Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Cardiovasc Med ; 10: 1135848, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37139123

RESUMEN

Introduction: Vaccine-induced myocarditis is a rare complication of messenger RNA (mRNA) COVID-19 vaccines. Case presentation: We report a case of acute myopericarditis in a recipient of allogeneic hematopoietic cells following the first dose of the mRNA-1273 vaccine and the successful administration of a second and third dose while on prophylactic treatment with colchicine to successfully complete the vaccination. Conclusion: Treatment and prevention of mRNA-vaccine-induced myopericarditis represent a clinical challenge. The use of colchicine is feasible and safe to potentially reduce the risk of this rare but severe complication and allows re-exposure to an mRNA vaccine.

2.
Case Rep Cardiol ; 2021: 6651361, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33728072

RESUMEN

In March 2020, a 64-year-old female with mitral valve insufficiency and persistent atrial fibrillation underwent preoperative noninvasive mapping for developing an ablation strategy. In the computed tomography (CT) scan, typical signs of COVID-19 were described. Since the consecutive polymerase chain reaction (PCR) test was negative, the severely symptomatic patient was planned for urgent surgery. Noninvasive mapping showed that atrial fibrillation was maintained by left atrial structures and pulmonary veins only. On admission day, the preoperative routine COVID-19 PCR test was positive, and after recovery, uneventful mitral valve repair with cryoablation of the left atrium and pulmonary veins was performed. Our case describes the potential benefit of preoperative noninvasive mapping for the development of a surgical ablation strategy, as well as the challenges in managing urgent surgical patients during the COVID-19 pandemic and the corresponding diagnostic relevance of CT.

4.
Eur Radiol ; 27(12): 5252-5259, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28374080

RESUMEN

OBJECTIVES: To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages. METHODS: A phantom with 45 hypoattenuating lesions was placed in two water containers and scanned at 70, 80, 100, and 120 kVp. The 120-kVp protocol served as reference, and the volume CT dose index (CTDIvol) was kept constant for all protocols. The datasets were reconstructed with MBIR and FBP. Image noise and contrast-to-noise-ratio (CNR) were assessed. Low-contrast lesion detectability was evaluated by 12 radiologists. RESULTS: MBIR decreased the image noise by 24% and 27%, and increased the CNR by 30% and 29% for the medium and large phantoms, respectively. Lower tube voltages increased the CNR by 58%, 46%, and 16% at 70, 80, and 100 kVp, respectively, compared with 120 kVp in the medium phantom and by 9%, 18% and 12% in the large phantom. No significant difference in lesion detection rate was observed (medium: 79-82%; large: 57-65%; P > 0.37). CONCLUSIONS: Although MBIR improved quantitative image quality compared with FBP, it did not result in increased low-contrast lesion detection in abdominal CT at different tube voltages in simulated medium and large patients. KEY POINTS: • MBIR improved quantitative image quality but not lesion detection compared with FBP. • Increased CNR by low tube voltages did not improve lesion detection. • Changes in image noise and CNR do not directly influence diagnostic accuracy.


Asunto(s)
Algoritmos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/normas , Humanos , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...