Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Nanomaterials (Basel) ; 13(24)2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38133035

RESUMEN

This study reports the development of a novel amphiphobic coating. The coating is a bilayer arrangement, where carbon nanotubes (CNTs) form the underlayer and fluorinated alkyl-silane (FAS) forms the overlayer, resulting in the development of highly amphiphobic coatings suitable for a wide range of substrates. The effectiveness of these coatings is demonstrated through enhanced contact angles for water and artificial blood plasma fluid on glass, stainless steel, and porous PTFE. The coatings were characterized using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), atomic force microscopy (AFM), and contact angle (CA) measurements. The water contact angles achieved with the bilayer coating were 106 ± 2°, 116 ± 2°, and 141 ± 2° for glass, stainless steel, and PTFE, respectively, confirming the hydrophobic nature of the coating. Additionally, the coating displayed high repellency for blood plasma, exhibiting contact angles of 102 ± 2°, 112 ± 2°, and 134 ± 2° on coated glass, stainless steel, and PTFE surfaces, respectively. The presence of the CNT underlayer improved plasma contact angles by 29%, 21.7%, and 16.5% for the respective surfaces. The presence of the CNT layer improved surface roughness significantly, and the average roughness of the bilayer coating on glass, stainless steel, and PTFE was measured to be 488 nm, 301 nm, and 274 nm, respectively. Mechanistically, the CNT underlayer contributed to the surface roughness, while the FAS layer provided high amphiphobicity. The maximum effect was observed on modified glass, followed by stainless steel and PTFE surfaces. These findings highlight the promising potential of this coating method across diverse applications, particularly in the biomedical industry, where it can help mitigate complications associated with device-fluid interactions.

2.
Innovations (Phila) ; 18(6): 557-564, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37968874

RESUMEN

OBJECTIVE: Preoperative left ventricular ejection fraction (LVEF) is one of the main predictors of outcomes in cardiac surgery. We present current era outcomes and associated direct cost in nonemergent isolated coronary artery bypass surgery (CABG) patients with LVEF <20% over the past 6 years and compare it with higher EF subgroups. METHODS: Six-year data from 2016 to 2022 at hospitals sharing Society of Thoracic Surgeons and financial data with Biome Analytics were analyzed based on 3 EF subgroups (EF ≤20%, EF 21% to 35%, and EF >35%). Outcomes and costs were assessed. RESULTS: Overall 30-day mortality of 12,649 patients was 1.9%. The EF ≤20% (n = 248), EF 21% to 35% (n = 1,408), and EF >35 (n = 10,993) cohorts had mortality of 6.9%, 3.7%, and 1.6%, respectively. The EF ≤20% subgroup had higher use of cardiopulmonary bypass, blood products, and mechanical support. In addition, the EF ≤20% subgroup had higher complication rates in almost all measured categories. Also, the EF ≤20% cohort had significantly higher length of stay, intensive care unit (ICU) hours, ICU and hospital readmissions, and lowest discharge to home rate. The strongest factors associated with mortality were postoperative cardiac arrest, renal failure requiring dialysis, extracorporeal membrane oxygenation, sepsis, prolonged ventilation, and gastrointestinal event. The overall median direct cost of care was $37,387.79 ($27,605.18, $51,720.96), with a median direct cost of care in the EF ≤20%, EF 21% to 35%, and EF >35% subgroups of $52,500.17 ($34,103.52, $80,806.79), $44,108.32 ($31,597.58, $63,788.03), and $36,521.80 ($27,168.91, $50,019.31), respectively. CONCLUSIONS: In nonemergent isolated CABG surgery, low EF continues to have higher surgical risks and higher direct cost of care despite advances in cardiovascular care.


Asunto(s)
Puente de Arteria Coronaria , Función Ventricular Izquierda , Humanos , Volumen Sistólico , Puente de Arteria Coronaria/efectos adversos , Estudios Retrospectivos
5.
Health Sci Rep ; 5(6): e869, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36381416

RESUMEN

Transcatheter pacing systems are self-contained, leadless, devices that offer the potential benefits of avoiding complications related to pectoral pocket and upper extremity vascular access. These systems in preapproval trials demonstrated excellent safety profile with the incidence of device-related cardiac perforation as low as 1.6% with Micra™ (Medtronic) and 1.3% in Nanostim (Abbott). In post-approval registry of Micra™ TPS, the rate of major complications was even lower than in the investigational study ranging from 0.63% to 0.77%. Recently, published report found much higher rates of need for rescue surgery, shock, tamponade, and death among patients implanted with the Micra™ device when compared with transvenous devices. This case report describes two cases of major right ventricular perforation requiring surgical intervention.

6.
ASAIO J ; 68(12): 1428-1433, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35671537

RESUMEN

Anticoagulation during extracorporeal membrane oxygenation (ECMO) for Coronovirus Disease 2019 (COVID-19) can be performed by direct or indirect thrombin inhibitors but differences in outcomes with these agents are uncertain. A retrospective, multicenter study was conducted. All consecutive adult patients with COVID-19 placed on ECMO between March 1, 2020 and April 30, 2021 in participating centers, were included. Patients were divided in groups receiving either a direct thrombin inhibitor (DTI) or an indirect thrombin inhibitor such as unfractionated heparin (UFH). Overall, 455 patients with COVID-19 from 17 centers were placed on ECMO during the study period. Forty-four patients did not receive anticoagulation. Of the remaining 411 patients, DTI was used in 160 (39%) whereas 251 (61%) received UFH. At 90-days, in-hospital mortality was 50% (DTI) and 61% (UFH), adjusted hazard ratio: 0.81, 95% confidence interval (CI): 0.49-1.32. Deep vein thrombosis [adjusted odds ratio (aOR): 2.60, 95% CI: 0.90-6.65], ischemic (aOR: 1.58, 95% CI: 0.18-14.0), and hemorrhagic (aOR:1.22, 95% CI: 0.39-3.87) stroke were similar with DTI in comparison to UFH. Bleeding requiring transfusion was lower in patients receiving DTI (aOR: 0.40, 95% CI: 0.18-0.87). Anticoagulants that directly inhibit thrombin are associated with similar in-hospital mortality, stroke, and venous thrombosis and do not confer a higher risk of clinical bleeding in comparison to conventional heparin during ECMO for COVID-19.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Accidente Cerebrovascular , Adulto , Humanos , Heparina/uso terapéutico , Oxigenación por Membrana Extracorpórea/efectos adversos , Trombina , Estudios Retrospectivos , COVID-19/terapia , Anticoagulantes/uso terapéutico , Hemorragia/etiología
7.
Polymers (Basel) ; 14(6)2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35335407

RESUMEN

Superhydrophobic surfaces, as indicated in the name, are highly hydrophobic and readily repel water. With contact angles greater than 150° and sliding angles less than 10°, water droplets flow easily and hardly wet these surfaces. Superhydrophobic materials and coatings have been drawing increasing attention in medical fields, especially on account of their promising applications in blood-contacting devices. Superhydrophobicity controls the interactions of cells with the surfaces and facilitates the flowing of blood or plasma without damaging blood cells. The antibiofouling effect of superhydrophobic surfaces resists adhesion of organic substances, including blood components and microorganisms. These attributes are critical to medical applications such as filter membranes, prosthetic heart valves, extracorporeal circuit tubing, and indwelling catheters. Researchers have developed various methods to fabricate blood-compatible or biocompatible superhydrophobic surfaces using different materials. In addition to being hydrophobic, these surfaces can also be antihemolytic, antithrombotic, antibacterial, and antibiofouling, making them ideal for clinical applications. In this review, the authors summarize recent developments of blood-compatible superhydrophobic surfaces, with a focus on methods and materials. The expectation of this review is that it will support the biomedical research field by providing current trends as well as future directions.

8.
Artif Organs ; 46(8): 1659-1668, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35191553

RESUMEN

In a multicenter, retrospective analysis of 435 patients with refractory COVID-19 placed on V-V ECMO, cannulation by a single, dual-lumen catheter with directed outflow to the pulmonary artery was associated with lower inpatient mortality.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , COVID-19/terapia , Cateterismo/métodos , Catéteres , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Humanos , Estudios Retrospectivos
10.
J Thorac Cardiovasc Surg ; 164(5): 1398-1399, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-33419560
13.
Semin Thorac Cardiovasc Surg ; 33(3): 637-638, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33609670
14.
JTCVS Open ; 7: 10-11, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36003747
16.
J Thorac Cardiovasc Surg ; 162(1): 38-39, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-32008762

Asunto(s)
Stents , Humanos
17.
20.
J Thorac Dis ; 11(4): 1428-1432, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31179085

RESUMEN

BACKGROUND: With the advent of minimally invasive techniques, the standard approaches to many surgeries have changed. We compared the financial costs and health care outcomes between standard thymectomy via sternotomy and video assisted thoracoscopic surgery (VATS). METHODS: A 3-year review [2010-2012] of the National Inpatient Sample (NIS) was performed. All patients undergoing thymectomy were included. Patients undergoing VATS thymectomy were identified. Outcomes measured were hospital length of stay (LOS), hospital charges, and mortality. Univariate and multivariate analyses were performed to control for demographics and comorbidities. RESULTS: The results of 2,065 patients who underwent thymectomy were analyzed, of which 373 (18.1%) had VATS thymectomy and 1,692 (81.9%) had standard thymectomy. Mean age was 52.8±16, 42.5% were male, and 65.5% were Caucasian. There was a significant interval increase in number of patients undergoing VATS thymectomy (10% in 2010 vs. 19.2% in 2012, P<0.001). Patients undergoing standard thymectomy had longer hospital LOS (6.8±6.6 vs. 3.3d±3.4 d, P<0.001), hospital charges $88,838±$120,892 vs. $57,251±$54,929) and hospital mortality (0.9% vs. 0%, P=0.01). In multivariate analysis, thymectomy via sternotomy was independently associated with increased hospital LOS B =1.6 d, P<0.001) and charges (B = $13,041, P=0.041). CONCLUSIONS: Our study demonstrates decreased hospital length of stay and reduced hospital charges in patients undergoing VATS thymectomy compared to standard thymectomy. Our data demonstrates that the prevalence of VATS thymectomies is increasing, likely related to improved healthcare and financial outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...