Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomed Chromatogr ; 22(1): 58-63, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17642067

RESUMEN

A sensitive and specific liquid chromatography-positive electrospray ionization-tandem mass spectrometry method has been developed and validated for the determination of glimepiride (GPD) in human plasma. GPD and the internal standard (IS, glibenclamide) were extracted from a small aliquot of human plasma (200 microL) by a simple liquid-liquid extraction technique using ethyl acetate as extraction solvent. The compounds were separated on a YMC Propack, C18, 4.6x50 mm column using a mixture of ammonium acetate buffer, acetonitrile and methanol (30:60:10, v/v) as mobile phase at 0.5 mL/min on an API 4000 Sciex mass spectrometer connected to an Agilent HPLC system. Method validation and pre-clinical sample analysis was performed as per FDA guidelines and the results met the acceptance criteria. GPD and IS were detected without any interference from human plasma matrix. The method was proved to be accurate and precise at linearity range of 0.02-100.00 ng/mL with a correlation coefficient of 0.999. The method was robust with a lower limit of quantitation of 0.02 ng/mL. Intra- and inter-day accuracies for GPD were 88.60-113.50 and 96.82-103.93%, respectively. The inter-day precision was better than 12.21%. This method enabled faster and reliable determination of GPD in a pre-clinical study.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Hipoglucemiantes/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Compuestos de Sulfonilurea/sangre , Espectrometría de Masas en Tándem/métodos , Acetatos/química , Acetonitrilos/química , Administración Oral , Animales , Fraccionamiento Químico/métodos , Cromatografía Líquida de Alta Presión/instrumentación , Gliburida/normas , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/farmacocinética , Masculino , Metanol/química , Estructura Molecular , Ratas , Ratas Wistar , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Compuestos de Sulfonilurea/administración & dosificación , Compuestos de Sulfonilurea/farmacocinética , Espectrometría de Masas en Tándem/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...