Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Cytotherapy ; 24(7): 691-698, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35279374

RESUMEN

BACKGROUND AIMS: The final harvest or wash of a cell therapy product is an important step in manufacturing, as viable cell recovery is critical to the overall success of a cell therapy. Most harvest/wash approaches in the clinical lab involve centrifugation, which can lead to loss of cells and decreased viability of the final product. Here the authors report on a multi-center assessment of the LOVO Cell Processing System (Fresenius Kabi, Bad Homburg, Germany), a cell processing device that uses a spinning filtration membrane instead of centrifugation. METHODS: Four National Institutes of Health Production Assistance for Cellular Therapies cell processing facilities (CPFs) assessed the LOVO Cell Processing System for final harvest and/or wash of the following three different cell products: activated T cells (ATCs), tumor-infiltrating lymphocytes (TILs) and bone marrow-derived mesenchymal stromal cells (MSCs). Each site compared their current in-house, routinely used method of final cell harvest and/or wash with that of the LOVO device. RESULTS: Final harvest and/or wash of ATCs, TILs and MSCs using the LOVO system resulted in satisfactory cell viability and recovery with some substantial improvement over the in-house methods of CPFs. Processing time was variable among cell types/facilities. CONCLUSIONS: The LOVO Cell Processing System provides an alternative to centrifuge-based technologies. The system employs a spinning membrane filter, exposing cells to minimal g-forces compared with centrifugation, and is automated and closed. This small multi-center study demonstrated the ability of the LOVO device to yield satisfactory cell viability and recovery of T cells and MSCs.


Asunto(s)
Tratamiento Basado en Trasplante de Células y Tejidos , Células Madre Mesenquimatosas , Centrifugación
2.
Nat Med ; 27(9): 1636-1645, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34518679

RESUMEN

The radiation-attenuated Plasmodium falciparum sporozoite (PfSPZ) vaccine provides protection against P. falciparum infection in malaria-naïve adults. Preclinical studies show that T cell-mediated immunity is required for protection and is readily induced in humans after vaccination. However, previous malaria exposure can limit immune responses and vaccine efficacy (VE) in adults. We hypothesized that infants with less previous exposure to malaria would have improved immunity and protection. We conducted a multi-arm, randomized, double-blind, placebo-controlled trial in 336 infants aged 5-12 months to determine the safety, tolerability, immunogenicity and efficacy of the PfSPZ Vaccine in infants in a high-transmission malaria setting in western Kenya ( NCT02687373 ). Groups of 84 infants each received 4.5 × 105, 9.0 × 105 or 1.8 × 106 PfSPZ Vaccine or saline three times at 8-week intervals. The vaccine was well tolerated; 52 (20.6%) children in the vaccine groups and 20 (23.8%) in the placebo group experienced related solicited adverse events (AEs) within 28 d postvaccination and most were mild. There was 1 grade 3-related solicited AE in the vaccine group (0.4%) and 2 in the placebo group (2.4%). Seizures were more common in the highest-dose group (14.3%) compared to 6.0% of controls, with most being attributed to malaria. There was no significant protection against P. falciparum infection in any dose group at 6 months (VE in the 9.0 × 105 dose group = -6.5%, P = 0.598, the primary statistical end point of the study). VE against clinical malaria 3 months after the last dose in the highest-dose group was 45.8% (P = 0.027), an exploratory end point. There was a dose-dependent increase in antibody responses that correlated with VE at 6 months in the lowest- and highest-dose groups. T cell responses were undetectable across all dose groups. Detection of Vδ2+Vγ9+ T cells, which have been correlated with induction of PfSPZ Vaccine T cell immunity and protection in adults, were infrequent. These data suggest that PfSPZ Vaccine-induced T cell immunity is age-dependent and may be influenced by Vδ2+Vγ9+ T cell frequency. Since there was no significant VE at 6 months in these infants, these vaccine regimens will likely not be pursued further in this age group.


Asunto(s)
Vacunas contra la Malaria/administración & dosificación , Malaria Falciparum/tratamiento farmacológico , Plasmodium falciparum/efectos de los fármacos , Vacunas Atenuadas/administración & dosificación , Adulto , Formación de Anticuerpos/efectos de los fármacos , Formación de Anticuerpos/inmunología , Linfocitos B/efectos de los fármacos , Linfocitos B/inmunología , Método Doble Ciego , Humanos , Lactante , Kenia/epidemiología , Vacunas contra la Malaria/efectos adversos , Malaria Falciparum/inmunología , Malaria Falciparum/parasitología , Malaria Falciparum/prevención & control , Plasmodium falciparum/patogenicidad , Esporozoítos/efectos de los fármacos , Esporozoítos/patogenicidad , Linfocitos T/efectos de los fármacos , Vacunación , Vacunas Atenuadas/efectos adversos
3.
Lancet Infect Dis ; 21(5): 668-676, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33242473

RESUMEN

BACKGROUND: Timely detection and treatment are important for the control of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis. The objective of this study was to measure the performance of the Visby Medical Sexual Health Test, a single-use, point-of-care PCR device. METHODS: Women aged 14 years and older who presented consecutively to ten clinical sites across seven US states were enrolled for a cross-sectional, single-visit study. Patients who consented to participate, and who had not used any exclusionary products in the genital area in the previous 48 h, provided self-collected vaginal swabs for testing with the investigational device. Untrained operators received the specimens and ran the device using the guide provided. Specimens had to be run within 2 h of collection to be considered valid. For comparison, patient-infected status was derived by testing clinician-collected vaginal specimens with the Hologic Aptima Combo 2 Assay and Aptima Trichomonas vaginalis Assay, as well as the BD ProbeTec CT/GC Qx Amplified DNA Assay and BD ProbeTec Trichomonas vaginalis Qx Assay. If the results of those assays did not match, the BD MAX CT/GC/TV was used as a tiebreaker. The primary outcomes were the sensitivity and specificity of the investigational device for the detection of C trachomatis, N gonorrhoeae, and T vaginalis compared with patient-infected status. FINDINGS: Between Feb 25, 2019, and Jan 6, 2020, 1585 participants aged between 14 years and 80 years (mean 34·8 [SD 14·2]) were enrolled. 1555 participants had tests run with the investigational device, of whom 1532 (98·5%) had a valid result on either the first or repeat test. Among the patients with evaluable results (including a determinate patient-infected status), the device had a sensitivity of 97·6% (95% CI 93·2-99·2) and specificity of 98·3% (97·5-98·9) for C trachomatis (n=1457), sensitivity of 97·4% (86·5-99·5) and specificity of 99·4% (98·9-99·7) for N gonorrhoeae (n=1468), and sensitivity of 99·2% (95·5-99·9) and specificity of 96·9% (95·8-97·7) for T vaginalis (n=1449). INTERPRETATION: This innovative, rapid, easy-to-use, single-use, point-of-care device to detect C trachomatis, N gonorrhoeae, and T vaginalis infections showed excellent sensitivity and specificity, and could represent an important advance in the development of rapid diagnostics for sexually transmitted infections and other infectious diseases. FUNDING: Division of Microbiology and Infectious Diseases, National Institute of Allergy and Infectious Diseases.


Asunto(s)
Chlamydia trachomatis/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Neisseria gonorrhoeae/aislamiento & purificación , Sistemas de Atención de Punto , Reacción en Cadena de la Polimerasa/métodos , Trichomonas vaginalis/aislamiento & purificación , Vagina/microbiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Infecciones por Chlamydia/diagnóstico , Chlamydia trachomatis/genética , Estudios Transversales , Pruebas Diagnósticas de Rutina/métodos , Femenino , Gonorrea/diagnóstico , Humanos , Persona de Mediana Edad , Neisseria gonorrhoeae/genética , Sensibilidad y Especificidad , Salud Sexual , Enfermedades de Transmisión Sexual , Vaginitis por Trichomonas/diagnóstico , Trichomonas vaginalis/genética , Adulto Joven
4.
Clin Infect Dis ; 71(4): 1063-1071, 2020 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-31555824

RESUMEN

BACKGROUND: The whole Plasmodium falciparum sporozoite (PfSPZ) vaccine is being evaluated for malaria prevention. The vaccine is administered intravenously for maximal efficacy. Direct venous inoculation (DVI) with PfSPZ vaccine has been safe, tolerable, and feasible in adults, but safety data for children and infants are limited. METHODS: We conducted an age de-escalation, dose-escalation randomized controlled trial in Siaya County, western Kenya. Children and infants (aged 5-9 years, 13-59 months, and 5-12 months) were enrolled into 13 age-dose cohorts of 12 participants and randomized 2:1 to vaccine or normal saline placebo in escalating doses: 1.35 × 105, 2.7 × 105, 4.5 × 105, 9.0 × 105, and 1.8 × 106 PfSPZ, with the 2 highest doses given twice, 8 weeks apart. Solicited adverse events (AEs) were monitored for 8 days after vaccination, unsolicited AEs for 29 days, and serious AEs throughout the study. Blood taken prevaccination and 1 week postvaccination was tested for immunoglobulin G antibodies to P. falciparum circumsporozoite protein (PfCSP) using enzyme-linked immunosorbent assay. RESULTS: Rates of AEs were similar in vaccinees and controls for solicited (35.7% vs 41.5%) and unsolicited (83.9% vs 92.5%) AEs, respectively. No related grade 3 AEs, serious AEs, or grade 3 laboratory abnormalities occurred. Most (79.0%) vaccinations were administered by a single DVI. Among those in the 9.0 × 105 and 1.8 × 106 PfSPZ groups, 36 of 45 (80.0%) vaccinees and 4 of 21 (19.0%) placebo controls developed antibodies to PfCSP (P < .001). CONCLUSIONS: PfSPZ vaccine in doses as high as 1.8 × 106 can be administered to infants and children by DVI, and was safe, well tolerated, and immunogenic. CLINICAL TRIALS REGISTRATION: NCT02687373.


Asunto(s)
Vacunas contra la Malaria , Malaria Falciparum , Adulto , Animales , Niño , Preescolar , Método Doble Ciego , Humanos , Inmunogenicidad Vacunal , Lactante , Kenia , Vacunas contra la Malaria/efectos adversos , Malaria Falciparum/prevención & control , Plasmodium falciparum , Esporozoítos , Vacunación
5.
Clin Infect Dis ; 71(11): 2849-2857, 2020 12 31.
Artículo en Inglés | MEDLINE | ID: mdl-31782768

RESUMEN

BACKGROUND: A vaccine would be an ideal tool for reducing malaria's impact. PfSPZ Vaccine (radiation attenuated, aseptic, purified, cryopreserved Plasmodium falciparum [Pf] sporozoites [SPZ]) has been well tolerated and safe in >1526 malaria-naive and experienced 6-month to 65-year-olds in the United States, Europe, and Africa. When vaccine efficacy (VE) of 5 doses of 2.7 × 105 PfSPZ of PfSPZ Vaccine was assessed in adults against controlled human malaria infection (CHMI) in the United States and Tanzania and intense field transmission of heterogeneous Pf in Mali, Tanzanians had the lowest VE (20%). METHODS: To increase VE in Tanzania, we increased PfSPZ/dose (9 × 105 or 1.8 × 106) and decreased numbers of doses to 3 at 8-week intervals in a double blind, placebo-controlled trial. RESULTS: All 22 CHMIs in controls resulted in parasitemia by quantitative polymerase chain reaction. For the 9 × 105 PfSPZ group, VE was 100% (5/5) at 3 or 11 weeks (P < .000l, Barnard test, 2-tailed). For 1.8 × 106 PfSPZ, VE was 33% (2/6) at 7.5 weeks (P = .028). VE of dosage groups (100% vs 33%) was significantly different (P = .022). Volunteers underwent repeat CHMI at 37-40 weeks after last dose. 6/6 and 5/6 volunteers developed parasitemia, but time to first parasitemia was significantly longer than controls in the 9 × 105 PfSPZ group (10.89 vs 7.80 days) (P = .039), indicating a significant reduction in parasites in the liver. Antibody and T-cell responses were higher in the 1.8 × 106 PfSPZ group. CONCLUSIONS: In Tanzania, increasing the dose from 2.7 × 105 to 9 × 105 PfSPZ increased VE from 20% to 100%, but increasing to 1.8 × 106 PfSPZ significantly reduced VE. CLINICAL TRIALS REGISTRATION: NCT02613520.


Asunto(s)
Vacunas contra la Malaria , Malaria Falciparum , Malaria , Adulto , Animales , Europa (Continente) , Humanos , Malaria/prevención & control , Malaria Falciparum/prevención & control , Malí , Plasmodium falciparum , Esporozoítos , Tanzanía
6.
Am J Trop Med Hyg ; 100(6): 1433-1444, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30994090

RESUMEN

In 2016, there were more cases and deaths caused by malaria globally than in 2015. An effective vaccine would be an ideal additional tool for reducing malaria's impact. Sanaria® PfSPZ Vaccine, composed of radiation-attenuated, aseptic, purified, cryopreserved Plasmodium falciparum (Pf) sporozoites (SPZ) has been well tolerated and safe in malaria-naïve and experienced adults in the United States and Mali and protective against controlled human malaria infection with Pf in the United States and field transmission of Pf in Mali, but had not been assessed in younger age groups. We, therefore, evaluated PfSPZ Vaccine in 93 Tanzanians aged 45 years to 6 months in a randomized, double-blind, normal saline placebo-controlled trial. There were no significant differences in adverse events between vaccinees and controls or between dosage regimens. Because all age groups received three doses of 9.0 × 105 PfSPZ of PfSPZ Vaccine, immune responses were compared at this dosage. Median antibody responses against Pf circumsporozoite protein and PfSPZ were highest in infants and lowest in adults. T-cell responses were highest in 6-10-year olds after one dose and 1-5-year olds after three doses; infants had no significant positive T-cell responses. The safety data were used to support initiation of trials in > 300 infants in Kenya and Equatorial Guinea. Because PfSPZ Vaccine-induced protection is thought to be mediated by T cells, the T-cell data suggest PfSPZ Vaccine may be more protective in children than in adults, whereas infants may not be immunologically mature enough to respond to the PfSPZ Vaccine immunization regimen assessed.


Asunto(s)
Anticuerpos Antiprotozoarios/sangre , Vacunas contra la Malaria/inmunología , Malaria Falciparum/prevención & control , Plasmodium falciparum/inmunología , Linfocitos T/fisiología , Adolescente , Adulto , Formación de Anticuerpos , Niño , Preescolar , Método Doble Ciego , Femenino , Humanos , Lactante , Vacunas contra la Malaria/efectos adversos , Masculino , Persona de Mediana Edad , Tanzanía , Vacunas Atenuadas
8.
Am J Drug Alcohol Abuse ; 37(5): 440-5, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21854288

RESUMEN

BACKGROUND: Reporting all adverse events (AEs) and serious adverse events (SAEs) in substance use disorder (SUD) clinical trials has yielded limited relevant safety information and has been burdensome to research sites. OBJECTIVE: This article describes a new strategy utilizing standard data elements for AE and SAEs that defines a threshold to reduce unnecessary safety reporting burden in SUD clinical trials and describes retrospective review and prospective preliminary data on the strategy's safety reporting impact. METHODS: We developed a new strategy to standardize safety reporting and tailor reporting to the trial intervention risk. Protocols and safety data from 17 SUD clinical trials were reviewed. Retrospective analysis of five of these studies and prospective application to new studies is described. RESULTS: Across the 17 previously completed trials, a total of 11,220 AEs and 1330 SAEs were reported in the 6737 participants. Wide variability in AE and SAE reporting rates were noted based on trial type and inconsistent reporting strategies. Application of the new, tailored safety strategy retrospectively and prospectively reduces reporting burden of irrelevant safety events. CONCLUSION: Comparison of the previous reporting strategies used in SUD trials to the new strategy demonstrates a more consistent safety system with a reduction in safety reporting burden while maintaining appropriate safety monitoring. SCIENTIFIC SIGNIFICANCE: Safety assessments should be tailored to the participant risks based on the trial intervention. The current strategies could be applied to safety assessments across all clinical trials in SUDs.


Asunto(s)
Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos , Proyectos de Investigación , Trastornos Relacionados con Sustancias/tratamiento farmacológico , Humanos , National Institute on Drug Abuse (U.S.) , Estudios Prospectivos , Estudios Retrospectivos , Riesgo , Trastornos Relacionados con Sustancias/rehabilitación , Estados Unidos
9.
Cytotherapy ; 13(2): 201-13, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20795760

RESUMEN

BACKGROUND AIMS: Shipment of therapeutic somatic cells between a current good manufacturing practice (cGMP) facility and a clinic or between different cGMP facilities requires validated standard operating procedures (SOP). Under National Heart Lung & Blood Institute (NHLBI) sponsorship, the Production Assistance for Cellular Therapies (PACT) group conducted a validation study for the shipping SOP it has created, including shipments of cryopreserved somatic cells, fresh peripheral blood specimens and apheresis products. METHODS: Comparisons of pre- and post-shipped cells and cell products at the three participating facilities included measurements of viability, phenotypic profiles and cellular functions. The data were analyzed at the University of Pittsburgh Biostatistics Facility. RESULTS: No consistent shipping effects on cell viability, phenotype or functions were detected for cryopreserved and shipped peripheral blood mononuclear cells (PBMC), monocytes, immature dendritic cells (iDC), NK-92 or cytotoxic T cells (CTL). Cryopreserved mesenchymal stromal cells (MSC) had a significantly decreased viability after shipment, but this effect was in part because of inter-laboratory variability in the viable cell counts. Shipments of fresh peripheral blood and apheresis products for the generation of CTL and dendritic cells (DC), respectively, had no significant effects on cell product quality. MSC were successfully generated from fresh bone marrow samples shipped overnight. CONCLUSIONS: This validation study provides a useful set of data for guiding shipments of therapeutic somatic cells in multi-institutional clinical trials.


Asunto(s)
Productos Biológicos , Supervivencia Celular , Criopreservación , Recolección de Muestras de Sangre , Comercio , Instituciones de Salud , Humanos , Control de Calidad
10.
Cytotherapy ; 12(2): 170-7, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20078385

RESUMEN

BACKGROUND AIMS: This study was initiated to determine whether CD34(+) cell selection of small-volume bone marrow (BM) samples could be performed effectively on the Isolex(R) 300i Magnetic Cell Selection System device and whether the results obtained from these samples were comparable with results from large standard-volume samples. The impact on CD34(+) recovery using a full versus half vial of Isolex(R) CD34 reagent and the effects of shipping a post-selection product were evaluated. METHODS: A protocol to evaluate CD34(+) cell selection with two ranges of smaller volume BM samples (c. 50 mL and c. 100 mL) was developed and instituted at three Production Assistance for Cellular Therapies (PACT) facilities. The study was performed in two phases. RESULTS: In phase I, the mean post-selection CD34(+) recoveries from the two sizes of samples were 104.1% and 103.3% (smallest and largest volumes, respectively), and mean CD34(+) recoveries were 115.6% and 88.7%, with full and half vials of reagent, respectively. Mean CD34(+) recoveries for post-shipment smaller volume samples were 106.8% and for larger volume samples 116.4%; mean CD34(+) recoveries were 99.9% and 127.4% for post-shipment samples processed with full and half vials of reagent, respectively. In phase II, mean CD34(+) recovery was 76.8% for post-selection samples and 74.0% for post-shipment samples. CONCLUSIONS: The results suggest that smaller volume BM sample processing on the Isolex(R) system is as efficient or more efficient compared with standard-volume sample processing. Post-processing mean CD34(+) recovery results obtained using a full or half vial of CD34 reagent were not significantly different.


Asunto(s)
Antígenos CD34/metabolismo , Células de la Médula Ósea/citología , Separación Celular/métodos , Tratamiento Basado en Trasplante de Células y Tejidos/métodos , Medicina Regenerativa/métodos , Humanos , Control de Calidad , Tamaño de la Muestra
11.
Ann Clin Microbiol Antimicrob ; 5: 2, 2006 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-16469106

RESUMEN

BACKGROUND: The virulence, antimicrobial resistance, and prevalence of S. aureus underscores the need for up-to-date and extensive insights regarding antimicrobial susceptibility trends. One approach to meet this need is analysis of clinical laboratory-based surveillance data. METHODS: Data from The Surveillance Network-USA (TSN), an electronic surveillance network that collects microbiology data from 300 clinical microbiology laboratories across the United States, were used as the source for analysis that included prevalence of S. aureus in clinical specimens, MRSA and multi-drug resistance phenotype rates and trends according to patient location, geographic distributions, and specimen source. RESULTS: S. aureus was the most prevalent species isolated from inpatient specimens (18.7% of all bacterial isolates) and the second most prevalent (14.7%) from outpatient specimens. In March 2005 MRSA rates were 59.2%, 55%, and 47.9% for strains from non-ICU inpatients, ICU, and outpatients, respectively. This trend was noted in all nine US Bureau of Census regions and multi-drug resistance phenotypes (resistance to > or = 3 non-beta-lactams) was common among both inpatient MRSA (59.9%) and outpatient MRSA (40.8%). Greater than 90% of multi-drug resistant MRSA were susceptible to trimethoprim-sulfamethoxazole, linezolid, and vancomycin. CONCLUSION: Prevalence of MRSA among both inpatient and outpatient specimens continues to increase with multi-drug resistance as a common phenotype. Continued emergence of outpatient MRSA that exhibit multi-drug resistant phenotypes has important implications for developing and evolving outpatient treatment guidelines.


Asunto(s)
Staphylococcus aureus/efectos de los fármacos , Farmacorresistencia Bacteriana Múltiple , Humanos , Laboratorios , Resistencia a la Meticilina , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...