Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
J Oral Implantol ; 27(1): 32-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11326539

RESUMEN

The clinical and histological results of two cases demonstrating retrieved Sendax mini-dental implants in two different patients is the focus of this report. The mini-dental implants were inserted using the auto-advance technique and loaded immediately. The implants were retrieved at 4 months following insertion and at 5 months following insertion and were prepared and reviewed histologically. Clinically, the implants had no mobility, with no apparent exudate or bleeding upon probing, prior to removal. At the time explant procedures were performed, the mini-dental implants had provided immediate support for prostheses during the integration of traditional root-form endosteal implants. Upon explantation, the mini-dental implants were in a state of health and functioning in their intended purpose. Histologically, the bone appeared to be integrated to the surface of the implant at the light microscope level, and the bone appeared to be relatively mature and healthy in the areas observed, more so than one would expect in this amount of time from insertion of mini-dental implants with immediate loading. A discussion of the purposes and technique used for insertion and removal of these mini-dental implants is discussed. This is the first human histological report on the auto-advance technique with immediate loading of mini-dental implants, demonstrating feasibility in ongoing applications.


Asunto(s)
Implantación Dental Endoósea/métodos , Implantes Dentales , Diseño de Prótesis Dental , Restauración Dental Provisional , Anciano , Retención de Prótesis Dentales , Remoción de Dispositivos , Humanos , Arcada Parcialmente Edéntula/rehabilitación , Masculino , Mandíbula/cirugía , Miniaturización , Oseointegración
2.
J Oral Implantol ; 27(1): 5-15, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11326542

RESUMEN

This paper reports analysis obtained from 200 implant cases retrieved from humans and submitted to the American Academy of Implant Dentistry Research Foundation, Medical College of Georgia implant retrieval center. The samples that were not decalcified were embedded in polymethylmethacrylate and examined with scanning electron microscopy and routine light, polarized, or Nomarski microscopy. Cases included both orthopedic and dental implants, as well as entire mandibles and portions of maxillae obtained at autopsy. A significant number of submitted implants had substantial amounts of adhered bone, which permitted evaluation of human bone remodeling to osseointegrated implants. These implants failed because of implant fracture. As was observed with animal studies, healthy bone supported these implants, with the bone containing an interdigitating canaliculi network that provided communication between interfacial osteocytes and osteocytes deeper within the remodeled osteonal and trabecular bone. Early dental implants containing a coating of beads showed a connective tissue interface, which corresponded to the bead surface of specific orthopedic implants that underwent some degree of micromovement. This is in contrast with the excellent response reported for successful contemporary beaded implants. Significant numbers of osseointegrated fractured hydroxyapatite (HA)-coated dental implants demonstrated the adequate serviceability of these implants before biomaterial fracture. In contrast, the HA coating was dissociated from retrieved orthopedic implants, leading to extensive cup loosening and case failure. This study, therefore, underscores the need for evaluation of failed human dental and orthopedic implants. Correlations can be drawn between human retrieval and experimental animal studies.


Asunto(s)
Materiales Biocompatibles Revestidos , Implantación Dental Endoósea , Remoción de Dispositivos , Prótesis e Implantes , Falla de Prótesis , Óxido de Aluminio , Animales , Durapatita , Análisis de Falla de Equipo , Humanos , Oseointegración , Propiedades de Superficie
3.
J South Orthop Assoc ; 10(1): 6-11, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-12132846

RESUMEN

The extended proximal femoral osteotomy is becoming increasingly popular in revision total hip replacement. Our study was done to determine the femoral stem length required for stable fixation of a cementless femoral component after an extended proximal femoral osteotomy. Three lengths of the S-ROM femoral stem were implanted in paired cadaver femora and tested under torsional and axial loads. The results indicate that the standard (160 mm) and long (215 mm) stems do not provide adequate torsional stability after a 160 mm extended proximal femoral osteotomy. The extra-long (255 to 315 mm) stems provided significantly greater stability, suggesting that the extended proximal femoral osteotomy may need to be bypassed by more than 2 cortical diameters, especially when a flexible stem such as the S-ROM is used.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fémur/cirugía , Osteotomía/métodos , Humanos , Diseño de Prótesis , Reoperación
4.
Crit Rev Biomed Eng ; 28(3 - 4): 395-8, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11108205

RESUMEN

Retrieval analyses disclosed in vivo dissociation of HA in orthopaedic acetabular components, but excellent bone ingrowth into intact HA coatings on dental retrievals. Initial healing and the bone interface between HA-coated and non-coated implants in the posterior maxilla (Mx) and mandible (Md) was assessed in an animal model using light microscopy (LM), including confocal (CM) and Nomarski (NM) microscopy. Seventy-two implants (36 HA-coated; 36 non-coated) were placed into jaws of six dogs; half after extraction, half after 3 months healing. Animals were euthanized 3 months postimplantation. All implants osseointegrated; however, preliminary morphometry showed higher BCL for HA-coated (51%) than non-coated implants (44%) in the Mx (p < 0.05). BCL for HA-coated Md implants was not significantly higher (64%) than non-coated implants (62%). Bone closely apposed both implant types; however, LM suggested a more intimate association with HA coatings. Serial sections disclosed a reddish coating on the HA, possibly analogous to oral tissue proteoglycans, which was not visible with non-coated implants. This material was continuous with similar material coating endosteum, osteoid regions, and osteocyte (Os) lacunae close to the implant. An interdigitating canaliculi network allowed communication between interfacial Os and Os deeper within the bone. Data suggest HA offers enhanced initial bone fixation in the Mx, and that adequate bone exists for non-coated implant stability in the Md. No HA dissociation was seen with implants in the animal study, which was consistent with retrieved human HA dental implants.


Asunto(s)
Materiales Biocompatibles Revestidos , Durapatita , Ensayo de Materiales , Prótesis e Implantes , Acetábulo/cirugía , Análisis de Varianza , Animales , Huesos/patología , Implantes Dentales , Perros , Matriz Extracelular/patología , Humanos , Mandíbula/cirugía , Maxilar/cirugía , Oseointegración , Cicatrización de Heridas
5.
J Pediatr Orthop ; 20(5): 682-5, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11008753

RESUMEN

Patients with sickle cell disease have been documented to be particularly susceptible to osteoarticular infections. Controversy exists concerning the bacteriology, etiology, and clinical presentation in differentiating osteoarticular infections from bone infarct. We retrospectively reviewed all cases from our institution over the past 22 years of osteoarticular infections in children who carry the diagnosis of sickle cell disease. Two thousand consecutive patient charts of children enrolled in the Pediatric Sickle Cell Clinic of our institution between 1973 and 1995 were evaluated. There were 14 cases of bone or joint infections (10 osteomyelitis, four septic arthritis). There was one case of multicentric osteomyelitis and one case of meningitis complicating the septic arthritis. There were nine male and five female patients with ages ranging from 6 months to 17 years (mean, 8.0). All patients were noted to have hemoglobin SS. The predominant presenting symptoms were pain (79% of cases) and swelling (71% of cases). The most frequent physical findings were fever >38.2 degrees C (71% of cases) and tenderness (86% of cases). Ninety-three percent of the children had a white blood count exceeding 15,000/mm3 (range, 7,900-32,300). Westergren sedimentation rates ranged from 14 to 89 mm/h with 93% of the children exceeding the normal value in our hospital. Cultures were positive in 75% of tissue biopsies, 58% of the blood cultures, and 70% of the bone or joint aspirates. The most common offending organism found in osteomyelitis was Salmonella (eight of 10 cases); however, no predominant organism found was identified in cases of septic arthritis. Radiographs and bone scans were of limited value in the differential diagnosis between osteoarticular infections and bone infarction. Early diagnosis and treatment of osteoarticular infections is key to satisfactory outcome. This study suggests that an ill-appearing patient with a fever >38.2 degrees C, pain, and swelling should prompt the physician to aspirate or biopsy the area and not rely on diagnostic studies that we found to be unreliable.


Asunto(s)
Anemia de Células Falciformes/complicaciones , Artritis Infecciosa/epidemiología , Osteomielitis/epidemiología , Infecciones por Salmonella/epidemiología , Adolescente , Factores de Edad , Antibacterianos/uso terapéutico , Artritis Infecciosa/diagnóstico , Artritis Infecciosa/tratamiento farmacológico , Niño , Preescolar , Femenino , Humanos , Incidencia , Lactante , Masculino , Osteomielitis/diagnóstico , Osteomielitis/tratamiento farmacológico , Estudios Retrospectivos , Infecciones por Salmonella/diagnóstico , Infecciones por Salmonella/tratamiento farmacológico , Factores Sexuales
6.
Implant Dent ; 9(3): 252-60, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11307412

RESUMEN

Problems with crestal bone resorption and bone adaptation to dental implants in compromised and weak bone present clinical challenges due to insufficient bone volume. Mathematical models have shown that a new, square-thread, dental implant design increases functional surface area and reduces shear loading at the implant interface. The aim of this investigation was to evaluate the ability of bone to grow between the threads of the new implant and its general biocompatibility in a canine model. Test implants were placed in the mandibles of four beagle dogs after posterior partial edentulism. Three months after implantation, the animals received independent fixed partial dentures, were followed for an additional 6 months, and then euthanized for histological analyses. Analyses revealed that bone grew between the threads and closely apposed the new implant design. Histological observations also revealed that the inferior aspect of the test implant threads were apposed by more bone than the coronal aspect, suggesting a biological advantage for the compressive load transfer mechanism of the new implant design. The results of this study revealed that the new implant design became osseointegrated with bone growing between the threads of the device.


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental , Animales , Materiales Biocompatibles , Resorción Ósea/fisiopatología , Materiales Biocompatibles Revestidos , Aleaciones Dentales , Implantación Dental Endoósea , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Modelos Animales de Enfermedad , Perros , Estudios de Seguimiento , Arcada Parcialmente Edéntula/cirugía , Mandíbula/diagnóstico por imagen , Mandíbula/patología , Mandíbula/cirugía , Oseointegración , Osteogénesis , Radiografía , Estrés Mecánico , Técnica de Sustracción , Propiedades de Superficie , Titanio
7.
J South Orthop Assoc ; 9(3): 207-12, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-12135304

RESUMEN

The standard practice in total joint arthroplasty has included the use of postsurgical drains to minimize perioperative wound complications, particularly infection. This practice is not without cost and potential morbidity. Our recent cemented and cementless total knee arthroplasties (TKAs) have been done without the use of postoperative surgical drains and without any appreciable increase in wound complications. To confirm this, we retrospectively reviewed 227 consecutive TKAs, specifically evaluating perioperative wound complications. No statistical increase in perioperative complications in TKAs without drains was found. A lower percentage of complications was seen in the cementless population when compared with cemented or drained knees. We suggest that surgical drainage is not required in TKA, even when cementless fixation is used.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Drenaje , Cuidados Posoperatorios , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Infección de la Herida Quirúrgica/epidemiología , Infección de la Herida Quirúrgica/prevención & control
8.
J Oral Implantol ; 25(3): 162-78; discussion 161, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10551147

RESUMEN

We report analyses obtained from 135 implant cases retrieved from humans and submitted to the American Academy of Implant Dentistry Research Foundation--Medical College of Georgia Implant Retrieval Center. The undecalcified samples were embedded in polymethyl-methacrylate and examined with scanning electron microscopy and with routine light via polarized or Nomarski microscopy. Cases included both orthopedic and dental implants as well as entire mandibles obtained at autopsy. Significant numbers of submitted implants had substantial amounts of adhered bone, which permitted evaluation of human bone remodeling to osseointegrated implants. These implants failed because of implant fracture. As has been observed in animal studies, an interdigitating canaliculi network provided communication between interfacial osteocytes and osteocytes deeper within the remodeled osteonal and trabecular bone. Significant numbers of osseointegrated fractured hydroxyapatite-coated dental implants demonstrated the adequate serviceability of these implants prior to biomaterial fracture. In contrast, the hydroxyapatite coating was dissociated from retrieved orthopedic implants, leading to extensive cup loosening and case failure. Caution is advised for the use of hydroxyapatite-coated acetabular implants. This study therefore underscores the need for evaluation of failed human dental and orthopedic implants. Correlations can be drawn between human retrieval and experimental animal studies.


Asunto(s)
Materiales Biocompatibles Revestidos/efectos adversos , Implantes Dentales , Fracaso de la Restauración Dental , Remoción de Dispositivos , Durapatita/efectos adversos , Anciano , Análisis de Falla de Equipo , Femenino , Prótesis de Cadera , Humanos , Masculino , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Oseointegración/efectos de los fármacos , Fotogrametría , Falla de Prótesis , Propiedades de Superficie
9.
Int J Oral Maxillofac Implants ; 14(4): 510-5, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10453665

RESUMEN

The purpose of this pilot study was to make a histologic and histomorphometric comparison of hydroxyapatite-(HA) coated and titanium plasma-sprayed (TPS) root-form implants that were placed in 2 mongrel dogs immediately after extraction of mandibular premolars. After 8 weeks of healing, the implant-containing segments of the mandible were removed en bloc and bone blocks including implants were sectioned. Histologic and histomorphometric analyses were performed by evaluating bone sections. The mean bone contact percentage of HA-coated implants was 61.84 +/- 7.84%, with a range of 52.09% to 75.7%, and the mean bone contact percentage of TPS implants was 51.35 +/- 12.1%, with a range of 30.1% to 70.6%. This pilot study suggests that HA-coated implants placed into fresh extraction sockets can achieve better bone contact than TPS implants, but there was evidence that the surface of the HA layer can be resorbed, so long-term stability of HA coatings in immediate implantation must be investigated.


Asunto(s)
Materiales Biocompatibles Revestidos , Implantación Dental Endoósea , Implantes Dentales , Durapatita , Mandíbula/patología , Titanio , Animales , Diente Premolar , Materiales Biocompatibles Revestidos/química , Tejido Conectivo/patología , Diseño de Prótesis Dental , Perros , Durapatita/química , Epitelio/patología , Mandíbula/cirugía , Mucosa Bucal/patología , Oseointegración , Proyectos Piloto , Propiedades de Superficie , Titanio/química , Extracción Dental , Alveolo Dental/patología , Alveolo Dental/cirugía , Cicatrización de Heridas
10.
Int J Oral Maxillofac Implants ; 14(3): 342-50, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10379107

RESUMEN

The histologic response of the periodontal tissues of teeth rigidly joined to implants with a fixed partial denture was evaluated using light microscopy. The fourth premolar of a dog was connected to implants placed in the first and second premolar position with a fixed partial denture. The restored teeth were under function for periods of 6, 12, 18, and 24 months, with unrestored fourth premolars as controls. The histology of the periodontal ligament on the fourth premolar was found to be similar in the control and the restored teeth. The periodontal tissues contained a minimal amount of inflammatory cell infiltrate. The crestal bone was cortical in nature, showing no periodontal breakdown. The orientation of the periodontal fibers was easily determined, indicating that minimal remodeling had taken place. The number and morphology of the blood vessels were also similar in the control and the treated teeth. The lack of inflammation and stability of the periodontal tissue suggested that the use of combination implant-to-natural-teeth restorations with rigid joints in this animal model does not result in deleterious effects on the periodontal tissues and that the forces placed on the tissues are within the remodeling capabilities of the teeth.


Asunto(s)
Pilares Dentales , Implantes Dentales , Dentadura Parcial Fija , Periodoncio/anatomía & histología , Animales , Diente Premolar , Implantación Dental Endoósea , Perros , Técnicas de Preparación Histocitológica , Modelos Biológicos , Evaluación de Resultado en la Atención de Salud , Ligamento Periodontal/anatomía & histología , Ligamento Periodontal/irrigación sanguínea , Periodoncio/irrigación sanguínea
11.
Adv Dent Res ; 13: 27-33, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11276743

RESUMEN

Ultrastructural examination of the morphology and morphometry of the bone supporting uncoated titanium and ceramic implants was assessed in an experimental animal model involving 120 implants placed into the mandibles of 30 adult mongrel dogs. Further, preliminary morphologic and morphometric observations of the bone supporting uncoated and hydroxylapatite-coated endosteal titanium implants was evaluated in a second investigation involving 72 implants placed into the mandibles and maxillae of 6 additional dogs. A densely mineralized collagen fiber matrix was observed directly interfacing with uncoated implants. The only material interposed between the implant and bone matrix was a 20- to 50-nm electron-dense material suggestive of a proteoglycan. Also seen in these same osseointegrated implants were narrow unmineralized zones interposed between the implant and bone matrix. In these zones of remodeling bone, numerous osteoblasts were observed interacting with the collagen fiber matrix. It was shown that a normal homeostasis of anabolic osteoblastic activity and catabolic osteoclastic activity resulted in bone remodeling and the resultant osseointegration of the implants. Hydroxylapatite-coated implants intimately interfaced with healthy bone. The mineralized matrix extended into the microporosity of the HA coating. This matrix contained viable osteocytes.


Asunto(s)
Materiales Biocompatibles/química , Materiales Biocompatibles Revestidos/química , Implantación Dental Endoósea , Implantes Dentales , Mandíbula/ultraestructura , Aleaciones , Animales , Matriz Ósea/ultraestructura , Remodelación Ósea/fisiología , Cerámica/química , Colágeno/ultraestructura , Aleaciones Dentales/química , Perros , Durapatita/química , Mandíbula/cirugía , Maxilar/cirugía , Maxilar/ultraestructura , Modelos Animales , Oseointegración/fisiología , Osteoblastos/ultraestructura , Osteoclastos/ultraestructura , Osteocitos/ultraestructura , Porosidad , Proteoglicanos/ultraestructura , Propiedades de Superficie , Titanio/química
12.
J Biomed Mater Res ; 39(4): 611-20, 1998 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-9492223

RESUMEN

This report presents transmission electron and high voltage transmission electron microscopic observations of bone and associated remodeling tissues directly interfacing with endosteal dental implants. Undecalcified interfacial tissues were serially sectioned from mandibular samples encasing 60 implants placed into 30 dogs. Two-dimensional ultrastructural analyses and three-dimensional stereology showed that osteogenesis adjacent to dental implants is a dynamic interaction of osseous cells and a collagenous fiber matrix. This study showed that the interfacial bone consists of a mineralized collagen fiber matrix associated with an inorganic (hydroxylapatite) matrix. This study suggested that an unmineralized collagen fiber matrix initially is laid down directly at the implant surface, and that this matrix then is mineralized. Osteoblasts interacted with this matrix, eventually becoming encased within developing lacunae during the remodeling process. This process formed the cellular (osteocyte) aspects of the developed bone. Osteocyte processes extended through canaliculi directly to the implant surface. Apparently, these processes also were entrapped within canaliculi during the mineralization events. At times, these processes paralleled the implant surface. The bone-implant interfacial zone was primarily fibrillar (both mineralized and unmineralized) in morphology, with an electron-dense, ruthenium positive deposition. This electron-dense material was approximately 20 to 50 nanometers in thickness, and only this thin layer separated the remodeled mineralized bone from the implant.


Asunto(s)
Materiales Biocompatibles , Huesos/ultraestructura , Implantes Dentales , Animales , Perros , Microscopía Electrónica
14.
Implant Dent ; 7(4): 338-50, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-10196811

RESUMEN

Electron microscopic observations were made from tissues apposing titanium and ceramic root form and blade implants. The tissue was serially sectioned from the most coronal epithelium, through the gingival connective tissue, to the osseous support tissues, and directly to the most apical tissue support. Of the thousands of sections analyzed for each implant, 500 micrographs were routinely viewed for each of the implants analyzed by this study. Of the 120 total implants placed in 30 adult dogs, 60 were used for electron microscopy. Osseointegrated implants were often apposed by a mineralized matrix of collagenous fibers. The dense mineralized collagen matrix was often separated from the implant by only a ruthenium positive electron dense deposit 20 to 50 nanometers thick. Areas of the same implant were also apposed by an unmineralized collagen fiber stroma, which ranged in thickness, that contained osteoblasts. Interaction of the osteoblasts and the unmineralized collagen fibers resulted in the mineralization events of osteogenesis. Also apposing other areas of the same integrated implants were lacunar areas containing osteoclasts and vessels. These zones were similar to Howship's Lacunae. These results demonstrated that a normal homeostasis of catabolic osteoclastic activity and metabolic osteoblastic activity resulted in a dynamic implant-tissue interface. This biocompatible and dynamic support complex provides a construct for the long-term clinical serviceability of osseointegrated implants.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Oseointegración , Proceso Alveolar/anatomía & histología , Proceso Alveolar/fisiología , Animales , Implantación de Cuchilla (Odontología) , Adhesión Celular , Cerámica , Colágeno , Perros , Ensayo de Materiales , Microscopía Electrónica , Osteoblastos/fisiología , Osteoclastos/fisiología , Osteogénesis , Propiedades de Superficie , Titanio
15.
Int J Oral Maxillofac Implants ; 12(4): 443-53, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9274073

RESUMEN

Correlated transmission electron and high-voltage electron microscopic analyses examined the undecalcified bone and associated support tissues of 60 endosseous titanium blade and titanium and ceramic root-form implants in dogs. The implants supported fixed partial dentures for up to 2 years. Data obtained from this investigation suggest that a range of tissues, both mineralized and unmineralized, support osseointegrated dental implants. This study examined the tissues apposing not just isolated aspects of the implant surface, but the entire length of the implant, and found that mineralized and unmineralized tissues existed concurrently. Much of the implant surface was apposed by mandibular bone, and both root-form and blade implants osseointegrated. The densely mineralized collagen fibril matrix was often separated from the implant by only a 20-nm to 50-nm electron-dense, ruthenium-positive deposit. High-voltage electron microscope stereology demonstrated that cellular processes extended directly to the implant from underlying osteocytes. In the same implants, areas containing an unmineralized collagen matrix interposed between the bone and implant surface were observed. In this region osteoblasts interacted with this matrix, and Howship's lacunae, containing vascular elements and osteoclasts, were also observed. The remodeling activities appear to be a homeostasis of catabolic activity (osteoclasts) and metabolic activity (osteoblasts). The apex of the implant was often apposed by a fibrofatty stroma. The support tissue response appears to be the result of the interrelations of osteoblasts, osteocytes, and osteoclasts in association with vascular elements. Therefore, the support tissue response to osseointegrated implants is a dynamic activity that involves the healthy interaction of these cells and tissues along the entire length of the implant.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Mandíbula/ultraestructura , Oseointegración , Periodoncio/ultraestructura , Tejido Adiposo/ultraestructura , Animales , Implantación de Cuchilla (Odontología)/instrumentación , Remodelación Ósea , Cerámica , Colágeno/ultraestructura , Colorantes , Tejido Conectivo/ultraestructura , Pilares Dentales , Implantación Dental Endoósea/instrumentación , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Perros , Estudios de Seguimiento , Homeostasis , Mandíbula/irrigación sanguínea , Mandíbula/cirugía , Microscopía Electrónica , Osteoblastos/ultraestructura , Osteoclastos/ultraestructura , Osteocitos/ultraestructura , Periodoncio/cirugía , Rutenio , Propiedades de Superficie , Titanio , Raíz del Diente
16.
Int J Oral Maxillofac Implants ; 11(1): 15-25, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8820118

RESUMEN

One hundred twenty titanium and ceramic root-form and titanium blade implants were placed into 30 dog mandibles. Twenty-four implants in six control dogs (in situ for 5 months) did not receive prostheses. Ninety-six implants in 24 dogs supported prostheses for 6, 12, 18, or 24 months. Computerized morphometry data presented the percent of the implant surface apposed directly by bone. A three-way factorial analysis of variance was used to assess significance. Individual implant means ranged from 0% (mobile implant) to 71% bone adaptation. From these data, two-stage titanium root-form implants were shown to be apposed by more bone than the other five systems, and overall, titanium implant systems were apposed by more bone than ceramic systems. Between 41% and 50% of the surface of integrated ceramic implants were apposed by bone, whereas between 50% and 65% of the surfaces of titanium implants were apposed by bone. Also, two-stage surgery for blade implants appears important for implant success. Furthermore, the use of Nomarski differential illumination appears to be useful for examining the quality of interfacial bone to correlate with the amount of bone quantified by morphometric protocols.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Mandíbula/anatomía & histología , Mandíbula/cirugía , Oseointegración , Análisis de Varianza , Animales , Implantación de Cuchilla (Odontología) , Cerámica , Pilares Dentales , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Perros , Osteón/anatomía & histología , Procesamiento de Imagen Asistido por Computador , Falla de Prótesis , Propiedades de Superficie , Titanio , Raíz del Diente
17.
J Periodontol ; 66(3): 184-90, 1995 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-7776162

RESUMEN

The purpose of this study was to locate the position of the periodontal probe tip using a pressure of 126 N/cm2 (force of 0.30N using a round periodontal probe tip with a diameter of 0.55 mm). The influence of gingival inflammation on this position was also studied. Subjects with three levels of periodontal health and disease were entered into the study and each contributed one experimental tooth. At each site a standardized probing system was used to place a probe into a clinical pocket. The probe tip was luted to the test tooth surface. The tooth with its gingival tissue and probe tip was extracted, fixed, and processed for histological measurements. Distances in mm were obtained from the cemento-enamel junction (CEJ) to the probe tip, to the base of the crevice/pocket, and to the most coronal connective tissue attachment. Analysis of the data indicated that clinical inflammation was not a factor in the placement of the probe tip at crevice/pocket's landmarks relative to the CEJ; however variability of probing may have caused the non-significance. The probing system placed the probe tip 0.66 mm apical to the base of the crevice/pocket and 0.06 mm coronal to the most coronal connective tissue attachment. These conclusions corroborated the results of the previous study in dogs which predicted probe placement of 0.44 mm apical to the base of the crevice using the standardized pressure of this probing system.


Asunto(s)
Instrumentos Dentales/normas , Enfermedades Periodontales/diagnóstico , Periodoncia/instrumentación , Análisis de Varianza , Diagnóstico Bucal/instrumentación , Femenino , Gingivitis/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Bolsa Periodontal/diagnóstico , Presión
18.
J Oral Implantol ; 21(2): 116-20, 1995.
Artículo en Inglés | MEDLINE | ID: mdl-8699502

RESUMEN

Calcium channel-blocking agents are used extensively for the management of cardiovascular conditions, including angina pectoris, coronary artery spasm, cardiac arrhythmias, and hypertension. Gingival overgrowth around natural teeth has been previously reported in the literature with patients taking calcium channel-blocking agents. This clinical report describes hyperplasia of tissues around titanium dental implants in a patient taking Nifedipine along with the multiphasic approach to treating this medication-induced hyperplasia of the peri-implant tissues.


Asunto(s)
Bloqueadores de los Canales de Calcio/efectos adversos , Implantes Dentales/efectos adversos , Hiperplasia Gingival/inducido químicamente , Nifedipino/efectos adversos , Animales , Gatos , Atención Dental para Enfermos Crónicos , Femenino , Hiperplasia Gingival/terapia , Humanos , Hipertensión/tratamiento farmacológico
19.
J Oral Implantol ; 21(2): 96-106, 1995.
Artículo en Inglés | MEDLINE | ID: mdl-8699510

RESUMEN

To examine bone morphology associated with endosteal dental implants at various time intervals, we inserted 20 one-stage and 20 two-stage titanium blade implants and 20 one-stage and 20 two-stage titanium root-form implants into 30 dog mandibles. Sixteen implants in 6 control (c) dogs (in situ five months) did not receive bridgework. Sixty-four implants in 24 dogs supported bridges for six, 12, 18, or 24 months. The entire area of the mandible containing the implants was examined by routine light and Nomarski differential interference microscopy (NM) for bone morphology (including osteon orientation) at the implant surface and at regions away from the implant. Control root-form implants were apposed by woven bone, with homogenous compact bone in the cortical plate distant to the implant. After 6 mo of load, immature bone was predominant apposing the implant, but initial osteonal maturation was apparent. NM clearly demonstrated the interstitial and concentric lamellae of the bone. Surprisingly, compact bone formed internal to the cortical plate, an area where trabecular bone is expected. At later periods of load, more mature osteons were seen apposing the implants; however remodeling events were still apparent. These remodeling events extend further away from the implant than was expected if the events resulted only from surgical repair. Also, when the implant inclined so that half was totally in the cortical plate and half in the marrow (in trabecular patterns), osteonal bone appeared to remodel in both areas. Control blade implants and blades loaded for six months were apposed by immature osteons when the implant was placed into the cortical plate. A trabecular meshwork was inferior to the osteonal bone. At 12 mo of load, the bone internal to the cortical plate appeared similar to the lamina dura supporting teeth; however, no PDL existed; the lamina-dura-like pattern directly apposed the implant. Even after 24 mo of load, extensive bone remodeling was apparent adjacent to the implant, markedly different from the bone making up the existing cortical plate. From these data, remodeling activities to blade implants may involve the development of a lamina-dura-like bone morphology after longer periods of load. Osteonal bone was apparent, but only at regions where the implant was inserted into the cortical plate. Further, bone remodeling was apparent even after long periods of load.


Asunto(s)
Proceso Alveolar/fisiología , Remodelación Ósea/fisiología , Implantación Dental Endoósea , Implantes Dentales , Oseointegración/fisiología , Proceso Alveolar/anatomía & histología , Animales , Implantación de Cuchilla (Odontología)/métodos , Implantación Dental Endoósea/métodos , Diseño de Prótesis Dental , Perros , Osteón/anatomía & histología , Osteón/fisiología , Microscopía de Interferencia/métodos , Osteogénesis/fisiología , Estrés Mecánico , Factores de Tiempo , Soporte de Peso , Cicatrización de Heridas/fisiología
20.
J Oral Implantol ; 21(1): 8-18, 1995.
Artículo en Inglés | MEDLINE | ID: mdl-7473873

RESUMEN

This study conducted a longitudinal prospective clinical study of the single-crystal sapphire (Al2O3) cylindrical screw-shaped endosteal dental implant, and attempted to establish clinical parameters to evaluate implant success or failure. Twenty-eight mandibular implants (17 patients) were placed. After six weeks' healing, 23 implants in 15 patients served as distal abutments for fixed prostheses (baseline). Implants were evaluated for bleeding index, crevicular fluid volume index, plaque accumulation index, radiographic index, mobility index, and patient comfort. Any implant failing in three of these criteria or implants removed were judged as failures. After 10 years, of the 21 baseline implants recalled (two implants were lost to recall), 17 were fully functional, for an 81% success rate. The use of qualitative and quantitative clinical evaluation parameters as utilized in this study appears to be important and useful in assessments of the clinical serviceability of dental implants. These parameters can be used in human clinical trials as well as in experimental animal studies.


Asunto(s)
Óxido de Aluminio , Implantación Dental Endoósea , Implantes Dentales , Análisis de Varianza , Cerámica , Ensayos Clínicos como Asunto/normas , Índice de Placa Dental , Diseño de Prótesis Dental , Retención de Prótesis Dentales , Dentadura Parcial Fija , Líquido del Surco Gingival/metabolismo , Humanos , Estudios Longitudinales , Índice Periodontal , Estudios Prospectivos , Falla de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...