Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Physiol Meas ; 39(9): 095004, 2018 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-30129925

RESUMEN

OBJECTIVE: A chromatic method is described for providing a preliminary indication of unacceptable bilirubin levels in a newly born baby in order to avoid the development of serious mental deficiencies. The aim was to investigate the reliability of a new chromatic approach using a novel template unit for a preliminary, non-invasive monitoring of the skin tissue of newly born babies with jaundice and its capability for use with different mobile phone cameras. APPROACH: A description of the monitoring system is given along with an explanation of the monitoring technique used. Preliminary tests have been performed on 48 different neonates each being addressed by one of six different mobile phone cameras, which were randomly available to the operating clinicians. MAIN RESULTS: The test results have a correlation (R 2) of 0.81, a sensitivity (Sn) of 0.97, a specificity (Sp) of 0.82, a positive predictive value (PPV) of 0.95 and a negative predictive value (NPV) of 0.9. SIGNIFICANCE: The significance of the results obtained is that they show the approach to have a high level of fail-safe reliability in indicating the bilirubin levels when compared with blood test results. The results also show that the approach can be used with a few different mobile phone cameras and that because of its non-invasive nature and its cost effectiveness, has the potential for remote use from a medical hospital to provide an immediate preliminary diagnosis.


Asunto(s)
Teléfono Celular , Interpretación de Imagen Asistida por Computador/métodos , Ictericia/diagnóstico por imagen , Imagen Óptica/métodos , Bilirrubina/sangre , Biomarcadores/sangre , Humanos , Recién Nacido , Imagen Óptica/instrumentación , Datos Preliminares , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Piel/diagnóstico por imagen
2.
Physiol Meas ; 35(5): 793-805, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24682226

RESUMEN

An approach is described for monitoring urine samples using a portable system based on chromatic techniques and for predicting urinary tract infection (UTI) from the results. The system uses a webcam-computer combination with the screen of a computer visual display unit as a tuneable illumination source. It is shown that the system can operate in a robust manner under ambient lighting conditions and with potential for use as a point of care test in primary care. The present approach combines information on urine liquid concentration and turbidity. Its performance in an exploratory study is compared with microbiological culture of 200 urine samples, of which 79 had bacterial growth >10(5) colony forming unit/millilitre (cfu ml(-1)) indicative of UTI. It is shown that both sensitivity and negative predictive value of 0.92 could be achieved.


Asunto(s)
Computadores , Atención Primaria de Salud , Urinálisis/instrumentación , Infecciones Urinarias/diagnóstico , Infecciones Urinarias/orina , Adolescente , Adulto , Anciano , Color , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA