Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Nat Commun ; 15(1): 3900, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724552

RESUMEN

By incompletely understood mechanisms, type 2 (T2) inflammation present in the airways of severe asthmatics drives the formation of pathologic mucus which leads to airway mucus plugging. Here we investigate the molecular role and clinical significance of intelectin-1 (ITLN-1) in the development of pathologic airway mucus in asthma. Through analyses of human airway epithelial cells we find that ITLN1 gene expression is highly induced by interleukin-13 (IL-13) in a subset of metaplastic MUC5AC+ mucus secretory cells, and that ITLN-1 protein is a secreted component of IL-13-induced mucus. Additionally, we find ITLN-1 protein binds the C-terminus of the MUC5AC mucin and that its deletion in airway epithelial cells partially reverses IL-13-induced mucostasis. Through analysis of nasal airway epithelial brushings, we find that ITLN1 is highly expressed in T2-high asthmatics, when compared to T2-low children. Furthermore, we demonstrate that both ITLN-1 gene expression and protein levels are significantly reduced by a common genetic variant that is associated with protection from the formation of mucus plugs in T2-high asthma. This work identifies an important biomarker and targetable pathways for the treatment of mucus obstruction in asthma.


Asunto(s)
Asma , Proteínas Ligadas a GPI , Interleucina-13 , Lectinas , Mucina 5AC , Moco , Niño , Humanos , Asma/genética , Asma/metabolismo , Citocinas , Células Epiteliales/metabolismo , Proteínas Ligadas a GPI/genética , Proteínas Ligadas a GPI/metabolismo , Interleucina-13/genética , Interleucina-13/metabolismo , Lectinas/genética , Lectinas/metabolismo , Mucina 5AC/genética , Mucina 5AC/metabolismo , Moco/metabolismo , Mucosa Nasal/metabolismo , Polimorfismo Genético , Mucosa Respiratoria/metabolismo
2.
Artículo en Inglés | MEDLINE | ID: mdl-38651338

RESUMEN

Secreted deoxyribonucleases (DNases), such as DNase-1 and DNase-IL3, degrade extracellular DNA, and endogenous DNases have roles in resolving airway inflammation and guarding against autoimmune responses to nucleotides. Subsets of patients with asthma have high airway DNA levels, but information about DNase activity in health and in asthma is lacking. To characterize DNase activity in health and in asthma, we developed a novel kinetic assay using a Taqman probe sequence that is quickly cleaved by DNase-I to produce a large product signal. We used this kinetic assay to measure DNase activity in sputum from participants in the Severe Asthma Research Program (SARP)-3 (n=439) and from healthy controls (n=89). We found that DNase activity was lower than normal in asthma (78.7 RFU/min vs 120.4 RFU/min, p<0.0001). Compared to asthma patients with sputum DNase activity levels in the upper tertile activity levels, those in the lower tertile of sputum DNase activity were characterized clinically by more severe disease and pathologically by airway eosinophilia and airway mucus plugging. Carbamylation of DNase-I, a post translational modification that can be mediated by eosinophil peroxidase, inactivated DNase-I. In summary, a Taqman probe-based DNase activity assay uncovers low DNase activity in the asthma airway which is associated with more severe disease and airway mucus plugging and may be caused, at least in part, by eosinophil-mediated carbamylation.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38663815

RESUMEN

BACKGROUND: The relative utility of eosinophil peroxidase (EPX) and blood and sputum eosinophil counts as disease biomarkers in asthma is uncertain. OBJECTIVE: We sought to determine the utility of EPX as a biomarker of systemic and airway eosinophilic inflammation in asthma. METHODS: EPX protein was measured by immunoassay in serum and sputum in 110 healthy controls to establish a normal reference range and in repeated samples of serum and sputum collected during 3 years of observation in 480 participants in the Severe Asthma Research Program 3. RESULTS: Over 3 years, EPX levels in patients with asthma were higher than normal in 27% to 31% of serum samples and 36% to 53% of sputum samples. Eosinophils and EPX correlated better in blood than in sputum (rs values of 0.74 and 0.43, respectively), and high sputum EPX levels occurred in 27% of participants with blood eosinophil counts less than 150 cells/µL and 42% of participants with blood eosinophil counts between 150 and 299 cells/µL. Patients with persistently high sputum EPX values for 3 years were characterized by severe airflow obstruction, frequent exacerbations, and high mucus plug scores. In 59 patients with asthma who started mepolizumab during observation, serum EPX levels normalized in 96% but sputum EPX normalized in only 49%. Lung function remained abnormal even when sputum EPX normalized. CONCLUSIONS: Serum EPX is a valid protein biomarker of systemic eosinophilic inflammation in asthma, and sputum EPX levels are a more sensitive biomarker of airway eosinophilic inflammation than sputum eosinophil counts. Eosinophil measures in blood frequently miss airway eosinophilic inflammation, and mepolizumab frequently fails to normalize airway eosinophilic inflammation even though it invariably normalizes systemic eosinophilic inflammation.

4.
JCI Insight ; 9(3)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38127464

RESUMEN

BACKGROUNDInformation about the size, airway location, and longitudinal behavior of mucus plugs in asthma is needed to understand their role in mechanisms of airflow obstruction and to rationally design muco-active treatments.METHODSCT lung scans from 57 patients with asthma were analyzed to quantify mucus plug size and airway location, and paired CT scans obtained 3 years apart were analyzed to determine plug behavior over time. Radiologist annotations of mucus plugs were incorporated in an image-processing pipeline to generate size and location information that was related to measures of airflow.RESULTSThe length distribution of 778 annotated mucus plugs was multimodal, and a 12 mm length defined short ("stubby", ≤12 mm) and long ("stringy", >12 mm) plug phenotypes. High mucus plug burden was disproportionately attributable to stringy mucus plugs. Mucus plugs localized predominantly to airway generations 6-9, and 47% of plugs in baseline scans persisted in the same airway for 3 years and fluctuated in length and volume. Mucus plugs in larger proximal generations had greater effects on spirometry measures than plugs in smaller distal generations, and a model of airflow that estimates the increased airway resistance attributable to plugs predicted a greater effect for proximal generations and more numerous mucus plugs.CONCLUSIONPersistent mucus plugs in proximal airway generations occur in asthma and demonstrate a stochastic process of formation and resolution over time. Proximal airway mucus plugs are consequential for airflow and are in locations amenable to treatment by inhaled muco-active drugs or bronchoscopy.TRIAL REGISTRATIONClinicaltrials.gov; NCT01718197, NCT01606826, NCT01750411, NCT01761058, NCT01761630, NCT01716494, and NCT01760915.FUNDINGAstraZeneca, Boehringer-Ingelheim, Genentech, GlaxoSmithKline, Sanofi-Genzyme-Regeneron, and TEVA provided financial support for study activities at the Coordinating and Clinical Centers beyond the third year of patient follow-up. These companies had no role in study design or data analysis, and the only restriction on the funds was that they be used to support the SARP initiative.


Asunto(s)
Asma , Humanos , Broncoscopía , Pulmón/diagnóstico por imagen , Moco , Tomografía Computarizada por Rayos X
5.
Am J Respir Crit Care Med ; 209(10): 1196-1207, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38113166

RESUMEN

Rationale: Density thresholds in computed tomography (CT) lung scans quantify air trapping (AT) at the whole-lung level but are not informative for AT in specific bronchopulmonary segments. Objectives: To apply a segment-based measure of AT in asthma to investigate the clinical determinants of AT in asthma. Methods: In each of 19 bronchopulmonary segments in CT lung scans from 199 patients with asthma, AT was categorized as present if lung attenuation was less than -856 Hounsfield units at expiration in ⩾15% of the lung area. The resulting AT segment score (0-19) was related to patient outcomes. Measurements and Main Results: AT varied at the lung segment level and tended to persist at the patient and lung segment levels over 3 years. Patients with widespread AT (⩾10 segments) had more severe asthma (P < 0.05). The mean (±SD) AT segment score in patients with a body mass index ⩾30 kg/m2 was lower than in patients with a body mass index <30 kg/m2 (3.5 ± 4.6 vs. 5.5 ± 6.3; P = 0.008), and the frequency of AT in lower lobe segments in obese patients was less than in upper and middle lobe segments (35% vs. 46%; P = 0.001). The AT segment score in patients with sputum eosinophils ⩾2% was higher than in patients without sputum eosinophilia (7.0 ± 6.1 vs. 3.3 ± 4.9; P < 0.0001). Lung segments with AT more frequently had airway mucus plugging than lung segments without AT (48% vs. 18%; P ⩽ 0.0001). Conclusions: In patients with asthma, air trapping is more severe in those with airway eosinophilia and mucus plugging, whereas those who are obese have less severe trapping because their lower lobe segments are spared.


Asunto(s)
Asma , Eosinofilia , Obesidad , Tomografía Computarizada por Rayos X , Humanos , Asma/diagnóstico por imagen , Asma/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/fisiopatología , Adulto , Eosinofilia/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Anciano , Índice de Masa Corporal
6.
Am J Respir Crit Care Med ; 207(11): e77-e96, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37260227

RESUMEN

Background: Patients with mild asthma are believed to represent the majority of patients with asthma. Disease-associated risks such as exacerbations, lung function decline, and death have been understudied in this patient population. There have been no prior efforts from major societies to describe research needs in mild asthma. Methods: A multidisciplinary, diverse group of 24 international experts reviewed the literature, identified knowledge gaps, and provided research recommendations relating to mild asthma definition, pathophysiology, and management across all age groups. Research needs were also investigated from a patient perspective, generated in conjunction with patients with asthma, caregivers, and stakeholders. Of note, this project is not a systematic review of the evidence and is not a clinical practice guideline. Results: There are multiple unmet needs in research on mild asthma driven by large knowledge gaps in all areas. Specifically, there is an immediate need for a robust mild asthma definition and an improved understanding of its pathophysiology and management strategies across all age groups. Future research must factor in patient perspectives. Conclusions: Despite significant advances in severe asthma, there remain innumerable research areas requiring urgent attention in mild asthma. An important first step is to determine a better definition that will accurately reflect the heterogeneity and risks noted in this group. This research statement highlights the topics of research that are of the highest priority. Furthermore, it firmly advocates the need for engagement with patient groups and for more support for research in this field.


Asunto(s)
Asma , Humanos , Estados Unidos , Asma/diagnóstico , Asma/terapia , Sociedades Médicas , Cuidadores
7.
J Allergy Clin Immunol Pract ; 11(9): 2767-2777, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37245736

RESUMEN

BACKGROUND: The Global Initiative for Asthma and National Asthma Education and Prevention Program recently made paradigm-shifting recommendations regarding inhaler management in asthma. The Global Initiative for Asthma now recommends that combination inhaled corticosteroid (ICS)-formoterol inhalers replace short-acting ß-agonists as the preferred reliever therapy at all steps of asthma management. Although the most recent guidelines of the National Asthma Education and Prevention Program did not review reliever ICS-formoterol usage in mild asthma, they similarly recommended single maintenance and reliever therapy (SMART) at steps 3 and 4 of asthma management. Despite these recommendations, many clinicians-particularly in the United States-are not prescribing new inhaler paradigms. Clinician-level reasons for this implementation gap remain largely unexplored. OBJECTIVE: To gain an in-depth understanding of the facilitators and barriers to prescribing reliever ICS-formoterol inhalers and SMART in the United States. METHODS: Community and academic primary care providers, pulmonologists, and allergists who reported regularly caring for adults with asthma were interviewed. Interviews were recorded, transcribed, qualitatively coded, and analyzed using the Consolidated Framework for Implementation Research. Interviews were continued until theme saturation. RESULTS: Among 20 interviewed clinicians, only 6 clinicians described regularly prescribing ICS-formoterol inhalers as a reliever inhaler (either alone or within SMART). Significant barriers to new inhaler approaches included concerns surrounding a lack of Food and Drug Administration labeling for ICS-formoterol as a reliever therapy, a lack of awareness regarding a patient's formulary-preferred ICS-long-acting ß-agonist choices, the high cost of combination inhalers, and time constraints. Facilitators to using new inhaler approaches included clinicians' beliefs that the latest inhaler recommendations are simpler and more congruent with real-world patients' behavior, and that a potential change in management strategy would offer a valuable opportunity for shared decision making. CONCLUSIONS: Although new guidelines exist in asthma, many clinicians described significant barriers to using them including medicolegal issues, pharmaceutical formulary confusion, and high drug costs. Nonetheless, most clinicians believed that the latest inhaler approaches would be more intuitive for their patients and would offer an opportunity for patient-centered collaboration and care. Stakeholders may find these results useful in future attempts to increase the real-world adoption of recent asthma recommendations.


Asunto(s)
Antiasmáticos , Asma , Adulto , Humanos , Estados Unidos/epidemiología , Budesonida/uso terapéutico , Antiasmáticos/uso terapéutico , Etanolaminas/uso terapéutico , Administración por Inhalación , Asma/tratamiento farmacológico , Combinación Budesonida y Fumarato de Formoterol/uso terapéutico , Fumarato de Formoterol/uso terapéutico , Nebulizadores y Vaporizadores , Corticoesteroides/uso terapéutico , Combinación de Medicamentos
9.
Trials ; 23(1): 975, 2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-36471430

RESUMEN

BACKGROUND: While inhaled corticosteroids (ICS) are considered the essential foundation of most asthma therapy, ICS inhaler nonadherence is a notoriously common problem and a significant cause of asthma-related morbidity. Partially acknowledging the problem of nonadherence, international organizations recently made paradigm-shifting recommendations that all patients with mild-to-moderate persistent asthma be considered for symptom-driven ICS-containing inhalers rather than relying on adherence to traditional maintenance ICS inhalers and symptom-driven short-acting beta-agonists (SABA). With this new approach, asthma patients are at least exposed to the important anti-inflammatory effects of ICS-containing inhalers when their symptom reliever inhaler is deployed due to acute symptoms. METHODS: This study will (Part 1) complete a pragmatic randomized controlled trial to evaluate if an inhaler strategy that utilizes symptom-driven ICS inhalers is particularly beneficial in maintenance ICS inhaler non-adherent asthma patients, and (Part 2) use a dissemination and implementation (D&I) science conceptual framework to better understand patients' and providers' views of inhaler nonadherence. This study, which will have an option of taking place entirely remotely, will use a Food and Drug Administration (FDA)-approved electronic sensor (Hailie® sensor) to monitor inhaler adherence and includes semi-structured interviews guided by the Consolidated Framework for Implementation Research (CFIR). DISCUSSION: This study is assessing the problem of nonadherence using a D&I implementation science research lens while testing a new inhaler approach to potentially ameliorate the detrimental consequences of maintenance inhaler nonadherence. We hypothesize that the use of a symptom-driven ICS/LABA management strategy, as compared to traditional maintenance ICS treatment and symptom-driven SABA, will lead to improved adherence to an asthma treatment strategy, decreased asthma-related morbidity, less cumulative ICS exposure, and greater patient satisfaction with an inhaler approach. TRIAL REGISTRATION: ClinicalTrials.gov NCT05111262. Registered on November 8, 2021.


Asunto(s)
Antiasmáticos , Asma , Adulto , Humanos , Administración por Inhalación , Corticoesteroides/efectos adversos , Antiasmáticos/efectos adversos , Asma/diagnóstico , Asma/tratamiento farmacológico , Nebulizadores y Vaporizadores , Ensayos Clínicos Controlados Aleatorios como Asunto
10.
Res Involv Engagem ; 8(1): 63, 2022 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-36434672

RESUMEN

BACKGROUND: The effects of stakeholder engagement, particularly in comparative effectiveness trials, have not been widely reported. In 2014, eight comparative effectiveness studies targeting African Americans and Hispanics/Latinos with uncontrolled asthma were funded by the Patient-Centered Outcomes Research Institute (PCORI) as part of its Addressing Disparities Program. Awardees were required to meaningfully involve patients and other stakeholders. Using specific examples, we describe how these stakeholders substantially changed the research protocols and in other ways participated meaningfully as full partners in the development and conduct of the eight studies. METHODS: Using the method content analysis of cases, we identified themes regarding the types of stakeholders, methods of engagement, input from the stakeholders, changes made to the research protocols and processes, and perceived benefits and challenges of the engagement process. We used summaries from meetings of the eight teams, results from an engagement survey, and the final research reports as our data source to obtain detailed information. The descriptive data were assessed by multiple reviewers using inductive and deductive qualitative methods and discussed in the context of engagement literature. RESULTS: Stakeholders participated in the planning, conduct, and dissemination phases of all eight asthma studies. All the studies included clinicians and community representatives as stakeholders. Other stakeholders included patients with asthma, their caregivers, advocacy organizations, and health-system representatives. Engagement was primarily by participation in advisory boards, although six of the eight studies (75%) also utilized focus groups and one-on-one interviews. Difficulty finding a time and location to meet was the most reported challenge to engagement, noted by four of the eight teams (50%). Other reported challenges and barriers to engagement included recruitment of stakeholders, varying levels of enthusiasm among stakeholders, controlling power dynamics, and ensuring that stakeholder involvement was reflected and had true influence on the project. CONCLUSION: Engagement-driven modifications led to specific changes in study design and conduct that were felt to have increased enrollment and the general level of trust and support of the targeted communities. The level of interaction described, between investigators and stakeholders in each study and between investigator-stakeholder groups, is-we believe-unprecedented and may provide useful guidance for other studies seeking to improve the effectiveness of community-driven research.


The goal of comparative clinical effectiveness research is to compare healthcare options and learn which work best for patients depending on their preferences and circumstances. Research efforts can be more effective when researchers engage stakeholders, such as patients, healthcare providers, and other members of the community­especially those communities or groups targeted by the planned research. Stakeholders can give their input throughout the research process to make sure the study will address questions and concerns that are most important and useful for participants. In 2014, the PCORI funded eight research studies that evaluated various ways to help African Americans and Hispanics/Latinos with poorly controlled asthma. These groups are underrepresented in asthma research but have higher rates of and more severe asthma for reasons that are poorly understood. The goal of this report is to show how stakeholders­including patients with asthma from these underrepresented groups, healthcare providers who care for patients with asthma, key representatives from the communities and others­participated as full partners in the eight studies and helped to improve the overall quality of the research and the relationship between the researchers and the community.

11.
Chronic Obstr Pulm Dis ; 9(4): 510-519, 2022 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-35998338

RESUMEN

Background: Patients with chronic obstructive pulmonary disease (COPD) are at higher risk for severe coronavirus disease 2019 (COVID-19). From the pandemic's onset there has been concern regarding effects on health and well-being of high-risk patients. Methods: This was an ancillary study to the Losartan Effects on Emphysema Progression (LEEP) Trial and was designed to collect descriptive information longitudinally about the health and wellbeing of COPD patients who were enrolled in a clinical trial. Participants were interviewed by telephone about their health status every 2 weeks and their mental health, knowledge, and behaviors every 8 weeks from June 2020 to April 2021. There were no pre-specified hypotheses. Results: We enrolled 157 of the 220 participants from the parent LEEP trial. Their median age was 69 years, 55% were male, and 82% were White; median forced expiratory volume in 1 second (FEV1)% predicted was 48%. Nine confirmed COVID-19 infections were reported, 2 resulting in hospitalization. Rates of elevated anxiety or depressive symptoms were 8% and 19% respectively in June 2020 and remained relatively stable during follow-up. By April 2021, 85% of participants said they were "very likely" to receive a vaccine; 91% were vaccinated (≥1 dose) by the end of December 2021. Conclusion: Our select cohort of moderate to severe COPD patients who were well integrated into a health care network coped well with the COVID-19 pandemic. Few participants were diagnosed with COVID-19, levels of depression and anxiety were stable, most adopted accepted risk reduction behaviors, and did not become socially isolated; most were vaccinated by the end of 2021.

12.
Am J Respir Crit Care Med ; 206(9): 1096-1106, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-35687105

RESUMEN

Rationale: The role of obesity-associated insulin resistance (IR) in airflow limitation in asthma is uncertain. Objectives: Using data in the Severe Asthma Research Program 3 (SARP-3), we evaluated relationships between homeostatic measure of IR (HOMA-IR), lung function (cross-sectional and longitudinal analyses), and treatment responses to bronchodilators and corticosteroids. Methods: HOMA-IR values were categorized as without (<3.0), moderate (3.0-5.0), or severe (>5.0). Lung function included FEV1 and FVC measured before and after treatment with inhaled albuterol and intramuscular triamcinolone acetonide and yearly for 5 years. Measurements and Main Results: Among 307 participants in SARP-3, 170 (55%) were obese and 140 (46%) had IR. Compared with patients without IR, those with IR had significantly lower values for FEV1 and FVC, and these lower values were not attributable to obesity effects. Compared with patients without IR, those with IR had lower FEV1 responses to ß-adrenergic agonists and systemic corticosteroids. The annualized decline in FEV1 was significantly greater in patients with moderate IR (-41 ml/year) and severe IR (-32 ml/year,) than in patients without IR (-13 ml/year, P < 0.001 for both comparisons). Conclusions: IR is common in asthma and is associated with lower lung function, accelerated loss of lung function, and suboptimal lung function responses to bronchodilator and corticosteroid treatments. Clinical trials in patients with asthma and IR are needed to determine if improving IR might also improve lung function.


Asunto(s)
Asma , Resistencia a la Insulina , Humanos , Estudios Transversales , Broncodilatadores/uso terapéutico , Pulmón , Corticoesteroides/uso terapéutico , Obesidad/complicaciones , Volumen Espiratorio Forzado
13.
J Pediatr ; 246: 207-212.e1, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35247394

RESUMEN

OBJECTIVES: To identify pediatric patient-reported outcomes (PROs) that are associated with chronic conditions and to evaluate the effects of chronic disease activity on PROs. STUDY DESIGN: Participants (8-24 years old) and their parents were enrolled into 14 studies that evaluated Patient-Reported Outcome Measurement Information System PROs across 10 chronic conditions-asthma, atopic dermatitis, cancer, cancer survivors, chronic kidney disease, Crohn's disease, juvenile idiopathic arthritis, lupus, sickle cell disease, and type 1 diabetes mellitus. PRO scores were contrasted with the US general population of children using nationally representative percentiles. PRO-specific coefficients of variation were computed to illustrate the degree of variation in scores within vs between conditions. Condition-specific measures of disease severity and Cohen d effect sizes were used to examine PRO scores by disease activity. RESULTS: Participants included 2975 child respondents and 2392 parent respondents who provided data for 3409 unique children: 52% were 5-12 years old, 52% female, 25% African American/Black, and 14% Hispanic. Across all 10 chronic conditions, children reported more anxiety, fatigue, pain, and mobility restrictions than the general pediatric population. Variation in PRO scores within chronic disease cohorts was equivalent to variation within the general population, exceeding between-cohort variation by factors of 1.9 (mobility) to 5.7 (anxiety). Disease activity was consistently associated with poorer self-reported health, and these effects were weakest for peer relationships. CONCLUSIONS: Chronic conditions are associated with symptoms and functional status in children and adolescents across 10 different disorders. These findings highlight the need to complement conventional clinical evaluations with those obtained directly from patients themselves using PROs.


Asunto(s)
Asma , Medición de Resultados Informados por el Paciente , Adolescente , Adulto , Ansiedad , Asma/complicaciones , Niño , Preescolar , Enfermedad Crónica , Fatiga/complicaciones , Femenino , Humanos , Masculino , Calidad de Vida , Autoinforme , Adulto Joven
14.
Chest ; 161(1): 26-39, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34543667

RESUMEN

Asthma is a common chronic airways disease with significant impact on patients, caregivers, and the health care system. Although most research and novel interventions mainly have focused on patients with uncontrolled severe asthma, most patients with asthma have mild disease. Epidemiologic studies suggest that many patients with mild asthma report frequent exacerbations of the disease and uncontrolled symptoms. However, despite its impact, mild asthma does not have either a uniformly agreed on definition for or a consensus on its clinical and pathophysiologic progression. More recently, the approach to treatment of patients with mild asthma has undergone significant changes primarily based on emerging evidence that airway inflammation in this population is important. This led to clinical research studies that explored the efficacy of as-needed inhaled corticosteroids along with the rescue medications that traditionally have been the mainstay of treatment. Despite some advancement in the field in recent years, many controversies and unmet needs remain. In this review, we examine the current understanding of the pathophysiologic features and management of mild asthma. In addition, we outline unmet needs for future research. We conclude that mild asthma contributes significantly to the morbidity and mortality of asthma and should be the focus of future research.


Asunto(s)
Asma/tratamiento farmacológico , Broncodilatadores/uso terapéutico , Glucocorticoides/uso terapéutico , Administración por Inhalación , Remodelación de las Vías Aéreas (Respiratorias) , Asma/fisiopatología , Toma de Decisiones Clínicas , Manejo de la Enfermedad , Progresión de la Enfermedad , Prueba de Óxido Nítrico Exhalado Fraccionado , Humanos , Inflamación , Evaluación de Necesidades , Índice de Severidad de la Enfermedad
15.
Ann Allergy Asthma Immunol ; 127(1): 116-122.e7, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33781936

RESUMEN

BACKGROUND: Treatments for long-term control of asthma have improved and include a promising but expensive class of biologic therapies. However, the clinical trials evaluating these and other novel treatments have used a variety of different outcomes to evaluate efficacy. The evolution of asthma care calls for a re-examination of outcomes that are most important to patients and other stakeholders. OBJECTIVE: To develop a core set of outcomes to be measured in phase 3 and phase 4 clinical drug trials in patients with moderate-to-severe asthma. METHODS: We used a robust and in-depth multistakeholder consensus process bringing together patients, clinicians, regulators, payers, health technology assessors, researchers, and product developers to reach consensus on outcomes. We used a modified Delphi method to reach consensus, an approach adapted from the Core Outcome Measures in Effectiveness Trials Initiative aligned with contemporary methodological standards for core outcome set development. RESULTS: The following outcomes were included in the final core set: severe asthma exacerbation, change in asthma control, asthma-specific or severe asthma-specific quality of life, asthma-specific hospital stay (ie, >24-hour stays at any level of care) or admission, and asthma-specific emergency department visit. CONCLUSION: These 5 outcomes represent a minimum set of core outcomes for use in phase 3 and phase 4 clinical drug trials in moderate-to-severe asthma. Consistent collection of these outcomes as minimum, independent of whether additional heterogeneous primary or secondary outcomes are included, will allow for meaningful comparisons of the effect of asthma therapies across clinical trials.


Asunto(s)
Asma/terapia , Determinación de Punto Final/normas , Pulmón/fisiopatología , Evaluación de Resultado en la Atención de Salud/métodos , Asma/diagnóstico , Asma/mortalidad , Asma/fisiopatología , Ensayos Clínicos como Asunto , Consenso , Técnica Delphi , Humanos , Investigación Cualitativa , Calidad de Vida , Literatura de Revisión como Asunto , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Participación de los Interesados , Resultado del Tratamiento
16.
Lancet Respir Med ; 9(5): 457-466, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33524320

RESUMEN

BACKGROUND: Bronchial thermoplasty is an endoscopic treatment for uncontrolled asthma. Previous randomised clinical trials have shown that bronchial thermoplasty reduces severe exacerbations in people with asthma. However, the long-term efficacy and safety of bronchial thermoplasty beyond 5 years is unknown. The BT10+ study aimed to investigate the efficacy and safety of bronchial thermoplasty after 10 or more years of follow-up. METHODS: BT10+ was an international, multicentre, follow-up study of participants who were previously enrolled in the AIR, RISA, and AIR2 trials and who had 10 or more years of follow-up since bronchial thermoplasty treatment. Data on patient demographics, quality of life, lung function, CT scans (AIR2 participants only), severe exacerbations, and health-care use during the previous year were collected at the BT10+ 10-year outcomes study visit. The primary effectiveness endpoint was durability of the thermoplasty treatment effect, determined by comparing the proportion of participants who had severe exacerbations during the first and fifth years after bronchial thermoplasty treatment with the proportion of participants who had severe exacerbations during the 12-month period before the BT10+ visit. The primary safety endpoint was the absence of clinically significant post-treatment respiratory image changes after bronchial thermoplasty, defined as bronchiectasis or bronchial stenosis as confirmed by pulmonary volumetric high-resolution CT scan at the BT10+ visit (AIR2 participants only). All analyses were done on an intention-to-treat basis. The trial is registered with ClinicalTrials.gov, NCT03243292. The last patient was enrolled on Dec 11, 2018. The last patient completed follow-up on Jan 10, 2019. FINDINGS: The BT10+ study enrolled 192 (45%) of the 429 participants who were enrolled in the AIR, RISA, and AIR2 trials. The BT10+ participants comprised 136 who received bronchial thermoplasty (52% of the 260 participants who received bronchial thermoplasty in the original trials), and 56 sham or control participants (33% of 169 from the original trials). 18 (32%) sham or control participants received bronchial thermoplasty after the previous trials concluded. The participants included in BT10+ were followed for 10·8-15·6 years (median 12·1 years) post-treatment. Baseline characteristics were similar between participants enrolled in BT10+ and those not enrolled. Participants treated with bronchial thermoplasty had similar proportions of severe exacerbations at the BT10+ visit (34 [25%] of 136 participants) compared with 1 year (33 [24%] of 135 participants; difference 0·6%, 95% CI -9·7 to 10·8) and 5 years (28 [22%] of 130 participants; difference 3·5%, -6·7% to 13·6) after treatment. Quality of life measurements and spirometry were similar between year 1, year 5, and the BT10+ visit. At the BT10+ study visit, pulmonary high-resolution CT scans from AIR2 participants treated with bronchial thermoplasty showed that 13 (13%) of 97 participants had bronchiectasis. When compared with baseline high-resolution CT scans, six (7%) of 89 participants treated with bronchial thermoplasty who did not have bronchiectasis at baseline had developed bronchiectasis after treatment (5 classified as mild, 1 classified as moderate). Participants treated with bronchial thermoplasty after the original study and participants in the sham or control group also had reductions in severe exacerbations at the BT10+ visit compared with baseline. INTERPRETATION: Our findings suggest that efficacy of bronchial thermoplasty is sustained for 10 years or more, with an acceptable safety profile. Therefore, bronchial thermoplasty is a long-acting therapeutic option for patients with asthma that remains uncontrolled despite optimised medical treatment. FUNDING: Boston Scientific.


Asunto(s)
Asma , Termoplastia Bronquial , Pulmón , Calidad de Vida , Asma/fisiopatología , Asma/psicología , Asma/terapia , Termoplastia Bronquial/efectos adversos , Termoplastia Bronquial/métodos , Broncoscopía/métodos , Demografía/estadística & datos numéricos , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria/métodos , Brote de los Síntomas , Tiempo , Resultado del Tratamiento
17.
Clin Exp Allergy ; 50(12): 1342-1351, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32909660

RESUMEN

BACKGROUND: The anti-interleukin 13 (IL-13) monoclonal antibody lebrikizumab improves lung function in patients with moderate-to-severe uncontrolled asthma, but its effects on airway inflammation and remodelling are unknown. CLAVIER was designed to assess lebrikizumab's effect on eosinophilic inflammation and remodelling. OBJECTIVE: To report safety and efficacy results from enrolled participants with available data from CLAVIER. METHODS: We performed bronchoscopy on patients with uncontrolled asthma before and after 12 weeks of randomized double-blinded treatment with lebrikizumab (n = 31) or placebo (n = 33). The pre-specified primary end-point was relative change in airway subepithelial eosinophils per mm2 of basement membrane (cells/mm2 ). Pre-specified secondary and exploratory outcomes included change in IL-13-associated biomarkers and measures of airway remodelling. RESULTS: There was a baseline imbalance in tissue eosinophils and high variability between treatment groups. There was no discernible change in adjusted mean subepithelial eosinophils/mm2 in response to lebrikizumab (95% CI, -82.5%, 97.5%). As previously observed, FEV1 increased after lebrikizumab treatment. Moreover, subepithelial collagen thickness decreased 21.5% after lebrikizumab treatment (95% CI, -32.9%, -10.2%), and fractional exhaled nitric oxide, CCL26 and SERPINB2 mRNA expression in bronchial tissues also reduced. Lebrikizumab was well tolerated, with a safety profile consistent with other lebrikizumab asthma studies. CONCLUSIONS & CLINICAL RELEVANCE: We did not observe reduced tissue eosinophil numbers in association with lebrikizumab treatment. However, in pre-specified exploratory analyses, lebrikizumab treatment was associated with reduced degree of subepithelial fibrosis, a feature of airway remodelling, as well as improved lung function and reduced key pharmacodynamic biomarkers in bronchial tissues. These results reinforce the importance of IL-13 in airway pathobiology and suggest that neutralization of IL-13 may reduce asthmatic airway remodelling. CLINICAL TRIAL REGISTRATION: NCT02099656.


Asunto(s)
Remodelación de las Vías Aéreas (Respiratorias)/efectos de los fármacos , Antiasmáticos/uso terapéutico , Anticuerpos Monoclonales/uso terapéutico , Asma/tratamiento farmacológico , Eosinófilos/efectos de los fármacos , Interleucina-13/antagonistas & inhibidores , Pulmón/efectos de los fármacos , Adolescente , Adulto , Anciano , Antiasmáticos/efectos adversos , Antiasmáticos/farmacocinética , Anticuerpos Monoclonales/efectos adversos , Anticuerpos Monoclonales/farmacocinética , Asma/inmunología , Asma/fisiopatología , Método Doble Ciego , Eosinófilos/inmunología , Eosinófilos/metabolismo , Femenino , Humanos , Pulmón/inmunología , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Transducción de Señal , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
18.
J Allergy Clin Immunol Pract ; 8(10): 3474-3481, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32693214

RESUMEN

BACKGROUND: Biomarkers that can predict loss of asthma control among patients being considered for step-down therapy in well-controlled disease are lacking. OBJECTIVE: To evaluate whether baseline biomarkers of type 2 airway inflammation and/or serial measurement of fractional exhaled nitric oxide (Feno) predict loss of asthma control as therapy is stepped down. METHODS: In subanalyses of a multicenter randomized, double-blind, parallel 3-arm trial comparing strategies for step-down therapy in well-controlled asthma (Long-Acting Beta-Agonist Step-Down Study), we assessed whether baseline atopy as determined by serum aeroallergen allergy screening test (Phadiatop), baseline serum eosinophil peroxidase, or baseline or serial Feno measurements during follow-up predicted the time to loss of asthma control among participants. Loss of asthma control was defined in the study protocol. We analyzed these associations in adjusted models including all participants, after testing for interactions with assignment to each of the 3 treatment groups (continuation of stable dose of combination inhaled corticosteroid-long-acting beta-agonist, step-down of inhaled corticosteroid, or discontinuation of long-acting bronchodilator). RESULTS: Four hundred forty-seven of the 553 Long-Acting Beta-Agonist Step-Down Study participants who were randomized to 1 of 3 treatment arms and had at least 1 biomarker measurement were included in this analysis. At baseline, higher levels of Feno were significantly associated with greater levels of multiallergen IgE levels (P < .001), but not with serum eosinophil peroxidase (P = .742). Among all participants as a group, elevations in baseline biomarkers were not predictive of a higher risk of treatment failure. In addition, Feno levels measured serially at 6-week intervals demonstrated that compared with participants with low levels (<25 parts per billion), those with intermediate (25-50 parts per billion) and high (>50 parts per billion) levels did not have significantly increased likelihood of subsequent treatment failure (hazard ratios, 1.03 [95% CI, 0.59-1.78] and 1.29 [95% CI, 0.65-2.54], respectively). There were no significant interactions of treatment group and baseline biomarkers. CONCLUSIONS: In patients with well-controlled asthma, neither baseline levels of type 2 airway inflammatory biomarkers nor serial measures of Feno are strong predictors of treatment failure.


Asunto(s)
Asma , Asma/diagnóstico , Asma/tratamiento farmacológico , Biomarcadores , Pruebas Respiratorias , Espiración , Humanos , Inflamación , Óxido Nítrico
19.
J Allergy Clin Immunol Pract ; 8(6): 2121-2122, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32499042
20.
J Allergy Clin Immunol Pract ; 8(1): 176-185.e2, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31371165

RESUMEN

BACKGROUND: Symptom-based adjustment (SBA) of inhaled corticosteroids may be an alternative patient-centered approach in which day-to-day inhaled corticosteroid use is adjusted by symptoms and short-acting ß-agonist need. OBJECTIVE: To evaluate the effectiveness of SBA in the primary care setting. METHODS: We conducted a randomized, open-label, pragmatic equivalence trial in African-American children (6-17 years old) with mild asthma managed by 12 primary care providers (PCPs). A total of 206 participants were randomized to SBA (as-needed beclomethasone 80 µg with rescue short-acting ß-agonist) or provider-based guideline-directed adjustment (PBA): maintenance beclomethasone 80 µg/d (6-11 years old), 160 µg/d (12-17 years old), with subsequent guideline-based dose adjustment by PCPs. PCPs implemented both treatment assignments, with outcomes measured by blinded staff. All participants received symptom recognition and albuterol use education from peer educators. Primary outcome was change in asthma control (measured by Asthma Control Test [ACT]/childhood ACT [cACT]) over 12 months. RESULTS: Participants had adequately controlled asthma (mean ACT or cACT score = 21.6 ± 2.8) at baseline. After 1 year, there was no significant between-group difference in change in ACT scores (SBA - PBA): ACT: -0.88 (95% CI, -2.19 to 0.42), cACT: -0.73 (-2.09 to 0.62), or combined ACT and cACT (P = .10), and was within the predefined statistical clinical equivalence. The proportion with an exacerbation and measures of lung function were similar between groups. Compared with PBA, SBA led to less beclomethasone use (SBA: 526 µg/mo [95% CI, 412-639 µg] vs PBA: 1961 µg/mo [95% CI, 1681-2241]; P < .0001). More parents in the SBA arm felt they were managing their child's asthma. CONCLUSIONS: SBA in African-American children with mild asthma was similar to PBA in asthma control and events when implemented by PCPs with lower inhaled corticosteroid exposure.


Asunto(s)
Antiasmáticos , Asma , Administración por Inhalación , Adolescente , Corticoesteroides/uso terapéutico , Negro o Afroamericano , Antiasmáticos/uso terapéutico , Asma/tratamiento farmacológico , Asma/epidemiología , Niño , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...