Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur J Radiol ; 177: 111595, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38970994

RESUMEN

PURPOSE: CT perfusion (CTP) is a valuable tool in suspected acute ischemic stroke. A substantial variability of the delay between contrast injection and bolus arrival in the brain is conceivable. We investigated the distribution of the peak positions of the concentration time curves measured in an artery (arterial input function, AIF) and - in cases with ischemia - also measured in the penumbra. METHODS: We report on 2624 perfusion scans (52 % female, mean age 72.2 ± 14.4 years) with stroke present in 1636 cases. From the attenuation time curves of the AIF and the penumbra, we calculated the respective bolus peak positions and investigated the distribution of the peak positions. Further, we analyzed the bolus peak positions for associations with age. RESULTS: The bolus peaked significantly later in older patients, both in the AIF and in the penumbra (all p < 0.001). In the whole cohort, we found a significant association of age with the bolus peak position of the AIF (ρ = 0.334; p < 0.001). In patients with stroke, age was also associated to the peak position of the AIF (ρ = 0.305; p < 0.001), and the penumbra (ρ = 0.246, p < 0.001). However, a substantial range of peak positions of the AIF and penumbra was noted across all age ranges. CONCLUSIONS: This study revealed a strong age-dependency of the contrast bolus arrival in both healthy and ischemic tissue. This variability makes non-uniform sampling schemes, which have been suggested to reduce radiation dose, problematic, as they might not always optimally capture the bolus in all cases.


Asunto(s)
Medios de Contraste , Humanos , Femenino , Masculino , Anciano , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Factores de Edad , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios de Cohortes , Accidente Cerebrovascular/diagnóstico por imagen
2.
Radiol Med ; 129(6): 890-900, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38689182

RESUMEN

PURPOSE: Artifacts caused by metallic implants remain a challenge in computed tomography (CT). We investigated the impact of photon-counting detector computed tomography (PCD-CT) for artifact reduction in patients with orthopedic implants with respect to image quality and diagnostic confidence using different artifact reduction approaches. MATERIAL AND METHODS: In this prospective study, consecutive patients with orthopedic implants underwent PCD-CT imaging of the implant area. Four series were reconstructed for each patient (clinical standard reconstruction [PCD-CTStd], monoenergetic images at 140 keV [PCD-CT140keV], iterative metal artifact reduction (iMAR) corrected [PCD-CTiMAR], combination of iMAR and 140 keV monoenergetic [PCD-CT140keV+iMAR]). Subsequently, three radiologists evaluated the reconstructions in a random and blinded manner for image quality, artifact severity, anatomy delineation (adjacent and distant), and diagnostic confidence using a 5-point Likert scale (5 = excellent). In addition, the coefficient of variation [CV] and the relative quantitative artifact reduction potential were obtained as objective measures. RESULTS: We enrolled 39 patients with a mean age of 67.3 ± 13.2 years (51%; n = 20 male) and a mean BMI of 26.1 ± 4 kg/m2. All image quality measures and diagnostic confidence were significantly higher for the iMAR vs. non-iMAR reconstructions (all p < 0.001). No significant effect of the different artifact reduction approaches on CV was observed (p = 0.26). The quantitative analysis indicated the most effective artifact reduction for the iMAR reconstructions, which was higher than PCD-CT140keV (p < 0.001). CONCLUSION: PCD-CT allows for effective metal artifact reduction in patients with orthopedic implants, resulting in superior image quality and diagnostic confidence with the potential to improve patient management and clinical decision making.


Asunto(s)
Artefactos , Metales , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Anciano , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Persona de Mediana Edad , Prótesis e Implantes , Anciano de 80 o más Años , Fotones , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
3.
Neuroradiology ; 66(5): 749-759, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38498208

RESUMEN

PURPOSE: CT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke. METHODS: We retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared. RESULTS: The agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4. CONCLUSION: Reducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular , Humanos , Estudios Retrospectivos , Reducción Gradual de Medicamentos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/terapia , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Tomografía Computarizada por Rayos X/métodos , Isquemia Encefálica/terapia , Perfusión , Imagen de Perfusión/métodos
4.
Radiol Med ; 129(5): 669-676, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38512614

RESUMEN

PURPOSE: To investigate the value of photon-counting detector CT (PCD-CT) derived virtual non-contrast (VNC) reconstructions to identify renal cysts in comparison with conventional dual-energy integrating detector (DE EID) CT-derived VNC reconstructions. MATERIAL AND METHODS: We prospectively enrolled consecutive patients with simple renal cysts (Bosniak classification-Version 2019, density ≤ 20 HU and/or enhancement ≤ 20 HU) who underwent multiphase (non-contrast, arterial, portal venous phase) PCD-CT and for whom non-contrast and portal venous phase DE EID-CT was available. Subsequently, VNC reconstructions were calculated for all contrast phases and density as well as contrast enhancement within the cysts were measured and compared. MRI and/or ultrasound served as reference standards for lesion classification. RESULTS: 19 patients (1 cyst per patient; age 69.5 ± 10.7 years; 17 [89.5%] male) were included. Density measurements on PCD-CT non-contrast and VNC reconstructions (arterial and portal venous phase) revealed no significant effect on HU values (p = 0.301). In contrast, a significant difference between non-contrast vs. VNC images was found for DE EID-CT (p = 0.02). For PCD-CT, enhancement for VNC reconstructions was < 20 HU for all evaluated cysts. DE EID-CT measurements revealed an enhancement of > 20 HU in five lesions (26.3%) using the VNC reconstructions, which was not seen with the non-contrast images. CONCLUSION: PCD-CT-derived VNC images allow for reliable and accurate characterization of simple cystic renal lesions similar to non-contrast scans whereas VNC images calculated from DE EID-CT resulted in substantial false characterization. Thus, PCD-CT-derived VNC images may substitute for non-contrast images and reduce radiation dose and follow-up imaging.


Asunto(s)
Enfermedades Renales Quísticas , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Anciano , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Renales Quísticas/diagnóstico por imagen , Persona de Mediana Edad , Fotones , Anciano de 80 o más Años , Imagen Radiográfica por Emisión de Doble Fotón/métodos
5.
Ann Phys Rehabil Med ; 67(4): 101827, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38479249

RESUMEN

BACKGROUND: At the completion of formal rehabilitation after anterior cruciate ligament reconstruction, functional capacity is only restored in a small proportion of affected individuals. Therefore, the end of formal rehabilitation is not the end of functional rehabilitation. OBJECTIVE: To compare adherence to and effectiveness of a late-stage rehabilitation programme with usual care after anterior cruciate ligament (ACL) reconstruction. METHODS: This prospective, double-blind, multicentre, parallel group, randomised controlled trial, included people aged 18 to 35 years after formal rehabilitation completion (mean [SD] 241 [92] days post-reconstruction). Participants were block-randomised to a 5-month neuromuscular performance intervention (Stop-X group) or usual care (medically prescribed standard physiotherapy, individual formal rehabilitation, home-exercises). All outcomes were measured once/month. Primary outcome was the normalised knee separation distance on landing after drop jump. Baseline-adjusted linear mixed models were calculated. RESULTS: In total, 112 participants (Stop-X: 57; Usual care: 55,) were analysed. Initially, mean (SD) intervention frequency (units/week) was higher in the Stop-X than the Usual care group: 2.65 (0.96) versus 2.48 (1.14) units/week in the first and 2.28 (1.02) versus 2.14 (1.31) units/week in the second month. No between-group*time(*baseline)-differences were found for the primary outcome. Between-group*time-effects favoured the Stop-X-group at 2 months (fewer self-reported knee problems during sport, KOOS-SPORT) (estimate = 64.3, 95 % CI 24.4-104.3 for the Stop-X), more confidence to return to sport (ACL-RSI) (62.4, 10.7-114.2), fewer pain-associated knee problems (KOOS-PAIN) (82.8, 36.0-129.6), improved everyday activity abilities (KOOS-ADL) (71.1, 6.4-135.7), and improved limb symmetry index in the front hop for distance at 3 and 4 months (0.34, 0.10-0.57; 0.31, 0.08-0.54). No between-group*time-effects occurred for kinesiophobia, symptom-associated knee problems or balance hops performance. At the end of the intervention, 79 % of the Stop-X and 70 % of the Usual care participants (p < 0.05) had successfully returned to their pre-injury sport type and level. CONCLUSIONS: The Stop-X intervention was slightly superior to usual care as part of late-stage rehabilitation after ACL-reconstruction. The small benefit might justify its use after formal rehabilitation completion.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Humanos , Reconstrucción del Ligamento Cruzado Anterior/rehabilitación , Masculino , Femenino , Adulto , Método Doble Ciego , Adulto Joven , Estudios Prospectivos , Adolescente , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/rehabilitación , Resultado del Tratamiento , Terapia por Ejercicio/métodos , Modalidades de Fisioterapia , Recuperación de la Función
6.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 223-234, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38293720

RESUMEN

PURPOSE: The aim of this consensus project was to give recommendations regarding surgical treatment of the anterior cruciate ligament (ACL) injured patient. METHODS: For this consensus process, an expert, steering and rating group was formed. In an initial online meeting, the steering group, together with the expert group, formed various key topic complexes for which multiple questions were formulated. For each key topic, a structured literature search was performed by the steering group. The results of the literature review were sent to the rating group with the option to give anonymous comments until a final consensus voting was performed. Sufficient consensus was defined as 80% agreement. RESULTS: During this consensus process, 30 topics regarding the surgical management and technique of ACL reconstruction were identified. The literature search for each key question resulted in 30 final statements. Of these 30 final statements, all achieved consensus. CONCLUSIONS: This consensus process has shown that surgical treatment of ACL injury is a complex process. Various surgical factors influence patient outcomes. The proposed treatment algorithm can be used as a decision aid for the surgeon. LEVEL OF EVIDENCE: Level V.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Humanos , Algoritmos , Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Consenso
7.
Clin Pract ; 14(1): 132-147, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38248435

RESUMEN

BACKGROUND: Cardiovascular diseases and arrhythmias are medical conditions that increase with age and are associated with significant morbidities and mortality. The aim of the present study was to investigate the prevalence of arrhythmias and clinical associations in the collective of older adults receiving comprehensive geriatric care (CGC). METHODS: Holter ECG monitoring (HECG) of older patients hospitalized for CGC was analyzed. The prevalence of arrhythmias and the associations between the presence of arrhythmias, patients' characteristics and the functional status regarding basic activities of daily living (assessed by the Barthel index (BI)), walking ability (assessed by the timed up and go test (TUG)), and balance and gait (assessed by the Tinetti balance and gait test (TBGT)) were examined. RESULTS: In the presented study, 626 patients were included (mean age: 83.9 ± 6.6 years, 67.7% were female). The most common arrhythmias detected in HECG were premature ventricular contractions (87.2%), premature atrial contractions (71.7%), and atrial fibrillation (22.7%). Atrial flutter was found in 1.0%, paroxysmal supraventricular tachycardia in 5.8%, non-sustained ventricular tachycardia in 12.5%, first-degree AV block in 0.8%, second-degree AV block type Mobitz I in 0.8%, second-degree AV block type Mobitz II in 0.3%, pause > 2.5 s any cause in 3.5%, and pause > 3 s any cause in 1.6% of the cases. Premature atrial contractions were associated with the female sex (74.8% vs. 65.3%, p = 0.018), whereas in male patients, the following arrhythmias were more common: premature ventricular contractions (91.6% vs. 85.1%, p = 0.029), ventricular bigeminus (8.4% vs. 3.8%, p = 0.021), and non-sustained ventricular tachycardia (17.3% vs. 10.1%, p = 0.014). Atrial fibrillation detected in HECG was more frequent in patients at high risk of falls, indicated by their TBGT score ≤ 18 (24.7% vs. 12.0%, p = 0.006), and premature ventricular contractions were more common in patients unable to walk (TUG score 5) compared to those with largely independent mobility (TUG score 1 or 2) (88.0% vs. 75.0%, p = 0.023). In a logistic regression analysis, atrial fibrillation detected in HECG was identified as a risk factor for a high risk of falls (odds ratio (OR): 2.35, 95% confidence interval (CI): 1.23-4.46). CONCLUSION: In our study, investigation of HECG of older adults hospitalized for CGC revealed that premature atrial contractions, premature ventricular contractions, and atrial fibrillation were the most common arrhythmias. Premature atrial contractions were found to be more frequent in female patients, while male patients were more prone to premature ventricular contractions. In the investigated population, atrial fibrillation emerged as a risk factor associated with a high risk of falls.

8.
J Sport Rehabil ; 33(2): 88-98, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38176405

RESUMEN

OBJECTIVE: To rate athletes' functional ability and return to sport (RTS) success at the end of their individual, formal, medically prescribed rehabilitation after anterior anterior cruciate ligament (ACL) reconstruction. METHODS: In our prospective multicenter cohort study, 88 (42 females) adults aged 18-35 years after acute unilateral ACL rupture and subsequent hamstring grafting were included. All patients were prospectively monitored during their rehabilitation and RTS process until the end of their formal rehabilitation and RTS release. As outcome measures, functional hop and jump tests (front hop, balance hops, and drop jump screening test) and self-report outcomes (Knee Injury and Osteoarthritis Outcome Score, ACL-RTS after injury) were assessed. Literature-based cut-off values were selected to rate each performance as fulfilled or not. RESULTS: At 7.5 months (SD 2.3 months) after surgery, the percentage of participants meeting the functional thresholds ranged from 4% (Knee Injury and Osteoarthritis Outcome Score SPORT) and over 44% (ACL-RTS after injury sum score) to 59% (Knee Injury and Osteoarthritis Outcome Score activities of all daily living) in the self-report and from 29% (Balance side hop) to 69% (normalized knee separation distance) in performance testing. Only 4% fulfilled all the cut-offs, while 45% returned to the same type and level of sport. Participants who successfully returned to their previous sport (type and level) were more likely to be "over-cut-off-performers." CONCLUSIONS: The low share of the athletes who fulfilled the functional RTS criteria highlights the importance of continuing the rehabilitation measures after the formal completion to assess the need for and success of, inter alia, secondary-preventive therapies.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Traumatismos de la Rodilla , Osteoartritis , Adulto , Femenino , Humanos , Estudios de Cohortes , Estudios Prospectivos , Recuperación de la Función , Músculo Cuádriceps , Lesiones del Ligamento Cruzado Anterior/cirugía , Volver al Deporte , Traumatismos de la Rodilla/cirugía , Reconstrucción del Ligamento Cruzado Anterior/rehabilitación , Osteoartritis/cirugía
9.
Z Med Phys ; 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-38104007

RESUMEN

OBJECTIVES: Despite their life-saving capabilities, cerebrospinal fluid (CSF) shunts exhibit high failure rates, with a large fraction of failures attributed to the regulating valve. Due to a lack of methods for the detailed analysis of valve malfunctions, failure mechanisms are not well understood, and valves often have to be surgically explanted on the mere suspicion of malfunction. The presented pilot study aims to demonstrate radiological methods for comprehensive analysis of CSF shunt valves, considering both the potential for failure analysis in design optimization, and for future clinical in-vivo application to reduce the number of required shunt revision surgeries. The proposed method could also be utilized to develop and support in situ repair methods (e.g. by lysis or ultrasound) of malfunctioning CSF shunt valves. MATERIALS AND METHODS: The primary methods described are contrast-enhanced radiographic time series of CSF shunt valves, taken in a favorable projection geometry at low radiation dose, and the machine-learning-based diagnosis of CSF shunt valve obstructions. Complimentarily, we investigate CT-based methods capable of providing accurate ground truth for the training of such diagnostic tools. Using simulated test and training data, the performance of the machine-learning diagnostics in identifying and localizing obstructions within a shunt valve is evaluated regarding per-pixel sensitivity and specificity, the Dice similarity coefficient, and the false positive rate in the case of obstruction free test samples. RESULTS: Contrast enhanced subtraction radiography allows high-resolution, time-resolved, low-dose analysis of fluid transport in CSF shunt valves. Complementarily, photon-counting micro-CT allows to investigate valve obstruction mechanisms in detail, and to generate valid ground truth for machine learning-based diagnostics. Machine-learning-based detection of valve obstructions in simulated radiographies shows promising results, with a per-pixel sensitivity >70%, per-pixel specificity >90%, a median Dice coefficient >0.8 and <10% false positives at a detection threshold of 0.5. CONCLUSIONS: This ex-vivo study demonstrates obstruction detection in cerebro-spinal fluid shunt valves, combining radiological methods with machine learning under conditions compatible to future in-vivo application. Results indicate that high-resolution contrast-enhanced subtraction radiography, possibly including time-series data, combined with machine-learning image analysis, has the potential to strongly improve the diagnostics of CSF shunt valve failures. The presented method is in principle suitable for in-vivo application, considering both measurement geometry and radiological dose. Further research is needed to validate these results on real-world data and to refine the employed methods. In combination, the presented methods enable comprehensive analysis of valve failure mechanisms, paving the way for improved product development and clinical diagnostics of CSF shunt valves.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA