Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
ASAIO J ; 52(5): 598-600, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16966867

RESUMEN

In many U.S. hospitals, mechanical circulatory support has become routine. However, catastrophes such as Hurricane Katrina test the abilities of a hospital system to sustain patients on such support and transport them in emergent situations. A 15-year-old boy with dilated cardiomyopathy who was receiving biventricular mechanical circulatory support at a New Orleans hospital was successfully transported by Angel One Transport from Arkansas Children's Hospital across state lines to Texas Children's Hospital, where he was stabilized and received an orthotopic heart transplant.


Asunto(s)
Desastres , Corazón Auxiliar , Transporte de Pacientes/métodos , Adolescente , Trasplante de Corazón , Humanos , Masculino , Transferencia de Pacientes
2.
Perfusion ; 20(3): 135-8, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-16038384

RESUMEN

UNLABELLED: The objective of this study was to investigate the effects of two hollow-fiber membrane oxygenators, the Capiox SX10 and the Lilliput 901, on pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass (CPB) in neonates. METHODS: Twenty-six congenital heart surgery patients (n = 13 in each group) with a mean weight of 3 kg were included in this study. Pressure drops of the membranes, pre- and post-oxygenator extracorporeal circuit pressures (ECC) were recorded during normothermic CPB, hypothermic CPB (20 degrees C) and after rewarming. There were no differences between the groups in mean arterial pressure, pump flow rate, temperature, duration of CPB, crossclamp time or the severity of the surgical repairs. RESULTS: Pressure drop of the Capiox SX10 oxygenator was significantly lower during normothermic (32 +/- 10 versus 55 +/- 16 mmHg, p < 0.001), hypothermic (38 +/- 15 versus 72 +/- 18 mmHg, p < 0.001) and post-rewarming (42 +/- 13 versus 72 +/- 21 mmHg, p < 0.001) periods compared to the Lilliput oxygenator. In the Capiox group, the pre-oxygenator ECC pressure was also significantly lower during normothermic CPB (142 +/- 27 versus 184 +/- 43 mmHg, p < 0.01), hypothermic CPB (162 +/- 30 versus 199 +/- 38 mmHg, p < 0.01) and after rewarming periods (172 +/- 32 versus 212 +/- 42 mmHg, p < 0.01). Post-oxygenator pressures in the Capiox group were also lower than in the Lilliput group, but results were not statistically significant. CONCLUSIONS: These results suggest that the Capiox SX10 hollow-fiber membrane oxygenator produced significantly lower membrane pressure drops and pre- and post-oxygenator ECC during normothermic and hypothermic CPB. Thus, blood trauma with the Capiox during extracorporeal circulation may be significantly lower compared to the Lilliput. Further studies, including the level of complements, platelets, neutrophils and cytokines, with these oxygenators are warranted.


Asunto(s)
Presión Sanguínea/fisiología , Puente Cardiopulmonar/instrumentación , Cardiopatías Congénitas/cirugía , Hipotermia Inducida , Membranas Artificiales , Oxigenadores de Membrana/estadística & datos numéricos , Velocidad del Flujo Sanguíneo , Diseño de Equipo , Humanos , Recién Nacido , Oxigenadores de Membrana/efectos adversos , Tasa de Supervivencia
3.
Artif Organs ; 28(10): 963-6, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15385006

RESUMEN

The objective of this study was to investigate the outcomes of children with heart failure of various etiologies requiring temporary use of currently available technology in the U.S.A. after extracorporeal life support (ECLS) [left ventricular assist device (LVAD) or extracorporeal membrane oxygenation (ECMO)] at Texas Children's Hospital. Between July of 1995 and October of 2002, 2847 patients underwent congenital heart surgical repairs with the aid of cardiopulmonary bypass at Texas Children's Hospital. During this period, 17 patients required chronic mechanical circulatory assistance with Biomedicus centrifugal pump (n=8) or Thoratec LVAD (n=4), and ECMO (n=5). Six out of 17 patients required ECLS for postcardiotomy heart failure. Seven of the 17 patients had congenital heart disease, six had cardiomyopathy, three had late acute rejection following heart transplantation, and one had myocardial infarction. Twelve patients survived and five patients expired. Six of 12 survivors recovered sufficient cardiac function to allow device removal; and the remaining six patients underwent heart transplantation. Three out of five deaths were ECMO patients. The need for ECLS following repair of congenital heart disease is extremely rare in our institution. The requirement for the use of ECMO confers a significantly higher mortality presumably because of associated combined cardiopulmonary failure. Congenital heart disease appears to be associated with significantly higher mortality.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Cardiopatías Congénitas/cirugía , Corazón Auxiliar , Adolescente , Adulto , Puente Cardiopulmonar , Niño , Preescolar , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/terapia , Hospitales Pediátricos , Humanos , Lactante , Recién Nacido , Tasa de Supervivencia , Texas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...