Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Radiol Case Rep ; 19(7): 2724-2728, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38680741

RESUMEN

Vein of Galen malformation (VGM) is a rare congenital, uncommon intracerebral vascular anomaly rarely complicated with the development of brain abscess as secondary to primary infection or after endovascular treatment. We report a very rare finding of a vein of Galen aneurysm associated with a large brain abscess at the time of diagnosis. A 12-year-old boy with a high-grade fever, severe headache, and recurrent episodes of convulsions came into the radiology department of Kassala Advanced Diagnostic Center. On a Siemens 16-slice scanner, brain non-contrast enhanced computed tomography (NECT) and contrast enhanced CT (CECT) was used to determine the source of the acute headache and convulsions which revealed a right frontal peripherally enhancing cystic lesion measuring 5.7 × 4.7 × 5.3 cm2 surrounded by massive vasogenic edema causing mass effect with midline shift to the left side by 1.5 cm suggestive of brain abscess. There is evidence of another avidly enhancing lesion seen within the third ventricle continuous with a straight sinus surrounded by extensive vascular loops consistent with an aneurysm of the vein of Galen, it was causing compression of the cerebral aqueduct with upstream mild hydrocephalus with dilated both lateral ventricles. Late presentation, diagnosis, and treatment also lead to an increase in the morbidities and mortalities of such case conditions. Urgent intervention should be considered for better outcomes.

2.
Chemosphere ; 351: 141218, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38266876

RESUMEN

The widespread consumption of pharmaceutical drugs and their incomplete breakdown in organisms has led to their extensive presence in aquatic environments. The indiscriminate use of antibiotics, such as sulfonamides, has contributed to the development of drug-resistant bacteria and the persistent pollution of water bodies, posing a threat to human health and the safety of the environment. Thus, it is paramount to explore remediation technologies aimed at decomposing and complete elimination of the toxic contaminants from pharmaceutical wastewater. The review aims to explore the utilization of metal-oxide nanoparticles (MONPs) and graphitic carbon nitrides (g-C3N4) in photocatalytic degradation of sulfonamides from wastewater. Recent advances in oxidation techniques such as photocatalytic degradation are being exploited in the elimination of the sulfonamides from wastewater. MONP and g-C3N4 are commonly evolved nano substances with intrinsic properties. They possessed nano-scale structure, considerable porosity semi-conducting properties, responsible for decomposing wide range of water pollutants. They are widely applied for photocatalytic degradation of organic and inorganic substances which continue to evolve due to the low-cost, efficiency, less toxicity, and more environmentally friendliness of the materials. The review focuses on the current advances in the application of these materials, their efficiencies, degradation mechanisms, and recyclability in the context of sulfonamides photocatalytic degradation.


Asunto(s)
Grafito , Nanopartículas del Metal , Compuestos de Nitrógeno , Óxidos , Humanos , Sulfonamidas , Aguas Residuales , Sulfanilamida , Preparaciones Farmacéuticas , Catálisis
3.
Heliyon ; 9(11): e22451, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38034673

RESUMEN

Assessment of activity levels of radionuclides that exist in soil, granite, and charnockite rock samples is very crucial because it exhibits an enhanced elemental concentration of uranium (U) and thorium (Th) contributing higher natural background activity than usual in the environment and it may cause health risk to human health through the external and internal exposure. This study determined the radioactivity levels of 238U, 232Th, and 40K radionuclides in soil, granite, and charnockite rock samples collected from selected fields in Ekiti State, Nigeria using Caesium iodide CsI(Tl) scintillation gamma spectrometer. It also evaluated indices of the radiological parameters consisting of radium equivalent activity (Raeq), absorbed dose rate (DR), annual effective dose equivalent (AEDE), internal hazard index (Hin), and excess lifetime cancer risk (ELCR). The calculated average activity concentrations of 238U, 232Th, and 40K are 30.40 ± 0.71 Bq kg-1, 3.31 ± 0.05 Bq kg-1, and 222.25 ± 14.72 Bq kg-1, respectively, which were lower than their respective world average values. Comparatively, potassium concentrations in these collected samples have a higher value than concentrations of uranium and thorium (40K > 238U > 232Th). All the evaluated values of the radiological parameters (except DR) of the appraised radionuclides were below the global permissible limits. The granite rocks, charnockite rocks, and soils from Ekiti State in Nigeria do not pose any hazardous risk to humans, but continued monitoring is necessary when these materials are used as building materials, which cause long-term radiation exposure.

4.
Radiat Prot Dosimetry ; 199(18): 2174-2178, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37934995

RESUMEN

Present study concerns the radiological character of Malaysian honey. A total of 18 samples (representative of the various most common types) were obtained from various honey bee farms throughout the country. Using a high-purity germanium γ-ray spectroscopic system, the samples were analysed for the naturally occurring radionuclides 226Ra, 228Ra and 40K. The respective range of activities (in Bq/kg) was: 3.49 ± 0.35 to 4.51 ± 0.39, 0.99 ± 0.37 to 1.74 ± 0.39 and 41.37 ± 3.26 to 105.02 ± 6.91. The estimated associated committed effective doses were derived from prevailing data on national consumption of honey, the annual dose being found low compared with the UNSCEAR reference dose limit of 290 µSv y-1. The estimated threshold consumption rate for honey indicates a maximum intake of 339 g/d, which poses an insignificant radiological risk to public health; however, the total dietary exposure may not, the guidance level of 290 µSv y-1 being applicable to dietary intake of all foodstuffs. The study is in support of the cultivation of a healthy lifestyle, acknowledging prevailing radioactivity within the environment.


Asunto(s)
Monitoreo de Radiación , Radio (Elemento) , Animales , Radio (Elemento)/análisis , Radioisótopos de Potasio/análisis , Monitoreo de Radiación/métodos , Malasia , Dosis de Radiación , Torio/análisis
5.
Appl Radiat Isot ; 202: 111071, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37871398

RESUMEN

Due to the extended localized fluoroscopy, many radiographic exposures, and multiple procedures that might result in tissue reaction, patients and personnel received a significant radiation dose during interventional cardiology (IR) procedures. This study aims to calculate the radiation risk and assess patient and staff effective doses during IC procedures. Thirty-two patients underwent a Cath lab treatment in total. Ten Cath lab personnel, including six nurses, two cardiologists, and two X-ray technologists. Optical stimulating-luminescent dosimeters (OSL) (Al2O3:C) calibrated for this purpose were used to monitor both occupational and ambient doses. Using an automated OSL reader, these badges were scanned. The Air Kerma (mGy) and Kerma Area Products (KAP, mGy.cm2) have a mean and standard deviation (SD) of 371 ± 132 and 26052, respectively. The average personal dose equivalent (mSv) and its range for cardiologists, nurses and X ray technologists were 1.11 ± 0.21 (0.96-1.26), 0.84 ± 0.11 (0.68-1.16), and 0.68 ± 0.014 (0.12-0.13), respectively. The current study findings showed that the annual effective dose for cardiologists, nurses, and X-ray technologists was lesser than the yearly occupational dose limit of 20 mSv recommended by national and international guidelines. The patients' doses are comparable with some previously published studies and below the tissue reaction limits.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Humanos , Dosis de Radiación , Exposición Profesional/análisis , Radiografía , Fluoroscopía/efectos adversos , Fluoroscopía/métodos , Exposición a la Radiación/efectos adversos , Medición de Riesgo
6.
Front Pharmacol ; 14: 1218867, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37601050

RESUMEN

The field of cancer nanotheranostics is rapidly evolving, with cyclodextrin (CD)-based nanoparticles emerging as a promising tool. CDs, serving as nanocarriers, have higher adaptability and demonstrate immense potential in delivering powerful anti-cancer drugs, leading to promising and specific therapeutic outcomes for combating various types of cancer. The unique characteristics of CDs, combined with innovative nanocomplex creation techniques such as encapsulation, enable the development of potential theranostic treatments. The review here focuses mainly on the different techniques administered for effective nanotheranostics applications of CD-associated complex compounds in the domain of cancer treatments. The experimentations on various loaded drugs and their complex conjugates with CDs prove effective in in vivo results. Various cancers can have potential nanotheranostics cures using CDs as nanoparticles along with a highly efficient process of nanocomplex development and a drug delivery system. In conclusion, nanotheranostics holds immense potential for targeted drug delivery and improved therapeutic outcomes, offering a promising avenue for revolutionizing cancer treatments through continuous research and innovative approaches.

7.
J Radiol Prot ; 43(3)2023 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-37406624

RESUMEN

This study aims to introduce national diagnostic reference levels (NDRLs) for adult hybrid single photon emission computed tomography (SPECT-CT) in nuclear medicine (NM) departments in the Kingdom of Saudi Arabia. The administered activity (AA) of radiopharmaceuticals, volume-weighted computed tomography dose index (CTDIvol) and dose length product (DLP) for ten hybrid SPECT/CT examinations were collected and analysed for one year. The median of AA, CTDIvoland DLP for each dose quantity was derived and the suggested national DRLs were determined based on the 75thpercentile for all identified SPECT-CT examinations. A comparison of the defined adult NDRLs in Saudi Arabia with the published data of other countries was performed. Although there are no significant variations of the proposed NDRL of AA between countries, the proposed NDRLs of the integrated CT metrics exceed the published data in most procedures. NM departments are urged to consider optimisation for both image quality and radiation protection.


Asunto(s)
Niveles de Referencia para Diagnóstico , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Humanos , Dosis de Radiación , Arabia Saudita , Tomografía Computarizada por Rayos X/métodos , Valores de Referencia
8.
ACS Omega ; 8(21): 18591-18602, 2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37273611

RESUMEN

Efforts to produce microwave absorber materials that are inexpensive and environmentally friendly have become a means of greening the environment. The breakthrough can be focused on industrial waste and natural materials for functional purposes and how to enhance their performance. We successfully synthesized nickel slag/laterite soil (NS/LS) and nickel slag/iron sand (NS/IS) nanocomposites using a simple mechanical alloying technique, and the electromagnetic (EM) wave absorption capacities of the nanocomposites were measured using a vector network analyzer. The structural properties of the nanocomposites were analyzed by X-ray diffraction spectroscopy, where the results of the analysis showed that NS/IS has the largest crystallite size (15.69 nm) and the highest EM wave absorption performance. The optical properties of the nanocomposites were determined from their Fourier transform infrared spectra using the Kramers-Kronig relation. As determined through a quantitative analysis of the optical properties, the distance between the longitudinal and transversal optical phonon wavenumber positions (Δ(LO - TO) = 65 cm-1) is inversely proportional to the reflection loss. The surface morphologies of the nanocomposites were analyzed by scanning electron microscopy, and the particle diameters were observed by binary image and Gaussian distribution analyses. The nanocomposite surface exhibits a graded-like morphology, which indicates multiple reflections of the EM radiation, consequently reducing the EM interference. The best nanocomposite for an attenuated EM wave achieved a reflection loss of -39.14 dB at 5-8 GHz. A low penetration depth has implications for the electrical charge tuning of the storage and composite magnets. Finally, the EM absorption properties of NS/IS and NS/LS indicate a 2-mm-thick environmentally friendly nanocomposite for EM absorption.

9.
Life (Basel) ; 13(4)2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37109522

RESUMEN

Chest computed tomography (CT) plays a vital role in the early diagnosis, treatment, and follow-up of COVID-19 pneumonia during the pandemic. However, this raises concerns about excessive exposure to ionizing radiation. This study aimed to survey radiation doses in low-dose chest CT (LDCT) and ultra-low-dose chest CT (ULD) protocols used for imaging COVID-19 pneumonia relative to standard CT (STD) protocols so that the best possible practice and dose reduction techniques could be recommended. A total of 564 articles were identified by searching major scientific databases, including ISI Web of Science, Scopus, and PubMed. After evaluating the content and applying the inclusion criteria to technical factors and radiation dose metrics relevant to the LDCT protocols used for imaging COVID-19 patients, data from ten articles were extracted and analyzed. Technique factors that affect the application of LDCT and ULD are discussed, including tube current (mA), peak tube voltage (kVp), pitch factor, and iterative reconstruction (IR) algorithms. The CTDIvol values for the STD, LDCT, and ULD chest CT protocols ranged from 2.79-13.2 mGy, 0.90-4.40 mGy, and 0.20-0.28 mGy, respectively. The effective dose (ED) values for STD, LDCT, and ULD chest CT protocols ranged from 1.66-6.60 mSv, 0.50-0.80 mGy, and 0.39-0.64 mSv, respectively. Compared with the standard (STD), LDCT reduced the dose reduction by a factor of 2-4, whereas ULD reduced the dose reduction by a factor of 8-13. These dose reductions were achieved by applying scan parameters and techniques such as iterative reconstructions, ultra-long pitches, and fast spectral shaping with a tin filter. Using LDCT, the cumulative radiation dose of serial CT examinations during the acute period of COVID-19 may have been inferior or equivalent to that of conventional CT.

10.
Brain Sci ; 13(3)2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-36979267

RESUMEN

Numerous factors can contribute to the development of neurodegenerative disorders (NDs), such as Alzheimer's disease, Parkinson's disease, amyotrophic lateral sclerosis, Huntington's disease, and multiple sclerosis. Oxidative stress (OS), a fairly common ND symptom, can be caused by more reactive oxygen species being made. In addition, the pathological state of NDs, which includes a high number of protein aggregates, could make chronic inflammation worse by activating microglia. Carotenoids, often known as "CTs", are pigments that exist naturally and play a vital role in the prevention of several brain illnesses. CTs are organic pigments with major significance in ND prevention. More than 600 CTs have been discovered in nature, and they may be found in a wide variety of creatures. Different forms of CTs are responsible for the red, yellow, and orange pigments seen in many animals and plants. Because of their unique structure, CTs exhibit a wide range of bioactive effects, such as anti-inflammatory and antioxidant effects. The preventive effects of CTs have led researchers to find a strong correlation between CT levels in the body and the avoidance and treatment of several ailments, including NDs. To further understand the connection between OS, neuroinflammation, and NDs, a literature review has been compiled. In addition, we have focused on the anti-inflammatory and antioxidant properties of CTs for the treatment and management of NDs.

11.
Appl Radiat Isot ; 193: 110626, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36640699

RESUMEN

Breast cancer is a common malignancy for females (25% of female cancers) and also has low incidence in males. It was estimated that 1% of all breast malignancies occur in males with mortality rate about 20%, with annual increase in incidence. Risk factors include age, family history, exposure to ionizing radiation and high estrogen and low of androgens hormones level. Diagnosis and screening are challenging due to limiting effectiveness of breast cancer screening. Therefore, patients may expose to ionizing radiation that may contribute in breast cancer incidence in males. In literature, limited studies were published regarding radiation exposure for males during mammography. The objective of this research is to quantify patient doses during male mammogram and to estimate the projected radiogenic risk during the procedure. In total, 42 male patients were undergone mammogram for breast cancer diagnosis during two consecutive years. The mean and range of patient age (years) is 45 (23-80). The mean and standard deviation (SD) of the peak tube potential and tube current time product are 28.64 ± 2. and 149 ± 35.1, respectively. The mean, and range of patients' entrance surface air kerma (ESAK, mGy) per single breast procedure was 5.3 (0.47-27.5). Male patient's received comparable radiation dose per mammogram compared to female procedures. With increasing incidence of male breast cancer, proper guidelines are necessary for the mammographic procedure are necessary to reduce unnecessary radiation doses and radiogenic risk.


Asunto(s)
Neoplasias de la Mama , Exposición a la Radiación , Humanos , Femenino , Masculino , Dosis de Radiación , Mamografía/métodos , Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Exposición a la Radiación/análisis
12.
Appl Radiat Isot ; 193: 110648, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36669265

RESUMEN

Occupational radiation exposure can occur due to various human activities, including the use of radiation in medicine. Occupationally exposed personnel surpassing 7.4 millions, and respresent the biggest single group of employees who are exposed to artificial radiation sources at work. This study compares the occupational radiation dose levels for 145 workers in four different hospitals located in the Aseer region in Saudi Arabia. The occupational exposure was quantified using thermoluminescence dosimeters (TLD-100). The levels of annual occupational exposures in targeted hospitals were calculated and compared with the levels of the international atomic energy agency (IAEA) Safety Standards. An average yearly cumulative dose for the two consecutive years. The average, highest and lowest resulted occupational doses under examination in this work is 1.42, 3.9 mSv and 0.72 for workers in various diagnostic radiology procedures. The resulted annual effective dose were within the IAEA approved yearly dose limit for occupational exposure of workers over 18, which is 20 mSv. Staff should be monitored on a regular basis, according to current practice, because their annual exposure may surpass 15% of the annual effective doses.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Traumatismos por Radiación , Monitoreo de Radiación , Humanos , Monitoreo de Radiación/métodos , Dosis de Radiación , Radiografía , Exposición Profesional/análisis
13.
Appl Radiat Isot ; 190: 110452, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36183658

RESUMEN

CT scanning deliver much higher radiation doses than planar radiological procedures, which puts patients to high risks. This study measures and evaluates patient doses during chest and abdomen computed tomography procedures. Particular attention is given to measuring the dose to the equivalent breast (mSv) and to estimate the associated risks of breast cancer to young female patients (15-35 years). Data was obtained from standard examinations from three hospitals. The measured values of CT dose indexes, CTDI (mGy) as well as exposure-related parameters were used for assessment. Breast and effective doses were extrapolated using a software. The results showed remarkable variations of the mean organ equivalent doses for similar CT examinations in the studied hospitals. This could be attributed to the variation in CT scanning imaging technique, and clinical indications. The average effective dose to the chest was 7.9 mSv (2.3-47.0 mSv) and for the abdomen the mean dose was 6.6 mSv, ranging from (3.3-27 mSv). The breast received equivalent doses from chest and abdomen procedures as follows: 10.2 (1.6-33 mSv) and 10.1(2.3-19 mS) Sv respectively. Each procedure yielded high risks of breast cancer for young females. Implementation of accurate referral criteria is recommended to avoid unnecessary breast radiation exposure.


Asunto(s)
Neoplasias de la Mama , Tomografía Computarizada por Rayos X , Humanos , Femenino , Dosis de Radiación , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Mama/diagnóstico por imagen , Tórax , Neoplasias de la Mama/diagnóstico por imagen
14.
Nanomaterials (Basel) ; 12(17)2022 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-36080043

RESUMEN

In just a few years, the efficiency of perovskite-based solar cells (PSCs) has risen to 25.8%, making them competitive with current commercial technology. Due to the inherent advantage of perovskite thin films that can be fabricated using simple solution techniques at low temperatures, PSCs are regarded as one of the most important low-cost and mass-production prospects. The lack of stability, on the other hand, is one of the major barriers to PSC commercialization. The goal of this review is to highlight the most important aspects of recent improvements in PSCs, such as structural modification and fabrication procedures, which have resulted in increased device stability. The role of different types of hole transport layers (HTL) and the evolution of inorganic HTL including their fabrication techniques have been reviewed in detail in this review. We eloquently emphasized the variables that are critical for the successful commercialization of perovskite devices in the final section. To enhance perovskite solar cell commercialization, we also aimed to obtain insight into the operational stability of PSCs, as well as practical information on how to increase their stability through rational materials and device fabrication.

15.
Healthcare (Basel) ; 10(9)2022 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-36141413

RESUMEN

Magnetic resonance imaging (MRI) offers visual representations of the interior of a body for clinical analysis and medical intervention. The MRI process is subjected to a variety of image processing and machine learning approaches to identify, diagnose, and classify brain diseases as well as detect abnormalities. In this paper, we propose an improved classification method for distinguishing cancerous and noncancerous tumors from brain MRI images by using Log Polar Transformation (LPT) and convolutional neural networks (CNN). The LPT has been applied for feature extraction of rotation and scaling of distorted images, while the integration of CNN introduces a machine learning approach for the tumor classification of distorted images. The dataset was formed with images of seven different brain diseases, and the training set was formed by applying CNN with the extracted features. The proposed method is then evaluated in comparison to state-of-the-art algorithms, showing a definite improvement of the former. The obtained results show that the machine learning approach offers better classification with a success rate of about 96% in both plain brain MR images and rotation- and scale-invariant brain MR images. This work also successfully classified T-1 and T-2 weighted images of neoplastic and degenerative brain diseases. The obtained accuracy is perfected by several kernel procedures, while the combined performance of the two wavelet transformations and a strong dataset make our method robust and efficient. Since no earlier study on machine learning approaches with rotated and scaled brain MRI has come to our attention, it is expected that our proposed method introduces a new paradigm in this research field.

16.
Materials (Basel) ; 15(18)2022 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-36143497

RESUMEN

The strong localization of the electric and magnetic fields in metamaterial-based structures has attracted a new era of radiation fields in the microwave range. In this research work, we represent a double split ring enclosed nested meander-line-shaped metamaterial resonator with a high effective medium ratio layered on a dielectric substrate to enhance the sensitivity for the material characterization. Tailoring a metallic design and periodical arrangement of the split ring resonator in a subwavelength range introduced field enhancement and strong localization of the electromagnetic field. The design methodology is carried out through the optimization technique with different geometric configurations to increase the compactness of the design. The CST microwave studio is utilized for the extraction of the scattering computational value within the defined boundary condition. The effective parameters from the reflection and transmission coefficient are taken into account to observe the radiation characteristics for the interaction with the applied electromagnetic spectrum. The proposed metamaterial-based sensor exhibits high sensitivity for different dielectric materials with low permittivity values. The numerical data of the frequency deviation for the different dielectric constants have shown good agreement using the linear regression analysis where the sensitivity is R2 = 0.9894 and the figure of merit is R2 = 0.9978.

17.
3 Biotech ; 12(9): 191, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35910291

RESUMEN

In the present study we focused on the anti-asthmatic and antioxidant effects of Zingiber officinalis roscoe L. (ZO) aqueous extract. This study includes 20 adult male rats, which were grouped into four; Group I: control group; Group II: asthmatic group (Ovalbumin sensitized/challenge model, Oval group); Group III: received ovalbumin sensitized/challenge associated a dose of 207 mg/kg body weight (BW) of ZO (Oval + D1 group); Group IV: received ovalbumin sensitized/challenge associated a dose of 414 mg/k BW of ZO (Oval + D2 group). After 21 days, blood and lung samples were collected for biochemical, hematological, and histopathological analyses. The ameliorative effect of ZO phytochemical compounds was also assessed by in silico approach on transducer and activator of transcription 6 (STAT6) and tumor necrosis factor-α (TNF-α) receptors. The oxidative/antioxidative status was evaluated in the lung tissues. Our results show that ZO extract alleviated the ovalbumin-induced hematological and biochemical disruptions associated oxidative injury. In fact, white and red blood cells (WBC and RBC, respectively), aspartate aminotransaminase (ASAT), malondialdehyde (MDA), glutathione (GSH), and glutathione peroxidase (GPx) were significantly disrupted (p < 0.05) in Oval group and alleviated following ZO treatment. Besides, several histopathological features were outlined in lung tissues of Oval group. Interestingly, ZO was found to exert ameliorative effects on tissue level. In silico analyses, particularly the binding affinities, the number of H-bonds, the embedding distance and the molecular interactions of ZO phytochemical compounds with either STAT6 or TNF-α supported the in vivo results. These findings confirm the potential ethno-pharmacological effects of ZO against asthma and its associated complications.

18.
Front Chem ; 10: 930620, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35903193

RESUMEN

The use of Phyllanthus emblica (gooseberry) leaf extract to synthesize Boron-doped zinc oxide nanosheets (B-doped ZnO-NSs) is deliberated in this article. Scanning electron microscopy (SEM) shows a network of synthesized nanosheets randomly aligned side by side in a B-doped ZnO (15 wt% B) sample. The thickness of B-doped ZnO-NSs is in the range of 20-80 nm. B-doped ZnO-NSs were tested against both gram-positive and gram-negative bacterial strains including Staphylococcus aureus, Pseudomonas aeruginosa, Klebsiella pneumonia, and Escherichia coli. Against gram-negative bacterium (K. pneumonia and E. coli), B-doped ZnO displays enhanced antibacterial activity with 26 and 24 mm of inhibition zone, respectively. The mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), mean free path (MFP), half-value layer (HVL), and tenth value layer (TVL) of B-doped ZnO were investigated as aspects linked to radiation shielding. These observations were carried out by using a PTW® electron detector and VARIAN® irradiation with 6 MeV electrons. The results of these experiments can be used to learn more about the radiation shielding properties of B-doped ZnO nanostructures.

19.
Radiat Prot Dosimetry ; 198(16): 1238-1243, 2022 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-35870200

RESUMEN

Size-specific dose estimate (SSDE), which can be calculated by measuring the effective diameter (De) or water equivalent diameter (Dw) of the patient, is one of the recent approaches for verifying the individual doses during computer tomography (CT) examinations. This work aimed to compare the Dw estimated by the AutoWED tool and IndoseCT software and to investigate CT axial (ARH) and paediatric head (PH) protocols used in southern Saudi Arabia to calculate the dose received by paediatric patients using metrics of volume CT dose index (CTDIvol) and SSDE. The distribution between the ARH and PH protocols was 57.8 and 42.2%, respectively. There was no significant difference in Dw values between the AutoWED tool and the IndoseCT program (0.13%). Including CT table or other objects during estimation of Dw can lead to variation up to 11.4%. The impact of selecting IndoseCT options to identify the border of the patient may be part of the explanation for these variations. A strong linear relationship was obtained between De and Dw in paediatric head size (R2 = 0.96). Using IndoseCT, for 0-1.5, 1.5-5 and 5.0-18 age groups (years), the Dw was found to be 13.2, 15.3 and 16.8 cm, respectively. The SSDE for the PH protocol was substantially lower than that of the ARH protocol. As a result, education of the individuals engaging in paediatric CT examinations is necessary for dose optimization.


Asunto(s)
Radiometría , Tomografía Computarizada por Rayos X , Niño , Computadores , Humanos , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Agua
20.
Toxics ; 10(7)2022 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-35878252

RESUMEN

Heavy metal (HM) contaminated soil can affect human health via ingestion of foodstuffs, inhalation of soil dust, and skin contact of soil. This study estimates the level of some heavy metals in soils of industrial areas, and their exposures to human body via dietary intake of vegetables and other pathways. Mean concentrations of Cr, Fe, Cu, Zn, As and Pb in the studied soil were found to be 61.27, 27,274, 42.36, 9.77, 28.08 and 13.69 mg/kg, respectively, while in vegetables the respective values were 0.53, 119.59, 9.76, 7.14, 1.34 and 2.69 mg/kg. Multivariate statistical analysis revealed that Fe, Cu, Zn, and Pb originated from lithogenic sources, while Cr and As are derived from anthropogenic sources. A moderate enrichment was noted by Cr, As, and Pb in the entire sampling site, indicating a progressive depletion of soil quality. The bioaccumulation factor (BCF) value for all the vegetables was recorded as BCF < 1; however, the metal pollution index (MPI) stipulates moderately high value of heavy metal accumulation in the vegetable samples. Hazard Index (HI) of >0.1 was estimated for adults but >1 for children by direct soil exposure, whereas HI < 1 for both children and adults via dietary intake of vegetables. Estimated Total carcinogenic risk (TCR) value due to soil exposure showed safe for adults but unsafe for children, while both the population groups were found to be safe via food consumption. Children are found more vulnerable receptors than adults, and health risks (carcinogenic and non-carcinogenic) via direct soil exposure proved unsafe. Overall, this study can be used as a reference for similar types of studies to evaluate heavy metal contaminated soil impact on the population of Bangladesh and other countries as well.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...