Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Bone Joint J ; 100-B(1 Supple A): 9-16, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29292334

RESUMEN

The development and pre-clinical evaluation of nano-texturised, biomimetic, surfaces of titanium (Ti) implants treated with titanium dioxide (TiO2) nanotube arrays is reviewed. In vitro and in vivo evaluations show that TiO2 nanotubes on Ti surfaces positively affect the osseointegration, cell differentiation, mineralisation, and anti-microbial properties. This surface treatment can be superimposed onto existing macro and micro porous Ti implants creating a surface texture that also interacts with cells at the nano level. Histology and mechanical pull-out testing of specimens in rabbits indicate that TiO2 nanotubes improves bone bonding nine-fold (p = 0.008). The rate of mineralisation associated with TiO2 nanotube surfaces is about three times that of non-treated Ti surfaces. In addition to improved osseointegration properties, TiO2 nanotubes reduce the initial adhesion and colonisation of Staphylococcus epidermidis Collectively, the properties of Ti implant surfaces enhanced with TiO2 nanotubes show great promise. Cite this article: Bone Joint J 2018;100-B(1 Supple A):9-16.


Asunto(s)
Antiinfecciosos/farmacología , Nanotubos , Equipo Ortopédico/microbiología , Prótesis e Implantes/microbiología , Titanio/farmacología , Animales , Antiinfecciosos/administración & dosificación , Adhesión Bacteriana/efectos de los fármacos , Fenómenos Biomecánicos , Calcificación Fisiológica/efectos de los fármacos , Diferenciación Celular/efectos de los fármacos , Diseño de Equipo , Humanos , Oseointegración/efectos de los fármacos , Conejos , Propiedades de Superficie/efectos de los fármacos , Titanio/administración & dosificación
2.
Bone Joint J ; 99-B(1 Suppl): 46-49, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-28042118

RESUMEN

Nerve palsy is a well-described complication following total hip arthroplasty, but is highly distressing and disabling. A nerve palsy may cause difficulty with the post-operative rehabilitation, and overall mobility of the patient. Nerve palsy may result from compression and tension to the affected nerve(s) during the course of the operation via surgical manipulation and retractor placement, tension from limb lengthening or compression from post-operative hematoma. In the literature, hip dysplasia, lengthening of the leg, the use of an uncemented femoral component, and female gender are associated with a greater risk of nerve palsy. We examined our experience at a high-volume, tertiary care referral centre, and found an overall incidence of 0.3% out of 39 056 primary hip arthroplasties. Risk factors found to be associated with the incidence of nerve palsy at our institution included the presence of spinal stenosis or lumbar disc disease, age younger than 50, and smoking. If a nerve palsy is diagnosed, imaging is mandatory and surgical evacuation or compressive haematomas may be beneficial. As palsies are slow to recover, supportive care such as bracing, therapy, and reassurance are the mainstays of treatment. Cite this article: Bone Joint J 2017;99-B(1 Supple A):46-9.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Enfermedades del Sistema Nervioso Periférico/etiología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Alargamiento Óseo/efectos adversos , Manejo de la Enfermedad , Femenino , Neuropatía Femoral/diagnóstico , Neuropatía Femoral/epidemiología , Neuropatía Femoral/etiología , Neuropatía Femoral/terapia , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Enfermedades del Sistema Nervioso Periférico/diagnóstico , Enfermedades del Sistema Nervioso Periférico/epidemiología , Enfermedades del Sistema Nervioso Periférico/terapia , Pronóstico , Factores de Riesgo , Neuropatía Ciática/diagnóstico , Neuropatía Ciática/epidemiología , Neuropatía Ciática/etiología , Neuropatía Ciática/terapia , Adulto Joven
3.
Bone Joint J ; 98-B(1 Suppl A): 98-100, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26733652

RESUMEN

During the last ten years, greater attention has been given to the management of peri-operative blood loss after total knee arthroplasty (TKA), as it is a modifiable outcome that has a significant effect on the rate of complications, the recovery, and the economic burden. Blood loss after TKA has been greatly reduced during this time, thereby dramatically reducing the rates of allogeneic transfusion. This has significantly reduced the complications associated with transfusion, such as fluid overload, infection, and increased length of stay. The greatest advent in lowering peri-operative blood loss after TKA has been the introduction of tranexamic acid, which reduces blood loss without increasing the risk of thromboembolic events. This paper discusses the ways of reducing blood loss after TKA, for which a multimodal algorithm, with pre-, intra- and post-operative measures, has been adopted at our institution.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Pérdida de Sangre Quirúrgica/prevención & control , Algoritmos , Humanos , Atención Perioperativa/métodos
4.
Bone Joint J ; 96-B(11 Supple A): 43-7, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25381407

RESUMEN

Surgical interventions consisting of internal fixation (IF) or total hip replacement (THR) are required to restore patient mobility after hip fractures. Conventionally, this decision was based solely upon the degree of fracture displacement. However, in the last ten years, there has been a move to incorporate patient characteristics into the decision making process. Research demonstrating that joint replacement renders superior functional results when compared with IF, in the treatment of displaced femoral neck fractures, has swayed the pendulum in favour of THR. However, a high risk of dislocation has always been the concern. Fortunately, there are newer technologies and alternative surgical approaches that can help reduce the risk of dislocation. The authors propose an algorithm for the treatment of femoral neck fractures: if minimally displaced, in the absence of hip joint arthritis, IF should be performed; if arthritis is present, or the fracture is displaced, then THR is preferred.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/métodos , Prótesis de Cadera , Fracturas del Cuello Femoral/diagnóstico por imagen , Humanos , Radiografía
5.
Bone Joint Res ; 3(5): 150-4, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24842931

RESUMEN

OBJECTIVES: Metal-on-metal hip resurfacing (MOMHR) is available as an alternative option for younger, more active patients. There are failure modes that are unique to MOMHR, which include loosening of the femoral head and fractures of the femoral neck. Previous studies have speculated that changes in the vascularity of the femoral head may contribute to these failure modes. This study compares the survivorship between the standard posterior approach (SPA) and modified posterior approach (MPA) in MOMHR. METHODS: A retrospective clinical outcomes study was performed examining 351 hips (279 male, 72 female) replaced with Birmingham Hip Resurfacing (BHR, Smith and Nephew, Memphis, Tennessee) in 313 patients with a pre-operative diagnosis of osteoarthritis. The mean follow-up period for the SPA group was 2.8 years (0.1 to 6.1) and for the MPA, 2.2 years (0.03 to 5.2); this difference in follow-up period was statistically significant (p < 0.01). Survival analysis was completed using the Kaplan-Meier method. RESULTS: At four years, the Kaplan-Meier survival curve for the SPA was 97.2% and 99.4% for the MPA; this was statistically significant (log-rank; p = 0.036). There were eight failures in the SPA and two in the MPA. There was a 3.5% incidence of femoral head collapse or loosening in the SPA and 0.4% in the MPA, which represented a significant difference (p = 0.041). There was a 1.7% incidence of fractures of the femoral neck in the SPA and none in the MPA (p = 0.108). CONCLUSION: This study found a significant difference in survivorship at four years between the SPA and the MPA (p = 0.036). The clinical outcomes of this study suggest that preserving the vascularity of the femoral neck by using the MPA results in fewer vascular-related failures in MOMHRs. Cite this article: Bone Joint Res 2014;3:150-4.

6.
Bone Joint J ; 95-B(11 Suppl A): 53-6, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24187353

RESUMEN

Cementless femoral stems are currently preferred for total hip replacement (THR) in the United States. Improvements in stem design, instrumentation and surgical technique have made this technology highly successful, reproducible, and applicable to the vast majority of patients requiring a THR. However, there are ongoing developments in some aspects of stem design that influence clinical results, the incidence of complications and their inherent adaptability in accommodating the needs of individual patients. Here we examine some of these design features.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Fémur/cirugía , Prótesis de Cadera , Diseño de Prótesis , Fémur/diagnóstico por imagen , Humanos , Incidencia , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Radiografía , Propiedades de Superficie , Estados Unidos/epidemiología
7.
Bone Joint J ; 95-B(11 Suppl A): 88-91, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24187361

RESUMEN

Surface hip replacement (SHR) is generally used in younger, active patients as an alternative conventional total hip replacement in part because of the ability to preserve femoral bone. This major benefit of surface replacement will only hold true if revision procedures of SHRs are found to provide good clinical results. A retrospective review of SHR revisions between 2007 and 2012 was presented, and the type of revision and aetiologies were recorded. There were 55 SHR revisions, of which 27 were in women. At a mean follow-up of 2.3 years (0.72 to 6.4), the mean post-operative Harris hip score (HHS) was 94.8 (66 to 100). Overall 23 were revised for mechanical reasons, nine for impingement, 13 for metallosis, nine for unexplained pain and one for sepsis. Of the type of revision surgery performed, 14 were femoral-only revisions; four were acetabular-only revisions, and 37 were complete revisions. We did not find that clinical scores were significantly different between gender or different types of revisions. However, the mean post-operative HHS was significantly lower in patients revised for unexplained pain compared with patients revised for mechanical reasons (86.9 (66 to 100) versus 99 (96 to 100); p = 0.029). There were two re-revisions for infection in the entire cohort. Based on the overall clinical results, we believe that revision of SHR can have good or excellent results and warrants a continued use of the procedure in selected patients. Close monitoring of these patients facilitates early intervention, as we believe that tissue damage may be related to the duration of an ongoing problem. There should be a low threshold to revise a surface replacement if there is component malposition, rising metal ion levels, or evidence of soft-tissue abnormalities.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/estadística & datos numéricos , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Dimensión del Dolor , Selección de Paciente , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
8.
Bone Joint J ; 95-B(11 Suppl A): 135-9, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24187372

RESUMEN

Blood loss during total knee replacement (TKR) remains a significant concern. In this study, 114 patients underwent TKR, and were divided into two groups based on whether they received a new generation fibrin sealant intra-operatively, or a local infiltration containing adrenaline. Groups were then compared for mean calculated total blood volume (TBV) loss, transfusion rates, and knee range of movement. Mean TBV loss was similar between groups: fibrin sealant mean was 705 ml (281 to 1744), local adrenaline mean was 712 ml (261 to 2308) (p = 0.929). Overall, significantly fewer units of blood were transfused in the fibrin sealant group (seven units) compared with the local adrenaline group (15 units) (p = 0.0479). Per patient transfused, significantly fewer units of blood were transfused in the fibrin sealant group (1.0 units) compared with the local adrenaline group (1.67 units) (p = 0.027), suggesting that the fibrin sealant may reduce the need for multiple unit transfusions. Knee range of movement was similar between groups. From our results, it appears that application of this newer fibrin sealant results in blood loss and transfusion rates that are low and similar to previously applied fibrin sealants.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Pérdida de Sangre Quirúrgica/prevención & control , Adhesivo de Tejido de Fibrina/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Transfusión Sanguínea/estadística & datos numéricos , Volumen Sanguíneo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Rango del Movimiento Articular , Resultado del Tratamiento
9.
J Bone Joint Surg Br ; 94(11 Suppl A): 112-5, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23118396

RESUMEN

Fixed flexion deformities are common in osteoarthritic knees that are indicated for total knee arthroplasty. The lack of full extension at the knee results in a greater force of quadriceps contracture and energy expenditure. It also results in slower walking velocity and abnormal gait mechanics, overloading the contralateral limb. Residual flexion contractures after TKA have been associated with poorer functional scores and outcomes. Although some flexion contractures may resolve with time after surgery, a substantial percentage will become permanent. Therefore, it is essential to correct fixed flexion deformities at the time of TKA, and be vigilant in the post-operative course to maintain the correction. Surgical techniques to address pre-operative flexion contractures include: adequate bone resection, ligament releases, removal of posterior osteophytes, and posterior capsular releases. Post-operatively, extension can be maintained with focused physiotherapy, a specially modified continuous passive motion machine, a contralateral heel lift, and splinting.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Contractura/cirugía , Osteoartritis de la Rodilla/cirugía , Artroplastia de Reemplazo de Rodilla/rehabilitación , Contractura/etiología , Contractura/rehabilitación , Humanos , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/rehabilitación , Modalidades de Fisioterapia , Cuidados Posoperatorios/métodos , Factores de Riesgo
10.
J Bone Joint Surg Br ; 94(11 Suppl A): 153-6, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23118406

RESUMEN

Pain, swelling and inflammation are expected during the recovery from total knee arthroplasty (TKA) surgery. The severity of these factors and how a patient copes with them may determine the ultimate outcome of a TKA. Cryotherapy and compression are frequently used modalities to mitigate these commonly experienced sequelae. However, their effect on range of motion, functional testing, and narcotic consumption has not been well-studied. A prospective, multi-center, randomised trial was conducted to evaluate the effect of a cryopneumatic device on post-operative TKA recovery. Patients were randomised to treatment with a cryopneumatic device or ice with static compression. A total of 280 patients were enrolled at 11 international sites. Both treatments were initiated within three hours post-operation and used at least four times per day for two weeks. The cryopneumatic device was titrated for cooling and pressure by the patient to their comfort level. Patients were evaluated by physical therapists blinded to the treatment arm. Range of motion (ROM), knee girth, six minute walk test (6MWT) and timed up and go test (TUG) were measured pre-operatively, two- and six-weeks post-operatively. A visual analog pain score and narcotic consumption was also measured post-operatively. At two weeks post-operatively, both the treatment and control groups had diminished ROM and function compared to pre-operatively. Both groups had increased knee girth compared to pre- operatively. There was no significant difference in ROM, 6MWT, TUG, or knee girth between the 2 groups. We did find a significantly lower amount of narcotic consumption (509 mg morphine equivalents) in the treatment group compared with the control group (680 mg morphine equivalents) at up to two weeks postop, when the cryopneumatic device was being used (p < 0.05). Between two and six weeks, there was no difference in the total amount of narcotics consumed between the two groups. At six weeks, there was a trend toward a greater distance walked in the 6MWT in the treatment group (29.4 meters versus 7.9 meters, p = 0.13). There was a significant difference in the satisfaction scores of patients with their cooling regimen, with greater satisfaction in the treatment group (p < 0.0001). There was no difference in ROM, TUG, VAS, or knee girth at six weeks. There was no difference in adverse events or compliance between the two groups. A cryopneumatic device used after TKA appeared to decrease the need for narcotic medication from hospital discharge to 2 weeks post-operatively. There was also a trend toward a greater distance walked in the 6MWT. Patient satisfaction with the cryopneumatic cooling regimen was significantly higher than with the control treatment.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/rehabilitación , Crioterapia/instrumentación , Aparatos de Compresión Neumática Intermitente , Osteoartritis de la Rodilla/cirugía , Cuidados Posoperatorios/instrumentación , Complicaciones Posoperatorias/prevención & control , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Crioterapia/métodos , Edema/etiología , Edema/prevención & control , Prueba de Esfuerzo , Humanos , Artropatías/etiología , Artropatías/prevención & control , Articulación de la Rodilla/fisiología , Persona de Mediana Edad , Dolor Postoperatorio/prevención & control , Cuidados Posoperatorios/métodos , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función , Método Simple Ciego , Resultado del Tratamiento , Adulto Joven
11.
J Bone Joint Surg Br ; 94(10): 1339-43, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23015557

RESUMEN

The purpose of this study was to compare the amount of acetabular bone removed during hip resurfacing (HR) and cementless total hip replacement (THR), after controlling for the diameter of the patient's native femoral head. Based on a power analysis, 64 consecutive patients (68 hips) undergoing HR or THR were prospectively enrolled in the study. The following data were recorded intra-operatively: the diameter of the native femoral head, the largest reamer used, the final size of the acetabular component, the size of the prosthetic femoral head and whether a decision was made to increase the size of the acetabular component in order to accommodate a larger prosthetic femoral head. Results were compared using two-sided, independent samples Student's t-tests. A statistically significant difference was seen in the mean ratio of the size of the acetabular component to the diameter of the native femoral head (HR: 1.05 (SD 0.04) versus THR: 1.09 (SD 0.05); p < 0.001) and largest acetabular reamer used to the diameter of the native femoral head (HR: 1.03 (SD 0.04) versus THR: 1.09 (SD 0.05); p < 0.001). The ratios varied minimally when the groups were subdivided by gender, age and obesity. The decision to increase the size of the acetabular component to accommodate a larger femoral head occurred more often in the THR group (27% versus 9%). Despite the emphasis on avoiding damage to the femoral neck during HR, the ratio of the size of the acetabular component to the diameter of the native femoral head was larger in cementless THR than in HR.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Femenino , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
J Bone Joint Surg Br ; 90(9): 1158-63, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18757954

RESUMEN

We have reviewed 42 patients who had revision of metal-on-metal resurfacing procedures, mostly because of problems with the acetabular component. The revisions were carried out a mean of 26.2 months (1 to 76) after the initial operation and most of the patients (30) were female. Malpositioning of the acetabular component resulted in 27 revisions, mostly because of excessive abduction (mean 69.9 degrees ; 56 degrees to 98 degrees ) or insufficient or excessive anteversion. Seven patients had more than one reason for revision. The mean increase in the diameter of the component was 1.8 mm (0 to 4) when exchange was needed. Malpositioning of the components was associated with metallosis and a high level of serum ions. The results of revision of the femoral component to a component with a modular head were excellent, but four patients had dislocation after revision and four required a further revision.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Falla de Prótesis , Acetábulo/cirugía , Adolescente , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Fémur/cirugía , Luxación de la Cadera/etiología , Luxación Congénita de la Cadera/cirugía , Humanos , Masculino , Metales Pesados , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Osteonecrosis/cirugía , Reoperación , Resultado del Tratamiento
14.
Mol Microbiol ; 14(2): 243-54, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7830569

RESUMEN

A homologue of the bacterial cell division gene ftsZ was cloned from the filamentous bacterium Streptomyces coelicolor. The gene was located on the physical map of the chromosome at about '11 o'clock' (in the vicinity of glkA, hisA and trpB). Surprisingly, a null mutant in which the 399-codon ftsZ open reading frame was largely deleted was viable, even though the mutant was blocked in septum formation. This indicates that cell division may not be essential for the growth and viability of S. coelicolor. The ftsZ mutant was able to produce aerial hyphae but was unable to produce spores, a finding consistent with the idea that ftsZ is required in order for aerial hyphae to undergo septation into the uninucleoid cells that differentiate into spores.


Asunto(s)
Proteínas Bacterianas/genética , Proteínas del Citoesqueleto , Proteínas de Unión al GTP/genética , Streptomyces/genética , Secuencia de Aminoácidos , Proteínas Bacterianas/química , Proteínas Bacterianas/fisiología , Secuencia de Bases , División Celular , Mapeo Cromosómico , Cromosomas Bacterianos , Clonación Molecular , Proteínas de Unión al GTP/química , Proteínas de Unión al GTP/fisiología , Eliminación de Gen , Datos de Secuencia Molecular , Mutación , Sistemas de Lectura Abierta , Fenotipo , Esporas Bacterianas/fisiología , Streptomyces/crecimiento & desarrollo , Streptomyces/ultraestructura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...