Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38661602

RESUMEN

BACKGROUND: Postoperative atrial fibrillation (POAF) is associated with increased morbidity and mortality. Epicardial injection of botulinum toxin may suppress POAF. OBJECTIVES: This study sought to assess the safety and efficacy of AGN-151607 for the prevention of POAF after cardiac surgery. METHODS: This phase 2, randomized, placebo-controlled trial assessed the safety and efficacy of AGN-151607, 125 U and 250 U vs placebo (1:1:1), for the prevention of POAF after cardiac surgery. Randomization was stratified by age (<65, ≥65 years) and type of surgery (nonvalvular/valve surgery). The primary endpoint was the occurrence of continuous AF ≥30 seconds. RESULTS: Among 312 modified intention-to-treat participants (placebo, n = 102; 125 U, n = 104; and 250 U, n = 106), the mean age was 66.9 ± 6.8 years; 17% were female; and 64% had coronary artery bypass graft (CABG) only, 12% had CABG + valve, and 24% had valve surgery. The primary endpoint occurred in 46.1% of the placebo group, 36.5% of the 125-U group (relative risk [RR] vs placebo: 0.80; 95% CI: 0.58-1.10; P = 0.16), and 47.2% of the 250-U group (RR vs placebo: 1.04; 95% CI: 0.79-1.37; P = 0.78). The primary endpoint was reduced in the 125-U group in those ≥65 years (RR: 0.64; 95% CI: 0.43-0.94; P = 0.02) with a greater reduction in CABG-only participants ≥65 years (RR: 0.49; 95% CI: 0.27-0.87; P = 0.01). Rehospitalization and rates of adverse events were similar across the 3 groups. CONCLUSIONS: There were no significant differences in the rate of POAF with either dose compared with placebo; however, there was a lower rate of POAF in participants ≥65 years undergoing CABG only and receiving 125 U of AGN-151607. These hypothesis-generating findings require investigation in a larger, adequately powered randomized clinical trial. (Botulinum Toxin Type A [AGN-151607] for the Prevention of Post-operative Atrial Fibrillation in Adult Participants Undergoing Open-chest Cardiac Surgery [NOVA]; NCT03779841); A Phase 2, Multi-Center, Randomized, Double-Blind, Placebo-Controlled, Dose Ranging Study to Evaluate the Efficacy and Safety of Botulinum Toxin Type A [AGN 151607] Injections into the Epicardial Fat Pads to Prevent Post-Operative Atrial Fibrillation in Patients Undergoing Open-Chest Cardiac Surgery; 2017-004399-68).

2.
Clin Infect Dis ; 78(1): 172-178, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-37787072

RESUMEN

BACKGROUND: Adults aged ≥65 years, adults with certain underlying medical conditions, and persons experiencing homelessness are at increased risk for invasive pneumococcal disease (IPD). Two new pneumococcal conjugate vaccines, 15-valent pneumococcal conjugate vaccine (PCV15) and 20-valent pneumococcal conjugate vaccine (PCV20), were recently approved for use in US adults. We describe the epidemiology of IPD among Alaska adults and estimate the proportion of IPD cases potentially preventable by new vaccines. METHODS: We used statewide, laboratory-based surveillance data to calculate and compare IPD incidence rates and 95% confidence intervals (CIs) among Alaska adults aged ≥18 years during 2011-2020 and estimate the proportion of IPD cases that were caused by serotypes in PCV15 and PCV20. RESULTS: During 2011-2020, 1164 IPD cases were reported among Alaska adults for an average annual incidence of 21.3 cases per 100 000 adults per year (95% CI, 20.1-22.5). Incidence increased significantly during the study period (P < .01). IPD incidence among Alaska Native adults was 4.7 times higher than among non-Alaska Native adults (95% CI, 4.2-5.2). Among adults experiencing homelessness in Anchorage, IPD incidence was 72 times higher than in the general adult population (95% CI, 59-89). Overall, 1032 (89%) Alaska adults with IPD had an indication for pneumococcal vaccine according to updated vaccination guidelines; 456 (39%) and 700 (60%) cases were caused by serotypes in PCV15 and PCV20, respectively. CONCLUSIONS: Use of PCV15 and PCV20 could substantially reduce IPD among adults in Alaska, including Alaska Native adults and adults experiencing homelessness.


Asunto(s)
Personas con Mala Vivienda , Infecciones Neumocócicas , Adulto , Humanos , Lactante , Adolescente , Streptococcus pneumoniae , Vacunas Conjugadas , Alaska/epidemiología , Infecciones Neumocócicas/epidemiología , Infecciones Neumocócicas/prevención & control , Vacunas Neumococicas , Serogrupo , Incidencia
3.
JACC Clin Electrophysiol ; 10(1): 16-26, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38032575

RESUMEN

BACKGROUND: There are conflicting data on the effect of cardiac resynchronization therapy with a defibrillator (CRT-D) on the risk of life-threatening ventricular tachyarrhythmia in heart failure patients. OBJECTIVES: The authors aimed to assess whether QRS morphology is associated with risk of ventricular arrhythmias in CRT recipients. METHODS: The study population comprised 2,862 patients implanted with implantable cardioverter defibrillator (ICD)/CRT-D for primary prevention who were enrolled in 5 landmark primary prevention ICD trials (MADIT-II [Multicenter Automated Defibrillator Implantation Trial], MADIT-CRT [Multicenter Automated Defibrillator Implantation Trial-Cardiac Resynchronization Therapy], MADIT-RIT [Multicenter Automated Defibrillator Implantation Trial-Reduction in Inappropriate Therapy], MADIT-RISK [Multicenter Automated Defibrillator Implantation Trial-RISK], and RAID [Ranolazine in High-Risk Patients With Implanted Cardioverter Defibrillators]). Patients with QRS duration ≥130 ms were divided into 2 groups: those implanted with an ICD only vs CRT-D. The primary endpoint was fast ventricular tachycardia (VT)/ventricular fibrillation (VF) (defined as VT ≥200 beats/min or VF), accounting for the competing risk of death. Secondary endpoints included appropriate shocks, any sustained VT or VF, and the burden of fast VT/VF, assessed in a recurrent event analysis. RESULTS: Among patients with left bundle branch block (n = 1,792), those with CRT-D (n = 1,112) experienced a significant 44% (P < 0.001) reduction in the risk of fast VT/VF compared with ICD-only patients (n = 680), a significantly lower burden of fast VT/VF (HR: 0.55; P = 0.001), with a reduced burden of appropriate shocks (HR: 0.44; P < 0.001). In contrast, among patients with non-left bundle branch block (NLBBB) (N = 1,070), CRT-D was not associated with reduction in fast VT/VF (HR: 1.33; P = 0.195). Furthermore, NLBBB patients with CRT-D experienced a statistically significant increase in the burden of fast VT/VF events compared with ICD-only patients (HR: 1.90; P = 0.013). CONCLUSIONS: Our data suggest a potential proarrhythmic effect of CRT among patients with NLBBB. These data should be considered in patient selection for treatment with CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Bloqueo de Rama/terapia , Bloqueo de Rama/etiología , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Resultado del Tratamiento , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/terapia
4.
Front Cardiovasc Med ; 10: 1237118, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37680559

RESUMEN

Introduction: The implantable cardioverter defibrillator (ICD) is effective for the prevention of sudden cardiac death (SCD) in patients with heart failure and a reduced ejection fraction (HFrEF). The benefit of the ICD in patients with advanced CKD, remains elusive. Moreover, the benefit of the ICD in patients with advanced chronic kidney disease (CKD) and HFrEF who are cardiac resynchronization therapy (CRT) recipients may be attenuated. Hypothesis: We hypothesized that patients with CKD who are CRT recipients may derive less benefit from the ICD due to the competing risk of dying prior to experiencing an arrhythmia. Methods: The study population included 1,015 patients receiving CRT with defibrillator (CRT-D) device for primary prevention of SCD who were enrolled in either (Multicenter Automated Defibrillator Implantation Trial) MADIT-CRT trial or the Ranolazine in High-Risk Patients with Implanted Cardioverter Defibrillator (RAID) trial. The cohort was divided into two groups based on the stage of CKD: those with Stage 1 to 3a KD, labeled as (S1-S3a)KD. The second group included patients with Stage 3b to stage 5 kidney disease, labeled as (S3b-S5)KD. The primary endpoint was any ventricular tachycardia (VT) or ventricular fibrillation (VF) (Any VT/VF). Results: The cumulative incidence of Any VT/VF was 23.5% in patients with (S1-S3a)KD and 12.6% in those with (S3b-S5)KD (p < 0.001) The incidence of Death without Any VT/VF was 6.6% in patients with (S1-S3a)KD and 21.6% in patients with (S3b-S5)KD (p < 0.001). A Fine and Gray multivariate competing risk regression model showed that Patients with (S3b-S5)KD had a 43% less risk of experiencing Any VT/VF when compared to those with (S1-S3a)KD (HR = 0.56, 95% CI [0.33-0.94] p = 0.03. After two years of follow up, there was almost a 5-fold increased risk of Death without Any VT/VF among patients with (S3b-S5)KD when compared to those with (S1-S3a)KD [HR = 4.63, 95% CI (2.46-8.72), p for interaction with time = 0.012]. Conclusion: Due to their lower incidence of arrhythmias and higher risk of dying prior to experiencing an arrhythmia, the benefit of the ICD may be attenuated in CRT recipients with advanced CKD. Future prospective trials should evaluate whether CRT without a defibrillator may be more appropriate for these patients.

5.
JACC Clin Electrophysiol ; 9(10): 2122-2131, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37656097

RESUMEN

BACKGROUND: Both selective and nonselective beta-blockers are used to treat patients with heart failure (HF). However, the data on the association of beta-blocker type with risk of atrial arrhythmia and ventricular arrhythmia (VA) in HF patients with a primary prevention implantable cardioverter-defibrillator (ICD) are limited. OBJECTIVES: This study sought to evaluate the effect of metoprolol vs carvedilol on the risk of atrial tachyarrhythmia (ATA) and VA in HF patients with an ICD. METHODS: This study pooled primary prevention ICD recipients from 5 landmark ICD trials (MADIT-II, MADIT-CRT, MADIT-RIT, MADIT-RISK, and RAID). Fine and Gray multivariate regression models, stratified by study, were used to evaluate the risk of ATA, inappropriate ICD shocks, and fast VA (defined as ventricular tachycardia ≥200 beats/min or ventricular fibrillation) by beta-blocker type. RESULTS: Among 4,194 patients, 2,920 (70%) were prescribed carvedilol and 1,274 (30%) metoprolol. The cumulative incidence of ATA at 3.5 years was 11% in patients treated with carvedilol vs 15% in patients taking metoprolol (P = 0.003). Multivariate analysis showed that carvedilol treatment was associated with a 35% reduction in the risk of ATA (HR: 0.65; 95% CI: 0.53-0.81; P < 0.001) when compared to metoprolol, and with a corresponding 35% reduction in the risk of inappropriate ICD shocks (HR: 0.65; 95% CI: 0.47-0.89; P = 0.008). Carvedilol vs metoprolol was also associated with a 16% reduction in the risk of fast VA. However, these findings did not reach statistical significance (HR: 0.84; 95% CI: 0.70-1.02; P = 0.085). CONCLUSIONS: These findings suggests that HF patients with ICDs on carvedilol treatment experience a significantly lower risk of ATA and inappropriate ICD shocks when compared to treatment with metoprolol.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Metoprolol/uso terapéutico , Carvedilol/uso terapéutico , Desfibriladores Implantables/efectos adversos , Fibrilación Atrial/inducido químicamente , Antagonistas Adrenérgicos beta/efectos adversos , Insuficiencia Cardíaca/complicaciones
6.
Emerg Infect Dis ; 29(9): 1765-1771, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37506683

RESUMEN

Streptococcus pneumoniae can co-infect persons who have viral respiratory tract infections. However, research on S. pneumoniae infections that are temporally associated with SARS-CoV-2 infections is limited. We described the epidemiology and clinical course of patients who had invasive pneumococcal disease (IPD) and temporally associated SARS-CoV-2 infections in Alaska, USA, during January 1, 2020-December 23, 2021. Of 271 patients who had laboratory-confirmed IPD, 55 (20%) had a positive SARS-CoV-2 test result. We observed no major differences in age, race, sex, or underlying medical conditions among IPD patients with and without SARS-CoV-2. However, a larger proportion of IPD patients with SARS-CoV-2 died (16%, n = 9) than for those with IPD alone (4%, n = 9) (p<0.01). IPD patients with SARS-CoV-2 were also more likely to be experiencing homelessness (adjusted OR 3.5; 95% CI 1.7-7.5). Our study highlights the risk for dual infection and ongoing benefits of pneumococcal and COVID-19 vaccination, especially among vulnerable populations.


Asunto(s)
COVID-19 , Infecciones Neumocócicas , Humanos , Alaska/epidemiología , Vacunas contra la COVID-19 , COVID-19/epidemiología , SARS-CoV-2 , Infecciones Neumocócicas/epidemiología , Infecciones Neumocócicas/prevención & control , Streptococcus pneumoniae , Vacunas Neumococicas
9.
JACC Clin Electrophysiol ; 9(7 Pt 1): 979-988, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36752470

RESUMEN

BACKGROUND: The benefit of implantable cardioverter-defibrillators (ICDs) in elderly patients is controversial. OBJECTIVES: The aims of this study were to evaluate the risk for ventricular tachyarrhythmia (VTA) and ICD shocks by age groups and to assess the competing risk for VTA and death without prior VTA. METHODS: The study included 5,170 primary prevention ICD recipients enrolled in 5 landmark ICD trials (MADIT [Multicenter Automatic Defibrillator Implantation Trial] II, MADIT-Risk, MADIT-CRT [MADIT Cardiac Resynchronization Therapy], MADIT-RIT [MADIT Reduce Inappropriate Therapy], and RAID [Ranolazine in High-Risk Patients With Implanted Cardioverter-Defibrillator]). Fine and Gray regression analysis was used to evaluate the risk for fast VTA (ventricular tachycardia ≥200 beats/min or ventricular fibrillation) vs death without prior fast VTA in 3 prespecified age groups: <65, 65 to <75, and ≥75 years. RESULTS: The cumulative incidence of fast VTA at 3 years was similar for patients <65 years of age and those 65 to <75 years of age (17% vs 15%) and was lowest among patients ≥75 years of age (10%) (P < 0.001). Multivariate Fine and Gray analysis showed a 40% lower risk for fast VTA in patients ≥75 years of age (HR: 0.60; 95% CI: 0.46-0.78; P < 0.001) compared with patients <65 years of age. In patients ≥75 years of age, a risk reversal was observed whereby the risk for death without prior fast VTA exceeded the risk for developing fast VTA. A history of nonsustained ventricular tachycardia, male sex, and the presence of nonischemic cardiomyopathy were identified as predictors of fast VTA in patients ≥75 years of age. CONCLUSIONS: Patients ≥75 years of age have a significantly lower risk for VTA and ICD shocks compared with younger patients. Aging is associated with a higher risk for death compared with the risk for fast VTA, the reverse of what is seen in younger patients.


Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Masculino , Anciano , Desfibriladores Implantables/efectos adversos , Fibrilación Ventricular/terapia , Fibrilación Ventricular/etiología , Cardioversión Eléctrica/efectos adversos , Cardiomiopatías/terapia
10.
Heart Vessels ; 38(7): 881-888, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36695858

RESUMEN

The optimal approach for prevention of cardiovascular events and reduction of bleeding in patients with acute coronary syndrome (ACS) and atrial fibrillation (AF) is still controversial. The aim of our study is to asses our single-center experience with concomitant left atrial appendage occlusion (LAAO) and percutaneous coronary intervention (PCI). 50 patients with ACS without ST elevation and history of AF were randomized after successful PCI to LAAO or conventional medical therapy. The primary endpoints were safety and length of hospitalization. The follow-up period was 30 days. The mean procedural times were 113 ± 23 min PCI + LAAO implantation and 39 ± 19 min of PCI only (p < 0.001), while mean fluoroscopy times were 18 ± 8 min and 12 ± 8 min (p < 0.001), respectively. No procedure-related complications were observed. There was no difference observed for length of hospitalization between two groups. LAAO in patients with ACS and AF undergoing PCI appears safe.


Asunto(s)
Síndrome Coronario Agudo , Apéndice Atrial , Fibrilación Atrial , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Proyectos Piloto , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/cirugía , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios de Factibilidad , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
11.
Ann Noninvasive Electrocardiol ; 28(2): e13043, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36718801

RESUMEN

BACKGROUND: Percutaneous catheter ablation (CA) to achieve pulmonary vein isolation is an effective treatment for drug-refractory paroxysmal and persistent atrial fibrillation (AF). However, recurrence rates after a single AF ablation procedure remain elevated. Conventional management after CA ablation has mostly been based on clinical AF recurrence. However, continuous recordings with insertable cardiac monitors (ICMs) and patient-triggered mobile app transmissions post-CA can now be used to detect early recurrences of subclinical AF (SCAF). We hypothesize that early intervention following CA based on personalized ICM data can prevent the substrate progression that promotes the onset and maintenance of atrial arrhythmias. METHODS: This is a randomized, double-blind (to SCAF data), single-tertiary center clinical trial in which 120 patients with drug-refractory paroxysmal or persistent AF are planned to undergo CA with an ICM. Randomization will be to an intervention arm (n = 60) consisting of ICM-guided early intervention based on SCAF and patient-triggered mobile app transmissions versus a control arm (n = 60) consisting of a standard intervention protocol based on clinical AF recurrence validated by the ICM. Primary endpoint is AF burden, which will be assessed from ICMs at 15 months post-AF ablation. Secondary endpoints include healthcare utilization, functional capacity, and quality of life. CONCLUSION: We believe that ICM-guided early intervention will provide a novel, personalized approach to post-AF ablation management that will result in a significant reduction in AF burden, healthcare utilization, and improvements in functional capacity and quality of life.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Electrocardiografía , Resultado del Tratamiento , Protocolos Clínicos , Ablación por Catéter/métodos , Recurrencia , Ensayos Clínicos Controlados Aleatorios como Asunto
12.
Ann Noninvasive Electrocardiol ; 28(1): e13021, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36436199

RESUMEN

BACKGROUND: Patients with heart failure (HF) represent a large population of patients who are at high risk for complications related to undiagnosed atrial fibrillation (AF). However, currently there are limited modalities available for early AF detection in this high-risk population. An implantable cardiac monitor (ICM) is inserted subcutaneously and can provide long-term arrhythmia information via remote monitoring. METHODS AND RESULTS: Confirm-AF is a prospective randomized, nonblinded, two arm, multicenter clinical trial to be performed in the United States, enrolling 477 patients with a history of HF hospitalization and left ventricular ejection fraction >35% from 30 medical sites. Patients will be randomized in a 2:1 fashion to undergo ICM implant with remote monitoring and symptom-triggered mobile app transmissions versus (vs.) Non-ICM management and follow-up. The primary objective of this trial is to compare the time to first detection of AF lasting > 5 min using an Abbott ICM compared to non-ICM monitoring in symptomatic HF patients. This article describes the design and analytic plan for the Confirm-AF trial. CONCLUSIONS: The Confirm-AF trial seeks to accurately define the burden of AF in high-risk HF patients with LVEF > 35% using an Abbott ICM. A finding showing significantly higher incidence of AF along with improved clinical outcomes with ICM monitoring is expected to have substantial clinical implications and may change the method of monitoring high-risk HF patients.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Estados Unidos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Estudios Prospectivos , Volumen Sistólico , Electrocardiografía , Electrocardiografía Ambulatoria/métodos , Función Ventricular Izquierda , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico
13.
Eur Heart J ; 44(9): 765-776, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36459112

RESUMEN

AIMS: Atrial tachyarrhythmia recurrence ≥30 s remains the primary endpoint of clinical trials; however, this definition has not been correlated with clinical outcomes or pathophysiological processes. This study sought to determine the atrial tachyarrhythmia duration and burden associated with meaningful clinical outcomes. METHODS AND RESULTS: The time and duration of every atrial tachyarrhythmia episode recorded on implantable cardiac monitor were evaluated. Healthcare utilization and quality of life in the year following ablation were prospectively collected. Three hundred and forty-six patients provided 126 110 monitoring days. One-year freedom from recurrence increased with arrhythmia duration thresholds, from 52.6 (182/346) to 93.3% (323/346; P < 0.0001). Patients with atrial fibrillation (AF) recurrence limited to durations ≤1 h had rates of healthcare utilization comparable with patients free of recurrence, while patients with AF recurrences lasting >1 h had a relative risk for emergency department consultation of 3.2 [95% confidence interval (CI) 2.0-5.3], hospitalization of 5.3 (95% CI 2.9-9.6), and repeat ablation of 27.1 (95% CI 10.5-71.0). Patients with AF burden of ≤0.1% had rates of healthcare utilization comparable with patients free of recurrence, while patients with AF burden of >0.1% had a relative risk for emergency department consultation of 2.4 (95% CI 1.9-3.9), hospitalization of 6.8 (95% CI 3.6-13.0), cardioversion of 9.1 (95% CI 3.3-25.6), and repeat ablation of 21.8 (95% CI 9.2-52.2). Compared with patients free of recurrence, the disease-specific quality of life was significantly impaired with AF episode durations >24 h, or AF burdens >0.1%. CONCLUSION: AF recurrence, as defined by 30 s of arrhythmia, lacks clinical relevance. AF episode durations >1 h or burdens >0.1% were associated with increased rates of healthcare utilization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Calidad de Vida , Taquicardia , Aceptación de la Atención de Salud , Ablación por Catéter/métodos , Recurrencia
14.
Phys Rev Lett ; 129(22): 220502, 2022 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-36493431

RESUMEN

Advances in quantum technology require scalable techniques to efficiently extract information from a quantum system. Traditional tomography is limited to a handful of qubits, and shadow tomography has been suggested as a scalable replacement for larger systems. Shadow tomography is conventionally analyzed based on outcomes of ideal projective measurements on the system upon application of randomized unitaries. Here, we suggest that shadow tomography can be much more straightforwardly formulated for generalized measurements, or positive operator valued measures. Based on the idea of the least-square estimator shadow tomography with generalized measurements is both more general and simpler than the traditional formulation with randomization of unitaries. In particular, this formulation allows us to analyze theoretical aspects of shadow tomography in detail. For example, we provide a detailed study of the implication of symmetries in shadow tomography. Moreover, with this generalization we also demonstrate how the optimization of measurements for shadow tomography tailored toward a particular set of observables can be carried out.


Asunto(s)
Tomografía
16.
Public Health Rep ; 137(5): 972-979, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35848091

RESUMEN

OBJECTIVES: Classroom layout plays a central role in maintaining physical distancing as part of a multicomponent prevention strategy for safe in-person learning during the COVID-19 pandemic. We conducted a school investigation to assess layouts and physical distancing in classroom settings with and without in-school SARS-CoV-2 transmission. METHODS: We assessed, measured, and mapped 90 K-12 (kindergarten through grade 12) classrooms in 3 Missouri public school districts during January-March 2021, prior to widespread prevalence of the Delta variant; distances between students, teachers, and people with COVID-19 and their contacts were analyzed. We used whole-genome sequencing to further evaluate potential transmission events. RESULTS: The investigation evaluated the classrooms of 34 students and staff members who were potentially infectious with COVID-19 in a classroom. Of 42 close contacts (15 tested) who sat within 3 ft of possibly infectious people, 1 (2%) probable transmission event occurred (from a symptomatic student with a longer exposure period [5 days]); of 122 contacts (23 tested) who sat more than 3 ft away from possibly infectious people with shorter exposure periods, no transmission events occurred. CONCLUSIONS: Reduced student physical distancing is one component of mitigation strategies that can allow for increased classroom capacity and support in-person learning. In the pre-Delta variant period, limited physical distancing (<6 ft) among students in K-12 schools was not associated with increased SARS-CoV-2 transmission.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiología , COVID-19/prevención & control , Humanos , Missouri/epidemiología , Pandemias/prevención & control , Instituciones Académicas
17.
J Intell ; 10(3)2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35893270

RESUMEN

Competency in skills associated with collaborative problem solving (CPS) is critical for many contexts, including school, the workplace, and the military. Innovative approaches for assessing individuals' CPS competency are necessary, as traditional assessment types such as multiple -choice items are not well suited for such a process-oriented competency. In a move to computer-based environments to support CPS assessment, innovative computational approaches are also needed to understand individuals' CPS behaviors. In the current study, we describe the use of a simulation-based task on electronics concepts as an environment for higher education students to display evidence of their CPS competency. We further describe computational linguistic methods for automatically characterizing students' display of various CPS skills in the task. Comparisons between such an automated approach and an approach based on human annotation to characterize student CPS behaviors revealed above average agreement. These results give credence to the potential for automated approaches to help advance the assessment of CPS and to circumvent the time-intensive human annotation approaches that are typically used in these contexts.

19.
Circ Arrhythm Electrophysiol ; 15(4): e010435, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35333097

RESUMEN

Atrial cardiomyopathy, characterized by abnormalities in atrial structure and function, is associated with increased risk of adverse cardiovascular and neurocognitive outcomes, independent of atrial fibrillation. There exists a critical unmet need for a clinical tool that is cost-effective, easy to use, and that can diagnose atrial cardiomyopathy. P wave parameters (PWPs) reflect underlying atrial structure, size, and electrical activation; alterations in these factors manifest as abnormalities in PWPs that can be readily ascertained from a standard 12-lead ECG and potentially be used to aid clinical decision-making. PWPs include P wave duration, interatrial block, P wave terminal force in V1, P wave axis, P wave voltage, P wave area, and P wave dispersion. PWPs can be combined to yield an index (P wave index), such as the morphology-voltage-P-wave duration ECG risk score. Abnormal PWPs have been shown in population-based cohort studies to be independently associated with higher risks of atrial fibrillation, ischemic stroke, sudden cardiac death, and dementia. Additionally, PWPs, either individually or in combination (as a P wave index), have been reported to enhance prediction of atrial fibrillation or ischemic stroke. To facilitate translation of PWPs to routine clinical practice, additional work is needed to standardize measurement of PWPs (eg, via semiautomated or automated measurement), confirm their reliability and predictive value, leverage novel approaches (eg, wavelet analysis of P waves and machine learning algorithms), and finally, define the risk-benefit ratio of specific interventions in high-risk individuals. Our ultimate goal is to repurpose the ubiquitous 12-lead ECG to advance the study, diagnosis, and treatment of atrial cardiomyopathy, thus overcoming critical challenges in prevention of cardiovascular disease and dementia.


Asunto(s)
Fibrilación Atrial , Demencia , Accidente Cerebrovascular Isquémico , Fibrilación Atrial/diagnóstico , Consenso , Electrocardiografía , Humanos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...