1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(1): 41-50, 2014 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-24464063

RESUMEN

Computed tomography colonography (CTC) is a robust and reliable imaging test of the colon. Recent studies show good sensitivity for the identification of nonpolypoid (flat) lesions as well. The purpose of this study was to determine the accuracy and reproducibility of a volume-rendering (VR) and virtual gross pathology (VGP) technique for detecting a polypoid lesion phantom by varying slice thickness. The scan of a simulated house-made phantom was performed using a 16-slice CT scanner with varying combinations of tube voltage (120 kVp), effective exposure (100 mAs), detector configuration (16×0.75 mm), rotation time (0.75 s), helical pitch (0.688, 0.938, 1.066 and 1.188), reconstruction kernel (A, B and C), and section thickness/reconstruction interval (0.8/0.4, 1.0/0.5 and 1.5/0.75 mm). All image data were transferred to a three-dimensional workstation to assess multi-planar reformation (MPR), VR and VGP. Accuracy of volume measurement using the VR technique for quantitative analysis was compared using a paired t-test. Four radiological technologists also independently evaluated the visual score using the VGP technique for qualitative analysis, and their evaluations were compared using one-way analysis of variance with Fisher's protected least significant difference post-hoc test. There was a statistically significant difference in reproducibility between the three different slice thicknesses as to volume measurement and observer performance test (p<0.01 and p<0.05, respectively). Furthermore, the reproducibility improved when using thinner slices. In conclusion, VR and VGP techniques using a slice thickness of 0.8 mm made it possible to maintain accuracy and reproducibility when using CTC to detect polypoid lesions.


Asunto(s)
Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada Multidetector/métodos , Fantasmas de Imagen , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 58(7): 940-7, 2002 Jul.
Artículo en Japonés | MEDLINE | ID: mdl-12515962

RESUMEN

The purpose of this investigation was to accomplish reproducible radiography of single-leg standing lateral radiography of the knee by adjusting lateral rotation using a ruler to measure foot position. After preliminary assessment of three-dimensional CT of the knees of normal volunteers, the best adjustment of external rotation was estimated. A ruler was made for use in adjusting the angle of knee rotation by measuring foot rotation. Based on the foot rotation measured by this ruler, the positioning of radiography was adjusted to correct rotation. Rotation was estimated by the distance between the posterior edges of the lateral and medial femoral condyles. Fifteen-degree and 17.5-degree rotations were used for correction. Correction of rotation was 17 degrees on average. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate of lateral knee radiography.


Asunto(s)
Imagenología Tridimensional/métodos , Articulación de la Rodilla/diagnóstico por imagen , Pierna/fisiología , Postura/fisiología , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Pie/fisiología , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Articulación de la Rodilla/fisiología , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Rotación