Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Sci Rep ; 13(1): 22656, 2023 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-38114509

RESUMEN

Heart failure (HF) presents manifestations in both cardiac and vascular abnormalities. Pulmonary hypertension (PH) is prevalent in up 50% of HF patients. While pulmonary arterial hypertension (PAH) is closely associated with pulmonary artery (PA) stiffness, the association of HF caused, post-capillary PH and PA stiffness is unknown. We aimed to assess and compare PA stiffness and blood flow hemodynamics noninvasively across HF entities and control subjects without HF using CMR. We analyzed data of a prospectively conducted study with 74 adults, including 55 patients with HF across the spectrum (20 HF with preserved ejection fraction [HFpEF], 18 HF with mildly-reduced ejection fraction [HFmrEF] and 17 HF with reduced ejection fraction [HFrEF]) as well as 19 control subjects without HF. PA stiffness was defined as reduced vascular compliance, indicated primarily by the relative area change (RAC), altered flow hemodynamics were detected by increased flow velocities, mainly by pulse wave velocity (PWV). Correlations between the variables were explored using correlation and linear regression analysis. PA stiffness was significantly increased in HF patients compared to controls (RAC 30.92 ± 8.47 vs. 50.08 ± 9.08%, p < 0.001). PA blood flow parameters were significantly altered in HF patients (PWV 3.03 ± 0.53 vs. 2.11 ± 0.48, p < 0.001). These results were consistent in all three HF groups (HFrEF, HFmrEF and HFpEF) compared to the control group. Furthermore, PA stiffness was associated with higher NT-proBNP levels and a reduced functional status. PA stiffness can be assessed non-invasively by CMR. PA stiffness is increased in HFrEF, HFmrEF and HFpEF patients when compared to control subjects.Trial registration The study was registered at the German Clinical Trials Register (DRKS, registration number: DRKS00015615).


Asunto(s)
Insuficiencia Cardíaca , Adulto , Humanos , Arteria Pulmonar/diagnóstico por imagen , Análisis de la Onda del Pulso , Volumen Sistólico/fisiología , Espectroscopía de Resonancia Magnética , Pronóstico
2.
Am J Cardiovasc Dis ; 13(2): 73-86, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37213319

RESUMEN

AIMS: No data is available about the significance of cardiovascular magnetic resonance (CMR) derived vascular distensibility (VD) and vessel wall ratio (VWR) for risk stratification in patients with type 2 diabetes mellitus (T2DM). Therefore, this study aimed to investigate the effects of T2DM on VD and VWR using CMR in both central and peripheral territories. METHODS: Thirty-one T2DM-patients and nine controls underwent CMR. Angulation of the aorta, the common carotid, and the coronary arteries was performed to obtain cross-sectional vessel areas. RESULTS: In T2DM the Carotid-VWR and the Aortic-VWR correlated significantly. Mean values of Carotid-VWR and Aortic-VWR were significantly higher in T2DM than in controls. Coronary-VD was significantly lower in T2DM than in controls. No significant difference in Carotid-VD or Aortic-VD in T2DM vs. controls, respectively, could be observed. In a subgroup of thirteen T2DM patients with coronary artery disease (CAD), Coronary-VD was significantly lower and Aortic-VWR was significantly higher compared to T2DM patients without CAD. CONCLUSION: CMR allows a simultaneous evaluation of the structure and function of three important vascular territories to detect vascular remodeling in T2DM.

4.
Front Cardiovasc Med ; 8: 645693, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33829049

RESUMEN

Aims: Aortic valve replacement (AVR) may result in reverse cardiac remodeling. We aimed to assess long-term changes in the myocardium following AVR by Cardiac Magnetic Resonance Imaging (CMR). Methods: We prospectively observed the long-term left ventricular (LV) function and structure of 27 patients with AVR [n = 19 with aortic stenosis (AS); n = 8 with aortic regurgitation (AR)] by CMR. Patients underwent CMR before, as well as 1, 5, and 10 years after AVR. We evaluated clinical parameters, LV volumes, mass, geometry, ejection fraction (EF), global myocardial longitudinal strain (MyoGLS), global myocardial circular strain (MyoGCS), hemodynamic forces (HemForces), and Late Gadolinium Enhancement (LGE). Results: The median of LVMI, EDVI, and ESVI decreased in both groups. Patients with AR had higher initial values of EDVI and ESVI and showed a more prominent initial reduction. In AS, MyoGLS improved already after 1 year and remained constant afterward, whereas, in AR no improvement of MyoGLS was found. MyoGCS remained unchanged in the AS group but deteriorated in the AR group over 10 years. Ejection fraction (EF) was higher in AS patients compared to AR 10 years post-AVR. Late gadolinium enhancement (LGE) could be found more frequently in AS patients. Conclusion: CMR was well suited to investigate myocardial changes over a 10-year follow up period in patients with aortic valve disease. Regarding the long-term functional changes following AVR, patients with AR seemed to benefit less from AVR compared to AS patients. Fibrosis was more common in AS, but this did not reflect functional evolution in these patients. Close monitoring seems indispensable to avoid irreversible structural damage of the heart and to perform AVR at an appropriate stage.

5.
Front Immunol ; 11: 575635, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33692775
6.
Clin Res Cardiol ; 109(4): 454-464, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31302712

RESUMEN

OBJECTIVE: Aortic distensibility (AD) represents a well-established parameter of aortic stiffness. It remains unclear, however, whether AD can be obtained with high reproducibility in standard 4-chamber cine CMR images of the descending aorta. This study investigated the intra- and inter-observer agreement of AD based on different angles of the aorta and provided a sample size calculation of AD for future trials. METHODS: Thirty-one patients underwent CMR. Angulation of the descending aorta was performed to obtain strictly transversal and orthogonal cross-sectional aortic areas. AD was obtained both area and diameter based. RESULTS: For area-based values, inter-observer agreement was highest for 4-chamber AD (ICC 0.97; 95% CI 0.93-99), followed by orthogonal AD (ICC 0.96; 95% CI 0.91-98) and transversal AD (ICC 0.93; 95% CI 0.80-97). For diameter-based values, agreement was also highest for 4-chamber AD (ICC 0.97; 95% CI 0.94-99), followed by orthogonal AD (ICC 0.96; 95% CI 0.92-98) and transversal AD (ICC 0.91; 95% CI 0.77-96). Bland-Altman plots confirmed a small variation among observers. Sample size calculation showed a sample size of 12 patients to detect a change in 4-chamber AD of 1 × 10-3 mmHg-1 with either the area or diameter approach. CONCLUSION: AD measurements are highly reproducible and allow an accurate and rapid assessment of arterial compliance from standard 4-chamber cine CMR.


Asunto(s)
Aorta/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Rigidez Vascular , Aorta/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
9.
BMC Cardiovasc Disord ; 19(1): 52, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-30836942

RESUMEN

BACKGROUND: Recently introduced fast strain-encoded (SENC) cardiac magnetic resonance (CMR) imaging (fast-SENC) provides real-time acquisition of myocardial performance in a single heartbeat. We aimed to test the ability and accuracy of real-time strain-encoded CMR imaging to estimate left ventricular volumes, ejection fraction and mass. METHODS: Thirty-five subjects (12 healthy volunteers and 23 patients with known or suspected coronary artery disease) were investigated. All study participants were imaged at 1.5 Tesla MRI scanner (Achieva, Philips) using an advanced CMR study protocol which included conventional cine and fast-SENC imaging. A newly developed real-time free-breathing SENC imaging technique based on the acquisition of two images with different frequency modulation was employed. RESULTS: All parameters were successfully derived from fast-SENC images with total study time of 105 s (a 15 s scan time and a 90 s post-processing time). There was no significant difference between fast-SENC and cine imaging in the estimation of LV volumes and EF, whereas fast-SENC underestimated LV end-diastolic mass by 7%. CONCLUSION: The single heartbeat fast-SENC technique can be used as a good alternative to cine imaging for the precise calculation of LV volumes and ejection fraction while the technique significantly underestimates LV end-diastolic mass.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Anciano , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Disfunción Ventricular Izquierda/fisiopatología , Flujo de Trabajo , Adulto Joven
11.
Sci Rep ; 8(1): 14100, 2018 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-30237411

RESUMEN

Myocardial strain is a well validated parameter for estimating left ventricular (LV) performance. The aim of our study was to evaluate the inter-study as well as intra- and interobserver reproducibility of fast-SENC derived myocardial strain. Eighteen subjects (11 healthy individuals and 7 patients with heart failure) underwent a cardiac MRI examination including fast-SENC acquisition for evaluating left ventricular global longitudinal (GLS) and circumferential strain (GCS) as well as left ventricular ejection fraction (LVEF). The examination was repeated after 63 [range 49‒87] days and analyzed by two experienced observers. Ten datasets were repeatedly assessed after 1 month by the same observer to test intraobserver variability. The reproducibility was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Patients with heart failure demonstrated reduced GLS and GCS compared to healthy controls (-15.7 ± 3.7 vs. -20.1 ± 1.4; p = 0.002 for GLS and -15.3 ± 3.7 vs. -21.4 ± 1.1; p = 0.001 for GCS). The test-retest analysis showed excellent ICC for LVEF (0.92), GLS (0.94) and GCS (0.95). GLS exhibited excellent ICC (0.99) in both intra- and interobserver variability analysis with very narrow limits of agreement (-0.6 to 0.5 for intraobserver and -1.3 to 0.96 for interobserver agreement). Similarly, GCS showed excellent ICC (0.99) in both variability analyses with narrow limits of agreement (-1.1 to 1.2 for intraobserver and -1.7 to 1.3 for interobserver agreement), whereas LVEF showed larger limits of agreement (-14.4 to 10.1). The analysis of fast-SENC derived myocardial strain using cardiac MRI provides a highly reproducible method for assessing LV functional performance.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Corazón/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Miocardio , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
12.
Clin Res Cardiol ; 107(8): 642-652, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29520698

RESUMEN

Renal sympathetic denervation (RDN) is under investigation as a treatment option in patients with resistant hypertension (RH). Determinants of arterial compliance may, however, help to predict the BP response to therapy. Aortic distensibility (AD) is a well-established parameter of aortic stiffness and can reliably be obtained by CMR. This analysis sought to investigate the effects of RDN on AD and to assess the predictive value of pre-treatment AD for BP changes. We analyzed data of 65 patients with RH included in a multicenter trial. RDN was performed in all participants. A standardized CMR protocol was utilized at baseline and at 6-month follow-up. AD was determined as the change in cross-sectional aortic area per unit change in BP. Office BP decreased significantly from 173/92 ± 24/16 mmHg at baseline to 151/85 ± 24/17 mmHg (p < 0.001) 6 months after RDN. Maximum aortic areas increased from 604.7 ± 157.7 to 621.1 ± 157.3 mm2 (p = 0.011). AD improved significantly by 33% from 1.52 ± 0.82 to 2.02 ± 0.93 × 10-3 mmHg-1 (p < 0.001). Increase of AD at follow-up was significantly more pronounced in younger patients (p = 0.005) and responders to RDN (p = 0.002). Patients with high-baseline AD were significantly younger (61.4 ± 10.1 vs. 67.1 ± 8.4 years, p = 0.022). However, there was no significant correlation of baseline AD to response to RDN. AD is improved after RDN across all age groups. Importantly, these improvements appear to be unrelated to observed BP changes, suggesting that RDN may have direct effects on the central vasculature.


Asunto(s)
Aorta Torácica/fisiopatología , Presión Sanguínea/fisiología , Hipertensión/terapia , Riñón/inervación , Simpatectomía/métodos , Rigidez Vascular/fisiología , Monitoreo Ambulatorio de la Presión Arterial , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
13.
BMC Cardiovasc Disord ; 18(1): 47, 2018 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-29506495

RESUMEN

BACKGROUND: Severe obesity is asscociated with an increased risk of coronary artery disease (CAD) but non-invasive cardiac imaging modalities have important technical limits. CASE PRESENTATION: We report a case of a 58-year old patient with suspected CAD and severely elevated BMI of 58 kg/m2. CONCLUSIONS: Stress-CMR was able to non-invasively stratify risk with good imaging quality despite the body dimensions of the patient.


Asunto(s)
Índice de Masa Corporal , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Estenosis Coronaria/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica/métodos , Obesidad Mórbida/complicaciones , Purinas/administración & dosificación , Pirazoles/administración & dosificación , Vasodilatadores/administración & dosificación , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/complicaciones , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Persona de Mediana Edad , Obesidad Mórbida/diagnóstico , Valor Predictivo de las Pruebas , Pronóstico , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...