Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Oncol ; 11: 610637, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34178616

RESUMEN

PURPOSE/OBJECTIVE: Stereotactic body radiation therapy (SBRT) has emerged as a valid treatment alternative for non-resectable liver metastases or hepatocellular carcinomas (HCC). Magnetic resonance (MR) guided SBRT has a high potential of further improving treatment quality, allowing for higher, tumoricidal irradiation doses whilst simultaneously sparing organs at risk. However, data on treatment outcome and patient acceptance is still limited. MATERIAL/METHODS: We performed a subgroup analysis of an ongoing prospective observational study comprising patients with liver metastases or HCC. Patients were treated with ablative MR-guided SBRT at the MRIdian Linac in the Department of Radiation Oncology at Heidelberg University Hospital between January 2019 and February 2020. Local control (LC) and overall survival (OS) analysis was performed using the Kaplan-Meier method. An in-house designed patient-reported outcome questionnaire was used to measure patients' experience with the MR-Linac treatment. Toxicity was evaluated using the Common Terminology Criteria for Adverse Events (CTCAE v. 5.0). RESULTS: Twenty patients (with n = 18 metastases; n = 2 HCC) received MR-guided SBRT for in total 26 malignant liver lesions. Median biologically effective dose (BED at α/ß = 10) was 105.0 Gy (range: 67.2-112.5 Gy) and median planning target volume was 57.20 ml (range: 17.4-445.0 ml). Median treatment time was 39.0 min (range: 26.0-67.0 min). At 1-year, LC was 88.1% and OS was 84.0%. Grade I° gastrointestinal toxicity °occurred in 30.0% and grade II° in 5.0% of the patients with no grade III° or higher toxicity. Overall treatment experience was rated positively, with items scoring MR-Linac staff's performance and items concerning the breath hold process being among the top positively rated elements. Worst scored items were treatment duration, positioning and low temperature. CONCLUSION: MR-guided SBRT of liver tumors is a well-tolerated and well-accepted treatment modality. Initial results are promising with excellent local control and only mildest toxicity. However, prospective studies are warranted to truly assess the potential of MR-guided liver SBRT and to identify which patients profit most from this new versatile technology.

2.
Radiologe ; 61(Suppl 1): 39-48, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33392627

RESUMEN

INTRODUCTION: Hybrid magnetic resonance (MR) linear accelerators (MR-Linacs) for radiotherapy allow for the visualization and tracking of moving target volumes during the entire treatment. This makes gated treatments possible, decreasing the irradiated volumes and thus sparing healthy tissue from unnecessary radiation dose. Conventionally, tumors that are subject to respiration motion are treated by irradiating the entire area of potential target presence (internal target volume, ITV). This study presents three patient cases (lung, adrenal gland, and liver tumors) treated with gated MR-guided radiotherapy and compares the treatment plans retrospectively with conventional ITV plans. MATERIALS AND METHODS: The gross tumor volume was delineated on MR and computed tomography (CT) images of the patients, and MR-Linac treatment plans were generated using additional clinical and planning target volume margins. The motion of the gross tumor volume was evaluated on two-dimensional cine-MRI images during the entire MR-Linac treatment. Based on the motion analysis, standard ITV-based plans were retrospectively created and compared by means of irradiated target volumes and dose-volume parameters. RESULTS: For the MR-Linac plans, the irradiated treatment volumes were reduced by an average of 62% across the three cases, and for one case the ITV-based target volume would have overlapped with a critical organ. Target volume coverage was much better and the lung and adrenal MR-Linac plans revealed superior sparing of the organs at risks thanks to gated treatments. CONCLUSION: Dosimetrically beneficial treatment plans with promising clinical outcomes can be applied when using gated MR-guided radiotherapy. Future studies will reveal which patients will benefit most from this technique. To utilize the full potential of online adaptive, individualized MR-guided therapy, the close collaboration of radio-oncology and radiology is needed.


Asunto(s)
Imagen por Resonancia Magnética , Interpretación de Imagen Radiográfica Asistida por Computador , Humanos , Movimiento (Física) , Estudios Retrospectivos
3.
Strahlenther Onkol ; 196(8): 691-698, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32002567

RESUMEN

PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) has recently been introduced in our institution. As MRgRT requires high patient compliance compared to conventional techniques and can be associated with prolonged treatment times, feasibility and patient tolerance were prospectively assessed using patient-reported outcome questionnaires (PRO-Q). MATERIALS AND METHODS: Forty-three patients were enrolled in a prospective observational study and treated with MRgRT on a low-field hybrid Magnetic Resonance Linear Accelerator system (MR-Linac) between April 2018 and April 2019. For assistance in gated breath-hold delivery using cine-MRI, a video feedback system was installed. PRO-Qs consisted of questions on MR-related complaints and also assessed aspects of active patient participation. RESULTS: The most commonly treated anatomic sites were nodal metastases and liver lesions. The mean treatment time was 34 min with a mean beam-on time of 2:17 min. Gated stereotactic body radiotherapy (SBRT) was applied in 47% of all patients. Overall, patients scored MRgRT as positive or at least tolerable in the PRO­Q. Almost two thirds of patients (65%) complained about at least one item of the PRO­Q (score ≥4), mainly concerning coldness, paresthesia, and uncomfortable positioning. All patients reported high levels of satisfaction with their active role using the video feedback system in breath-hold delivery. CONCLUSION: MRgRT was successfully implemented in our clinic and well tolerated by all patients, despite MR-related complaints and complaints about uncomfortable immobilization. Prospective clinical studies are in development for further evaluation of MRgRT and for quantification of the benefit of MR-guided on-table adaptive radiotherapy.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias/radioterapia , Aceptación de la Atención de Salud , Radioterapia Guiada por Imagen , Adulto , Anciano , Anciano de 80 o más Años , Fraccionamiento de la Dosis de Radiación , Estudios de Factibilidad , Femenino , Retroalimentación Formativa , Alemania , Personal de Salud/psicología , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/psicología , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico por imagen , Neoplasias/psicología , Aceleradores de Partículas , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Radiocirugia , Radioterapia Guiada por Imagen/psicología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...