Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med Sci (Basel) ; 10(4)2022 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-36278526

RESUMEN

Background: Obesity is associated with increased all-cause mortality and cardiovascular disease (CVD). An electrocardiogram (ECG) may be used to screen for subtle signs of CVD or altered cardiac morphology in the obese. Methodology: This observational cross-sectional analysed ECG changes in patients with obesity at a tertiary care centre in southern India. Results: One hundred and fifty adult patients with a mean (SD) BMI of 39.9 (6.7) kg/m2 were recruited in the study after excluding those with comorbidities (diabetes mellitus, systemic hypertension) or on chronic medications (ACE inhibitors). The cohort showed a female predominance (69.3%), with a mean (SD) age of 45.4 (11.2) years. Most patients exhibited a sinus rhythm (78%), with one patient showing features of first-degree conduction block. Sinus tachycardia was seen in 32 (21.3%) patients. We observed left and right ventricular hypertrophy in five (3.3%) and three (2%) patients, respectively. Observed ECG patterns included a prolonged QTc in 16 (10.7%) patients, inverted T-waves (mostly in the inferior leads) in 39 (26%) patients and ST-segment depression (predominantly in the lateral leads) in 14 (9.3%) patients. A greater prevalence was noted for morbid obesity. No deaths were reported in our cohort. Conclusions: The predominant ECG variations in this cohort included tachycardia, atrial enlargement, ventricular hypertrophy, conduction defects, LAD, features of ischemia or old infarction and repolarization abnormalities, with a greater prevalence in morbid obesity. Further studies are needed to assess the impact of weight reducing measures on reversibility of these changes and determine the association with outcomes in obese patients.


Asunto(s)
Enfermedades Cardiovasculares , Obesidad Mórbida , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Proyectos Piloto , Estudios Transversales , Centros de Atención Terciaria , Electrones , Electrocardiografía , India/epidemiología , Inhibidores de la Enzima Convertidora de Angiotensina
4.
J Appl Clin Med Phys ; 17(3): 433-441, 2016 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-27167263

RESUMEN

Coronary angiography (CA) procedure uses various angiographic projections to elicit detailed information of the coronary arteries with some steep projections involving high radiation dose to patients. This study intends to evaluate radiation doses and estimated risk from angiographic projections during CA procedure performed using novel flat detector (FD) system with improved image processing and noise reduction techniques. Real-time monitoring of radiation doses using kerma-area product (KAP) meter was performed for 140 patients using Philips Clarity FD system. The CA procedure involved seven standard projections, of which five were extensively selected by interventionalists. Mean fluoroscopic time (FT), KAP, and reference air kerma (Ka,r) for CA procedure were 3.24 min (0.5-10.51), 13.99Gycm2 (4.02-37.6), and 231.43 mGy (73.8-622.15), respectively. Effective dose calculated using Monte Carlo-based PCXMC software was found to be 4.9mSv. Left anterior oblique (LAO) 45° projection contributed the highest radiation dose (28%) of the overall KAP. Radiation-induced risk was found to be higher in females compared to males with increased risk of lung cancer. An increase of 10%-15% in radiation dose was observed when one or more additional projections were adopted along with the seven standard projections. A 14% reduction of radiation dose was achieved from novel FD system when low-dose protocol during fluoroscopy and medium-dose protocol during cine acquisitions were adopted, compared to medium-dose protocol.


Asunto(s)
Cateterismo Cardíaco/métodos , Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Fluoroscopía/métodos , Órganos en Riesgo/efectos de la radiación , Monitoreo de Radiación/instrumentación , Femenino , Humanos , Masculino , Dosis de Radiación , Radiografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...