide clinically acceptable results. CLINICAL RELEVANCE: Bone- and tissue-preserving characteristics regarding the concept of FOE are promising. It could be applicable for socket preservation and subsequent conventional implant placements in an adapted workflow.

4.
J Dent ; 132: 104482, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36931618

RESUMEN

OBJECTIVES: This in vitro study aimed to assess the influence of the planning software and design of the surgical template on both trueness and precision of static computer assisted implant surgery (sCAIS) performed using guides fabricated using material extrusion (ME). METHODS: Three-dimensional radiographic and surface scans of a typodont were aligned using two planning software (coDiagnostiX, CDX; ImplantStudio, IST) to virtually position the two adjacent oral implants. Thereafter, surgical guides were fabricated with either an original (O) or modified (M) design with reduced occlusal support and were sterilized. Forty surgical guides were used to install 80 implants equally distributed amongst four groups: CDX-O, CDX-M, IST-O, and IST-M. Thereafter, the scan bodies were adapted to the implants and digitized. Finally, inspection software was used to assess discrepancies between the planned and final positions at the implant shoulder and main axis level. Multilevel mixed-effects generalised linear models were used for statistical analyses (p = 0.05). RESULTS: In terms of trueness, the largest average vertical deviations (0.29 ± 0.07 mm) were be assessed for CDX-M. Overall, vertical errors were dependant on the design (O < M; p ≤ 0.001). Furthermore, in horizontal direction, the largest mean discrepancy was 0.32 ± 0.09 mm (IST-O) and 0.31 ± 0.13 mm (CDX-M). CDX-O was superior compared to IST-O (p = 0.003) regarding horizontal trueness. The average deviations regarding the main implant axis ranged between 1.36 ± 0.41° (CDX-O) and 2.63 ± 0.87° (CDX-M). In terms of precision, mean standard deviation intervals of ≤ 0.12 mm (IST-O and -M) and ≤ 1.09° (CDX-M) were calculated. CONCLUSIONS: Implant installation with clinically acceptable deviations is possible with ME surgical guides. Both evaluated variables affected trueness and precision with negligible differences. CLINICAL SIGNIFICANCE: The planning system and design influenced the accuracy of implant installation using ME-based surgical guides. Nevertheless, discrepancies were ≤ 0.32 mm and ≤ 2.63°, which may be considered within the range of clinical acceptance. ME should be further investigated as an alternative to the more expensive and time-consuming 3D printing technologies.


Asunto(s)
Implantes Dentales , Implantación Dental Endoósea , Diseño Asistido por Computadora , Imagenología Tridimensional , Tomografía Computarizada de Haz Cónico , Programas Informáticos , Computadores
5.
J Funct Biomater ; 14(1)2023 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-36662092

RESUMEN

The objective was to investigate the clinical and radiological outcome of one-piece zirconia oral implants to support three-unit fixed dental prostheses (FDP) after three years in function. Twenty-seven patients were treated with a total of 54 implants in a one-stage surgery and immediate provisionalization. Standardized radiographs were taken at implant placement, after one year and after three years, to evaluate peri-implant bone loss. Soft-tissue parameters were also assessed. Linear mixed regression models as well as Wilcoxon Signed Rank tests were used for analyzing differences between groups and time points (p < 0.05). At the three-year evaluation, one implant was lost, resulting in a cumulative survival rate of 98.1%. The mean marginal bone loss amounted to 2.16 mm. An implant success grade I of 52% (bone loss of ≤2 mm) and success grade II of 61% (bone loss of ≤3 mm) were achieved. None of the evaluated baseline parameters affected bone loss. The survival rate of the zirconia implants was comparable to market-available titanium implants. However, an increased marginal bone loss was observed with a high peri-implantitis incidence and a resulting low implant success rate.

6.
Int J Comput Assist Radiol Surg ; 17(10): 1957-1968, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35902422

RESUMEN

PURPOSE: Modern virtual implant planning is a time-consuming procedure, requiring a careful assessment of prosthetic and anatomical factors within a three-dimensional dataset. In order to facilitate the planning process and provide additional information, this study examines a statistical shape model (SSM) to compute the course of dental roots based on a surface scan. MATERIAL AND METHODS: Plaster models of orthognathic patients were scanned and superimposed with three-dimensional data of a cone-beam computer tomography (CBCT). Based on the open-source software "R", including the packages Morpho, mesheR, Rvcg and RvtkStatismo, an SSM was generated to estimate the tooth axes. The accuracy of the calculated tooth axes was determined using a leave-one-out cross-validation. The deviation of tooth axis prediction in terms of angle or horizontal shift is described with mean and standard deviation. The planning dataset of an implant surgery patient was additionally analyzed using the SSM. RESULTS: 71 datasets were included in this study. The mean angle between the estimated tooth-axis and the actual tooth-axis was 7.5 ± 4.3° in the upper jaw and 6.7 ± 3.8° in the lower jaw. The horizontal deviation between the tooth axis and estimated axis was 1.3 ± 0.8 mm close to the cementoenamel junction, and 0.7 ± 0.5 mm in the apical third of the root. Results for models with one missing tooth did not differ significantly. In the clinical dataset, the SSM could give a reasonable aid for implant positioning. CONCLUSIONS: With the presented SSM, the approximate course of dental roots can be predicted based on a surface scan. There was no difference in predicting the tooth axis of existent or missing teeth. In clinical context, the estimation of tooth axes of missing teeth could serve as a reference for implant positioning. However, a higher number of training data must be achieved to obtain increasing accuracy.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico/métodos , Estudios de Factibilidad , Humanos , Imagenología Tridimensional , Mandíbula , Maxilar , Cirugía Asistida por Computador/métodos
7.
J Clin Med ; 11(9)2022 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-35566508

RESUMEN

Adequate soft-tissue dimensions have been shown to be crucial for the long-term success of dental implants. To date, there is evidence that placement of dental implants should only be conducted in an area covered with attached gingiva. Modern implant planning software does not visualize soft-tissue dimensions. This study aims to calculate the course of the mucogingival borderline (MG-BL) using statistical shape models (SSM). Visualization of the MG-BL allows the practitioner to consider the soft tissue supply during implant planning. To deploy an SSM of the MG-BL, healthy individuals were examined and the intra-oral anatomy was captured using an intra-oral scanner (IOS). The empirical anatomical data was superimposed and analyzed by principal component analysis. Using a Leave-One-Out Cross Validation (LOOCV), the prediction of the SSM was compared with the original anatomy extracted from IOS. The median error for MG-BL reconstruction was 1.06 mm (0.49-2.15 mm) and 0.81 mm (0.38-1.54 mm) for the maxilla and mandible, respectively. While this method forgoes any technical work or additional patient examination, it represents an effective and digital method for the depiction of soft-tissue dimensions. To achieve clinical applicability, a higher number of datasets has to be implemented in the SSM.

8.
Materials (Basel) ; 15(3)2022 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-35161032

RESUMEN

The purpose of the study was to compare conventional to digital workflows of occlusal splint production regarding time efficiency, overall fit, and wear. Fifteen Michigan splints were fabricated with a conventional and digital method. The duration for the dentist's and the dental technician's workload was recorded. Subsequently, the overall fit was examined with a four-level score (1-4). Paired t-tests were used to compare the time results for the conventional and digital workflows and the sign test to compare the overall fit. The mean time (16 min 58 s) for computerized optical impressions was longer than for conventional impressions (6 min 59 s; p = 0.0001). However, the dental technician needed significantly less mean time for the digital splint production (47 min 52 s) than for the conventional (163 min 32 s; p = 0.001). The overall fit of the digitally-fabricated splints was significantly better compared to the conventionally-fabricated splints (p = 0.002). There was no impact of the different materials used in the conventional and digital workflow on the wear (p = 0.26). The results suggest that the digital workflow for the production of occlusal splints is more time efficient and leads to a better fit than the conventional workflow.

9.
Int J Comput Dent ; 25(4): 349-359, 2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-35072424

RESUMEN

PURPOSE: Creating wax-ups of missing teeth for backward planning in implant surgery is a complex and time-consuming process. To facilitate implant-planning procedures, the automatic generation of a virtual wax-up would be useful. In the present study, the reconstruction of missing teeth in partially edentulous patients was performed automatically using newly developed software. The accuracy was investigated in order to test its clinical applicability. MATERIALS AND METHODS: This study presents a new method for creating an automatic virtual wax-up, which could serve as a basic tool in modern implant-planning procedures. First, a statistical shape model (SSM) based on 76 maxillary and mandibular arch scans from dentally healthy individuals was generated. Then, artificially generated tooth gaps were reconstructed. The accuracy of the workflow was evaluated on a separate testing sample of 10 individuals with artificially created tooth gaps given as a median deviation, in millimeters. Scans of three clinical cases with partial edentulism were equally reconstructed using the SSM and compared with the final prosthodontic work. RESULTS: The reconstruction of the artificial tooth gaps could be performed with the following median reconstruction accuracy: gap 21 with 0.15 mm; gap 27 with 0.20 mm; gap 34 with 0.22 mm: gap 36 with 0.22 mm; gaps 12 to 22 with 0.22 mm; gaps 34 to 36 with 0.22 mm. A scenario for an almost edentulous mandible with all teeth missing except teeth 33 and 43 could be reconstructed with a median reconstruction accuracy of 0.37 mm. The median tooth gap deviation of the SSM-based reconstruction in clinical cases differed from the final inserted prosthodontic teeth by 0.49 to 0.86 mm in median. CONCLUSION: A first feasibility of creating virtual wax-ups using an SSM could be shown. Artificially generated tooth gaps could be reconstructed close to the original with the proposed workflow. In the clinical cases, the SSM proposes an anatomical reconstruction, which does not yet consider prosthodontic aspects. To obtain clinical use, contact with antagonist teeth must be considered and more training data must be implemented. However, the presented method offers a fast and viable way for the approximate placement of missing crowns. This could be used in a digital planning workflow when implant position must be determined. (Int J Comput Dent 2022;25(4):349-0; doi: 10.3290/j.ijcd.b2599407).


Asunto(s)
Implantes Dentales , Boca Edéntula , Humanos , Prostodoncia , Modelos Estadísticos , Coronas
10.
J Prosthodont Res ; 66(2): 318-325, 2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-34456211

RESUMEN

PURPOSE: The accuracy of intraoral and model scanners has been widely investigated with heterogeneous results, but the impact of the applied diversity of measurement methods on the outcomes remains unknown. This study aimed to evaluate the influence of methodological factors on the measurement result when comparing full-arch scans. METHODS: The evaluation referred to a 5M model to analyze whether accuracy measurements are affected by (1) the reference geometry, (2) mesh density of the standard tessellation language (STL) datasets, (3) operator, (4) inspection software, and (5) alignment procedure. STL datasets of full-arch reference models were measured with 29 different combinations of these factors. For each combination, 10 repeated measurements of the intermolar width were performed. Trueness was statistically analyzed with one-way ANOVA and T-tests, repeatability with Levene tests, and reproducibility with interclass correlation coefficients. RESULTS: Measurement method variations affected the intermolar width by up to 186 µm. The alignment algorithm had a significant effect on the measurement outcome (p = 0.001). Likewise, reference geometry influenced trueness and repeatability significantly (p = 0.001), whereas mesh density affected the repeatability only in some cases. The operator had no impact on the measurement result. The inspection software affected the repeatability but not the trueness. CONCLUSION: The factors reference geometry and alignment algorithm highly affected the measurement outcome, while the operator, inspection software, and mesh density showed no impact on the trueness of the outcome. Cylindrical reference geometries showed fewer differences than bar-shaped ones and best-fit alignments fewer variations than alignments based on boundary parameters.


Asunto(s)
Técnica de Impresión Dental , Modelos Dentales , Diseño Asistido por Computadora , Imagenología Tridimensional , Reproducibilidad de los Resultados
11.
Clin Oral Investig ; 26(1): 849-861, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34241707

RESUMEN

OBJECTIVES: To evaluate long-term survival and success rates of conventionally cemented partial-coverage crowns (PCCs) manufactured from high noble metal alloys (hn). MATERIAL AND METHODS: Restoration-, periodontal- and tooth-related criteria on patients, restored with a single or multiple conventionally cemented hnPCCs in a private dental office were collected from existing patient records. With regard to semi-annual follow-ups, data of the most recent clinical evaluations were considered. Kaplan-Meier and log-rank tests were used for statistical analyses. Level of significance was set at p ≤ .05. RESULTS: Between 09/1983 and 09/2009, 1325 hnPCCs were conventionally cemented on 1325 teeth in 266 patients (mean age: 44.5 ± 10.7 years). Due to various reasons, 81 hnPCCs showed complications, documenting a success rate of 93.9% after a mean observation period of 18.8 ± 5.7 years. Of these, additional 14 restorations were counted as survival, resulting in a survival rate of 94.9%. Most frequent complications were periodontal issues (n = 29, 35.8%). Significantly higher success rates were documented for hnPCCs of patients aged between 37 and 51 years (p = .012). CONCLUSION: Partial-coverage crowns from high noble metal alloys showed excellent survival and success rates after a mean observation period of 18.8 ± 5.7 years. Higher patient age was one of the risk factors. CLINICAL RELEVANCE: According to the results of this study, hnPCCs still represent an excellent therapeutic option-even in modern dentistry.


Asunto(s)
Porcelana Dental , Aleaciones de Cerámica y Metal , Adulto , Aleaciones , Coronas , Fracaso de la Restauración Dental , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
12.
Materials (Basel) ; 14(9)2021 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-33922688

RESUMEN

A novel ceria-stabilized zirconia-alumina-aluminate composite (Ce-TZP-comp) that is not prone to aging presents a potential alternative to yttrium-stabilized zirconia for ceramic oral implants. The objective of this study was to evaluate the long-term stability of a one-piece narrow-diameter implant made of Ce-TZP-comp. Implant prototypes with a narrow (3.4 mm) and regular (4.0 mm) diameter were embedded according to ISO 14801, and subgroups (n = 8) were subsequently exposed to dynamic loading (107 cycles, 98N) and/or hydrothermal treatment (aging, 85 °C). Loading/aging was only applied as a combined protocol for the 4.0 mm diameter implants. One subgroup of each diameter remained untreated. One sample was cross-sectioned from each subgroup and evaluated with a scanning electron microscope for phase-transformation of the lattice. Finally, the remaining samples were loaded to fracture. A multivariate linear regression model was applied for statistical analyses (significance at p < 0.05). All samples withstood the different loading/aging protocols and no transformation propagation was observed. The narrow diameter implants showed the lowest fracture load after combined loading/aging (628 ± 56 N; p < 0.01), whereas all other subgroups exhibited no significantly reduced fracture resistance (between 762 ± 62 and 806 ± 73 N; p > 0.05). Therefore, fracture load values of Ce-TZP-comp implants suggest a reliable intraoral clinical application in the anterior jaw regions.

13.
Dent Mater ; 37(5): 928-938, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33722400

RESUMEN

OBJECTIVE: To investigate the tensile and flexural strength of poured, subtractive, and additive manufactured denture base methacrylates bonded to soft and hard relining materials after hydrothermal cycling and microwave irradiation. METHODS: This study included a conventional (CB), subtractive (SB), and additive (AB) base material as well as a soft (SCR) and hard (HCR) chairside and one hard laboratory-side (HLR) relining material. Reference bodies of the base materials and bonded specimens to the relining materials were produced with a rectangular cross-section. The specimens were either pre-treated by water storage (50 h, 37 °C), hydrothermal cycling (5000 cycles, 5 °C and 55 °C, 30 s each), or microwave irradiation (6 cycles, 640 W, 3 min, wet). A tensile and four-point bending test were performed for a total of 504 specimens. Data were analysed using multivariate analysis of variance (MANOVA) with post-hoc Tukey tests (α = 0.05). RESULTS: In comparison with the other reference groups SB showed marginally higher tensile and flexural strength (p < 0.047). Bond strength to SCR was affected neither by the base material nor by the pre-treatment (p > 0.085). HCR demonstrated twice the bond strength to AB compared with SB and CB (p ≤ 0.001). HLR showed the highest bond strength to CB (p ≤ 0.001). There was no difference between the specimens after hydrothermally cycling and microwave irradiation (p > 0.318). SIGNIFICANCE: The bond strength of hard relining materials to subtractive and additive manufactured denture bases differ compared with conventional pouring.


Asunto(s)
Recubrimiento Dental Adhesivo , Alineadores Dentales , Resinas Acrílicas , Bases para Dentadura , Ensayo de Materiales , Propiedades de Superficie , Resistencia a la Tracción
14.
Materials (Basel) ; 14(2)2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33430271

RESUMEN

Computer-aided design and computer-aided manufacturing (CAD-CAM) enable subtractive or additive fabrication of temporary fixed dental prostheses (FDPs). The present in-vitro study aimed to compare the fracture resistance of both milled and additive manufactured three-unit FDPs and bar-shaped, ISO-conform specimens. Polymethylmethacrylate was used for subtractive manufacturing and a light-curing resin for additive manufacturing. Three (bars) and four (FDPs) different printing orientations were evaluated. All bars (n = 32) were subjected to a three-point bending test after 24 h of water storage. Half of the 80 FDPs were dynamically loaded (250,000 cycles, 98 N) with simultaneous hydrothermal cycling. Non-aged (n = 40) and surviving FDPs (n = 11) were subjected to static loading until fracture. Regarding the bar-shaped specimens, the milled group showed the highest flexural strength (114 ± 10 MPa, p = 0.001), followed by the vertically printed group (97 ± 10 MPa, p < 0.007). Subtractive manufactured FDPs revealed the highest fracture strength (1060 ± 89 N) with all specimens surviving dynamic loading. During artificial aging, 29 of 32 printed specimens failed. The present findings indicate that both printing orientation and aging affect the strength of additive manufactured specimens. The used resin and settings cannot be recommended for additive manufacturing of long-term temporary three-unit FDPs.

15.
Clin Oral Implants Res ; 32(4): 470-486, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33501694

RESUMEN

OBJECTIVE: To assess clinical and patient-reported outcomes of implant-prosthetic rehabilitations in patients with a history of head-neck cancer (HNC), treated with tumor resection without (TR) or with adjuvant radiotherapy (TR/RT). A healthy cohort rehabilitated with the same reconstructive protocols served as control group (C). MATERIALS AND METHODS: A total of 28 women and 29 men were considered in the present retrospective study. Participants received 322 implants, finally supporting 79 prosthetic reconstructions. Primary outcome was the assessment of implant and prosthetic survival rates. Furthermore peri-implant soft tissue parameters (attached peri-implant mucosa, AM; modified bleeding and plaque indices, mBI/mPI; probing depth, PD) and prosthetic technical complications were documented. Patient-reported outcome measures (PROMs) by means of visual analog scales (VAS) and the Oral Health Impact Profile German 14 form (OHIP G14) were collected. For statistical purposes Chi-square and Mann-Whitney-U-Test were adapted. RESULTS: After a mean follow-up of 81.2 ± 50.3 months, implant survival rate was 98.1% (HNC-TR), 98.2% (HNC-TR/RT) and 100.0% (C), respectively (four implants failed in the HNC groups). HNC-TR/RT showed significant higher mPI and mBI compared to C. Within HNC-TR/RT, vestibuloplasty significantly reduced mBI and PD values. No failures occurred at the prosthetic level. Overall, higher VAS scores were reported for bar- compared with Locator-retained prostheses. Furthermore, increased OHIP G14 values resulted for HNC-TR/RT. CONCLUSIONS: High survival rates on implant and prosthetic level were observed. The use of soft tissue grafts resulted in stabilization of the peri-implant mucosa in irradiated patients. In terms of retention and chewing ability, participants preferred bars over Locator attachments.


Asunto(s)
Implantes Dentales , Neoplasias de Cabeza y Cuello , Arcada Edéntula , Prótesis Dental de Soporte Implantado , Retención de Dentadura , Prótesis de Recubrimiento , Femenino , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Masculino , Estudios Retrospectivos
16.
J Mech Behav Biomed Mater ; 114: 104179, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33189599

RESUMEN

Occlusal devices to reduce symptoms of bruxism and temperomandibular disorders can nowadays be manufactured in a digital workflow but studies comparing the accuracy of those occlusal devices are still limited. Therefore, the aim of this investigation was to investigate the accuracy of injection molding compared with four computer-aided design (CAD) and computer-aided manufacturing (CAM) techniques for the manufacturing of occlusal devices. In addition, the number of contact points and retention were evaluated to assess clinical relevance. A conventional workflow consisting of alginate impression, wax-up, and injection molding (IM) and digital workflows including intraoral scanning, digital design, and subtractive manufacturing (SM) or additive manufacturing by using stereolithography (SLA), digital light processing (DLP), and material jetting (Polyjet) were investigated. Sixteen splints were fabricated with each method. The intaglio surfaces of the splints were laser scanned and superimposed with the reference data sets to analyze the surface deviations. In addition, the number of contact points after repositioning the splints on the reference model was evaluated with occlusal foil. Finally, the retention was measured in a tensile test. One-way ANOVA with post hoc Tukey tests were used for statistical analyses (α = .05). IM and SM splints demonstrated the highest manufacturing accuracy without significant differences to each other (P > .985). Additive manufactured splints revealed greater deviations with equal results for SLA and Polyjet (P > .949) and significantly higher deviations for DLP compared to all other groups (P < .002). Comparable retention force was measured for IM, SM, and SLA (P > .923), whereas Polyjet splints showed the greatest variability. IM and SM splints presented the most contact points (P = .505). Additive manufactured splints demonstrated fewer contacts without significant difference to each other (P > .116). It can be concluded, that there is no difference in manufacturing accuracy, retention, and number of contacts between IM and SM splints. AM splints demonstrated higher, however, clinically acceptable deviations.


Asunto(s)
Bruxismo , Ferulas Oclusales , Diseño Asistido por Computadora , Diseño de Prótesis Dental , Humanos , Férulas (Fijadores) , Flujo de Trabajo
17.
Dent Mater ; 37(3): 432-442, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33288324

RESUMEN

OBJECTIVES: To investigate the wear resistance of polymers for injection molding, subtractive and additive manufacturing of occlusal devices in comparison with enamel antagonist wear and material properties (i.e., hardness, flexural strength, and flexural modulus). METHODS: Injection molding was compared with milling and the additive technologies stereolithography, low force stereolithography, and digital light processing. For each material, eight specimens were produced for wear measurements. Extracted human premolars served as indenters. All samples were subjected to two series of a 2-body wear test consisting of 200,000 circular loading cycles with an applied load of 1) 20 N and 2) 50 N in a thermocycling environment (5/55 °C, 30 s, 3860 cycles, H2O). Wear resistance was characterized by means of maximum depth and volume of the resulting traces. In addition, enamel wear of the indenters and Vickers hardness, flexural strength, and flexural modulus of the polymers were determined. Wear was statistically analyzed with linear general models for repeated measures and material properties with one-way ANOVA with post-hoc Tukey-HSD tests. RESULTS: Wear of the antagonists was not influenced by the material (P ≥ 0.343). Likewise, no differences in wear resistance were found between materials after cyclic loading with 20 N or 50 N (P ≥ 0.074). Material properties investigated revealed decreased values for the resins for the additive manufacturing with the exception of flexural strength of one material. SIGNIFICANCE: Within the limitations of this in-vitro study, arylates for conventional, subtractive, and additive manufacturing of occlusal devices differ in material properties but not in wear resistance and antagonist wear.


Asunto(s)
Resistencia Flexional , Polímeros , Dureza , Humanos , Ensayo de Materiales , Estereolitografía , Propiedades de Superficie
18.
J Clin Med ; 9(8)2020 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-32785031

RESUMEN

Mid-term data on zirconia oral implants is very rare. Therefore, the aim of this prospective clinical investigation was to evaluate the survival rate and the marginal bone loss of a one-piece zirconia implant after five years. Patient-reported outcomes were also recorded. Zirconia implants to support single crowns (SC) or a 3-unit fixed dental prosthesis (FDP) were placed and subsequently restored. After the insertion of the implants, at prosthetic delivery, and after five years, standardized radiographs were taken to evaluate marginal bone loss (MBL). For bone tissue evaluation, linear mixed models with random intercepts were fitted. Twenty-seven patients received one implant for an SC and 13 patients received two implants for a 3-unit FDP. Three patients each lost one implant for an SC before prosthetic delivery. Thirty-five patients were seen after five years, and no further implant was lost. The cumulative five-year implant survival rate was 94.3%. The MBL from implant installation up to five years was 0.81 mm. The MBL from implant installation to prosthetic delivery was statistically significant (p < 0.001). Patients perceived a significant improvement in function, esthetics, sense, speech, and self-esteem from pretreatment up to the five-year follow-up. The present findings substantiate the clinical applicability of this implant system.

19.
J Mech Behav Biomed Mater ; 111: 103975, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32781402

RESUMEN

Concepts for digital denture manufacturing are market-available but studies comparing the trueness of such dentures, either milled (MIL) or additive manufactured, compared to injection molded (IM) ones are still limited. Regarding the impact of artificial aging and microwave sterilization on this parameter, no data are available. Therefore, the purpose of this investigation was to assess the trueness of IM, MIL, and stereolithography (SLA) printed denture bases after manufacturing, hydrothermal cycling, and microwave sterilization. Sixteen edentulous maxillary plaster models were poured using a silicone mold and digitized by means of a desktop scanner. For group IM, 16 denture bases were injection molded using these models. For group MIL and SLA, the denture bases were virtually designed and manufactured referring to the digitized data. A total of 48 samples were scanned 1) after manufacturing, 2) after hydrothermal cycling (5-55 °C, N = 5,000), and after 3) three as well as 4) six cycles of microwave sterilization for 6 min each at 640 W. The 3D surface deviation of the total intaglio surface, the palate, the alveolar ridge, and the border seal region was evaluated on the basis of the root mean square estimation (RMSE) and positive and negative mean deviations with an inspection software. For statistical analysis, ANOVA and post hoc Tukey tests were performed (α = 0.05). MIL showed the lowest deviations of the total RMSE (P ≤ .006) compared with the scans of the plaster models. In comparison, IM showed increased, mainly positive, deviations (P = .006) at the border seal. SLA presented the highest total RMSE (P = .001) with increased negative deviations, likewise at the border seal. In contrast to SLA (P = .001), no differences between IM and MIL (P = .816) were measured after hydrothermal cycling. Following microwave sterilization, the trueness of SLA was higher compared to IM and MIL (P = .001), with no differences between MIL and IM (P = .153). Distortion of IM and MIL was measured after the 3rd cycle with no further changes observed thereafter (P ≥ .385). It can be concluded, that subtractive manufacturing of denture bases results in the highest trueness, followed by IM and SLA. In contrast to IM and SLA, hydrothermal cycling did not affect MIL. Solely SLA printed denture bases remained dimensionally stable after microwave sterilization.


Asunto(s)
Bases para Dentadura , Diseño de Dentadura , Diseño Asistido por Computadora , Microondas , Esterilización
20.
J Clin Med ; 9(8)2020 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-32707759

RESUMEN

3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of <1 mm, vertical discrepancies of <0.6 mm, and axial deviations of ≤3°. In the vertical dimension, no differences between the four groups were measured (p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...