Resultados 1 - 20 de 198
Filtrar
1.
Sci Rep ; 14(1): 8194, 2024 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589554

RESUMEN

Accurate modeling of cerebral hemodynamics is crucial for better understanding the hemodynamics of stroke, for which computational fluid dynamics (CFD) modeling is a viable tool to obtain information. However, a comprehensive study on the accuracy of cerebrovascular CFD models including both transient arterial pressures and flows does not exist. This study systematically assessed the accuracy of different outlet boundary conditions (BCs) comparing CFD modeling and an in-vitro experiment. The experimental setup consisted of an anatomical cerebrovascular phantom and high-resolution flow and pressure data acquisition. The CFD model of the same cerebrovascular geometry comprised five sets of stationary and transient BCs including established techniques and a novel BC, the phase modulation approach. The experiment produced physiological hemodynamics consistent with reported clinical results for total cerebral blood flow, inlet pressure, flow distribution, and flow pulsatility indices (PI). The in-silico model instead yielded time-dependent deviations between 19-66% for flows and 6-26% for pressures. For cerebrovascular CFD modeling, it is recommended to avoid stationary outlet pressure BCs, which caused the highest deviations. The Windkessel and the phase modulation BCs provided realistic flow PI values and cerebrovascular pressures, respectively. However, this study shows that the accuracy of current cerebrovascular CFD models is limited.


Asunto(s)
Hemodinámica , Hidrodinámica , Velocidad del Flujo Sanguíneo , Presión Arterial , Simulación por Computador , Circulación Cerebrovascular , Modelos Cardiovasculares
2.
Biomater Sci ; 12(8): 2149-2164, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38487997

RESUMEN

The sole effective treatment for most patients with heart valve disease is valve replacement by implantation of mechanical or biological prostheses. However, mechanical valves represent high risk of thromboembolism, and biological prostheses are prone to early degeneration. In this work, we aim to determine the potential of novel environmentally-friendly non-isocyanate polyurethanes (NIPUs) for manufacturing synthetic prosthetic heart valves. Polyhydroxyurethane (PHU) NIPUs are synthesized via an isocyanate-free route, tested in vitro, and used to produce aortic valves. PHU elastomers reinforced with a polyester mesh show mechanical properties similar to native valve leaflets. These NIPUs do not cause hemolysis. Interestingly, both platelet adhesion and contact activation-induced coagulation are strongly reduced on NIPU surfaces, indicating low thrombogenicity. Fibroblasts and endothelial cells maintain normal growth and shape after indirect contact with NIPUs. Fluid-structure interaction (FSI) allows modeling of the ideal valve design, with minimal shear stress on the leaflets. Injection-molded valves are tested in a pulse duplicator and show ISO-compliant hydrodynamic performance, comparable to clinically-used bioprostheses. Poly(tetrahydrofuran) (PTHF)-NIPU patches do not show any evidence of calcification over a period of 8 weeks. NIPUs are promising sustainable biomaterials for the manufacturing of improved prosthetic valves with low thrombogenicity.


Asunto(s)
Prótesis Valvulares Cardíacas , Poliuretanos , Humanos , Poliuretanos/química , Isocianatos , Células Endoteliales , Válvula Aórtica/cirugía
3.
ASAIO J ; 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38386997

RESUMEN

Rotary blood pumps in Extracorporeal Life Support (ECLS) applications are optimized for a specific design point. However, in clinical practice, these pumps are usually applied over a wide range of operation points. Studies have shown that a deviation from the design point in a rotary blood pump leads to an unexpected rise of hemolysis with corresponding clinical complications. Adjustable pumps that can adapt geometric parameters to the respective operation point are commonly used in other industrial branches, but yet not applied in blood pumps. We present a novel mechanism to adjust the impeller geometry of a centrifugal blood pump during operation together with in-vitro data of its hydraulic performance and efficiency. Three-dimensionalprinted prototypes of the adjustable impeller and a rigid impeller were manufactured and hydraulic performance and efficiency measured (n = 3). In a flow range of 1.5-9.5 L/min, the adjustable pump increased pump performance up to 47% and hydraulic efficiency by an average of 7.3 percentage points compared with a fixed setting. The adjustable pump allows customization of the pump's behavior (steepness of performance curve) according to individual needs. Furthermore, the hydraulic efficiency of the pump could be maintained at a high level throughout the complete flow range.

4.
Comput Biol Med ; 168: 107772, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38064846

RESUMEN

This study applies non-intrusive polynomial chaos expansion (NIPCE) surrogate modeling to analyze the performance of a rotary blood pump (RBP) across its operating range. We systematically investigate key parameters, including polynomial order, training data points, and data smoothness, while comparing them to test data. Using a polynomial order of 4 and a minimum of 20 training points, we successfully train a NIPCE model that accurately predicts pressure head and axial force within the specified operating point range ([0-5000] rpm and [0-7] l/min). We also assess the NIPCE model's ability to predict two-dimensional velocity data across the given range and find good overall agreement (mean absolute error = 0.1 m/s) with a test simulation under the same operating condition. Our approach extends current NIPCE modeling of RBPs by considering the entire operating range and providing validation guidelines. While acknowledging computational benefits, we emphasize the challenge of modeling discontinuous data and its relevance to clinically realistic operating points. We offer open access to our raw data and Python code, promoting reproducibility and accessibility within the scientific community. In conclusion, this study advances comprehensive NIPCE modeling of RBP performance and underlines how critically NIPCE parameters and rigorous validation affect results.


Asunto(s)
Corazón Auxiliar , Reproducibilidad de los Resultados , Simulación por Computador , Modelos Cardiovasculares
5.
Micromachines (Basel) ; 14(4)2023 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-37421033

RESUMEN

The overall survival rate of extracorporeal life support (ECLS) remains at 60%. Research and development has been slow, in part due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator ("RatOx") and presents preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performances over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199. At the maximum possible amount of effective fiber surface area and a blood flow of 100 mL/min, the oxygenator performance was tested to a maximum of 6.27 mL O2/min and 8.2 mL CO2/min, respectively. The priming volume for the largest fiber module is 5.4 mL, while the smallest possible configuration with a single fiber mat layer has a priming volume of 1.1 mL. The novel RatOx ECLS system has been evaluated in vitro and has demonstrated a high degree of compliance with all pre-defined functional criteria for rodent-sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.

6.
Front Physiol ; 14: 1136545, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37228828

RESUMEN

Purpose: Blood damage has been associated with patients under temporary continuous-flow mechanical circulatory support. To evaluate the side effects caused by transit blood pumping, in vitro hemocompatibility testing for blood damage in pumps is considered a necessary reference before clinical trials. Methods: The hemocompatibility of five extracorporeal centrifugal blood pumps was investigated comprehensively, including four commercial pumps (the Abbott CentriMag, the Terumo Capiox, the Medos DP3, and the Medtronic BPX-80) and a pump in development (the magAssist MoyoAssist®). In vitro, hemolysis was tested with heparinized porcine blood at nominal operating conditions (5 L/min, 160 mmHg) and extreme operating conditions (1 L/min, 290 mmHg) using a circulation flow loop. Hematology analyses concerning the blood cell counts and the degradation of high-molecular-weight von Willebrand factor (VWF) during 6-h circulation were also evaluated. Results: Comparing the in vitro hemocompatibility of blood pumps at different operations, the blood damage was significantly more severe at extreme operating conditions than that at nominal operating conditions. The performance of the five blood pumps was arranged in different orders at these two operating conditions. The results also demonstrated superior hemocompatibility of CentriMag and MoyoAssist® at two operating conditions, with overall low blood damage at hemolysis level, blood cell counts, and degradation of high-molecular-weight VWF. It suggested that magnetic bearings have an advantage in hemocompatibility compared to the mechanical bearing of blood pumps. Conclusion: Involving multiple operating conditions of blood pumps in in vitro hemocompatibility evaluation will be helpful for clinical application. In addition, the magnetically levitated centrifugal blood pump MoyoAssist® shows great potential in the future as it demonstrated good in vitro hemocompatibility.

7.
Cardiovasc Intervent Radiol ; 46(5): 658-663, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36826490

RESUMEN

PURPOSE: To investigate and compare the physical properties of the new generation Gore VIATORR-Controlled Expansion Endoprosthesis (VCX) to those of the predecessor VIATORR stent in an in vitro experimental setup. MATERIALS AND METHODS: A total of 12 stents (8 VCX; 4 VIATORR; GORE, USA) were examined. Radial resistive force (RRF) and chronic outward force (COF) were assessed using a radial force testing machine (RX-650, Machine Solutions Inc., USA). To assess the radial forces of the VCX above 8 mm, balloon expansion was performed between cycles. RESULTS: All VCX stents show an abrupt decrease in COF at an external diameter of 8.3 mm; RRF decreases likewise at an external diameter of 8.5 mm. The predecessor VIATORR stent without the "controlled expansion" feature shows linear radial force reduction until full expansion at a diameter of 10 mm. The physical properties of the VCX can be altered by balloon modulation. Point of COF (RRF) reduction shifts to 8.5 mm (8.6 mm), 8.6 mm (8.8 mm) and 9.3 mm (9.6 mm) following modulation with a 8 mm, 9 mm and 10 mm balloon. CONCLUSIONS: The VCX shows an abrupt and disproportionate decrease in COF and RRF at an external diameter of 8.3 mm, thus passive expansion to its nominal diameter of 10 mm is not to be expected. By means of balloon dilatation the physical properties of the stent can be altered, enabling customized TIPS creation. The previous VIATORR stent shows continuous COF and RRF until total expansion.


Asunto(s)
Derivación Portosistémica Intrahepática Transyugular , Humanos , Stents , Diseño de Prótesis
8.
J Cardiovasc Transl Res ; 16(4): 842-851, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36662482

RESUMEN

When returning blood to the pulmonary artery (PA), the inflow jet interferes with local hemodynamics. We investigated the consequences for several connection scenarios using transient computational fluid dynamics simulations. The PA was derived from CT data. Three aspects were varied: graft flow rate, anastomosis location, and inflow jet path length from anastomosis site to impingement on the PA wall. Lateral anastomosis locations caused abnormal flow distribution between the left and right PA. The central location provided near-physiological distribution but induced higher wall shear stress (WSS). All effects were most pronounced at high graft flows. A central location is beneficial regarding flow distribution, but the resulting high WSS might promote detachment of local thromboembolisms or influence the autonomic nervous innervation. Lateral locations, depending on jet path length, result in lower WSS at the cost of an unfavorable flow distribution that could promote pulmonary vasculature changes. Case-specific decisions and further research are necessary.


Asunto(s)
Hidrodinámica , Arteria Pulmonar , Arteria Pulmonar/cirugía , Hemodinámica , Modelos Cardiovasculares , Estrés Mecánico , Simulación por Computador
9.
Int J Numer Method Biomed Eng ; 39(11): e3684, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36629779

RESUMEN

Blood flow within the left ventricle provides important information regarding cardiac function in health and disease. The mitral valve strongly influences the formation of flow structures and there exist various approaches for the representation of the valve in numerical models of left ventricular blood flow. However, a systematic comparison of the various mitral valve models is missing, making a priori decisions considering the overall model's context of use impossible. Within this study, a benchmark setup to compare the influence of mitral valve modeling strategies on intraventricular flow features was developed. Then, five mitral valve models of increasing complexity: no modeling, static wall, 2D and 3D porous medium with time-dependent porosity, and one-way fluid-structure interaction (FSI) were compared with each other. The flow features velocity, kinetic energy, transmitral pressure drop, vortex formation, flow asymmetry as well as computational cost and ease-of-implementation were evaluated. The one-way FSI approach provides the highest level of flow detail, which is accompanied by the highest numerical costs and challenges with the implementation. As an alternative, the porous medium approach with the expansion including time-dependent porosity provides good results with up to 10% deviations in the flow features (except the transmitral pressure drop) in comparison to the FSI model and only a fraction (11%) of numerical costs. However, jet propagation speed is highly underestimated by all alternative approaches to the FSI model. Taken together, our benchmark setup allows a quantitative comparison of various mitral valve modeling approaches and is provided to the scientific community for further testing and expansion.


Asunto(s)
Ventrículos Cardíacos , Válvula Mitral , Válvula Mitral/fisiología , Modelos Cardiovasculares , Hemodinámica , Velocidad del Flujo Sanguíneo/fisiología
10.
Artif Organs ; 47(4): 695-704, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36420613

RESUMEN

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) became an accepted therapy for the treatment of severe acute respiratory distress syndrome and chronic obstructive pulmonary disease. However, ECMO systems are still prone to thrombus formation and decrease of gas exchange over time. Therefore, it is necessary to conduct qualified studies to identify parameters for optimization of ECMO systems, and especially the oxygenator. However, commercially marketed oxygenators are not always appropriate and available for certain research use cases. Therefore, we aimed to design an oxygenator, which is suitable for various test conditions such as blood tests, numerical simulation, and membrane studies, and can be modified in membrane area size and manufactured in laboratory. METHODS: Main design criteria are a homogeneous blood flow without stagnation zones, low pressure drop, manufacturability in the lab, size variability with one set of housing parts and cost-efficiency. Our newly designed oxygenator was tested comparatively regarding blood cell damage, gas transfer performance and pressure drop to prove the validity of the design in accordance with a commercial device. RESULTS: No statistically significant difference between the tested oxygenators was detected and our new oxygenator demonstrated sufficient hemocompatibility. Furthermore, our variable oxygenator has proven that it can be easily manufactured in the laboratory, allows to use various membrane fiber configurations and can be reopened easily and non-destructively for analysis after use, and the original geometry is available for numerical simulations. CONCLUSION: Therefore, we consider this newly developed device as a valuable tool for basic experimental and numerical research on the optimization of oxygenators.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Enfermedad Pulmonar Obstructiva Crónica , Síndrome de Dificultad Respiratoria , Trombosis , Humanos , Oxigenadores , Oxigenación por Membrana Extracorpórea/métodos , Síndrome de Dificultad Respiratoria/diagnóstico , Síndrome de Dificultad Respiratoria/terapia , Diseño de Equipo , Oxigenadores de Membrana
11.
Artif Organs ; 47(5): 817-827, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36495089

RESUMEN

BACKGROUND: In the total artificial heart (TAH), the inputs to the physiological control unit, preload, and afterload, are detected from intrinsic pump parameters (e.g., motor current). Within this study, their detection techniques are developed, and their reliability in pre- and afterload prediction is mapped for a broad range of cardiovascular system states. METHODS: We used ReinHeart TAH which is a fully implantable TAH with a plunger coil drive that is alternately emptying the left and right chambers. From the coil currents we first derived a force generated by the piston with respect to its position and then analyzed its pattern to detect (1) preload-chamber filling, found as piston position at begin ejection and (2) afterload-mean outflow pressures, determined as linearly calibrated average piston force during ejection. TAH is then integrated into a mock loop circulation (MLC) which is set to 135 different steady operating points varying in chamber filling (0%-100%, five steps), mean outflow pressures (system circulation: 60-90-120 mm Hg, pulmonary circulation: 15-30-45 mm Hg), and heart cycle duration (171-600 ms in seven non-equidistant steps). The detected preload and afterload are compared to MLC set values, and the errors are mapped. RESULTS: Respectively for the left and right chambers, the preload was detectable in 134 and 118 operating points and the mean error was ±3% and ±2%. The afterload was detectable in 135 and 87 operating points and the mean error was 37% and 30% respectively for left and right circulation. The operational points that are further away from homeostatic equilibrium values generally yielded larger errors. The largest errors were observed for right circulation at long cycle duration, low afterload, and low filling. CONCLUSIONS: The study yields reliable preload estimation in a broad range of physiological states, particularly for left circulation. Detection of afterload needs further improvements. The study revealed a need for piston movement optimization within the ReinHeart TAH during the early phase of systole.


Asunto(s)
Corazón Artificial , Corazón , Reproducibilidad de los Resultados , Sístole , Circulación Pulmonar
12.
J Neurointerv Surg ; 15(5): 502-506, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35414603

RESUMEN

BACKGROUND: Catheter size, location and circle of Willis anatomy impact the flow conditions during interventional stroke therapy. The aim of the study was to systematically investigate the influence of these factors on flow control in the middle cerebral artery by means of a computational model based on 100 patients with stroke who received endovascular treatment. METHODS: The dimensions of the cervical and intracranial cerebral arteries of 100 patients who received endovascular mechanical thrombectomy for acute ischemic stroke were measured and a three-dimensional model of the circle of Willis was created based on these data. Flow control in the middle cerebral artery with variations in catheter size, catheter location and configurations of collateral vessels was determined using a computational model. A total of 48 scenarios were analyzed. RESULTS: Flow reversal with a distal aspiration catheter alone was not possible in the internal carotid artery and only sometimes possible in the middle cerebral artery (14 of 48 cases). The Catalyst 7 catheter was more often successful in achieving flow reversal than Catalyst 5 or 6 catheters (p<0.001). In a full circle of Willis anatomy, flow reversal was almost never possible. The absence of one or more communicating arteries significantly influenced flow direction compared with the full anatomy with all communicating arteries present (p=0.028). CONCLUSION: Choosing the biggest possible aspiration catheter and locating it in the middle cerebral artery significantly increases the chances of successful flow control. Flow through the collaterals may impair the flow, and circle of Willis anatomy should be considered during aspiration thrombectomy.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Arteria Cerebral Media/diagnóstico por imagen , Arteria Cerebral Media/cirugía , Catéteres , Trombectomía/métodos , Círculo Arterial Cerebral/diagnóstico por imagen , Círculo Arterial Cerebral/cirugía
13.
Innovations (Phila) ; 17(6): 528-537, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36571269

RESUMEN

OBJECTIVE: Extracorporeal life support (ECLS) for circulatory and/or respiratory failure is improving. Currently, invasive sternotomies or rib-spreading thoracotomies are used for central cannulation of the heart and great vessels. Although peripheral cannulation of the extremities is often used, this approach may result in immobility and unintentional dislodgement. Less invasive methods for central cannulation are needed to achieve long-term ECLS. The objective of this study was to develop 2 different minimally invasive approaches for central thoracic cannulation. METHODS: Porcine hearts were positioned in a plastic thoracic model. An endoscopic camera and multiple endoscopic instruments were used. Both access points, uniportal (lateral) and subxiphoidal, were simulatively investigated. A novel cannulation method using purse string sutures, a custom-made endoscopic puncture tool, guidewires, and dilator-assisted cannulas was developed. Simulations were tested in a closed circuit regarding leak tightness. RESULTS: The uniportal approach allowed a cannulation of the aorta, inferior vena cava, right atrium, and main pulmonary artery. Cannulation of the right branches of the pulmonary artery and vein was also possible. From the subxiphoid approach, cannulation of the aorta, main pulmonary artery, and both atria were possible. Subsequent evaluation and leakage tests revealed no damage to the surrounding structures and tightly sealed cannulation sites. The uniportal approach was also successfully performed in a human cadaver to connect the aorta and right atrium with cannulas from the subxiphoidal space. CONCLUSIONS: Both uniportal and subxiphoid central cannulation of potential sites for ECLS were feasible. This study encourages further investigation and potential clinical translation of minimally invasive central organ support.


Asunto(s)
Cateterismo , Oxigenación por Membrana Extracorpórea , Humanos , Animales , Porcinos , Oxigenación por Membrana Extracorpórea/métodos , Arteria Pulmonar , Aorta , Atrios Cardíacos
14.
Biomed Tech (Berl) ; 67(6): 471-480, 2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36041741

RESUMEN

In vitro thrombogenicity tests for rotary blood pumps (RBPs) could benefit from assessing coagulation kinematics, as RBP design improves. In this feasibility study, we investigated if the method of thromboelastometry (TEM) is able to assess coagulation kinematics under the in vitro conditions of RBP tests. We conducted in vitro thrombogenicity tests (n=4) by placing Deltastream® DP3 pumps into test loops that were filled with 150 mL of slightly anti-coagulated porcine blood, adjusted to an activated clotting time (ACT) well below clinically recommended levels. Blood samples were taken at certain time points during the experiment until a continuous decrease in pump flow indicated major thrombus formation. Blood samples were analyzed for ACT, platelet count (PLT), and several TEM parameters. While visible thrombus formation was observed in three pumps, ACT indicated an ongoing activation of coagulation, PLT might have indicated platelet consumption. Unexpectedly, most TEM results gave no clear indications. Nonetheless, TEM clotting time obtained by non-anticoagulated and chemically non-activated whole blood (HEPNATEM-CT) appeared to be more sensitive for the activation of coagulation in vitro than ACT, which might be of interest for future pump tests. However, more research regarding standardization of thrombogenicity pump tests is urgently required.


Asunto(s)
Circulación Asistida , Corazón Auxiliar , Trombosis , Porcinos , Animales , Tromboelastografía , Coagulación Sanguínea , Plaquetas
15.
Sci Rep ; 12(1): 7160, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-35504939

RESUMEN

Membrane lungs consist of thousands of hollow fiber membranes packed together as a bundle. The devices often suffer from complications because of non-uniform flow through the membrane bundle, including regions of both excessively high flow and stagnant flow. Here, we present a proof-of-concept design for a membrane lung containing a membrane module based on triply periodic minimal surfaces (TPMS). By warping the original TPMS geometries, the local permeability within any region of the module could be raised or lowered, allowing for the tailoring of the blood flow distribution through the device. By creating an iterative optimization scheme for determining the distribution of streamwise permeability inside a computational porous domain, the desired form of a lattice of TPMS elements was determined via simulation. This desired form was translated into a computer-aided design (CAD) model for a prototype device. The device was then produced via additive manufacturing in order to test the novel design against an industry-standard predicate device. Flow distribution was verifiably homogenized and residence time reduced, promising a more efficient performance and increased resistance to thrombosis. This work shows the promising extent to which TPMS can serve as a new building block for exchange processes in medical devices.


Asunto(s)
Pulmón , Simulación por Computador , Membranas , Permeabilidad , Porosidad
16.
Membranes (Basel) ; 12(2)2022 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-35207055

RESUMEN

Extracorporeal membrane oxygenation (ECMO) is an established rescue therapy for patients with chronic respiratory failure waiting for lung transplantation (LTx). The therapy inherent immobilization may result in fatigue, consecutive deteriorated prognosis, and even lost eligibility for transplantation. We conducted a feasibility study on a novel system designed for the deployment of a portable ECMO device, enabling the physical exercise of awake patients prior to LTx. The system comprises a novel oxygenator with a directly connected blood pump, a double-lumen cannula, gas blender and supply, as well as control and energy management. In vitro experiments included tests regarding performance, efficiency, and blood damage. A reduced system was tested in vivo for feasibility using a novel large animal model. Six anesthetized pigs were first positioned in supine position, followed by a 45° angle, simulating an upright position of the patients. We monitored performance and vital parameters. All in vitro experiments showed good performance for the respective subsystems and the integrated system. The acute in vivo trials of 8 h duration confirmed the results. The novel portable ECMO-system enables adequate oxygenation and decarboxylation sufficient for, e.g., the physical exercise of designated LTx-recipients. These results are promising and suggest further preclinical studies on safety and efficacy to facilitate translation into clinical application.

17.
Cardiovasc Eng Technol ; 13(4): 638-649, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35031981

RESUMEN

PURPOSE: Thrombosis ranks among the major complications in blood-carrying medical devices and a better understanding to influence the design related contribution to thrombosis is desirable. Over the past years many computational models of thrombosis have been developed. However, numerically cheap models able to predict localized thrombus risk in complex geometries are still lacking. The aim of the study was to develop and test a computationally efficient model for thrombus risk prediction in rotary blood pumps. METHODS: We used a two-stage approach to calculate thrombus risk. The first stage involves the computation of velocity and pressure fields by computational fluid dynamic simulations. At the second stage, platelet activation by mechanical and chemical stimuli was determined through species transport with an Eulerian approach. The model was compared with existing clinical data on thrombus deposition within the HeartMate II. Furthermore, an operating point and model parameter sensitivity analysis was performed. RESULTS: Our model shows good correlation (R2 > 0.93) with clinical data and identifies the bearing and outlet stator region of the HeartMate II as the location most prone to thrombus formation. The calculation of thrombus risk requires an additional 10-20 core hours of computation time. CONCLUSION: The concentration of activated platelets can be used as a surrogate and computationally low-cost marker to determine potential risk regions of thrombus deposition in a blood pump. Relative comparisons of thrombus risk are possible even considering the intrinsic uncertainty in model parameters and operating conditions.


Asunto(s)
Corazón Auxiliar , Trombosis , Plaquetas , Corazón Auxiliar/efectos adversos , Humanos , Hidrodinámica , Activación Plaquetaria , Trombosis/etiología
18.
ASAIO J ; 68(1): 34-40, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33769348

RESUMEN

A downsized version of the ReinHeart total artificial heart (TAH) was developed. Hemocompatibility needs to be revised since the operating point of the downsized TAH has changed to a higher pump frequency to accomplish the same cardiac output. A mock circulation loop was designed, containing a left side for hemocompatibility testing and a right side to mimic realistic work conditions. A protocol for hemolysis testing was established using pooled porcine blood with an operation point of 5 L/min, a mean outlet pressure of 100 mm Hg and a mean inlet pressure of 12 mm Hg. Six trials were performed testing two downsized TAH (one with a compliance chamber [CC] connected, necessary for a pneumatic decoupling of both membranes and one open to atmosphere) and a BPX-80 as reference pump. The average modified index of hemolysis and normalized index of hemolysis (NIH in mg/100L) from six individual trials of the reference pump were 0.34 (0.07) and 3.21 (0.61) and of the TAH open to atmosphere 4.18 (1.19) and 38.85 (10.59), respectively. In between TAH with and without CC, there was no significant difference. A NIH ratio of TAH and reference pump was calculated to minimize variation of the different blood batches used in individual trials. Due to the downsizing, the ReinHeart's hemolysis level increased by around 22% compared with the original size version. Comparing the results to clinically approved left ventricular assist devices, the level of hemolysis can still be considered acceptable.


Asunto(s)
Corazón Artificial , Corazón Auxiliar , Animales , Gasto Cardíaco , Corazón Artificial/efectos adversos , Corazón Auxiliar/efectos adversos , Hemólisis , Diseño de Prótesis , Porcinos
19.
Artif Organs ; 46(3): 412-426, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34606117

RESUMEN

BACKGROUND: Membranes based on triply periodic minimal surfaces (TPMS) have proven a superior gas transfer compared to the contemporary hollow fiber membrane (HFM) design in artificial lungs. The improved oxygen transfer is attributed to disrupting the laminar boundary layer adjacent to the membrane surface known as main limiting factor to mass transport. However, it requires experimental proof that this improvement is not at the expense of greater damage to the blood. Hence, the aim of this work is a valid statement regarding the structure-dependent hemolytic behavior of TPMS structures compared to the current HFM design. METHODS: Hemolysis tests were performed on structure samples of three different kind of TPMS-based designs (Schwarz-P, Schwarz-D and Schoen's Gyroid) in direct comparison to a hollow fiber structure as reference. RESULTS: The results of this study suggest that the difference in hemolysis between TPMS membranes compared to HFMs is small although slightly increased for the TPMS membranes. There is no significant difference between the TPMS structures and the hollow fiber design. Nevertheless, the ratio between the achieved additional oxygen transfer and the additional hemolysis favors the TPMS-based membrane shapes. CONCLUSION: TPMS-shaped membranes offer a safe way to improve gas transfer in artificial lungs.


Asunto(s)
Órganos Artificiales , Hemólisis , Pulmón , Membranas Artificiales , Diseño de Equipo , Humanos , Impresión Tridimensional
20.
Cardiovasc Eng Technol ; 13(2): 318-330, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34532837

RESUMEN

PURPOSE: Extracorporeal membrane oxygenation has gained increasing attention in the treatment of patients with acute and chronic cardiopulmonary and respiratory failure. However, clotting within the oxygenators or other components of the extracorporeal circuit remains a major complication that necessitates at least a device exchange and bears risks of adverse events for the patients. In order to better predict thrombus growth within oxygenators, we present an approach for in-vitro visualization of thrombus growth using real-time X-ray imaging. METHODS: An in-vitro test setup was developed using low-dose anticoagulated ovine blood and allowing for thrombus growth within 4 h. The setup was installed in a custom-made X-ray setup that uses phase-contrast for imaging, thus providing enhanced soft-tissue contrast, which improves the differentiation between blood and potential thrombus growth. During experimentation, blood samples were drawn for the analysis of blood count, activated partial thromboplastin time and activated clotting time. Additionally, pressure and flow data was monitored and a full 360° X-ray scan was performed every 15 min. RESULTS: Thrombus formation indicated by a pressure drop and changing blood parameters was monitored in all three test devices. Red and white thrombi (higher/lower attenuation, respectively) were successfully segmented in one set of X-ray images. CONCLUSION: We showed the feasibility of a new in-vitro method for real-time thrombus growth visualization by means of phase contrast X-ray imaging. In addition, with more blood parameters that are clinically relevant, this approach might contribute to improved oxygenator exchange protocols in the clinical routine.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trombosis , Animales , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios de Factibilidad , Humanos , Pulmón , Oxigenadores de Membrana/efectos adversos , Ovinos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Rayos X