1.
IEEE Trans Biomed Eng ; 70(11): 3216-3226, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37285258

RESUMEN

Magnetic nanoparticles are being increasingly used in numerous biomedical applications for diagnosis and therapy. During the course of these applications nanoparticle biodegradation and body clearance may occur. In this context, a portable, non-invasive, non-destructive and contactless imaging device can be relevant to trace the nanoparticle distribution before and after the medical procedure. We present a method for in vivo imaging the nanoparticles based on the magnetic induction technique, and we show how to properly tune it for magnetic permeability tomography, maximizing the permeability selectivity. A tomograph prototype was designed and built to demonstrate the feasibility of the proposed method. It includes data collection, signal processing and image reconstruction. Useful selectivity and resolution are achieved on phantoms and animals, proving that the device can be used to monitor the presence of magnetic nanoparticles without requiring any particular sample preparation. By this way, we show that magnetic permeability tomography may become a powerful technique to assist medical procedures.

2.
Med Eng Phys ; 23(3): 235-8, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11410389

RESUMEN

A biopotential amplifier for single supply operation is presented. It uses a Driven Right Leg Circuit (DRL) to drive the patient's body to a DC common mode voltage, centering biopotential signals with respect to the amplifier's input voltage range. This scheme ensures proper range operation when a single power supply is used. The circuit described is especially suited for low consumption, battery-powered applications, requiring a single battery and avoiding switching voltage inverters to achieve dual supplies. The generic circuit is described and, as an example, a biopotential amplifier with a gain of 60 dB and a DC input range of +/-200 mV was implemented using low power operational amplifiers. A Common Mode Rejection Ratio (CMRR) of 126 dB at 50 Hz was achieved without trimming.


Asunto(s)
Amplificadores Electrónicos , Procesamiento de Señales Asistido por Computador/instrumentación , Impedancia Eléctrica , Suministros de Energía Eléctrica , Electrocardiografía , Diseño de Equipo
3.
IEEE Trans Biomed Eng ; 47(12): 1616-9, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11125597

RESUMEN

A three op-amps instrumentation amplifier (I.A) with active dc suppression is presented. dc suppression is achieved by means of a controlled floating source at the input stage, to compensate electrode and op-amps offset voltages. This isolated floating source is built around an optical-isolated device using a general-purpose optocoupler, working as a photovoltaic generator. The proposed circuit has many interesting characteristics regarding simplicity and cost, while preserving common mode rejection ratio (CMRR) and high input impedance characteristics of the classic three op-amps I.A. As an example, a biopotential amplifier with a gain of 80 dB, a lower cutoff frequency of 0.1 Hz, and a dc input range of +/- 8 mV was built and tested. Using general-purpose op-amps, a CMRR of 105 was achieved without trimmings.


Asunto(s)
Amplificadores Electrónicos , Fuentes de Energía Bioeléctrica , Impedancia Eléctrica , Instalación Eléctrica/instrumentación , Óptica y Fotónica , Procesamiento de Señales Asistido por Computador , Potenciales de Acción , Artefactos
4.
IEEE Trans Biomed Eng ; 46(12): 1466-70, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10612904

RESUMEN

Biopotential measurements are very sensitive to electromagnetic interference (EMI). EMI gets into the acquisition system by many ways, both as differential and common mode signals, driven-right-leg circuits (DRL) are widely used to reduce common mode interference. This paper reports an improvement on the classic DRL. The proposed circuit uses a transconductance amplifier to drive the patient's body. This configuration has some interesting properties, which provide an extended bandwidth for high-frequency EMI rejection (such as fluorescent lights interference). The improvement is around 20 dB for frequencies of few kilohertz and the circuit is easy to compensate for stability. A comparative analysis against a typical DRL is presented, the results obtained have been experimentally tested.