Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Case Rep Ophthalmol Med ; 2023: 8115622, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37102122

RESUMEN

Lipid keratopathy (LK) is a rare disease involving lipid deposition in the cornea resulting in corneal opacification. Primary LK can arise sporadically while secondary LK is seen in patients with a history of ocular trauma, medication exposure, infection, inflammation, or disorders resulting in derangements of lipid metabolism. Secondary LK is more common and occurs due to neovascularization. Use of precipitating medications should be considered in LK workup, particularly for patients in whom other etiologies have been ruled out. Brimonidine, an ocular hypotensive medication, can be associated with LK. We present a case of bilateral secondary LK in a patient with a history of prolonged brimonidine use, without additional contributing factors.

2.
Clin Ophthalmol ; 17: 135-143, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36644604

RESUMEN

Purpose: To analyze refractive changes after neodymium: yttrium-aluminum-garnet (Nd:YAG) posterior capsulotomy in pseudophakic eyes. Patients and Methods: Patients who underwent Nd:YAG capsulotomy after cataract surgery from January 2013 to April 2022 were included in this retrospective study. Sphere, cylinder, spherical equivalent (SE), axis, and corrected distance visual acuity (CDVA) were compared pre- and postoperatively in 683 eyes of 548 patients at one month (n = 605 eyes) and one year (n = 211 eyes). Patients with both one-month and one-year follow-ups (n = 133) were also compared. Eyes were stratified into single-piece (n = 330), three-piece (n = 30), and light adjustable lenses (LALs) (n = 16). Pre- and postoperative measurements were analyzed within each group. Results: Cylinder was significantly decreased at one-month (difference: 0.042±0.448 D, p = 0.006) and one-year (difference: 0.101±0.455 D, p = 0.003) compared to preoperative measurements. No significant change in sphere or axis was observed at follow-up visits (p > 0.05). CDVA significantly improved at both time points (p < 0.05). No significant change in any parameters between the one-month and one-year groups was observed (p > 0.05). There was significant improvement in CDVA in the single and three-piece lens groups (p < 0.0001 and p = 0.026, respectively), with no change in the LAL group (p > 0.05). Conclusion: There were no changes in sphere, axis, or spherical equivalent after Nd:YAG capsulotomy. However, cylindrical error and CDVA were significantly better after the procedure. Lens type did not impact refractive parameters postoperatively.

3.
J Clin Med ; 11(24)2022 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-36555990

RESUMEN

This study compares the visual and refractive performance of the TECNIS Synergy (DFR00V-DFW150-225-300-375) multifocal intraocular lens (IOL) and the AcrySof IQ PanOptix (TFAT00-30-40-50-60) multifocal IOL. Patients who underwent phacoemulsification and cataract extraction and received either a multifocal Synergy or PanOptix IOL were included. Monocular uncorrected distance (UDVA), intermediate (UIVA), near (UNVA), and corrected distance (CDVA) visual acuities were assessed at three and six months postoperatively. Secondary outcome measures of photic phenomena were also assessed. A total of 140 patients (224 eyes) were included in this study, with 69 patients (105 eyes) in the Synergy group and 71 patients (119 eyes) in the PanOptix group. There were no statistically significant differences in UIVA or CDVA measurements across all time points. When assessing UDVA, at three months postoperatively, there were more eyes in the PanOptix group with vision better than 20/40 (p = 0.04). At three and six months postoperatively, the average UNVA was superior in the Synergy group (p = 0.01, 0.002). While the Synergy group reported more night vision disturbances at one and three months (p = 0.01, 0.03), the PanOptix group had more night vision disturbances at six months (p = 0.02). Although not statistically significant, the AcrySof IQ PanOptix multifocal IOL demonstrated better UDVA and UIVA sooner postoperatively than the TECNIS Synergy multifocal IOL. The Synergy IOL provided statistically better UNVA compared to the PanOptix IOL at three and six months postoperatively. Synergy patients reported more early photic phenomena than PanOptix patients, which later diminished.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA