Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Minerva Anestesiol ; 81(6): 608-18, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25296880

RESUMEN

BACKGROUND: Clinical studies have raised concerns about the safety of 6% hydroxyethylstarch (HES) 130/0.42, but the pathomechanisms of this renal impairment remain unknown. To evaluate the effects of different HES concentrations, molar substitutions and molecular weights in HES-induced renal impairment, we used a porcine two-hit model that combined haemorrhagic and septic shock. METHODS: We conducted a prospective, randomised, double-blinded, controlled study in a university animal laboratory. Thirty anaesthetised and ventilated pigs were randomised to receive volume replacement therapy using 6% HES130/0.42, 6% HES200/0.5, 10% HES130/0.42 or 10% HES200/0.5, all dissolved in 0.9% NaCl rather than 0.9% NaCl alone. First, we bled the animals until they reached half of their baseline mean arterial pressure (MAP) for 45 minutes followed by fluid resuscitation. As a second hit, sepsis was induced using an Escherichia coli-laden clot 6 hours after haemorrhagic shock. Volume resuscitation started with a delay of two hours and a central venous pressure goal of 12 mmHg. RESULTS: At the end of the study, the groups showed no difference in cardiac output or MAP, but the volume balance (mL/kg BW) was significantly higher in the 0.9% NaCl group (346±90; P≤0.05) than in the other groups (6% HES130, 125±26; 6% HES200, 105±15; 10% HES130, 114±17; 10% HES200, 96±23). Creatinine clearance (mL/min) was significantly lower in the 6% HES200 (26±33) and 10% HES200 (15±18) groups compared to the 0.9% NaCl group (104±46; P≤0.05) but not in the HES 130 formulations (6% HES130: 64±51; 10% HES130: 58±38) at the end of the study. CONCLUSION: In this porcine two-hit shock model, treatment with 0.9% NaCl, HES 130/0.42 or HES 200/0.5 led to a similar maintenance of haemodynamic values. Despite this similar maintenance of the haemodynamic values, volume replacement with 6% and 10% HES 200/0.5 led to an accumulation of HES, higher colloid osmotic pressure and significantly reduced renal function after haemorrhagic and septic shock. These facts support the presumption that not the concentration but the degree of substitution and the molecular weight play a decisive role in HES-induced renal impairment.


Asunto(s)
Derivados de Hidroxietil Almidón/análogos & derivados , Enfermedades Renales/inducido químicamente , Sustitutos del Plasma/efectos adversos , Sustitutos del Plasma/química , Choque Hemorrágico/tratamiento farmacológico , Choque Séptico/tratamiento farmacológico , Animales , Relación Dosis-Respuesta a Droga , Femenino , Derivados de Hidroxietil Almidón/efectos adversos , Derivados de Hidroxietil Almidón/química , Derivados de Hidroxietil Almidón/uso terapéutico , Pruebas de Función Renal , Peso Molecular , Sustitutos del Plasma/uso terapéutico , Porcinos
2.
Science ; 296(5574): 1852-5, 2002 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-12052956

RESUMEN

The inferred crystallographic class of circumstellar silicon carbide based on astronomical infrared spectra is controversial. We have directly determined the polytype distribution of circumstellar SiC from transmission electron microscopy of presolar silicon carbide from the Murchison carbonaceous meteorite. Only two polytypes (of a possible several hundred) were observed: cubic 3C and hexagonal 2H silicon carbide and their intergrowths. We conclude that this structural simplicity is a direct consequence of the low pressures in circumstellar outflows and the corresponding low silicon carbide condensation temperatures.


Asunto(s)
Astronomía , Compuestos Inorgánicos de Carbono/análisis , Meteoroides , Compuestos de Silicona/análisis , Fenómenos Astronómicos , Microscopía Electrónica , Presión , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...