Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
J Vasc Interv Radiol ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38670527

RESUMEN

PURPOSE: To evaluate the safety and efficacy of track cauterization for lung cryoablation through comparison of post-procedural adverse event (AE) rates. MATERIAL AND METHODS: Fifty-nine patients who underwent 164 percutaneous lung cryoablation between 2013 to 2018 were included in this retrospective study. The study cohort was subdivided into whether track cauterization was conducted at the end of the procedure. Also, the study cohort was subdivided into procedures conducted with 1 - 2 probes and 3 - 4 probes. Post-ablation AE rates were assessed by immediate and delayed (equal or more than one month), pneumothorax, hemothorax, pleural effusion, and whether intervention was required. Univariate and multivariate logistic regression analyses were used to compare differences in AE rates. RESULTS: Procedures with track cautery were 2.6 times less likely to exhibit pleural effusion (p=0.017). Procedures conducted with a higher number of probes were 3.8 times more likely to receive interventions (p<0.001), 1.6 times more likely to experience pneumothorax (p=0.037), and 2.1 times more likely to experience pleural effusion (p=0.003). History of lung surgery, increased number of probes, size of the probe, and absence of track cautery showed to be a significant predictor of AEs and need for interventions (p<0.05). CONCLUSIONS: Track cauterization in lung cryoablation proves to reduce pleural effusion, but no difference in pneumothorax or delayed AEs. Decreasing the number of probes leads to a lower rate of AEs.

2.
AJR Am J Roentgenol ; 222(2): e2330300, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37966037

RESUMEN

BACKGROUND. Treatment options for patients with interstitial lung disease (ILD) who develop stage I-II non-small cell lung cancer (NSCLC) are severely limited, given that surgical resection, radiation, and systemic therapy are associated with significant morbidity and mortality. OBJECTIVE. The aim of this study was to evaluate the safety and efficacy of percutaneous ablation of stage I-II NSCLC in patients with ILD. METHODS. This retrospective study included patients with ILD and stage I-II NSCLC treated with percutaneous ablation in three health systems between October 2004 and February 2023. At each site, a single thoracic radiologist, blinded to clinical outcomes, reviewed preprocedural chest CT examinations for the presence and type of ILD according to 2018 criteria proposed by the American Thoracic Society, European Respiratory Society, Japanese Respiratory Society, and Latin American Thoracic Society. The primary outcome was 90-day major (grade ≥ 3) adverse events, based on Common Terminology Criteria for Adverse Events (CTCAE) version 5.0. Secondary outcomes were hospital length of stay (HLOS), local tumor control, and overall survival (OS). RESULTS. The study included 33 patients (19 men, 14 women; median age, 78 years; 16 patients with Eastern Cooperative Oncology Group performance status ≤ 1) with ILD who underwent 42 percutaneous ablation sessions (21 cryoablations, 11 radiofrequency ablations, 10 microwave ablations) of 43 NSCLC tumors ((median tumor size, 1.6 cm; IQR, 1.4-2.5 cm; range, 0.7-5.4 cm; 37 stage I, six stage II). The extent of lung fibrosis was 20% or less in 24 patients; 17 patients had imaging findings of definite or probable usual interstitial pneumonia. The 90-day major adverse event rate was 14% (6/42), including one CTCAE grade 4 event. No acute ILD exacerbation or death occurred within 90 days after ablation. The median HLOS was 1 day (IQR, 0-2 days). Median imaging follow-up for local tumor control was 17 months (IQR, 11-32 months). Median imaging or clinical follow-up for OS was 16 months (IQR, 6-26 months). Local tumor control and OS were 78% and 77%, respectively, at 1 year and 73% and 46% at 2 years. CONCLUSION. Percutaneous ablation appears to be a safe and effective treatment option for stage I-II NSCLC in the setting of ILD after multidisciplinary selection. CLINICAL IMPACT. Patients with ILD and stage I-II NSCLC should be considered for percutaneous ablation given that they are frequently ineligible for surgical resection, radiation, and systemic therapy.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Enfermedades Pulmonares Intersticiales , Neoplasias Pulmonares , Masculino , Humanos , Femenino , Anciano , Carcinoma de Pulmón de Células no Pequeñas/complicaciones , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Estudios Retrospectivos , Enfermedades Pulmonares Intersticiales/complicaciones , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/cirugía , Resultado del Tratamiento
4.
J Vasc Interv Radiol ; 33(8): 964-971.e2, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35490932

RESUMEN

PURPOSE: To assess the cost effectiveness of microwave ablation (MWA) and stereotactic body radiotherapy (SBRT) for patients with inoperable stage I non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: A literature search was performed in MEDLINE with broad search clusters. A decision-analytic model was constructed over a 5-year period. The model incorporated treatment-related complications and long-term recurrence. All clinical parameters were derived from the literature with preference to long-term prospective trials. A healthcare payers' perspective was adopted. Outcomes were measured in quality-adjusted life years (QALYs) extracted from prior studies and U.S. dollars from Medicare reimbursements and prior studies. Base case calculations, probabilistic sensitivity analysis with 10,000 Monte Carlo simulations, and multiple 1- and 2-way sensitivity analyses were performed. RESULTS: MWA yielded a health benefit of 2.31 QALYs at a cost of $195,331, whereas SBRT yielded a health benefit of 2.33 QALYs at a cost of $225,271. The incremental cost-effectiveness ratio was $1,480,597/QALY, indicating that MWA is the more cost-effective strategy. The conclusion remains unchanged in probabilistic sensitivity analysis with MWA being the optimal cost strategy in 99.84% simulations. One-way sensitivity analyses revealed that MWA remains cost effective when its annual recurrence risk is <18.4% averaged over 5 years, when the SBRT annual recurrence risk is >1.44% averaged over 5 years, or when MWA is at least $7,500 cheaper than SBRT. CONCLUSIONS: MWA appears to be more cost effective than SBRT for patients with inoperable stage I NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radiocirugia , Anciano , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Análisis Costo-Beneficio , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Cadenas de Markov , Medicare , Microondas/efectos adversos , Estudios Prospectivos , Años de Vida Ajustados por Calidad de Vida , Radiocirugia/efectos adversos , Estados Unidos
5.
Transl Lung Cancer Res ; 11(2): 150-164, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35280317

RESUMEN

Background: Transbronchial microwave ablation (MWA) is a promising novel therapy. Despite advances in bronchoscopy and virtual navigation, real time image guidance of probe delivery is lacking, and distal maneuverability is limited. Cone-beam computed tomography (CBCT) based augmented fluoroscopy guidance using steerable sheaths may help overcome these shortcomings. The aim of this study was to evaluate feasibility and accuracy of augmented fluoroscopy guided transbronchial MWA with a steerable sheath and without a bronchoscope. Methods: In this prospective study, procedures were performed under general anesthesia. Extra-bronchial lung synthetic targets were placed percutaneously. Target and airways extracted from CBCT, with planned bronchial parking point close to the target were overlaid on live fluoroscopy. Endobronchial navigation was solely performed under augmented fluoroscopy guidance. A 6.5 Fr steerable sheath was parked in the bronchus per plan, and a flexible MWA probe was inserted coaxially then advanced through the bronchus wall towards the target. Final in-target position was confirmed by CBCT. Only one ablation of 100 W-5 min was performed per target. Animals were euthanized and pathology analysis of the lungs was performed. Results: Eighteen targets with a median largest diameter of 9 mm (interquartile range, 7-11 mm) were ablated in 9 pigs. Median needle-target center distance was 2 mm (interquartile range, 0-4 mm), and was higher for lower/middle than for upper lobes [0 mm (interquartile range, 0-4 mm) vs. 4 mm (interquartile range, 3-8 mm), P=0.04]. No severe complications or pneumothorax occurred. Two cases of rib fractures in the ablation zone resolved after medical treatment. Median longest axis of the ablation zone on post-ablation computed tomography was 38 mm (interquartile range, 30-40 mm). Histology showed coagulation necrosis of ablated tissue. Conclusions: Transbronchial MWA under augmented fluoroscopy guidance using a steerable sheath is feasible and accurate.

6.
Acad Radiol ; 29(9): 1413-1416, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35094948

RESUMEN

RATIONALE AND OBJECTIVES: Promotion is an important milestone in the career of academic radiologists. Appointments, Promotion and Tenure (APT) committees require multiple letters of support from both internal and external referees. Traditional narrative letters are highly subjective, have high inter-reader variability, are time-intensive, and vulnerable to gender and other biases. The Alliance of Directors and Vice Chairs of Education in Radiology (ADVICER) recognized the need for a standardized template to assist academic faculty, letter writers, and APT committees. MATERIALS AND METHODS: An ADVICER ad hoc committee of six educators with experience serving as external referees was convened to create a standardized template. Committee members performed a search of the relevant literature and internet sites, spoke with stakeholders such as APT chairs, and ultimately developed a template for faculty reviewer letters using the common clinician-educator pathway as a focal point. RESULTS: An open source, modifiable, standardized, template was produced. The template has been made available to ADVICER members and is available on the Association of University Radiologists (AUR) website at: https://www.aur.org/resources/Template-for-Faculty-Reviewer-Letters-for-Promotion-and-Appointment CONCLUSION: This external referee template has the potential to reduce subjectivity, eliminate bias, and provide a flexible, modifiable, comprehensive faculty review letter template which will be useful for academic faculty, letter writers, and promotions committees.


Asunto(s)
Docentes , Radiología , Movilidad Laboral , Docentes Médicos , Humanos , Radiología/educación
7.
J Vasc Interv Radiol ; 32(8): 1241.e1-1241.e12, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34332724

RESUMEN

PURPOSE: To state the Society of Interventional Radiology's position on the use of image-guided thermal ablation for the treatment of early stage non-small cell lung cancer, recurrent lung cancer, and metastatic disease to the lung. MATERIALS AND METHODS: A multidisciplinary writing group, with expertise in treating lung cancer, conducted a comprehensive literature search to identify studies on the topic of interest. Recommendations were drafted and graded according to the updated SIR evidence grading system. A modified Delphi technique was used to achieve consensus agreement on the recommendation statements. RESULTS: A total of 63 studies, including existing systematic reviews and meta-analysis, retrospective cohort studies, and single-arm trials were identified. The expert writing group developed and agreed on 7 recommendations on the use of image-guided thermal ablation in the lung. CONCLUSION: SIR considers image-guided thermal ablation to be an acceptable treatment option for patients with inoperable Stage I NSCLC, those with recurrent NSCLC, as well as patients with metastatic lung disease.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Ablación por Catéter , Neoplasias Pulmonares , Canadá , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Humanos , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Recurrencia Local de Neoplasia , Radiología Intervencionista , Estudios Retrospectivos
8.
J Vasc Interv Radiol ; 32(8): 1242.e1-1242.e10, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34000388

RESUMEN

PURPOSE: To provide guidance on quality improvement thresholds for outcomes and complications of image-guided thermal ablation for the treatment of early stage non-small cell lung cancer, recurrent lung cancer, and metastatic disease. MATERIALS AND METHODS: A multidisciplinary writing group conducted a comprehensive literature search to identify studies on the topic of interest. Data were extracted from relevant studies and thresholds were derived from a calculation of 2 standard deviations from the weighted mean of each outcome. A modified Delphi technique was used to achieve consensus agreement on the thresholds. RESULTS: Data from 29 studies, including systematic reviews and meta-analyses, retrospective cohort studies, and single-arm trials were extracted for calculation of the thresholds. The expert writing group agreed on thresholds for local control, overall survival and adverse events associated with image-guided thermal ablation. CONCLUSION: SIR recommends utilizing the indicator thresholds to review and assess the efficacy of ongoing quality improvement programs. When performance falls above or below specific thresholds, consideration of a review of policies and procedures to assess for potential causes, and to implement changes in practices, may be warranted.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Ablación por Catéter , Neoplasias Pulmonares , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Humanos , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Recurrencia Local de Neoplasia , Mejoramiento de la Calidad , Radiología Intervencionista , Estudios Retrospectivos
9.
J Vasc Interv Radiol ; 32(5): 729-738, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33608192

RESUMEN

PURPOSE: To assess the safety, feasibility, and efficacy of percutaneous thermal ablation (TA) in the treatment of metastatic gynecologic (GYN) tumors. MATERIALS AND METHODS: A study cohort of 42 consecutive women (mean age, 59. years; range, 25-78 years) with metastatic GYN tumors (119 metastatic tumors) treated with radiofrequency (n = 47 tumors), microwave (n = 47 tumors), or cryogenic (n = 30 tumors) ablation from over 2,800 ablations performed from January 2001 to January 2019 was identified. The primary GYN neoplasms consisted of ovarian (27 patients; 77 tumors; mean tumor diameter [MTD], 2.50 cm), uterine (7 patients; 26 tumors; MTD, 1.89 cm), endometrial (5 patients; 10 tumors; MTD, 2.8 cm), vaginal (2 patients; 5 tumors; MTD, 2.40 cm), and cervical (1 patient; 1 tumor; MTD, 1.90 cm) cancers. In order of descending frequency, metastatic tumors treated by TA were located in the liver or liver capsule (74%), lungs (13%), and peritoneal implants (9%). Single tumors were also treated in the kidneys, rectus muscle, perirectal soft tissue (2.5%), and retroperitoneal lymph nodes (1.6%). All efficacy parameters of TA and definitions of major and minor adverse events are categorized by the latest Society of Interventional Radiology reporting standards. RESULTS: The median follow-up of treated patients was 10 months. After the initial ablation, 95.6% of the patients achieved a complete tumor response confirmed by contrast-enhanced magnetic resonance imaging or computed tomography. On surveillance imaging, 8.5% of the ablated tumors developed local progression over a median follow-up period of 4.1 months. Five of 8 tumors with local recurrence underwent repeated treatment over a mean follow-up period of 18 months, and 4 of 5 tumors achieved complete eradication after 1 additional treatment session that resulted in a secondary efficacy of 80%. The overall technique efficacy of TA was 96.2% over a median follow-up period of 10 months. CONCLUSIONS: TA was safe and effective for the local control of metastatic GYN tumors in the lungs, abdomen, and pelvis, with an overall survival rate of 37.5 months and a local progression-free survival rate of 16.5 months, with only 4.8% of treated patients experiencing a major adverse event.


Asunto(s)
Técnicas de Ablación , Neoplasias de los Genitales Femeninos/cirugía , Cirugía Asistida por Computador , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/mortalidad , Adulto , Anciano , Progresión de la Enfermedad , Estudios de Factibilidad , Femenino , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Neoplasias de los Genitales Femeninos/mortalidad , Neoplasias de los Genitales Femeninos/patología , Humanos , Persona de Mediana Edad , Metástasis de la Neoplasia , Recurrencia Local de Neoplasia , Supervivencia sin Progresión , Estudios Retrospectivos , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/mortalidad , Factores de Tiempo
10.
J Clin Oncol ; 38(14): 1633-1640, 2020 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-32134701

RESUMEN

PURPOSE: National Cancer Institute (NCI)-sponsored clinical trial network studies frequently require biopsy specimens for pharmacodynamic and molecular biomarker analyses, including paired pre- and post-treatment samples. The purpose of this meeting of NCI-sponsored investigators was to identify local institutional standard procedures found to ensure quantitative and qualitative specimen adequacy. METHODS: NCI convened a conference on best biopsy practices, focusing on the clinical research community. Topics discussed were (1) criteria for specimen adequacy in the personalized medicine era, (2) team-based approaches to ensure specimen adequacy and quality control, and (3) risk considerations relevant to academic and community practitioners and their patients. RESULTS AND RECOMMENDATIONS: Key recommendations from the convened consensus panel included (1) establishment of infrastructure for multidisciplinary biopsy teams with a formalized information capture process, (2) maintenance of standard operating procedures with regular team review, (3) optimization of tissue collection and yield methodology, (4) incorporation of needle aspiration and other newer techniques, and (5) commitment of stakeholders to use of guideline documents to increase awareness of best biopsy practices, with the goal of universally improving tumor biopsy practices.


Asunto(s)
Biopsia/métodos , Ensayos Clínicos como Asunto/métodos , Neoplasias Hepáticas/cirugía , Neoplasias Pulmonares/cirugía , Humanos , National Cancer Institute (U.S.) , Resultado del Tratamiento , Estados Unidos
11.
J Thorac Oncol ; 15(7): 1200-1209, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32151777

RESUMEN

OBJECTIVE: To assess the safety and local recurrence-free survival in patients after cryoablation for treatment of pulmonary metastases. METHODS: This multicenter, prospective, single-arm, phase 2 study included 128 patients with 224 lung metastases treated with percutaneous cryoablation, with 12 and 24 months of follow-up. The patients were enrolled on the basis of the outlined key inclusion criteria, which include one to six metastases from extrapulmonary cancers with a maximal diameter of 3.5 cm. Time to progression of the index tumor(s), metastatic disease, and overall survival rates were estimated using the Kaplan-Meier method. Complications were captured for 30 days after the procedure, and changes in performance status and quality of life were also evaluated. RESULTS: Median size of metastases was 1.0 plus or minus 0.6 cm (0.2-4.5) with a median number of tumors of 1.0 plus or minus 1.2 cm (one to six). Local recurrence-free response (local tumor efficacy) of the treated tumor was 172 of 202 (85.1%) at 12 months and 139 of 180 (77.2%) at 24 months after the initial treatment. After a second cryoablation treatment for recurrent tumor, secondary local recurrence-free response (local tumor efficacy) was 184 of 202 (91.1%) at 12 months and 152 of 180 (84.4%) at 24 months. Kaplan-Meier estimates of 12- and 24-month overall survival rates were 97.6% (95% confidence interval: 92.6-99.2) and 86.6% (95% confidence interval: 78.7-91.7), respectively. Rate of pneumothorax that required pleural catheter placement was 26% (44/169). There were eight grade 3 complication events in 169 procedures (4.7%) and one (0.6%) grade 4 event. CONCLUSION: Percutaneous cryoablation is a safe and effective treatment for pulmonary metastases.


Asunto(s)
Criocirugía , Neoplasias Renales , Neoplasias Pulmonares , Humanos , Neoplasias Renales/cirugía , Neoplasias Pulmonares/cirugía , Recurrencia Local de Neoplasia/cirugía , Estudios Prospectivos , Calidad de Vida , Estudios Retrospectivos , Resultado del Tratamiento
12.
Acad Radiol ; 26(12): 1707-1717, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31171464

RESUMEN

RATIONALE AND OBJECTIVES: The Alliance of Directors and Vice Chairs in Education group identified the need to develop an education budget template as resource for our community. Having a framework and working knowledge of budgetary considerations is crucial to those with general oversight and executive managerial responsibility for departmental educational programs. METHODS: An online survey was sent to all the Alliance of Directors and Vice Chairs in Education members. Survey questions included education funding sources, presence of vice chair of finance, expectation of revenue generation, existing education budget, funding decision-makers, education budget formulation and approval, vice chair of education's role in budget, education budget line items, and income statement review. RESULTS: The survey response rate was 41/81 (51%). A majority 26/41 (63%) of respondents had an education budget that typically included funding for all medical students, residents, and fellows but only a minority of respondents report they developed 10/22 (45%), approved 6/22 (27%), or regularly reviewed 6/21 (29%) this budget. In sharp contrast was the role of department chairs and administrators, who presumably all participated in this process. To assist in education budget development and review, as well as meet the need to improve participants' financial accounting knowledge as a key tenet of faculty professional development, the authors developed sample budget templates and an income statement primer. CONCLUSION: Our survey results suggested the need for an educational budget framework and financial accounting resources for those in radiology education posts, and resources have been provided.


Asunto(s)
Presupuestos/organización & administración , Educación de Postgrado en Medicina/economía , Docentes Médicos/economía , Liderazgo , Desarrollo de Programa , Radiología/educación , Costos y Análisis de Costo , Humanos , Radiología/economía , Encuestas y Cuestionarios , Estados Unidos
13.
J Vasc Interv Radiol ; 29(5): 722-728, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29506902

RESUMEN

PURPOSE: To determine size of ablation zone and pulmonary hemorrhage in double-freeze (DF) vs modified triple-freeze (mTF) cryoablation protocols with different probe sizes in porcine lung. MATERIALS AND METHODS: In 10 healthy adult pigs, 20 pulmonary cryoablations were performed using either a 2.4-mm or a 1.7-mm probe. Either conventional DF or mTF protocol was used. Serial noncontrast CT scans were performed during ablations. Ablation iceball and hemorrhage volumes were measured and compared between protocols and probe sizes. RESULTS: With 1.7-mm probe, greater peak iceball volume was observed with DF compared with mTF, although difference was not statistically significant (16.1 mL ± 1.9 vs 8.8 mL ± 3.6, P = .07). With 2.4-mm probe, DF and mTF produced similar peak iceball volumes (14.0 mL ± 2.8 vs 14.6 mL ± 2.7, P = .88). Midcycle hemorrhage was significantly larger with DF with the 1.7-mm probe (94.3 mL ± 22.2 vs 19.6 mL ± 2.1, P = .02) and with both sizes combined (93.2 mL ± 17.5 vs. 50.9 mL ± 12.6, P = .048). Rate of hemorrhage increase was significantly higher in DF (10.4 mL/min vs 5.1 mL/min, P = .003). End-cycle hemorrhage was visibly larger in DF compared with mTF across probe sizes, although differences were not statistically significant (P = .14 for 1.7 mm probe, P = .18 for 2.4 mm probe, and P = .07 for both probes combined). Rate of increase in hemorrhage during the last thaw period was not statistically different between DF and mTF (3.0 mL/min vs 2.8 mL/min, P = .992). CONCLUSIONS: mTF reduced rate of midcycle hemorrhage compared with DF. With mTF, midcycle hemorrhage was significantly smaller with 1.7-mm probe; although noticeably smaller with 2.4-mm probe, statistical significance was not achieved. Iceball size was not significantly different across both protocols and probe types.


Asunto(s)
Criocirugía/métodos , Hemorragia/etiología , Pulmón/cirugía , Animales , Pulmón/diagnóstico por imagen , Modelos Animales , Medición de Riesgo , Factores de Riesgo , Porcinos , Tomografía Computarizada por Rayos X
14.
Pulm Circ ; 7(4): 813-820, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28782988

RESUMEN

Pulmonary tumor thrombotic microangiopathy (PTTM) is a disease process wherein tumor cells are thought to embolize to the pulmonary circulation causing pulmonary hypertension (PH) and death from right heart failure. Presented herein are clinical, laboratory, radiographic, and histologic features across seven cases of PTTM. Highlighted in this publication are also involvement of pulmonary venules and clinical features distinguishing PTTM from clinical mimics. We conducted a retrospective chart review of seven cases of PTTM from hospitals in the greater Los Angeles metropolitan area. Patients in this series exhibited: symptoms of cough and progressive dyspnea; PH and/or heart failure on physical exam; laboratory abnormalities of anemia, thrombocytopenia, elevated LDH, and elevated D-dimer; chest computed tomography (CT) showing diffuse septal thickening, mediastinal and hilar lymphadenopathy and nodules; elevated pulmonary artery pressures on transthoracic echocardiogram and/or right heart catheterization; and presence of malignancy. Tumor emboli and fibrocellular intimal proliferation were seen in pulmonary arterioles, while two patients had pulmonary venopathy. PTTM is a devastating disease occurring in patients with metastatic carcinoma. An early diagnosis is challenging. Understanding the clinical presentation of PTTM and distinguishing PTTM from clinical mimics may help achieve an early diagnosis and allow time for initiation of treatment.

16.
J Vasc Interv Radiol ; 28(2): 213-221, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27979596

RESUMEN

PURPOSE: To determine safety and early-term efficacy of CT-guided cryoablation for treatment of recurrent mesothelioma and assess risk factors for local recurrence. MATERIALS AND METHODS: During the period 2008-2012, 24 patients underwent 110 cryoablations for recurrent mesothelioma tumors in 89 sessions. Median patient age was 69 years (range, 48-82 y). Median tumor size was 30 mm (range, 9-113 mm). Complications were graded using Common Terminology Criteria for Adverse Events version 4.0 (CTCAE v4.0). Recurrence was diagnosed on CT or positron emission tomography/CT by increasing size, nodular enhancement, or hypermetabolic activity and analyzed using the Kaplan-Meier method. Cox proportional hazards model was used to determine covariates associated with local tumor recurrence. RESULTS: Median duration of follow-up was 14.5 months. Complications occurred in 8 of 110 cryoablations (7.3%). All but 1 complication were graded CTCAE v4.0 1 or 2. No procedure-related deaths occurred. Freedom from local recurrence was observed in 100% of cases at 30 days, 92.5% at 6 months, 90.8% at 1 year, 87.3% at 2 years, and 73.7% at 3 years. Tumor recurrence was diagnosed 4.5-24.5 months after cryoablation (mean 5.7 months). Risk of tumor recurrence was associated with a smaller ablative margin from the edge of tumor to iceball ablation margin (multivariate hazard ratio 0.68, CI 0.48-0.95, P = .024). CONCLUSIONS: CT-guided cryoablation is safe for local control of recurrent mesothelioma, with a low rate of complications and promising early-term efficacy. A smaller ablative margin may predispose to tumor recurrence.


Asunto(s)
Criocirugía/métodos , Neoplasias Pulmonares/cirugía , Mesotelioma/cirugía , Recurrencia Local de Neoplasia , Neoplasias Pleurales/cirugía , Anciano , Anciano de 80 o más Años , Criocirugía/efectos adversos , Supervivencia sin Enfermedad , Estudios de Factibilidad , Femenino , Humanos , Estimación de Kaplan-Meier , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Masculino , Márgenes de Escisión , Mesotelioma/diagnóstico por imagen , Mesotelioma/patología , Mesotelioma Maligno , Persona de Mediana Edad , Análisis Multivariante , Neoplasia Residual , Neoplasias Pleurales/diagnóstico por imagen , Neoplasias Pleurales/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones , Complicaciones Posoperatorias/etiología , Modelos de Riesgos Proporcionales , Radiografía Intervencional/métodos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Carga Tumoral
17.
Radiology ; 282(3): 903-912, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27755912

RESUMEN

Purpose To identify the variables and factors that affect the quantity and quality of nucleic acid yields from imaging-guided core needle biopsy. Materials and Methods This study was approved by the institutional review board and compliant with HIPAA. The authors prospectively obtained 232 biopsy specimens from 74 patients (177 ex vivo biopsy samples from surgically resected masses were obtained from 49 patients and 55 in vivo lung biopsy samples from computed tomographic [CT]-guided lung biopsies were obtained from 25 patients) and quantitatively measured DNA and RNA yields with respect to needle gauge, number of needle passes, and percentage of the needle core. RNA quality was also assessed. Significance of correlations among variables was assessed with analysis of variance followed by linear regression. Conditional probabilities were calculated for projected sample yields. Results The total nucleic acid yield increased with an increase in the number of needle passes or a decrease in needle gauge (two-way analysis of variance, P < .0001 for both). However, contrary to calculated differences in volume yields, the effect of needle gauge was markedly greater than the number of passes. For example, the use of an 18-gauge versus a 20-gauge biopsy needle resulted in a 4.8-5.7 times greater yield, whereas a double versus a single pass resulted in a 2.4-2.8 times greater yield for 18- versus 20-gauge needles, respectively. Ninety-eight of 184 samples (53%) had an RNA integrity number of at least 7 (out of a possible score of 10). Conclusion With regard to optimizing nucleic acid yields in CT-guided lung core needle biopsies used for genomic analysis, there should be a preference for using lower gauge needles over higher gauge needles with more passes. ©RSNA, 2016 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 21, 2016.


Asunto(s)
Genómica , Neoplasias Pulmonares/patología , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja , Femenino , Humanos , Pulmón/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
18.
J Vasc Interv Radiol ; 27(9): 1380-1386, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27566426

RESUMEN

PURPOSE: To investigate pulmonary microwave ablation metrics including ablation work, ablation resistance score, and involution. MATERIALS AND METHODS: Retrospective review was performed of 98 pulmonary tumor ablations using the NeuWave Certus Microwave Ablation System (NeuWave Medical, Madison, Wisconsin) in 71 patients (32 men and 39 women; mean age, 64.7 y ± 11.5). Ablation work was defined as sum of (power) * (time) * (number of antennas) for all phases during an ablation procedure. Ablation zone was measured on CT at 3 time points: after procedure, 1-3 months (mean 47 d), and 3-12 months (mean 292 d). Ablation zones were scored based on location for pulmonary lobe (upper = 1, middle/lingula = 2, lower = 3) and region (peripheral = 1, parenchymal = 2, central = 3), and the 2 were summed for ablation resistance score. RESULTS: Ablation zone on CT at 1-3 months was significantly smaller in regions with higher ablation resistance score (P < .05). There was a significant correlation between ablation work and ablation zone measured on CT performed after procedure (P < .001), at 1-3 months (P < .001), and at 3-12 months (P < .05). Ablation zone significantly decreased from after procedure to 1-3 months (P < .001) and from 1-3 months to 3-12 months (P < .001), with change from after procedure to 1-3 months significantly greater (P < .01). CONCLUSIONS: Pulmonary microwave ablation zone is significantly smaller in regions with higher ablation resistance score. Ablation work correlates to ablation zone with a nonlinear involution pattern in the first year and may be useful for planning before the procedure.


Asunto(s)
Técnicas de Ablación , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Técnicas de Ablación/efectos adversos , Anciano , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/patología , Masculino , Microondas/efectos adversos , Persona de Mediana Edad , Neoplasia Residual , Dinámicas no Lineales , Selección de Paciente , Valor Predictivo de las Pruebas , Radiografía Intervencional/métodos , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Carga Tumoral
19.
Am Soc Clin Oncol Educ Book ; 35: e460-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27249754

RESUMEN

Distant metastasis is common in non-small cell lung cancer (NSCLC) and typically associated with poor prognosis. Aggressive local therapy including surgery and/or radiation for limited metastatic disease from colorectal cancer and sarcoma is associated with survival benefit and has become part of the standard of care. In this article, we review the literature and ongoing studies concerning surgery, radiation, and radiofrequency ablation for oligometastatic NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Recurrencia Local de Neoplasia/radioterapia , Recurrencia Local de Neoplasia/cirugía , Carcinoma de Pulmón de Células no Pequeñas/patología , Humanos , Metástasis de la Neoplasia , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Pronóstico , Radiocirugia/métodos
20.
J Thorac Imaging ; 30(6): W63-5, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26439890

RESUMEN

Portable chest radiography is a fundamental and frequently utilized examination in the critically ill patient population. The chest radiograph often represents a timely investigation of new or rapidly evolving clinical findings and an evaluation of proper positioning of support tubes and catheters. Thoughtful consideration of the use of this simple yet valuable resource is crucial as medical cost containment becomes even more mandatory. This review addresses the role of chest radiography in the intensive care unit on the basis of the existing literature and as formed by a consensus of an expert panel on thoracic imaging through the American College of Radiology. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 3 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.


Asunto(s)
Cuidados Críticos/estadística & datos numéricos , Guías de Práctica Clínica como Asunto , Radiografía Torácica , Sociedades Médicas , Medicina Basada en la Evidencia , Humanos , Pacientes Internos , Unidades de Cuidados Intensivos , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...