Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
Am J Cardiol ; 212: 118-126, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38036051

RESUMEN

Given the expanding indications toward younger patients at lower surgical risk, transcatheter aortic valve replacement (TAVR) simplification and streamlining are gaining increasing importance. Patients who underwent TAVR from the year 2015 to 2020 were prospectively enrolled. The patients were divided in time tertiles according to the date of intervention. Data on preprocedural planning, including coronary computed tomography angiography (CCTA), procedures, and outcomes, were compared between the time tertiles. A total of 771 consecutive patients from a single institution were enrolled. We observed a trend toward the use of a fully percutaneous versus surgical approach for the index access, left radial artery versus contralateral femoral artery for the secondary access, and left ventricular pacing on the stiff guidewire versus right ventricular pacing. Immediate device success significantly increased, whereas the length of hospital stay decreased. Overall, approximately 60% of the total study population underwent CCTA instead of coronary angiography, with no adverse events. One-year survival rates significantly improved over time. A simplified TAVR approach was associated with better survival, whereas low baseline functional capacity, preexisting coronary artery disease, renal impairment, periprocedural blood transfusions, and paravalvular leak were related to worse outcomes. In conclusion, our study showed a constant tendency to procedure streamlining and improve procedural success and 1-year outcomes. A strategy based on CCTA allows sparing safely almost half of the preoperative invasive coronary angiography.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Angiografía Coronaria , Estudios Retrospectivos
3.
Eur J Heart Fail ; 24(11): 2175-2184, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36482160

RESUMEN

AIM: To evaluate short-term changes in tricuspid regurgitation (TR) after transcatheter edge-to-edge mitral valve repair (M-TEER) in secondary mitral regurgitation (SMR), their predictors and impact on mortality. METHODS AND RESULTS: This is a retrospective analysis of SMR patients undergoing successful M-TEER (post-procedural mitral regurgitation ≤2+) at 13 European centres. Among 503 patients evaluated 79 (interquartile range [IQR] 40-152) days after M-TEER, 173 (35%) showed ≥1 degree of TR improvement, 97 (19%) had worsening of TR, and 233 (46%) remained unchanged. Smaller baseline left atrial diameter and residual mitral regurgitation 0/1+ were independent predictors of TR ≤2+ after M-TEER. There was a significant association between TR changes and New York Heart Association class and pulmonary artery systolic pressure decrease at echocardiographic re-assessment. At a median follow-up of 590 (IQR 209-1103) days from short-term echocardiographic re-assessment, all-cause mortality was lower in patients with improved compared to those with unchanged/worsened TR (29.6% vs. 42.3% at 3 years; log-rank p = 0.034). Baseline TR severity was not associated with mortality, whereas TR 0/1+ and 2+ at short-term follow-up was associated with lower all-cause mortality compared to TR 3/4+ (30.6% and 35.6% vs. 55.6% at 3 years; p < 0.001). A TR ≤2+ after M-TEER was independently associated with a 42% decreased risk of mortality (p = 0.011). CONCLUSION: More than one third of patients with SMR undergoing successful M-TEER experienced an improvement in TR. Pre-procedural TR was not associated with outcome, but a TR ≤2+ at short-term follow-up was independently associated with long-term mortality. Optimal M-TEER result and a small left atrium were associated with a higher likelihood of TR ≤2+ after M-TEER.


Asunto(s)
Insuficiencia Cardíaca , Válvula Mitral , Humanos , Estudios Retrospectivos
4.
J Cardiovasc Med (Hagerstown) ; 23(12): 801-806, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36219144

RESUMEN

AIMS: Local instead of general anesthesia has become the standard approach in many centers for transfemoral transcatheter aortic valve replacement (TAVR). New generation devices and an increase in operator skills had led to a drastic reduction in periprocedural complications, bringing in the adoption of a minimalist approach. In our study, we aimed to compare patients treated with TAVR under local anesthesia with or without the presence of an anesthesiologist on site (AOS). METHODS: We compare procedural aspects and results of patients treated with TAVR with an AOS against patients treated with TAVR with an anesthesiologist on call (AOC). From January 2019 to December 2020, all consecutive patients undergoing transfemoral TAVR with either the self-expandable Evolut (Medtronic, MN, USA) or balloon-expandable SAPIEN 3 (Edwards Lifesciences, CA, USA) were collected. RESULTS: Of 332 patients collected, 96 (29%) were treated with TAVR with AOS, while 236 (71%) were treated with TAVR with AOC. No differences in procedural time, fluoroscopy time and amount of contrast medium were observed. No procedural death and conversion to open-chest surgery was reported. The rate of stroke/transient ischemic attacks and major vascular complications was similar in the two groups. No patients in both groups required conversion to general anesthesia. Two patients (0.8%) in the AOC group required urgent intervention of the anesthesiologist. In the AOC group, there was a greater use of morphine (55.9% vs. 33.3%, P  = 0.008), but with a lower dose for each patient (2.0 vs. 2.8 mg, P  = 0.006). On the other hand, there was a lower use of other painkiller drugs (3.4% vs. 20.8%, P  = 0.001). No difference in inotropic drugs use was observed. CONCLUSION: In patients at low or intermediate risk undergoing transfemoral TAVR, a safe procedure can be performed under local anesthesia without the presence of an anesthesiologist in the catheterization laboratory.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Anestesiólogos , Diseño de Prótesis , Resultado del Tratamiento , Fluoroscopía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
5.
JACC Case Rep ; 4(16): 1005-1011, 2022 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-36062048

RESUMEN

Torrential tricuspid regurgitation may lead to heart failure and poor survival and quality of life. Heterotopic transcatheter tricuspid replacement is increasingly offered to patients unsuitable for direct valve repair or replacement. We describe 1 patient treated by transcatheter implantation of 2 self-expanding valves in the venae cavae with a multimodality imaging approach. (Level of Difficulty: Advanced.).

6.
Eur J Heart Fail ; 24(7): 1282-1292, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35642951

RESUMEN

AIMS: To investigate the role of left atrial volume index (LAVi) in patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge mitral valve repair (TEER). METHODS AND RESULTS: Outcomes were evaluated in SMR patients of a European multicentre registry according to baseline LAVi. Main analysis was performed for all-cause mortality; residual mitral regurgitation (MR) and New York Heart Association (NYHA) class improvement were analysed for patients available. A total of 1074 patients were included with a median LAVi (interquartile range) of 58 ml/m2 (46-73). Postprocedural reduction of MR grade to ≤2+ was similar across LAVi quintiles, ranging 91%-96% (p = 0.26). Symptomatic benefit (≥1 NYHA class improvement) also did not differ by LAVi quintiles (61%-68% of patients) (p = 0.66). The risk of mortality increased by 23%-42% in the four upper quintiles compared to the bottom quintile (LAVi <42 ml/m2 ). The hazard ratio (HR) of mortality was 1.35 (95% confidence interval [CI] 1.02-1.78, p = 0.035) associated with a LAVi >42 ml/m2 , which was attenuated after multivariable adjustment (HR 1.18, 95% CI 0.83-1.67, p = 0.36). A significant interaction was found for MR severity and pulmonary hypertension, with an increased risk of death associated with enlarged LAVi in patients with inframedian effective regurgitant orifice area (HR 1.99, 95% CI 1.06-3.74, p = 0.032) and in patients with systolic pulmonary pressure ≤50 mmHg (HR 1.67, 95% CI 1.02-2.75, p = 0.042) in multivariable analysis. CONCLUSION: Procedural success and symptomatic benefit were high throughout the whole range of LAVi. The prognostic impact of left atrial enlargement was relevant in patients with less severe SMR and without pulmonary hypertension, reinforcing the need to identify patients in the early course of backward congestion to achieve good long-term outcome after TEER.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Hipertensión Pulmonar , Insuficiencia de la Válvula Mitral , Atrios Cardíacos/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Hipertensión Pulmonar/etiología , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
7.
Int J Cardiol ; 349: 39-45, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-34826500

RESUMEN

BACKGROUND: A-FMR is considered a specific sub-type of secondary MR in patients with atrial fibrillation (AF) and preserved left ventricle ejection fraction (LVEF). Aim of the study was to investigate the acute and mid-term outcomes of transcatheter edge-to-edge mitral valve repair (TMVr) with the MitraClip in atrial functional mitral regurgitation (A-FMR). METHODS: The study included patients with A-FMR and concomitant AF who underwent to the MitraClip at 7 Italian Centers. Aim of the study was to assess the safety, efficacy and mid-term cardiovascular outcomes. RESULTS: After reviewing 1153 patients with FMR treated with TMVr from 2009 to 2021, 87 patients (median age 81 years, 61% female) with A-FMR were identified. Technical success was achieved in 97%, 30-day device success in 83% and 30-day procedural success in 80%. All-cause death at 30-day was 5%. Estimated two-year freedom from all-cause death and cardiac death was 60% and 77%, respectively, whereas freedom from all-cause death/heart failure hospitalization was 55%. Residual MR ≤ 2+ was encountered in 89% (n = 47/53) and improvement in NYHA class I/II in 79% (n = 48/61). Post-procedural MR ≥ 2+ (HR 5.400, CI 1.371-21.268) and inter-commissural annular diameter ≥ 35 mm (HR 4.159, CI 1.057-16.363) were independent predictors of all-cause death/heart failure hospitalization during the follow-up. Positive reverse remodeling of left atrium and mitral annular dimensions occurred after TMVr during the follow-up. CONCLUSIONS: MitraClip resulted to be a safe and effective option to treat A-FMR in elderly patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Femenino , Atrios Cardíacos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...