Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
4.
Heliyon ; 8(5): e09320, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35540936

RESUMEN

The open repair of groin hernias is often augmented with prosthetic biomaterials (mesh) as this favours a lower recurrence rate. The use of such prostheses may be associated with various complications including migration the frequency of which is unclear. A 29-year review of this complication after mesh plug hernioplasty is undertaken and technical advice described to avoid this.

5.
JCI Insight ; 6(14)2021 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-34111030

RESUMEN

BACKGROUNDIndividuals recovering from COVID-19 frequently experience persistent respiratory ailments, which are key elements of postacute sequelae of SARS-CoV-2 infection (PASC); however, little is known about the underlying biological factors that may direct lung recovery and the extent to which these are affected by COVID-19 severity.METHODSWe performed a prospective cohort study of individuals with persistent symptoms after acute COVID-19, collecting clinical data, pulmonary function tests, and plasma samples used for multiplex profiling of inflammatory, metabolic, angiogenic, and fibrotic factors.RESULTSSixty-one participants were enrolled across 2 academic medical centers at a median of 9 weeks (interquartile range, 6-10 weeks) after COVID-19 illness: n = 13 participants (21%) had mild COVID-19 and were not hospitalized, n = 30 participants (49%) were hospitalized but were considered noncritical, and n = 18 participants (30%) were hospitalized and in the intensive care unit (ICU). Fifty-three participants (85%) had lingering symptoms, most commonly dyspnea (69%) and cough (58%). Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), and diffusing capacity for carbon monoxide (DLCO) declined as COVID-19 severity increased (P < 0.05) but these values did not correlate with respiratory symptoms. Partial least-squares discriminant analysis of plasma biomarker profiles clustered participants by past COVID-19 severity. Lipocalin-2 (LCN2), MMP-7, and HGF identified by our analysis were significantly higher in the ICU group (P < 0.05), inversely correlated with FVC and DLCO (P < 0.05), and were confirmed in a separate validation cohort (n = 53).CONCLUSIONSubjective respiratory symptoms are common after acute COVID-19 illness but do not correlate with COVID-19 severity or pulmonary function. Host response profiles reflecting neutrophil activation (LCN2), fibrosis signaling (MMP-7), and alveolar repair (HGF) track with lung impairment and may be novel therapeutic or prognostic targets.FundingNational Heart, Lung, and Blood Institute (K08HL130557 and R01HL142818), American Heart Association (Transformational Project Award), the DeLuca Foundation Award, a donation from Jack Levin to the Benign Hematology Program at Yale University, and Duke University.


Asunto(s)
COVID-19/complicaciones , Factor de Crecimiento de Hepatocito/análisis , Lipocalina 2/análisis , Metaloproteinasa 7 de la Matriz/análisis , Fibrosis Pulmonar , Pruebas de Función Respiratoria , COVID-19/diagnóstico , COVID-19/inmunología , COVID-19/fisiopatología , Tos/diagnóstico , Tos/etiología , Disnea/diagnóstico , Disnea/etiología , Femenino , Humanos , Pulmón/metabolismo , Pulmón/patología , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Activación Neutrófila/inmunología , Pronóstico , Fibrosis Pulmonar/diagnóstico , Fibrosis Pulmonar/etiología , Fibrosis Pulmonar/metabolismo , Recuperación de la Función/inmunología , Pruebas de Función Respiratoria/métodos , Pruebas de Función Respiratoria/estadística & datos numéricos , SARS-CoV-2 , Índice de Severidad de la Enfermedad , Síndrome Post Agudo de COVID-19
7.
medRxiv ; 2021 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-33564789

RESUMEN

INTRODUCTION: Subjects recovering from COVID-19 frequently experience persistent respiratory ailments; however, little is known about the underlying biological factors that may direct lung recovery and the extent to which these are affected by COVID-19 severity. METHODS: We performed a prospective cohort study of subjects with persistent symptoms after acute COVID-19, collecting clinical data, pulmonary function tests, and plasma samples used for multiplex profiling of inflammatory, metabolic, angiogenic, and fibrotic factors. RESULTS: Sixty-one subjects were enrolled across two academic medical centers at a median of 9 weeks (interquartile range 6-10) after COVID-19 illness: n=13 subjects (21%) mild/non-hospitalized, n=30 (49%) hospitalized/non-critical, and n=18 subjects (30%) hospitalized/intensive care ("ICU"). Fifty-three subjects (85%) had lingering symptoms, most commonly dyspnea (69%) and cough (58%). Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), and diffusing capacity for carbon monoxide (DLCO) declined as COVID-19 severity increased (P<0.05), but did not correlate with respiratory symptoms. Partial least-squares discriminant analysis of plasma biomarker profiles clustered subjects by past COVID-19 severity. Lipocalin 2 (LCN2), matrix metalloproteinase-7 (MMP-7), and hepatocyte growth factor (HGF) identified by the model were significantly higher in the ICU group (P<0.05) and inversely correlated with FVC and DLCO (P<0.05), and were confirmed in a separate validation cohort (n=53). CONCLUSIONS: Subjective respiratory symptoms are common after acute COVID-19 illness but do not correlate with COVID-19 severity or pulmonary function. Host response profiles reflecting neutrophil activation (LCN2), fibrosis signaling (MMP-7), and alveolar repair (HGF) track with lung impairment and may be novel therapeutic or prognostic targets. FUNDING: The study was funded in part by the NHLBI (K08HL130557 to BDK and R01HL142818 to HJC), the DeLuca Foundation Award (AP), a donation from Jack Levin to the Benign Hematology Program at Yale, and Divisional/Departmental funds from Duke University.

12.
Hernia ; 21(2): 151-152, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28236136
16.
Science ; 344(6183): 470, 2014 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-24786062
18.
World J Surg ; 37(4): 737-45, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23340707

RESUMEN

BACKGROUND: The use of sterilized mosquito net as a cheaper alternative to commercial mesh used in hernia repair has previously been published. However, as no standards with regard to the material have been documented, we aimed to define the characteristics of a commonly available and low-cost mosquito net, which has already been shown to be clinically efficacious in groin hernia repair. We compared its characteristics to other commercially available meshes, in keeping with the well-established FDA and MHRA regulatory processes. METHODS: The macromolecular structure of the mosquito net was determined by vibrational spectroscopy. The ultrastructure of the meshes was examined with scanning electron microscopy, and uniaxial and burst tensile strength testing was performed. The following parameters were assessed: polymer type, filament characteristics, pore size, weight, linear density, elasticity, and tensile strength. RESULTS: The mosquito net was a polyethylene homopolymer, knitted from monofilament fibers with a mean filament diameter of 109.7 µm and a mean mesh thickness of 480 µm. The mean pore maximum diameter was 1.9 mm, with 91.2 % porosity, 53.7 g/m(2) mean mesh weight, and a linear mass density of 152 denier. This was comparable to the "large pore" (class I) commercial meshes. The bursting force for polyethylene mosquito net was greater than for UltraPro and Vypro (43.0 vs. 35.5 and 27.2 N/cm, respectively), and the mosquito net exhibited less anisotropy compared to the commercial meshes. CONCLUSIONS: The material and mechanical properties of the polyethylene mosquito net are substantially equivalent to those of commonly used lightweight commercial meshes.


Asunto(s)
Herniorrafia/instrumentación , Fenómenos Mecánicos , Mosquiteros , Mallas Quirúrgicas , Elasticidad , Humanos , Microscopía Electrónica de Rastreo , Polietileno/química , Porosidad , Espectroscopía Infrarroja por Transformada de Fourier , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...