Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
3.
Vascular ; 18(1): 59-61, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20122364

RESUMEN

A 41-year-old woman was treated with a Figulla (Occlutec, Helsingborg, Sweden) atrial septum occluder device with no intraprocedural complications. Five months later, dislocation of the device in the abdominal aorta was detected. The occluder device was located at the level of the celiac axis, nearly obstructing the entire aorta. Owing to total incorporation of the device, endoluminal retrieval was not possible. Through a medial rotation approach, the device was safely removed. This is a rare complication after endoluminal closure of an atrial septum defect. The retrieval possibilities are discussed.


Asunto(s)
Aorta Abdominal/cirugía , Enfermedades de la Aorta/terapia , Cateterismo Cardíaco/instrumentación , Cateterismo Periférico , Embolia/terapia , Migración de Cuerpo Extraño/terapia , Defectos del Tabique Interatrial/terapia , Dispositivo Oclusor Septal , Procedimientos Quirúrgicos Vasculares , Adulto , Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/etiología , Aortografía/métodos , Cateterismo Cardíaco/efectos adversos , Remoción de Dispositivos , Embolia/diagnóstico por imagen , Embolia/etiología , Embolia/cirugía , Femenino , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/cirugía , Humanos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
J Interv Cardiol ; 22(6): 527-36, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19627430

RESUMEN

Coronary angiography, despite its inherent invasiveness and need for contrast media and radiographic exposure, is still routinely employed every year for the diagnostic and therapeutic management of millions of patients with or at risk for coronary artery disease. Whereas approximate visual estimation is the most common way to evaluate coronary angiography findings, since the late 1980s a number of investigators have developed and investigated methods of quantitative coronary angiography (QCA) analysis exploiting automated or semi-automated edge detection. Despite the inherent drawback of QCA due to its focus on the contrast-filled lumen of the vessel, QCA has offered and continues to offer important insights for clinical research and, in selected cases, clinical practice. This review aims thus to provide a comprehensive and updated viewpoint on the actual role of QCA.


Asunto(s)
Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico , Interpretación de Imagen Asistida por Computador/instrumentación , Angiografía Coronaria/tendencias , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Progresión de la Enfermedad , Stents Liberadores de Fármacos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Inmunosupresores/uso terapéutico , Sirolimus/uso terapéutico , Tomografía de Coherencia Óptica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA