1.
Heart Rhythm ; 9(10): 1585-91, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22561598

RESUMEN

BACKGROUND: Inappropriate therapies are frequently delivered by implantable cardioverter-defibrillators (ICDs). We have investigated muscle perfusion as a means of augmenting arrhythmia discrimination by using implanted near-infrared spectroscopy. OBJECTIVE: To evaluate hemodynamic stability by monitoring muscle perfusion from within the ICD pocket, in fresh tissue and inside the scar capsule on preexisting ICD generators, during induced cardiac arrhythmias, in humans. METHODS: The sensor was implanted on or under the pectoral muscle, during ICD defibrillation threshold testing. A microvascular oxygenation trend indicator (O2 Index) was computed during 74 induced ventricular fibrillation and 34 normal sinus rhythm episodes in 34 patients and also during 28 atrial and 90 ventricular overdrive pacing episodes as simulations of supraventricular and ventricular tachycardias, respectively. RESULTS: On average, the change in oxygenation, based on the O2 Index, was statistically significant (P <.003) from baseline within 3 seconds following cardiac arrest. An optimized O2 Index, used for detecting the hemodynamic trend, exhibited a decreasing trend during ventricular fibrillation (P <.0001) and was different from that during normal sinus rhythm (P <.0001). The sensitivity for the detection of ventricular fibrillation was 100%, and the specificity for the rejection of normal sinus rhythm was 82% in the presence of scar tissue on the optical sensor. For a 35-mm Hg drop in the mean arterial pressure as the threshold for hemodynamic instability, the specificity for the rejection of hemodynamically stable atrial and ventricular pacing episodes was 93% and 71%, respectively. CONCLUSION: An implantable near-infrared spectroscopic sensor may be useful for hemodynamic monitoring during cardiac arrhythmias to prevent inappropriate therapy.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantables , Hemoglobinas/química , Músculo Esquelético/irrigación sanguínea , Espectroscopía Infrarroja Corta/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
2.
Pacing Clin Electrophysiol ; 24(6): 1026-8, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11449579

RESUMEN

This is a case of a right coronary artery occlusion complicating a RF catheter ablation of a posteroseptal accessory connection in an 8-year-old boy. After multiple balloon angioplasty attempts in the occluded vessel, only transient patency was achieved. The occlusion was successfully treated with placement of an intracoronary stent.


Asunto(s)
Ablación por Catéter/efectos adversos , Enfermedad Coronaria/etiología , Enfermedad Coronaria/cirugía , Stents , Niño , Humanos , Masculino , Inducción de Remisión