Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Orthop Res ; 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824275

RESUMEN

Muscle weakness following anterior cruciate ligament reconstruction (ACLR) increases the risk of posttraumatic osteoarthritis (OA). However, focusing solely on muscle weakness overlooks other aspects like muscle composition, which could hinder strength recovery. Intramuscular fat is a non-contractile element linked to joint degeneration in idiopathic OA, but its role post-ACLR has not been thoroughly investigated. To bridge this gap, we aimed to characterize quadriceps volume and intramuscular fat in participants with ACLR (male/female = 15/9, age = 22.8 ± 3.6 years, body mass index [BMI] = 23.2 ± 1.9, time since surgery = 3.3 ± 0.9 years) and in controls (male/female = 14/10, age = 22.0 ± 3.1 years, BMI = 23.3 ± 2.6) while also exploring the associations between intramuscular fat and muscle volume with isometric strength. Linear mixed effects models assessed (I) muscle volume, (II) intramuscular fat, and (III) strength between limbs (ACLR vs. contralateral vs. control). Regression analyses were run to determine if intramuscular fat or volume were associated with quadriceps strength. The ACLR limb was 8%-11% smaller than the contralateral limb (p < 0.05). No between-limb differences in intramuscular fat were observed (p 0.091-0.997). Muscle volume but not intramuscular fat was associated with strength in the ACLR and control limbs (p < 0.001-0.002). We demonstrate that intramuscular fat does not appear to be an additional source of quadriceps dysfunction following ACLR and that muscle size only explains some of the variance in muscle strength.

2.
J Vis Exp ; (206)2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38682921

RESUMEN

Electromyography (EMG) is a valuable diagnostic tool for detecting neuromuscular abnormalities. Implantable epimysial electrodes are commonly used to measure EMG signals in preclinical models. Although classical resources exist describing the principles of epimysial electrode fabrication, there is a sparsity of illustrative information translating electrode theory to practice. To remedy this, we provide an updated, easy-to-follow guide on fabricating and testing a low-cost epimysial electrode. Electrodes were made by folding and inserting two platinum-iridium foils into a precut silicone base to form the contact surfaces. Next, coated stainless steel wires were welded to each contact surface to form the electrode leads. Lastly, a silicone mixture was used to seal the electrode. Ex vivo testing was conducted to compare our custom-fabricated electrode to an industry standard electrode in a saline bath, where high levels of signal agreement (sine [intraclass correlation - ICC= 0.993], square [ICC = 0.995], triangle [ICC = 0.958]), and temporal-synchrony (sine [r = 0.987], square [r = 0.990], triangle [r= 0.931]) were found across all waveforms. Low levels of electrode impedance were also quantified via electrochemical impedance spectroscopy. An in vivo performance assessment was also conducted where the vastus lateralis muscle of a rat was surgically instrumented with the custom-fabricated electrode and signaling was acquired during uphill and downhill walking. As expected, peak EMG activity was significantly lower during downhill walking (0.008 ± 0.005 mV) than uphill (0.031 ± 0.180 mV, p = 0.005), supporting the validity of the device. The reliability and biocompatibility of the device were also supported by consistent signaling during level walking at 14 days and 56 days post implantation (0.01 ± 0.007 mV, 0.012 ± 0.007 mV respectively; p > 0.05) and the absence of histological inflammation. Collectively, we provide an updated workflow for the fabrication and testing of low-cost epimysial electrodes.


Asunto(s)
Electrodos Implantados , Electromiografía , Electromiografía/métodos , Electromiografía/instrumentación , Animales , Ratas , Flujo de Trabajo , Músculo Esquelético/fisiología , Diseño de Equipo , Electrodos
3.
Exerc Sport Sci Rev ; 51(3): 109-116, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37093645

RESUMEN

Lengthening contractions (i.e., eccentric contractions) are capable of uniquely triggering the nervous system and signaling pathways to promote tissue health/growth. This mode of exercise may be particularly potent for patients suffering from muscle weakness after joint injury. Here we provide a novel framework for eccentric exercise as a safe, effective mode of exercise prescription for muscle recovery.


Asunto(s)
Ejercicio Físico , Contracción Muscular , Humanos , Ejercicio Físico/fisiología , Contracción Muscular/fisiología , Debilidad Muscular , Terapia por Ejercicio , Transducción de Señal , Músculo Esquelético/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...