Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Radiat Prot Dosimetry ; 199(15-16): 1932-1936, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819324

RESUMEN

The problem of boron concentration monitoring during the boron neutron capture therapy (BNCT) therapy is one of the main challenges of this type of radiotherapy and is directly related to the nature of the interaction of neutrons with mater. Among the available in vivo methods of boron monitoring positron emission tomography seems to be very promising but it requires a new boron carrier with a ß+ emitter, which is not yet clinically available. An alternative solution may be the prompt gamma radiation analysis (PGRA) based on the secondary radiation emitted in the interaction of neutrons with the patient's tissues. This method requires, however, compact gamma radiation detection systems sustaining high counting rates and characterized by very good energy resolution. In this contribution, we present state-of-the-art solutions for monitoring in BNCT based on PGRA. Moreover, we describe a new concept of such a system based on position-sensitive scintillator detectors equipped with an anti-Compton shield and data analysis supported with modern artificial intelligence algorithms.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Humanos , Terapia por Captura de Neutrón de Boro/métodos , Boro , Rayos gamma , Inteligencia Artificial , Neutrones
2.
EJNMMI Phys ; 10(1): 62, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819578

RESUMEN

BACKGROUND: Alongside the benefits of Total-Body imaging modalities, such as higher sensitivity, single-bed position, low dose imaging, etc., their final construction cost prevents worldwide utilization. The main aim of this study is to present a simulation-based comparison of the sensitivities of existing and currently developed tomographs to introduce a cost-efficient solution for constructing a Total-Body PET scanner based on plastic scintillators. METHODS: For the case of this study, eight tomographs based on the uEXPLORER configuration with different scintillator materials (BGO, LYSO), axial field-of-view (97.4 cm and 194.8 cm), and detector configurations (full and sparse) were simulated. In addition, 8 J-PET scanners with different configurations, such as various axial field-of-view (200 cm and 250 cm), different cross sections of plastic scintillator, and multiple numbers of plastic scintillator layers (2, 3, and 4), based on J-PET technology have been simulated by GATE software. Furthermore, Siemens' Biograph Vision has been simulated to compare the results with standard PET scans. Two types of simulations have been performed. The first one with a centrally located source with a diameter of 1 mm and a length of 250 cm, and the second one with the same source inside a water-filled cylindrical phantom with a diameter of 20 cm and a length of 183 cm. RESULTS: With regards to sensitivity, among all the proposed scanners, the ones constructed with BGO crystals give the best performance ([Formula: see text] 350 cps/kBq at the center). The utilization of sparse geometry or LYSO crystals significantly lowers the achievable sensitivity of such systems. The J-PET design gives a similar sensitivity to the sparse LYSO crystal-based detectors while having full detector coverage over the body. Moreover, it provides uniform sensitivity over the body with additional gain on its sides and provides the possibility for high-quality brain imaging. CONCLUSION: Taking into account not only the sensitivity but also the price of Total-Body PET tomographs, which till now was one of the main obstacles in their widespread clinical availability, the J-PET tomography system based on plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners.

3.
EJNMMI Phys ; 10(1): 28, 2023 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-37029849

RESUMEN

BACKGROUND: The Jagiellonian Positron Emission Tomograph is the 3-layer prototype of the first scanner based on plastic scintillators, consisting of 192 half-metre-long strips with readouts at both ends. Compared to crystal-based detectors, plastic scintillators are several times cheaper and could be considered as a more economical alternative to crystal scintillators in future PETs. JPET is also a first multi-photon PET prototype. For the development of multi-photon detection, with photon characterized by the continuous energy spectrum, it is important to estimate the efficiency of J-PET as a function of energy deposition. The aim of this work is to determine the registration efficiency of the J-PET tomograph as a function of energy deposition by incident photons and the intrinsic efficiency of the J-PET scanner in detecting photons of different incident energies. In this study, 3-hit events are investigated, where 2-hits are caused by 511 keV photons emitted in [Formula: see text] annihilations, while the third hit is caused by one of the scattered photons. The scattered photon is used to accurately measure the scattering angle and thus the energy deposition. Two hits by a primary and a scattered photon are sufficient to calculate the scattering angle of a photon, while the third hit ensures the precise labeling of the 511 keV photons. RESULTS: By comparing experimental and simulated energy distribution spectra, the registration efficiency of the J-PET scanner was determined in the energy deposition range of 70-270 keV, where it varies between 20 and 100[Formula: see text]. In addition, the intrinsic efficiency of the J-PET was also determined as a function of the energy of the incident photons. CONCLUSION: A method for determining registration efficiency as a function of energy deposition and intrinsic efficiency as a function of incident photon energy of the J-PET scanner was demonstrated. This study is crucial for evaluating the performance of the scanner based on plastic scintillators and its applications as a standard and multi-photon PET systems. The method may be also used in the calibration of Compton-cameras developed for the ion-beam therapy monitoring and simultaneous multi-radionuclide imaging in nuclear medicine.

4.
Nat Commun ; 12(1): 5658, 2021 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-34580294

RESUMEN

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10-4, with an over threefold improvement on the previous measurement.

5.
Phys Med Biol ; 66(17)2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34289460

RESUMEN

The purpose of the presented research is estimation of the performance characteristics of the economic total-body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with cross section of 6 mm times 30 mm and length of 140 or 200 cm) arranged in two layers in regular 24-sided polygon circumscribing a circle with the diameter of 78.6 cm. For the TB-J-PET with an axial field-of-view (AFOV) of 200 cm, a spatial resolutions (SRs) of 3.7 mm (transversal) and 4.9 mm (axial) are achieved. The noise equivalent count rate (NECR) peak of 630 kcps is expected at 30 kBq cc-1. Activity concentration and the sensitivity at the center amounts to 38 cps kBq-1. The scatter fraction (SF) is estimated to 36.2 %. The values of SF and SR are comparable to those obtained for the state-of-the-art clinical PET scanners and the first total-body tomographs: uExplorer and PennPET. With respect to the standard PET systems with AFOV in the range from 16 to 26 cm, the TB-J-PET is characterized by an increase in NECR approximately by factor of 4 and by the increase of the whole-body sensitivity by factor of 12.6 to 38. The time-of-flight resolution for the TB-J-PET is expected to be at the level of CRT = 240 ps full width at half maximum. For the TB-J-PET with an AFOV of 140 cm, an image quality of the reconstructed images of a NEMA IEC phantom was presented with a contrast recovery coefficient and a background variability parameters. The increase of the whole-body sensitivity and NECR estimated for the TB-J-PET with respect to current commercial PET systems makes the TB-J-PET a promising cost-effective solution for the broad clinical applications of total-body PET scanners. TB-J-PET may constitute an economic alternative for the crystal TB-PET scanners, since plastic scintillators are much cheaper than BGO or LYSO crystals and axial arrangement of the strips significantly reduces the costs of readout electronics and SiPMs.


Asunto(s)
Plásticos , Tomografía de Emisión de Positrones , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
6.
Phys Med ; 80: 230-242, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33190079

RESUMEN

In this paper we introduce a semi-analytic algorithm for 3-dimensional image reconstruction for positron emission tomography (PET). The method consists of the back-projection of the acquired data into the most likely image voxel according to time-of-flight (TOF) information, followed by the filtering step in the image space using an iterative optimization algorithm with a total variation (TV) regularization. TV regularization in image space is more computationally efficient than usual iterative optimization methods for PET reconstruction with full system matrix that use TV regularization. The efficiency comes from the one-time TOF back-projection step that might also be described as a reformatting of the acquired data. An important aspect of our work concerns the evaluation of the filter operator of the linear transform mapping an original radioactive tracer distribution into the TOF back-projected image. We obtain concise, closed-form analytical formula for the filter operator. The proposed method is validated with the Monte Carlo simulations of the NEMA IEC phantom using a one-layer, 50 cm-long cylindrical device called Jagiellonian PET scanner. The results show a better image quality compared with the reference TOF maximum likelihood expectation maximization algorithm.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía de Emisión de Positrones , Algoritmos , Imagenología Tridimensional , Fantasmas de Imagen
7.
EJNMMI Phys ; 7(1): 44, 2020 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-32607664

RESUMEN

PURPOSE: In living organisms, the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511 keV photons. In this article, we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include the (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using 2γ annihilations and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. METHODS: Simulations are conducted assuming that radiopharmaceutical is labeled with 44Sc isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution, the four cases were considered assuming that CRT is equal to 500 ps, 140 ps, 50 ps, and 10 ps. RESULTS: The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences (2γ+γprompt) is larger by a factor of 13.5 (for LYSO PET) and by factor of 5.2 (for plastic PET) with respect to the sensitivity for the standard 2γ imaging by LYSO PET scanners with AFOV = 20 cm. The spatial resolution of the ortho-positronium image is comparable with the resolution achievable when using TOF-FBP algorithms already for CRT = 50 ps. For the 20-min scan, the resolution better than 20 ps is expected for the mean ortho-positronium lifetime image determination. CONCLUSIONS: Ortho-positronium mean lifetime imaging based on the annihilations into two photons and prompt gamma is shown to be feasible with the advent of the high sensitivity total-body PET systems and time resolution of the order of tens of picoseconds.

8.
EJNMMI Phys ; 7(1): 39, 2020 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-32504254

RESUMEN

PURPOSE: The time-over-threshold (TOT) technique is being used widely due to itsimplications in developing the multi-channel readouts, mainly when fast signal processing is required. Using the TOT technique, as a measure of energy loss instead of charge integration methods, significantly reduces the signal readout costs by combining the time and energy information. Therefore, this approach can potentially be utilized in J-PET tomograph which is built from plastic scintillators characterized by fast light signals. The drawback in adopting this technique lies in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it by the J-PET tomograph setup. METHODS: The experiment was performed using a 22Na beta emitter source placed in the center of the J-PET tomograph. This isotope produces photons of two different energies: 511 keV photons from the positron annihilation (direct annihilation or through the formation of a para-positronium atom or pick-off process of ortho-positronium atoms) and a 1275 keV prompt photon. This allows the study of the correlation between TOT values and energy loss for energy ranges up to 1000 keV. Since the photon interacts predominantly via Compton scattering inside the plastic scintillator, there is no direct information of the energy deposition. However, using the J-PET geometry, one can measure the scattering angle of the interacting photon. Since the 22Na source emits photons of two different energies, it is necessary to know unambiguously the energy of incident photons and their corresponding scattering angles in order to estimate energy deposition. In summary, this work presents a dedicated algorithm developed to tag photons of different energies and studying their scattering angles to calculate the energy deposition by the interacting photons. RESULTS: A new method was elaborated to measure the energy loss by photons interacting with plastic scintillators used in the J-PET tomograph. We find the relationship between the energy loss and TOT is non-linear and can be described by the functions TOT = A0 + A1 * ln(E dep + A2) + A3 * (ln(E dep + A2))2 and TOT = A0 - A1 * A2[Formula: see text]. In addition, we also introduced a theoretical model to calculate the TOT as a function of energy loss in plastic scintillators. CONCLUSIONS: A relationship between TOT and energy loss by photons interacting inside the plastic scintillators used in J-PET scanner is established for a deposited energy range of 100-1000 keV.

9.
Phys Med Biol ; 64(5): 055017, 2019 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-30641509

RESUMEN

A detection system of the conventional PET tomograph is set-up to record data from [Formula: see text] annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in point-like sources and in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of ∼40 ps. Recent positron annihilation lifetime spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.


Asunto(s)
Electrones , Tomografía de Emisión de Positrones/métodos , Estudios de Factibilidad , Fantasmas de Imagen
10.
J Physiol Pharmacol ; 69(6)2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30802218

RESUMEN

Recently, the proteomic analysis has become an ideal tool to study the structure and function of platelets. We proposed a nano-liquid chromatography (nano-LC) technique coupled off-line with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/TOF-MS) for rat platelet proteome analysis. In this study, we attempted to analyze the rat platelet proteome in two different subcellular fractions: cytosol and membrane. Platelet-rich plasma was collected from healthy rats. The platelet samples were extracted with Subcellular Proteome Extraction Kit to collect subcellular compartments. For further investigations, platelet lysate, cytosol and membrane fractions were used. Enzymatic digestion of proteins was performed using Filter Aided Sample Preparation method with trypsin as a proteolytic enzyme. Tryptic peptides were analyzed using nano-LC-MALDI-TOF/TOF-MS. Platelet proteins identification was performed using the Mascot engine. We identified 238 proteins in the platelet lysate, 210 in the cytosol, and 148 in the membrane fraction. Among them, 45 were unique for platelet lysate, 55 for cytosol, and 34 for the membrane fraction. The gene ontology analysis showed that there were differences in the proteome of cytosol and membrane fractions related to the molecular functions, i.e. coagulative activity. Our results may suggest that the membrane or cytosol location of the proteins with coagulative activity may be responsible for the acute or delayed platelet response to an agonist. The nano-LC-MALDI-TOF/TOF-MS method can be used for identifying proteins of subcellular fraction in rat platelets.


Asunto(s)
Plaquetas/metabolismo , Cromatografía Liquida/métodos , Proteoma/metabolismo , Proteómica/métodos , Animales , Membrana Celular/metabolismo , Citosol/metabolismo , Masculino , Péptidos/metabolismo , Ratas , Ratas Wistar , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Fracciones Subcelulares/metabolismo
12.
J Endocrinol ; 208(1): 81-8, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20962013

RESUMEN

Suppressors of cytokine signalling (SOCS) negatively regulate cytokine-induced signalling pathways and may be involved in leptin and prolactin (PRL) interactions. Herein, we examined the effect of PRL on SOCS-3 mRNA expression in pituitary explants and investigated whether leptin could modify the expression of SOCS-3 mRNA in pituitary explants. In the first experiment, we used pituitaries isolated from 16 ewes decapitated in March, May, July and October (four per month). Tissues were cut into 50 mg explants, which were treated with control or medium containing PRL (100 or 300 ng/ml). Incubation was maintained for different time intervals: 0, 60, 120, 180, 240 or 300 min. Real-time PCR was used to measure SOCS-3 mRNA levels. In the second study, we used 24 ewes surgically fitted with third ventricle cannulas (12 were used during the long-day period, and 12 were used during the short-day (SD) period). Each ewe was administered an i.c.v. injection of Ringer-Locke buffer or leptin (0.5 or 1.0 µg/kg body weight). Explants of anterior pituitaries were collected and snap frozen 1 h after injection. Semi-quantitative expression of SOCS-3 mRNA was performed using reverse transcription-PCR. PRL stimulated SOCS-3 expression in the pituitaries collected in March (P<0.05) and May (P<0.01 and P<0.05 for lower and higher doses respectively), inhibited SOCS-3 expression in pituitaries collected in July (P<0.01) and had no effect in pituitaries collected in October. Treatment with leptin increased SOCS-3 expression during the SDs in a dose-dependent manner (P<0.01). The results demonstrated that photoperiod may be involved in leptin and PRL effects on SOCS-3 expression in sheep.


Asunto(s)
Leptina/administración & dosificación , Hipófisis/efectos de los fármacos , Prolactina/administración & dosificación , Estaciones del Año , Proteínas Supresoras de la Señalización de Citocinas/genética , Análisis de Varianza , Animales , Relación Dosis-Respuesta a Droga , Femenino , Inyecciones Intraventriculares , Hipófisis/metabolismo , ARN Mensajero/genética , ARN Mensajero/metabolismo , Radioinmunoensayo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Ovinos , Proteínas Supresoras de la Señalización de Citocinas/metabolismo , Técnicas de Cultivo de Tejidos
13.
Ann Clin Biochem ; 47(Pt 4): 343-9, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20592333

RESUMEN

BACKGROUND: The interleukin-6 (IL-6) promoter -174G/C polymorphism (rs1800795) is associated with enhanced systemic inflammatory response to injury. However, data on the effect of this polymorphism on inflammatory markers in patients undergoing coronary artery bypass grafting surgery (CABG) are inconsistent. The aim of our study was to investigate whether -174G/C IL-6 polymorphism affects plasma IL-6 and C-reactive protein (CRP) concentrations in patients undergoing CABG. METHODS: A total of 179 consecutive white patients (77% men, aged 65 +/- 8.6 standard deviation [SD] y) scheduled for elective isolated CABG were studied. Pre- and postoperative CRP and IL-6 levels were analysed in relation to the 174G/C IL-6 polymorphism determined by using TaqMan single-nucleotide polymorphism genotyping technique. RESULTS: The genotype distribution was as follows: GG -46 (26%), GC -93 (52%) and CC -40 (22%). The C allele carriers had higher baseline CRP (4.1 +/- 0.35 versus 2.4 +/- 0.59 mg/L, P = 0.02) and IL-6 levels (3.0 +/- 0.17 versus 2.2 +/- 0.3 pg/mL, P = 0.02) than GG patients. Five to seven days after CABG, CRP levels rose by 54% (P = 0.03), and IL-6 levels tended to be higher (P = 0.07) in -174C allele carriers than the non-carriers. There were no associations between -174G/C IL-6 polymorphism and any demographic-, clinical- or procedure-related variables as well as major adverse cardiovascular events. Multivariate regression analysis, including sex, age, body mass index, hypercholesterolaemia, smoking, hypertension diabetes, identified CG + CC genotype as the only independent predictor of preoperative CRP and IL-6 levels. CONCLUSIONS: The presence of the -174C allele determines to some extent higher plasma CRP and IL-6 concentrations pre- and postoperatively in CABG patients.


Asunto(s)
Proteína C-Reactiva/metabolismo , Puente de Arteria Coronaria , Interleucina-6/sangre , Interleucina-6/genética , Polimorfismo de Nucleótido Simple/genética , Adulto , Anciano , Anciano de 80 o más Años , Puente de Arteria Coronaria/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Perioperatorio , Periodo Posoperatorio , Análisis de Regresión
14.
J Appl Genet ; 50(4): 399-403, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19875892

RESUMEN

A daily dose of vitamin K antagonists (VKAs) may vary and its range depends on various interrelated factors. Low responsiveness to VKA (defined as a failure to achieve a target international normalized ratio [INR]) is associated with polymorphisms of the vitamin K epoxide reductase-oxidase complex gene (VKORC1). A highly prevalent promoter single-nucleotide polymorphism (VKORC1-1639 G>A, rs17878363) impairs VKORC1 expression and determines the interindividual variability of the target INR. We studied 57 patients receiving oral anticoagulation, including 50 subjects treated with acenocoumarol (mean dose: 5.7+/-2.3 mg/day) and 7 treated with warfarin (mean dose: 9.6+/-4.2 mg/day). The indications for the use of oral anticoagulant therapy were as follows: deep-vein thrombosis (N = 23); pulmonary embolism (N = 20); arterial thrombosis (N = 5); stroke (N = 4); atrial fibrillation with transient ischemic attacks (N = 2), and history of multiple thromboembolic events (N = 3). Identification of the VKORC1 genomic variation was performed using DNA sequencing methods. The prevalence of the mutated allele (VKORC1 -1639A) was 41%. The VKORC1 -1639G allele carriers required a higher daily dose of acenocoumarol (5.9+/-1.9 mg) than the noncarriers (4.1+/-3.3 mg; P < 0.001). All of 5 low responders (who failed to achieve a target INR using standard dose requirements of VKAs) were homozygous for the 1639G allele. Low responders did not differ from good responders with respect to age, gender, and body mass index. Our findings suggest the potential benefits from pharmacogenetic testing, and provide evidence that the VKORC1 -1639 G>A gene polymorphism may explain at least in part the low responsiveness to acenocoumarol.


Asunto(s)
Anticoagulantes/administración & dosificación , Oxigenasas de Función Mixta/genética , Polimorfismo de Nucleótido Simple , Vitamina K/antagonistas & inhibidores , Acenocumarol/administración & dosificación , Adulto , Alelos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/enzimología , Fibrilación Atrial/genética , Secuencia de Bases , Cartilla de ADN/genética , Relación Dosis-Respuesta a Droga , Resistencia a Medicamentos/genética , Femenino , Frecuencia de los Genes , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Polonia , Regiones Promotoras Genéticas , Embolia Pulmonar/tratamiento farmacológico , Embolia Pulmonar/enzimología , Embolia Pulmonar/genética , Trombosis de la Vena/tratamiento farmacológico , Trombosis de la Vena/enzimología , Trombosis de la Vena/genética , Vitamina K Epóxido Reductasas , Warfarina/administración & dosificación
15.
J Endocrinol ; 198(1): 147-55, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18451065

RESUMEN

Recent studies have demonstrated photoperiodic changes in leptin sensitivity of seasonal mammals. Herein, we examined the interaction of season (long days (LD) versus short days (SD)) and recombinant ovine leptin (roleptin) on secretion of melatonin and prolactin (PRL) and on mRNA expression of suppressor of cytokine signaling-3 (SOCS-3) in the medial basal hypothalamus (MBH) in sheep. Twenty-four Polish Longwool ewes, surgically fitted with third ventricle (IIIV) cannulas, were utilized in a replicated switchback design involving 12 ewes per season. Within-season and replicate ewes were assigned randomly to one of three treatments (four ewes/treatment) and infused centrally three times at 0, 1 and 2 h beginning at sunset. Treatments were 1) control, Ringer-Locke buffer; 2) L1, roleptin, 0.5 microg/kg BW; and 3) L2, roleptin, 1.0 microg/kg BW. Jugular blood samples were collected at 15-min intervals beginning immediately before the start of infusions and continued for 6 h. At the end of blood sampling, a washout period of at least 3 days elapsed before ewes were re-randomized and treated with one of the treatments described above (four ewes/treatment). Ewes were then killed and brains were collected for MBH processing. Leptin treatments increased (P<0.001) circulating leptin concentrations compared with controls during both seasons in a dose-dependent manner. Overall, mean plasma concentrations of melatonin were greater (P<0.001) during LD than SD. However, leptin treatments increased melatonin concentrations during SD in a dose-dependent manner and decreased it during LD. Similarly, plasma concentrations of PRL were greater (P<0.001) during LD than SD. However, unlike changes in melatonin, circulating PRL decreased (P<0.001) in response to leptin during LD. Semi-quantitative PCR revealed that leptin increased (P<0.001) SOCS-3 expression in the MBH region during LD in a dose-dependent manner. Data provide evidence that secretion of photoperiodic hormones such as melatonin and PRL are inversely regulated by leptin during SD and LD. However, the increase in expression of SOCS-3 in the MBH during LD compared with SD fails to fully explain these effects.


Asunto(s)
Encéfalo/efectos de los fármacos , Leptina/farmacología , Melatonina/metabolismo , Prolactina/metabolismo , Proteínas Supresoras de la Señalización de Citocinas/genética , Animales , Relación Dosis-Respuesta a Droga , Femenino , Hipotálamo/metabolismo , Leptina/administración & dosificación , Leptina/sangre , Melatonina/sangre , Prolactina/sangre , Estaciones del Año , Ovinos
19.
Med Sci Monit ; 7(5): 995-1001, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11535948

RESUMEN

BACKGROUND: Seroepidemiological, pathological and animal studies suggest that chronic infection with Chlamydia pneumoniae (Cp) may directly impact the development or progression of atherosclerosis and coronary heart disease. The aim of the present study was to determine the seroprevalence of Cp infection and markers of systemic inflammation in patients undergoing routine coronary artery examination and prior to heart revascularization. MATERIAL AND METHODS: The research involved 76 patients with severe CAD and 81 control patients with normal coronary circulation confirmed by coronary angiography. The presence of serum IgG and IgA antibodies to Cp and plasma interleukin-8 (IL-8) levels was measured by EIA test. Furthermore, the levels of plasma C-reactive protein, fibrinogen, total cholesterol, and triglycerides were measured in all patients. RESULTS: Seropositivity to Cp was found in 60.5% for IgG and in 61.8% of cases for IgA with CAD patients, as compared to 26.0% and 29.5% in the controls (p<0.001), respectively. The levels of Interleukin-8, plasma fibrinogen, total cholesterol and triglycerides were significantly higher (p<0.001) in the CAD group, while C-reactive protein tended to have a higher value in patients with atherosclerosis than in the control group, although the difference was not significant. CONCLUSIONS: Cp infection significantly increases the risk of CAD, usually requiring coronary bypass surgery or percutaneous coronary intervention as effective measures. It may also modify the levels of serum lipids, CRP and fibrinogen, increasing the risk of atherosclerosis. The strong correlation between the elevated IgG and IgA titers of Cp in patients treated with angioplasty or surgery may impact their follow-up; this issue requires further investigation.


Asunto(s)
Infecciones por Chlamydia/epidemiología , Chlamydophila pneumoniae , Enfermedad de la Arteria Coronaria/microbiología , Adulto , Anciano , Angioplastia , Anticuerpos Antibacterianos/sangre , Arterias/microbiología , Arterias/patología , Proteína C-Reactiva/metabolismo , Infecciones por Chlamydia/sangre , Chlamydophila pneumoniae/inmunología , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/cirugía , Circulación Coronaria , Fibrinógeno/metabolismo , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Interleucina-8/sangre , Persona de Mediana Edad
20.
Folia Med Cracov ; 42(4): 263-71, 2001.
Artículo en Polaco | MEDLINE | ID: mdl-12815787

RESUMEN

UNLABELLED: We studied plasma levels of troponin I (cTnI), troponin T (cTnT), creatine kinase MB (CKMBmass) and myoglobin (MB) in patients undergoing coronary artery bypass surgery with extracorporeal circulation and cardioplegia. In group 1 (25 patients without perioperative myocardial infarction) plasma levels of all markers studied were elevated after operation. In group 2 (24 patients with perioperative myocardial infarction) plasma concentrations of all markers exceeded several times levels observed in patients without myocardial infarction with maximal value for MB at 12 hours after operation; for cTnI and CKMBmass at 16 hours after surgery and for cTnT at 32 hours after the end of operation. ROC curves show cut-off value for CKMBmass 20.3 ng/ml (sensitivity 79% and specificity 89%); for cTnI cut-off value was 0.8 ng/ml (sensitivity 80% and specificity 94%) for cTnT the cut-off value was 0.41 ng/ml (sensitivity 86% and specificity 88%) and for MB the cut-off value was 419 ng/ml (sensitivity 85% and specificity 70%). CONCLUSION: All markers studied are reliable biochemical tests for perioperative myocardial infarction, however, the analysis of ROC curves suggested that cTnI and cTnT might be more useful for diagnosis of perioperative myocardial infarction after conventional coronary artery bypass surgery.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Creatina Quinasa/sangre , Isoenzimas/sangre , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Mioglobina/análisis , Troponina I/análisis , Troponina T/análisis , Anciano , Biomarcadores/sangre , Forma MB de la Creatina-Quinasa , Circulación Extracorporea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/prevención & control , Mioglobina/sangre , Atención Perioperativa , Cuidados Posoperatorios , Troponina I/sangre , Troponina T/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...