Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Hand Surg Asian Pac Vol ; 22(2): 184-187, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28506180

RESUMEN

BACKGROUND: Specific treatment of the volar marginal rim fragment of distal radius fractures avoids occurance of volar radiocarpal dislocation. Although several fixation systems are available to capture this fragment, adequately maintaining internal fixation is difficult. We present our experience of the first 10 cases using the 2.4 mm variable angle LCP volar rim distal radius plate (Depuy Synthes®, West Chester, US), a low-profile volar rim-contouring plate designed for distal plate positioning and stable buttressing of the volar marginal fragment. METHODS: Follow-up patient satisfaction, range of motion, grips strength, functional scoring with the QuickDASH and residual pain with a numeric rating scale were assessed. Radiological evaluation consisted in evaluating fracture consolidation, ulnar variance, volar angulation and maintenance of the volar rim fixation. RESULTS: The female to male ratio was 5:5 and the mean age was 52.2 (range, 17-80) years. The mean follow-up period was 11 (range, 5-19) months postoperatively. Patient satisfaction was high. The mean total flexion/extension range was 144° (range, 100-180°) compared to the contralateral uninjured side 160° (range, 95-180°). The mean total pronation/supination range was 153° (range, 140-180°) compared to the contralateral uninjured side 170° (range, 155-180°). Mean grip strength was 14 kg (range, 9-22), compared to the contralateral uninjured side 20 kg (range, 12-25 kg). Mean pre-injury level activity QuickDASH was 23 (range, 0-34.1), while post-recovery QuickDASH was 25 (range 0-43.2). Residual pain was 1.5 on the visual numerical pain rating scale. Radiological evaluation revealed in all cases fracture consolidation, satisfactory reconstruction of ulnar variance, volar angulation and volar rim. We encountered no flexor tendon complications, although plate removal was systematically performed after fracture consolidation. CONCLUSIONS: The 2.4 mm variable angle LCP volar rim distal radius plates is a valid treatment option for treating the volar marginal fragment in distal radius fractures.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/instrumentación , Fracturas del Radio/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Fuerza de la Mano/fisiología , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Pronación/fisiología , Fracturas del Radio/diagnóstico por imagen , Rango del Movimiento Articular/fisiología , Supinación/fisiología , Escala Visual Analógica , Articulación de la Muñeca/fisiopatología , Adulto Joven
2.
Skeletal Radiol ; 44(12): 1709-25, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26219592

RESUMEN

The scapholunate joint is one of the most involved in wrist injuries. Its stability depends on primary and secondary stabilisers forming together the scapholunate complex. This ligamentous complex is often evaluated by wrist arthroscopy. To avoid surgery as diagnostic procedure, optimization of MR imaging parameters as use of three-dimensional (3D) sequences with very thin slices and high spatial resolution, is needed to detect lesions of the intrinsic and extrinsic ligaments of the scapholunate complex. The paper reviews the literature on imaging of radial-sided carpal ligaments with advanced computed tomographic arthrography (CTA) and magnetic resonance arthrography (MRA) to evaluate the scapholunate complex. Anatomy and pathology of the ligamentous complex are described and illustrated with CTA, MRA and corresponding arthroscopy. Sprains, mid-substance tears, avulsions and fibrous infiltrations of carpal ligaments could be identified on CTA and MRA images using 3D fat-saturated PD and 3D DESS (dual echo with steady-state precession) sequences with 0.5-mm-thick slices. Imaging signs of scapholunate complex pathology include: discontinuity, nonvisualization, changes in signal intensity, contrast extravasation (MRA), contour irregularity and waviness and periligamentous infiltration by edema, granulation tissue or fibrosis. Based on this preliminary experience, we believe that 3 T MRA using 3D sequences with 0.5-mm-thick slices and multiplanar reconstructions is capable to evaluate the scapholunate complex and could help to reduce the number of diagnostic arthroscopies.


Asunto(s)
Artrografía/métodos , Inestabilidad de la Articulación/diagnóstico , Ligamentos Articulares/lesiones , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Traumatismos de la Muñeca/diagnóstico , Humanos , Aumento de la Imagen/métodos , Ligamentos Articulares/diagnóstico por imagen , Ligamentos Articulares/patología , Hueso Semilunar/diagnóstico por imagen , Hueso Semilunar/lesiones , Hueso Semilunar/patología , Reproducibilidad de los Resultados , Hueso Escafoides/diagnóstico por imagen , Hueso Escafoides/lesiones , Hueso Escafoides/patología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA