Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Laryngoscope ; 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38332515

RESUMEN

OBJECTIVE: Translabyrinthine excision of a vestibular schwannoma is associated with acute vestibular failure. Preoperative intratympanic gentamicin (ITG) injections can improve objective balance function after surgery but its clinical benefits remain to be established. METHODS: Adult patients undergoing translabyrinthine removal of a vestibular schwannoma between January 2014 and February 2018 underwent preoperative vestibular function testing. Patients were divided in to 3 groups, those with vestibular function (VF) who received ITG injections, those with VF but did not receive ITG and those with no VF. Groups were compared according to degree of vertigo, length of stay, time to unassisted mobilization, and postoperative anti-emetic consumption. RESULTS: Forty six patients had ITG injections (Group 1), 7 had residual VF but refused treatment (Group 2), 21 had no VF (Group 3). Group 1 had a significant improvement in vertigo over time whereas groups 2 and 3 did not. There was a statistically significant 70% decrease in time to independent mobilization between Group 1 and other groups and a 19% decrease in length of stay in Group 1 compared to other groups although this did not reach statistical significance. Two patients had injection-related complications. Group 1 used less anti-emetics than other groups but this was not statistically significant. CONCLUSION: Preoperative intratympanic gentamicin injection with vestibular rehabilitation exercises is associated with less postoperative vertigo and earlier postoperative mobilization. There was reduced duration of hospitalization and decreased consumption of anti-emetic but not significantly so possibly because of low numbers of patients in the no treatment group. LEVEL OF EVIDENCE: 2 Laryngoscope, 2024.

2.
Cochlear Implants Int ; 24(5): 260-267, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36938810

RESUMEN

OBJECTIVE: Many patients with cochlear implants (CI) and auditory brainstem implants (ABI) require magnetic resonance imaging (MRI) following implantation. This study explores the patient experience of MRI, identifying factors associated with pain, and the effect of interventions designed to enhance comfort and safety. METHODS: A prospective observational case series from a tertiary referral unit. Tight head bandaging ± local anaesthetic injection (devices with non-MRI-compatible magnets) or observation alone (implants with MRI-compatible magnets) were employed for 1.5 T MRI of consecutive adult patients with CI or ABI without magnet removal. Pain was recorded via visual analogue scale (1 = no pain, 5 = extreme pain) at three time points; (1) baseline, (2) head bandage applied (3) during scanning. Patient age, device type, body area imaged and total scan time were recorded as variables, alongside adverse events. RESULTS: Data were collected for 227 MRI scans (34 patients with ABI, 32 with CI). In patients managed with bandaging, pain score after bandaging but prior to scanning (median 2.2) did not differ from pain during scanning (2.1), but both were significantly higher than baseline (1.4, both P ≤ 0.001). Scanning areas other than the head/cervical spine was associated with higher pain scores (P = 0.036). Pain during MRI differed between different manufacturers implants (P ≤ 0.001). Adverse events occurred in 8/227 scans (3.5%), none occurring with devices containing an MRI-compatible magnet. CONCLUSION: MRI scanning with auditory implant magnets in situ is safe and well tolerated by patients.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Implantación Coclear , Implantes Cocleares , Adulto , Humanos , Imagen por Resonancia Magnética/métodos , Implantes Cocleares/efectos adversos , Espectroscopía de Resonancia Magnética
3.
Clin Otolaryngol ; 47(1): 100-106, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34687146

RESUMEN

OBJECTIVE: To objectively assess the utility of an exoscope during simulated otological surgery. DESIGN: Cohort study. SETTING: Tertiary referral otolaryngology centre. PARTICIPANTS: Seven experienced otologists undertook simulated temporal bone surgery on plastic temporal bones using the Zeiss Kinevo microscope with both a microscope and exoscope facility. OUTCOME MEASURES: The utility of microscope and exoscope was compared using a Likert scale from 1 to 10 with and without PPE. Attributes assessed included image quality, depth perception, adequacy of view, exoscope positioning, surgeon comfort, surgeon safety and adequacy of image and protection for assistants and observers. RESULTS: The exoscope in 3D mode performed as well as or better than the microscope for image quality, field of view and manoeuvrability. It outperformed the microscope for compatibility with PPE, surgeon comfort and assistant/observer experience. It scored almost as highly as the microscope for depth perception. CONCLUSION: There is likely to be a learning curve but this initial assessment of the exoscope shows significant potential as an alternative to the operating microscope in otological surgery but with the advantage of allowing the use of appropriate PPE and better ergonomics for both surgeon and assistant/observer.


Asunto(s)
Imagenología Tridimensional/instrumentación , Microscopía/instrumentación , Microcirugia/instrumentación , Procedimientos Quirúrgicos Otológicos/instrumentación , Hueso Temporal/cirugía , Estudios de Cohortes , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...