Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

2.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38460161

RESUMEN

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Asunto(s)
Reestenosis Coronaria , Infarto del Miocardio , Femenino , Humanos , Anciano , Paclitaxel , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Stents , Resultado del Tratamiento , Muerte
3.
Am J Cardiol ; 215: 56-57, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-37866391

RESUMEN

Transcatheter aortic valve implantation (TAVI) is now a well-established modality of treating severe symptomatic aortic valve stenosis in patients deemed at great surgical risk. In patients with coexisting anomalous coronary arteries, however, TAVI presents technical challenges, and coronary obstruction is a feared complication. In this study, we present the case of successful TAVI in a 78-year-old patient with anomalous left main coronary artery originating from the right coronary artery.


Asunto(s)
Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía
4.
Am J Cardiol ; 207: 370-379, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37778226

RESUMEN

The EVOLVE Short DAPT study demonstrated the safety of truncated dual antiplatelet therapy (DAPT) in patients with a high bleeding risk (HBR) treated with SYNERGY stent(s) (Boston Scientific Company, Marlborough, Massachusetts). In this population, bleeding and ischemic risk prediction may further inform DAPT decisions. This post hoc analysis of the EVOLVE Short DAPT study identified predictors of ischemic and bleeding events up to 15 months using Cox proportional hazard models. The predicted probabilities of bleeding were calculated using the Breslow method. Of 2,009 enrolled patients, 96.9% of the patients met at least 1 HBR criteria. At 15 months, the cumulative incidences of bleeding and ischemic events were 6.3% and 6.0%, respectively. The risk of bleeding was increased in patients who received oral anticoagulants (hazard ratio [HR] 2.24, 95% confidence interval [CI] 1.50 to 3.36, p <0.001) or had peripheral vascular disease (HR 1.61, 95% CI 1.01 to 2.56, p = 0.045). The risk of ischemic events was increased in patients with diabetes (HR 1.86, 95% CI 1.24 to 2.78, p <0.01) or congestive heart failure (HR 2.06, 95% CI 1.39 to 3.04, p <0.001). Renal insufficiency/failure was associated with both endpoints. There was a strong positive correlation between the predicted probability of ischemic and bleeding events (R = 0.77, p <0.001). In 617 patients with a predicted bleeding risk <4%, ischemic events predominated, and the ischemic and bleeding rates were higher in patients with a predicted bleeding risk ≥4%. Within an HBR cohort, specific characteristics identify patients at a higher risk for ischemic and separately, bleeding events. Increased bleeding risk is tied to increased ischemic risk. In conclusion, standardized risk models are needed to inform DAPT decisions in patients with a higher risk. Clinical Trial Registration: NCT02605447.


Asunto(s)
Terapia Antiplaquetaria Doble , Hemorragia , Humanos , Quimioterapia Combinada , Terapia Antiplaquetaria Doble/efectos adversos , Terapia Antiplaquetaria Doble/métodos , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Incidencia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Stents , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 102(3): 464-471, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37493431

RESUMEN

BACKGROUND: Ultrathin strut coronary drug-eluting stents (DES) have demonstrated improved safety and efficacy in large contemporary trials. The evaluation of an ultrathin strut DES in a post-market United States (US) patient population was undertaken. OBJECTIVE: The purpose of this post-approval study is to confirm that the clinical performance of an ultrathin strut bioresorbable polymer sirolimus-eluting stent (BP SES) in clinical practice is similar to that observed with BP SES in the BIOFLOW V pivotal trial. METHODS: BIOFLOW VII is a prospective, multicenter, single-arm US post-market approval study to confirm the clinical performance of BP SES in a real-world setting. The primary endpoint of 1-year target lesion failure (TLF) was compared with a performance goal of 6.9% based on an adapted BIOFLOW V trial BP SES TLF rate and TLF rates from other US market-released DES utilizing the Society for Cardiovascular Angiography and Interventions definition for peri-procedural myocardial infarction (MI). Subjects undergoing percutaneous coronary intervention with BP SES were consented within 24 h post-index procedure with planned follow-up through 5 years. RESULTS: Among 556 enrolled patients, clinical demographics included: 34.7% female, 35.6% with diabetes mellitus, and 56.8% with acute coronary syndromes. The average stent length (mean ± standard deviation) was 20.2 ± 11.8 mm, and the mean number of stents per patient was 1.3 ± 0.6. Procedure success was 99.1% (551/556), and device success was 99.9% (689/690). Among 531 subjects included in the primary endpoint analysis, the 1-year rate of TLF rate was 1.7% (9/531), and the primary endpoint was met compared with the performance goal (p < 0.0001, 95% confidence interval: 0.69%, 3.43%). Rates of target vessel MI and clinically driven target lesion revascularization were 1.3% (7/531) and 0.9% (5/531), with no occurrence of cardiac death. Definite stent thrombosis was observed for two cases (0.4%; 2/556) with one acute (≤24 h) and one late (>30 days and ≤1 year) event. CONCLUSION: In a post-approval study, 1-year clinical outcomes with BP SES were consistent with prior trials supporting the safety and effectiveness of ultrathin BP SES.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Femenino , Masculino , Sirolimus/efectos adversos , Everolimus , Polímeros , Implantes Absorbibles , Estudios Prospectivos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Resultado del Tratamiento , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis
6.
Proc (Bayl Univ Med Cent) ; 36(3): 351-353, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37091776

RESUMEN

Background: As the incidence of aortic stenosis is increasing in correlation with the aging population, symptomatic patients commonly require valve replacement procedures. If left untreated, symptomatic aortic stenosis can lead to death in 2 to 3 years. Often, transcatheter aortic valve replacement (TAVR) procedures are performed with the assistance of oxygenation via nasal cannula. However, oxygenation achieved through a nasal continuous positive airway pressure (nCPAP) device could be a more optimized strategy for patients without any sacrifice in efficacy compared to nasal cannula. Methods: A retrospective chart review was conducted on 28 patients at Baylor University Medical Center who presented to the operating room for a TAVR between January and October 2021. Fourteen patients received oxygenation via nasal cannula (control group) and 14 received oxygenation with nCPAP. Information gathered included method of oxygenation, length of stay, episodes of hypoxia (defined as sustained oxygen saturation <92% for at least 1 minute), paravalvular leak, pacemaker placement, and mean atrial valve (AV) gradient before and after the procedure. Results: In the nCPAP group, the average length of stay was 2.79 days vs 2.71 days in the nasal cannula group. In the nCPAP group, no patient required a permanent pacemaker, while the nasal cannula group had a 40% rate of permanent pacemaker placement. The average preprocedure AV gradient was 51.14 in the nCPAP group and 42.57 in the nasal cannula group. The average postprocedure AV gradient was 8.5 in the nCPAP group and 5.36 in the nasal cannula group. Both groups had an intensive care unit admission rate of 0%. The rate of paravalvular leak was 35.7% in the nCPAP group and 28.6% in the nasal cannula group. The nCPAP group had an average of 0 episodes of hypoxia and the nasal cannula group had an average of 0.93 episodes of hypoxia. Conclusion: The findings demonstrate the viability of nCPAP as an effective method of oxygenation during intravenous sedation of TAVR patients when compared to oxygenation achieved via nasal cannula during TAVRs.

7.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36882136

RESUMEN

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Masculino , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
9.
Am J Cardiol ; 191: 110-118, 2023 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-36669380

RESUMEN

Discordance exists between Doppler-derived and left heart catheterization (LHC)-derived mean gradient (MG) in transcatheter aortic valve implantation (TAVI). We compared echocardiographic parameters of prosthetic valve stenosis and LHC-derived MG in new TAVIs. In a retrospective, single-center study, intraoperative transesophageal echocardiogram (TEE)-derived MG, LHC-derived MG, and acceleration time (AT) were obtained before and after TAVI in 362 patients. Discharge MG, AT, and Doppler velocity index (DVI) using transthoracic echocardiogram (TTE) were also obtained. MG ≥10 mm Hg was defined as abnormal. During native valve assessment with pre-TAVI TEE and pre-TAVI LHC, Pearson correlation coefficient revealed a nearly perfect linear relation between both methods' MGs (r = 0.97, p <0.0001). Intraoperatively, after TAVI, Spearman correlation coefficient revealed a weak-to-moderate relation between post-TAVI TEE and LHC MGs (r = 0.33, p <0.0001). Significant differences were observed in categorizations between post-TAVI TEE MG and post-TAVI AT (McNemar test p = 0.0003) and between post-TAVI TEE MG and post-TAVI LHC MG (signed-rank test p <0.0001), with TEE MG more likely to misclassify a patient as abnormal. At discharge, 30% of patients had abnormal TTE MG, whereas 0% and 0.8% of patients had abnormal DVI and AT, respectively. Discharge TTE MG was not associated with death or hospitalization for heart failure at a median follow-up of 862 days. Post-TAVI Doppler-derived MG by intraoperative TEE was higher than LHC, despite being virtually identical before implantation. At discharge, patients were more likely to be classified as abnormal using MG than DVI and AT. Elevated MG at discharge was not associated with death or hospitalization for heart failure.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Constricción Patológica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Ecocardiografía , Ecocardiografía Transesofágica , Catéteres , Resultado del Tratamiento
10.
JAMA Netw Open ; 5(10): e2238792, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36301543

RESUMEN

Importance: Long-term follow-up after transcatheter aortic valve replacement (TAVR) is of interest given that longitudinal data on mortality and durability of transcatheter heart valves are limited. The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) randomized clinical trial compared the mechanically expanded Lotus valve with the self-expanding CoreValve/EvolutR TAVR platforms. Objective: To describe the final 5-year outcomes of the REPRISE III trial. Design, Setting, and Participants: This prespecified secondary analysis assessed the final 5-year clinical, functional, and echocardiographic outcomes of 912 patients from the REPRISE III trial, which was conducted at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015. Patients had high risk for aortic stenosis or severe or symptomatic aortic stenosis. Data were analyzed from September 22, 2014, to May 21, 2021. Intervention: Lotus valve or CoreValve/EvolutR TAVR platforms. Main Outcomes and Measures: Valve Academic Research Consortium-2 end points, hemodynamic measures, functional status, and health status were examined through the 5-year follow-up. Results: A total of 912 patients (mean [SD] age, 82.8 [7.3] years; 463 women [50.8%]) were randomized to either the Lotus valve group (n = 607) or CoreValve/EvolutR group (n = 305), with a baseline Society of Thoracic Surgeons risk score of 6.8%. Clinical follow-up data from the REPRISE III trial were available for 581 patients (95.7%) in the Lotus valve group and 285 patients (93.4%) in the CoreValve/EvolutR group. At 5 years, the cumulative event rate for all-cause mortality was 50.9% in the Lotus valve group vs 52.8% in the CoreValve/EvolutR group (P = .59). Disabling stroke was less frequent with the Lotus valve vs CoreValve/EvolutR (cumulative event rates, 8.3% vs 12.2%; P = .04), whereas the cumulative event rates for overall stroke were similar in both groups (14.1% vs 15.3%; P = .38). Insertion of a new permanent pacemaker (38.9% vs 27.3%; P < .001) and detection of prosthetic aortic valve thrombosis (5.8% vs 1.8%; P = .007) were more common in the Lotus valve group than in the CoreValve/EvolutR group. A smaller proportion of patients who received the Lotus valve experienced valve malpositioning (0% vs 2.6%; P < .001) and required the use of a second valve (1.0% vs 3.8%; P < .001) during the procedure compared with those who received the CoreValve/EvolutR. Compared with the Lotus valve group, the CoreValve/EvolutR group had a significantly lower mean (SD) aortic gradient (7.8 [4.2] mm Hg vs 12.6 [6.7] mm Hg; P < .001) and larger valve areas (1.57 [0.56] cm2 vs 1.42 [0.42] cm2; P = .10). After 5 years, the proportion of patients with moderate or greater paravalvular leak was not significantly higher with the CoreValve/EvolutR than with the Lotus valve (1.9% vs 0%; P = .31); however, the proportion of patients with mild paravalvular leak was higher in the CoreValve/EvolutR group compared with the Lotus valve group (23.1% vs 7.8%; P = .006). Long-term, similar improvements in New York Heart Association class and Kansas City Cardiomyopathy Questionnaire score were observed in both groups. Conclusions and Relevance: The REPRISE III trial found that, at 5 years, the clinical outcomes of the Lotus valve were comparable to those of the CoreValve/EvolutR and that the Lotus valve was safe and effective. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Accidente Cerebrovascular/etiología
11.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36121045

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Implantación de Prótesis , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Ataque Isquémico Transitorio/etiología , Implantación de Prótesis/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
12.
Proc (Bayl Univ Med Cent) ; 35(4): 428-433, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35754575

RESUMEN

As more patients undergo transcatheter aortic valve implantation (TAVI), knowledge of 1-year mortality and associated factors becomes increasingly important. After other cardiac procedures, discharge location has been shown to be associated with 1-year mortality. We examined outcomes of TAVI patients discharged home vs an extended care facility (ECF). All TAVI patients from January 1, 2012, to December 31, 2017, were evaluated. Cox proportional hazard regression models with cubic splines were used to estimate the adjusted effect of discharge to ECF on 1-year mortality. A total of 957 (85.6%) patients discharged home were compared to 160 (14.3%) discharged to ECF. On univariate analysis, patients discharged home were younger and had a lower Society of Thoracic Surgeons Predicted Risk of Mortality, higher albumin, and fewer vascular complications and strokes. Patients discharged to ECF had a higher 30-day mortality (3.8% vs. 0.5%, P = 0.001) and 1-year mortality (25.7% vs. 8.3%, P < 0.001). Cox proportional hazard regression models showed increased risk of 1-year mortality for patients discharged to ECF. In conclusion, patients discharged to ECF had a higher 30-day and 1-year mortality. The strongest predictor of 1-year mortality was discharge to ECF. Society of Thoracic Surgeons Predicted Risk of Mortality score was not a predictor of 1-year mortality.

13.
Cardiovasc Revasc Med ; 41: 76-80, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35045942

RESUMEN

BACKGROUND/PURPOSE: The COBRA Polyzene F™ NanoCoated Coronary Stent System (PzF coated stent) stent demonstrated favorable clinical outcomes at 9 months but late results have not been reported. We sought to assess the late safety and effectiveness of the PzF coated stent for treatment of de novo coronary artery lesions. METHODS: Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a non-randomized, prospective clinical trial and followed for 5 years. The primary endpoint was target vessel failure (TVF, cardiac death, myocardial infarction [MI], or clinically-driven target vessel revascularization [TVR]) at 9 months. Secondary endpoints included major adverse clinical events (MACE, cardiac death, MI, or clinically driven TLR), clinically driven target lesion revascularization (TLR) and definite or probable stent thrombosis during 5-year follow-up. Endpoints at 5 years were analyzed as cumulative incidence accounting for competing risk of death. RESULTS: Of 296 enrolled patients, 290 (98%) were evaluable at 5 years. By 5 years, MACE had occurred in 61 (21.3%), cardiac death in 11 (4.2%), MI in 25 (8.6%), and TLR in 34 (12.0%) subjects. Between follow-up years 1 and 5, a first MACE occurred in 17 (6.2%), including 10 (4.0%) cardiac death, 4 (1.6%) MI, and 7 (2.9%) TLR events. There were no definite or probable stent thromboses. CONCLUSIONS: The PzF coated stent demonstrated continued safety and effectiveness through 5 years with low to very low incident rates of MACE, MI, TLR and stent thrombosis between 1 and 5 years after stent placement.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Muerte , Humanos , Infarto del Miocardio/complicaciones , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Stents/efectos adversos , Trombosis/etiología , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 99(3): 583-592, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34478233

RESUMEN

OBJECTIVES: To compare clinical outcomes in high bleeding risk (HBR) patients with and without complex percutaneous coronary intervention (PCI) treated with Resolute Onyx zotarolimus-eluting stents (ZES) after 1-month dual antiplatelet therapy (DAPT). BACKGROUND: PCI with 1-month DAPT has been demonstrated to be safe in HBR patients treated with Resolute Onyx ZES. Whether these outcomes are consistent in patients with complex lesions is uncertain. METHODS: Among HBR patients who were event-free 1 month after PCI with ZES and treated thereafter with single antiplatelet therapy (SAPT), the clinical outcomes between 1 month and 1 year were compared after complex PCI (3 vessels treated, ≥ 3 lesions treated, total stent length > 60 mm, bifurcation with ≥ 2 stents implanted, atherectomy, or left main, surgical bypass graft or chronic total occlusion PCI) versus noncomplex PCI. Propensity score adjustment was performed to adjust for baseline differences among complex and noncomplex patients. RESULTS: Complex patients (N = 401, 26.6% of total) had a higher prevalence of hyperlipidemia, diabetes mellitus and previous myocardial infarction (MI). Between 1 month and 1 year, rates of MI (7.1% vs. 4.0%, p = 0.02) and cardiac death/MI (9.3% vs. 6.1%, p = 0.04) were higher among complex versus noncomplex patients, although stent thrombosis rates were similar. After adjustment for baseline characteristics, differences in outcomes were no longer significant between groups. CONCLUSIONS: Higher rates of ischemic outcomes in complex PCI patients were largely explained by baseline clinical differences, rather than lesion complexity, among HBR patients treated with 1-month DAPT following PCI with Resolute Onyx ZES.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Terapia Antiplaquetaria Doble/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 99(2): 373-380, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34051049

RESUMEN

OBJECTIVES: The EVOLVE 48 study evaluated the safety and effectiveness of the SYNERGY 48 mm stent for the treatment of long lesions. BACKGROUND: Clinical evidence supporting the use of very long stents during percutaneous coronary intervention (PCI) is limited. The bioabsorbable polymer SYNERGY stent has shown good long-term data in a broad population of patients undergoing PCI. METHODS: Patients with lesion length >34- ≤44 mm and reference vessel diameter (RVD) ≥2.5- ≤ 4.0 mm were enrolled in this prospective, multicenter, single-arm study. The primary endpoint was 12-month target lesion failure (TLF; composite of target lesion revascularization [TLR], target-vessel myocardial infarction [TV-MI], or cardiac death) compared to a prespecified performance goal (PG). RESULTS: A total of 100 patients with mean lesion length of 35.34 ± 7.15 mm (26 patients with lesion length > 40 mm) and mean RVD 2.72 ± 0.44 mm were enrolled. Moderate to severe calcification was present in 30% of the patients and 89% had pre-TIMI flow grade 3. The rates of technical and clinical procedural success were 100%. One-year TLF was observed in 4.1% patients compared to a prespecified PG of 19.5% (95% upper confidence bound = 9.1%; p < 0.0001). Cardiac death and TLR were each observed in one patient, and TV-MI in two patients treated with SYNERGY 48 mm stent. Between the 1-2-year timeframe, TV-MI occurred in one additional patient. None of the patients experienced a definite or probable stent thrombosis through 2 years. CONCLUSIONS: PCI of long coronary lesions with the 48 mm SYNERGY stent demonstrated good procedural and clinical outcomes through 2 years, supporting its clinical safety and efficacy.


Asunto(s)
Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Fármacos Cardiovasculares/efectos adversos , Everolimus/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sirolimus , Stents , Resultado del Tratamiento
16.
Am Heart J ; 241: 101-107, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34314727

RESUMEN

BACKGROUND: Drug-coated balloon (DCB) technology was developed as an alternative treatment for obstructive coronary artery disease (CAD) and in-stent restenosis (ISR). Management of coronary ISR is clinically challenging and frequently encountered in practice. The Agent DCB uses an inactive excipient to effectively deliver a targeted, therapeutic dose of paclitaxel to the vessel wall. STUDY DESIGN: AGENT IDE is a prospective, multicenter, randomized controlled trial to evaluate superiority of the Agent DCB to balloon angioplasty in treating patients with ISR. A total of 480 patients with ISR of a previously treated lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm will be initially randomized. Subjects presenting with recent myocardial infarction (MI), complex lesions, or thrombus in the target vessel will be excluded. An adaptive group sequential design with one formal interim analysis for sample size re-estimation will be conducted, and the sample size may be increased to a maximum of 600 subjects. The primary endpoint is the rate of 12-month target lesion failure (TLF; composite of any ischemia-driven revascularization of the target lesion (TLR), target vessel related MI, or cardiac death) and will be tested for superiority in the test arm against the control. Functional status and general health-related quality of life will be measured by changes in the EQ-5D scores. Subjects will be followed for 5 years following the index procedure. CONCLUSION: This study will prospectively evaluate the safety and efficacy of Agent DCB in patients treated for coronary ISR.


Asunto(s)
Angioplastia Coronaria con Balón , Catéteres Cardíacos/clasificación , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria , Paclitaxel/farmacología , Reoperación , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/métodos , Antineoplásicos Fitogénicos/farmacología , Materiales Biocompatibles Revestidos/farmacología , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Reoperación/efectos adversos , Reoperación/instrumentación , Reoperación/métodos
17.
JACC Cardiovasc Interv ; 14(5): 515-527, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33663779

RESUMEN

OBJECTIVES: The REFLECT II (Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Implantation) trial was designed to investigate the safety and efficacy of the TriGUARD 3 (TG3) cerebral embolic protection in patients undergoing transcatheter aortic valve replacement. BACKGROUND: Cerebral embolization occurs frequently following transcatheter aortic valve replacement and procedure-related ischemic stroke occurs in 2% to 6% of patients at 30 days. Whether cerebral protection with TriGuard 3 is safe and effective in reducing procedure-related cerebral injury is not known. METHODS: This prospective, multicenter, single-blind, 2:1 randomized (TG3 vs. no TG3) study was designed to enroll up to 345 patients. The primary 30-day safety endpoint (Valve Academic Research Consortium-2 defined) was compared with a performance goal (PG). The primary hierarchical composite efficacy endpoint (including death or stroke at 30 days, National Institutes of Health Stroke Scale score worsening in hospital, and cerebral ischemic lesions on diffusion-weighted magnetic resonance imaging at 2 to 5 days) was compared using the Finkelstein-Schoenfeld method. RESULTS: REFLECT II enrolled 220 of the planned 345 patients (63.8%), including 41 roll-in and 179 randomized patients (121 TG3 and 58 control subjects) at 18 US sites. The sponsor closed the study early after the U.S. Food and Drug Administration recommended enrollment suspension for unblinded safety data review. The trial met its primary safety endpoint compared with the PG (15.9% vs. 34.4% (p < 0.0001). The primary hierarchal efficacy endpoint at 30 days was not met (mean scores [higher is better]: -8.58 TG3 vs. 8.08 control; p = 0.857). A post hoc diffusion-weighted magnetic resonance imaging analysis of per-patient total lesion volume above incremental thresholds showed numeric reductions in total lesion volume >500 mm3 (-9.7%) and >1,000 mm3 (-44.5%) in the TG3 group, which were more pronounced among patients with full TG3 coverage: -51.1% (>500 mm3) and -82.9% (>1,000 mm3). CONCLUSIONS: The REFLECT II trial demonstrated that the TG3 was safe compared with a historical PG but did not meet its pre-specified primary superiority efficacy endpoint.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Prospectivos , Factores de Riesgo , Método Simple Ciego , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Proc (Bayl Univ Med Cent) ; 33(4): 520-523, 2020 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-33100519

RESUMEN

Coronary angiography is used to assess the burden of coronary artery disease prior to surgical valve repair/replacement and often leads to concomitant bypass and valve surgery. We sought to evaluate outcomes of an alternative, hybrid approach involving percutaneous coronary intervention (PCI) and valve surgery, assessing the rate of stent thrombosis as a primary outcome. We reviewed charts of consecutive patients who underwent planned PCI prior to surgical valve repair/replacement by a single surgeon from January 2008 to December 2016. We calculated rates of surgical complication, duration of dual antiplatelet therapy (DAPT) prior to surgery, and rates of stent thrombosis and in-stent restenosis. Twenty-four patients were included in this study. Surgery was performed a median of 52.5 days following PCI. DAPT was withheld an average of 8 days before and resumed an average of 4 days after surgery. Ninety-two percent of surgeries were minimally invasive. There were no bleeding complications, stent thromboses, or restenosis events. All patients survived the 1-year follow-up. For patients with mixed coronary and valvular heart disease, a heart team approach involving preoperative PCI followed by staged minimally invasive valvular surgery appears to be safe and warrants further exploration.

20.
Am J Cardiol ; 131: 1-6, 2020 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-32732010

RESUMEN

There is limited information regarding clinical characteristics and outcomes of patients with SARS-CoV-2 (COVID-19) disease presenting with ST-segment elevation myocardial infarction (STEMI). In this multicenter retrospective study, we reviewed charts of patients admitted with symptomatic COVID-19 infection and STEMI to a total of 4 hospitals spanning Italy, Lithuania, Spain and Iraq from February 1, 2020 to April 15, 2020. A total of 78 patients were included in this study, 49 (63%) of whom were men, with a median age of 65 [58, 71] years, and high comorbidity burden. During hospitalization, 8 (10%) developed acute respiratory distress syndrome, and 14 (18%) required mechanical ventilation. 19 (24%) patients were treated with primary Percutaneous Coronary Intervention (PCI) and 59 (76%) were treated with fibrinolytic therapy. 13 (17%) patients required cardiac resuscitation, and 9 (11%) died. For the 19 patients treated with primary PCI, 8 (42%) required intubation and 8 (42%) required cardiac resuscitation; stent thrombosis occurred in 4 patients (21%). A total of 5 patients (26%) died during hospitalization. 50 (85%) of the 59 patients initially treated with fibrinolytic therapy had successful fibrinolysis. The median time to reperfusion was 27 minutes [20, 34]. Hemorrhagic stroke occurred in 5 patients (9%). Six patients (10%) required invasive mechanical ventilation; 5 (9%) required cardiac resuscitation, and 4 (7%) died. In conclusion, this is the largest case series to-date of COVID-19 positive patients presenting with STEMI and spans 4 countries. We found a high rate of stent thrombosis, indicating a possible need to adapt STEMI management for COVID-19 patients.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/complicaciones , Fibrinolíticos/uso terapéutico , Intervención Coronaria Percutánea/métodos , Neumonía Viral/complicaciones , Infarto del Miocardio con Elevación del ST/terapia , Terapia Trombolítica/métodos , Anciano , COVID-19 , Angiografía Coronaria , Infecciones por Coronavirus/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/epidemiología , Estudios Retrospectivos , SARS-CoV-2 , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/diagnóstico , España/epidemiología , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...