Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cardiovasc Revasc Med ; 62: 40-47, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38135568

RESUMEN

BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.


Asunto(s)
Válvula Aórtica , Cateterismo Periférico , Arteria Femoral , Punciones , Radiografía Intervencional , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Ultrasonografía Intervencional , Humanos , Arteria Femoral/diagnóstico por imagen , Masculino , Femenino , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Anciano , Fluoroscopía , Resultado del Tratamiento , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Factores de Riesgo , Radiografía Intervencional/efectos adversos , Prótesis Valvulares Cardíacas , Factores de Tiempo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis
3.
Catheter Cardiovasc Interv ; 102(5): 889-891, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37702150

RESUMEN

Undeployed stent loss is a rare but potentially serious complication of percutaneous coronary intervention. Its management is not assisted by well-defined guidelines, and it is made even more difficult when the dislodged stent is not protected by in situ guidewire. In this work, we present the case of a total stent loss with a crushed device protruding out of the left main. In this hopeless circumstance, an innovative ping-pong technique was used to contralaterally perform a successful stent retrieval.


Asunto(s)
Angioplastia Coronaria con Balón , Intervención Coronaria Percutánea , Humanos , Resultado del Tratamiento , Stents , Intervención Coronaria Percutánea/efectos adversos , Remoción de Dispositivos/métodos
5.
J Cardiovasc Echogr ; 29(4): 169-171, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32089997

RESUMEN

Current guidelines consider thrombosis as a potential (and reversible) cause of cardiorespiratory arrest (CA). However, cardiac thrombus formation (TF) is likely to be the consequence of the forward blood flow ceasing during cardiac standstill. We present the case of a young man who was hospitalized for infective endocarditis, complicated by multiorgan disease and sudden CA on the 5th day. Prompt cardiopulmonary resuscitation (CPR) warranted a return of spontaneous circulation in 16 min but, unexpectedly, a TF was recognized in the right atrium at echocardiography. The blood clot resolved with rapid administration of endovenous heparin and continued chest compressions. Even though cardiac ultrasound is not ready for a routine use during CPR, the present study confirms a key role in the management of CA patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...