Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biointerphases ; 16(1): 011004, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33706519

RESUMEN

X-ray fluorescence analysis enables the study of trace element distributions in biological specimens. When this analysis is done under cryogenic conditions, cells are cryofixed as closely as possible to their natural physiological state, and the corresponding intracellular elemental densities can be analyzed. Details about the experimental setup used for analysis at the P06 beamline at Petra III, DESY and the used cryo-transfer system are described in this work. The system was applied to analyze the elemental distribution in single HeLa cells, a cell line frequently used in a wide range of biological applications. Cells adhered to silicon nitride substrates were cryoprotected within an amorphous ice matrix. Using a continuous scanning scheme and a KB x-ray focus, the distribution of elements in the cells was studied. We were able to image the intracellular potassium and zinc levels in HeLa cells as two key elements relevant for the physiology of cells.


Asunto(s)
Congelación , Espectrometría por Rayos X , Oligoelementos/análisis , Agua/química , Células HeLa , Humanos , Vacio , Rayos X
2.
J Synchrotron Radiat ; 27(Pt 3): 625-632, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32381762

RESUMEN

The unique diagnostic possibilities of X-ray diffraction, small X-ray scattering and phase-contrast imaging techniques applied with high-intensity coherent X-ray synchrotron and X-ray free-electron laser radiation can only be fully realized if a sufficient dynamic range and/or spatial resolution of the detector is available. In this work, it is demonstrated that the use of lithium fluoride (LiF) as a photoluminescence (PL) imaging detector allows measuring of an X-ray diffraction image with a dynamic range of ∼107 within the sub-micrometre spatial resolution. At the PETRA III facility, the diffraction pattern created behind a circular aperture with a diameter of 5 µm irradiated by a beam with a photon energy of 500 eV was recorded on a LiF crystal. In the diffraction pattern, the accumulated dose was varied from 1.7 × 105 J cm-3 in the central maximum to 2 × 10-2 J cm-3 in the 16th maximum of diffraction fringes. The period of the last fringe was measured with 0.8 µm width. The PL response of the LiF crystal being used as a detector on the irradiation dose of 500 eV photons was evaluated. For the particular model of laser-scanning confocal microscope Carl Zeiss LSM700, used for the readout of the PL signal, the calibration dependencies on the intensity of photopumping (excitation) radiation (λ = 488 nm) and the gain have been obtained.

3.
Sci Rep ; 8(1): 8413, 2018 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-29849036

RESUMEN

Insects represent the majority of known animal species and exploit a variety of fascinating nanotechnological concepts. We investigated the wings of the damselfly Calopteryx haemorrhoidalis, whose males have dark pigmented wings and females have slightly pigmented wings. We used scanning electron microscopy (SEM) and nanoscale synchrotron X-ray fluorescence (XRF) microscopy analysis for characterizing the nanostructure and the elemental distribution of the wings, respectively. The spatially resolved distribution of the organic constituents was examined by synchrotron Fourier transform infrared (s-FTIR) microspectroscopy and subsequently analyzed using hierarchical cluster analysis. The chemical distribution across the wing was rather uniform with no evidence of melanin in female wings, but with a high content of melanin in male wings. Our data revealed a fiber-like structure of the hairs and confirmed the presence of voids close to its base connecting the hairs to the damselfly wings. Within these voids, all detected elements were found to be locally depleted. Structure and elemental contents varied between wing membranes, hairs and veins. The elemental distribution across the membrane was rather uniform, with higher Ca, Cu and Zn levels in the male damselfly wing membranes.


Asunto(s)
Odonata/anatomía & histología , Espectrometría por Rayos X/instrumentación , Espectroscopía Infrarroja por Transformada de Fourier/instrumentación , Sincrotrones , Alas de Animales/química , Animales , Femenino , Masculino
4.
Opt Express ; 26(2): 1237-1254, 2018 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-29402000

RESUMEN

Coherent X-ray ptychography is a tool for highly dose efficient lensless nano-imaging of biological samples. We have used partially coherent soft X-ray synchrotron radiation to obtain a quantitative image of a laterally extended, dried, and unstained fibroblast cell by ptychography. We used data with and without a beam stop that allowed us to measure coherent diffraction with a high-dynamic range of 1.7·106. As a quantitative result, we obtained the refractive index values for two regions of the cell with respect to a reference area. Due to the photon energy in the water window we obtained an extremely high contrast of 53% at 71 nm half-period resolution. The dose applied in our experiment was 9.5·104 Gy and is well below the radiation damage threshold. The concept for dynamic range improvement for low dynamic range detectors with a beam stop opens the path for high resolution nano-imaging of a variety of samples including cryo-preserved, hydrated and unstained biological cells.


Asunto(s)
Algoritmos , Fibroblastos , Microscopía/métodos , Intensificación de Imagen Radiográfica/métodos , Difracción de Rayos X , Fotones , Dosis de Radiación
5.
J Phys Condens Matter ; 27(23): 235103, 2015 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-25992483

RESUMEN

A study of lysozyme adsorption below a behenic acid membrane and at the solid-liquid interface between aqueous lysozyme solution and a silicon wafer in the presence of sodium chloride is presented. The salt concentration was varied between 1 mmol L(-1) and 1000 mmol L(-1). X-ray reflectivity data show a clear dependence of the protein adsorption on the salt concentration. Increasing salt concentrations result in a decreased protein adsorption at the interface until a complete suppression at high concentrations is reached. This effect can be attributed to a reduced attractive electrostatic interaction between the positively charged proteins and negatively charged surfaces by charge screening. The measurements at the solid-liquid interfaces show a transition from unoriented order of lysozyme in the adsorbed film to an oriented order with the short protein axis perpendicular to the solid-liquid interface with rising salt concentration.


Asunto(s)
Muramidasa/química , Cloruro de Sodio/farmacología , Adsorción/efectos de los fármacos , Animales , Relación Dosis-Respuesta a Droga , Ácidos Grasos/química , Membranas Artificiales , Propiedades de Superficie
6.
Appl Nurs Res ; 26(4): 218-24, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24238084

RESUMEN

Colorectal cancer (CRC) is one of the leading cancer killers in the U.S. despite the vast array of screening and detection methods available. The U.S. Hispanic population, in particular, reflects low rates of CRC screening. In order to get a comprehensive understanding of barriers to CRC screening in this population, an integrative review was performed in PubMed and CINAHL from 2002 to 2012; eight studies on various barriers to CRC screening among the U.S. Hispanic population were examined. Our findings recognized fear, cost, and lack of awareness as common barriers to CRC screening and more specific barriers applicable to the Hispanic population being low literacy/educational levels and lack of provider recommendations. Analysis indicated culturally-specific barriers to CRC screening among Hispanics, the largest being limited English proficiency. The review demonstrated a need for additional targeted approaches, awareness education, and provider training as ways to increase CRC screening in Hispanics.


Asunto(s)
Neoplasias Colorrectales/diagnóstico , Hispánicos o Latinos , Humanos , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...