Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Contact Dermatitis ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38602297

RESUMEN

BACKGROUND: Allergic contact dermatitis (ACD) from rubber glove usage is usually caused by rubber additives such as the accelerators. However, in analyses of the suspected gloves, ordinary rubber allergens are not always found. Accelerator-free rubber gloves are available, but some patients with accelerator allergy do not tolerate them and might also be patch test positive to them. OBJECTIVES: To identify and chemically characterize a new allergen, 2-cyanoethyl dimethyldithiocarbamate (CEDMC), in rubber gloves. We describe two patient cases: patient 1 that led us to the identification of CEDMC and patient 2 with occupational ACD caused by CEDMC. METHODS: The patients were examined with patch testing including baseline and rubber series, and their own rubber gloves. High-performance liquid chromatography (HPLC) was used for chemical analysis of rubber gloves. The allergen was synthesized and identified by nuclear magnetic resonance, mass spectrometry and infrared spectrometry, and tested on patient 2. RESULTS: CEDMC was identified by HPLC in a nitrile glove associated with hand eczema in patient 1. Patient 2 whose nitrile gloves contained CEDMC was patch test positive to CEDMC. CONCLUSIONS: CEDMC is a new contact allergen in nitrile gloves and probably forms during vulcanization from residual monomer acrylonitrile and rubber additives.

3.
Acta Derm Venereol ; 104: adv19676, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38551376

RESUMEN

Allergic contact dermatitis is reported among individuals using continuous glucose monitoring systems and insulin pumps. The aim of this study was to describe contact allergy patterns for allergens in the Swedish baseline series and medical device-related allergens among users. Contact allergy to baseline series allergens and isobornyl acrylate was compared between diabetes patients and dermatitis patients patch-tested at the Department of Occupational and Environmental Dermatology during 2017 to 2020. Fifty- four diabetes patients and 2,567 dermatitis patients were included. The prevalence of contact allergy to fragrance mix II and sesquiterpene lactone mix was significantly higher in diabetes patients compared with dermatitis patients. Of the diabetes patients 13.0% and of the dermatitis patients 0.5% tested positive to sesquiterpene lactone mix (p < 0.001). Of the diabetes patients 7.4% and of the dermatitis patients 2.3% tested positive to fragrance mix II (p = 0.041). Of the diabetes patients 70.4% tested positive to medical device-related allergens. Of the diabetes patients 63.0% and of the dermatitis patients 0.2% were allergic to isobornyl acrylate (p < 0.001). In conclusion, not only medical device-related contact allergies, but also contact allergy to baseline series allergens (fragrance mix II and sesquiterpene lactone mix), is overrepresented in diabetes patients who use medical devices.


Asunto(s)
Acrilatos , Canfanos , Dermatitis Alérgica por Contacto , Diabetes Mellitus , Sesquiterpenos , Humanos , Alérgenos/efectos adversos , Estudios Retrospectivos , Suecia/epidemiología , Automonitorización de la Glucosa Sanguínea , Glucemia , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Diabetes Mellitus/inducido químicamente , Pruebas del Parche , Lactonas
4.
Contact Dermatitis ; 90(5): 495-500, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38316128

RESUMEN

BACKGROUND: Allergic contact dermatitis (ACD) has been reported as an adverse effect from the use of several glucose sensors and insulin pumps from different manufacturers. Isobornyl acrylate (IBOA) has been identified as a major culprit sensitizer, but also other acrylates and (modified) colophonium have been reported as causes of ACD. OBJECTIVES: To report the two first cases diagnosed with ACD caused by the Dexcom G7 (DG7) glucose sensor. PATIENTS AND METHODS: Two children with suspected ACD from DG7 were patch tested with our medical device series with an addition of selected test preparations including two variants of modified colophonium - methyl hydrogenated rosinate (MHR) and glyceryl hydrogenated rosinate (GHR). Both patients were also tested with acetone extracts made from different parts of the DG7 sensor. The extracts were analysed by gas chromatography-mass spectrometry (GC-MS). RESULTS: Both patients tested positive to IBOA, hydroabietyl alcohol and GHR. In addition, patient 1 had a positive reaction to MHR and patient 2 had a positive reaction to colophonium. The GC-MS analyses showed the presence of IBOA and colophonium-related substances in the DG7 extracts. CONCLUSIONS: Both patients were diagnosed with contact allergy to well-known medical device-related sensitizers. The presence of IBOA and (modified) colophonium in a newly introduced (on the Swedish market in 2023) glucose sensor is remarkable and indicates an inadequate toxicological assessment of the materials used in the sensor.


Asunto(s)
Alérgenos , Canfanos , Dermatitis Alérgica por Contacto , Niño , Humanos , Alérgenos/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Automonitorización de la Glucosa Sanguínea/efectos adversos , Adhesivos/efectos adversos , Acrilatos/efectos adversos , Glucosa , Pruebas del Parche/efectos adversos
5.
Contact Dermatitis ; 90(5): 501-506, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38332444

RESUMEN

BACKGROUND: Many people live with ostomies after life-saving surgery. Ostomy patients often suffer from peristomal dermatitis. Allergic contact dermatitis (ACD) has been reported, mostly due to contact allergy (CA) to topical agents. OBJECTIVES: We present three patients with therapy resistant peristomal dermatitis, suggesting ACD caused by different stoma products. METHODS: Patch testing was performed with baseline series, additional series, and selected allergens. They were also tested with their own ostomy products as is and separate extracts of the products. Extracts were analysed using Gas Chromatography-Mass Spectrometry (GC-MS). RESULTS: In all three patients we diagnosed CA to 1,6-hexanediol diacrylate (HDDA), +++ in case (C) 1 and 3, ++ in C 2. HDDA was detected in C 2's ostomy pouch adhesive and in C 1's and 3's flange extenders used to improve the adhesion of the ostomy pouches. CONCLUSION: Therapy resistant peristomal dermatitis should always be suspected of ACD and patch testing, especially with the patient's own products, should be performed.


Asunto(s)
Dermatitis Alérgica por Contacto , Estomía , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Estomía/efectos adversos , Acrilatos/efectos adversos , Alérgenos/efectos adversos , Pruebas del Parche/métodos
6.
Contact Dermatitis ; 90(6): 566-573, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38387040

RESUMEN

BACKGROUND: Quantitative risk assessment (QRA) for skin sensitization is used to derive safe use levels of sensitising fragrance ingredients in products. Post-marketing surveillance of the prevalence of contact allergy to these ingredients provides relevant data to help evaluate the performance of these measures. OBJECTIVES: To determine a suitable patch test concentration for five fragrance materials that had hitherto not been tested on a regular basis. These concentrations are then to be used in a surveillance study with patch testing consecutive patients over an extended monitoring period. MATERIALS AND METHODS: Furaneol, CAS.3658-77-3; trans-2-hexenal, CAS.6728-26-3; 4,8-dimethyl-4,9-decadienal, CAS.71077-31-1; longifolene, CAS.475-20-7; benzaldehyde, CAS.10052-7, were patch tested with other fragrance allergens in four clinics. Patch testing was conducted in three rounds, starting with the lowest concentrations of the five ingredients. The doses were increased in the subsequent rounds if no late-appearing positive reactions and virtually no irritant reactions were reported. RESULTS: Overall, 373 patients were tested. No positive allergic reaction was reported to the five ingredients. Patch test results of other fragrance allergens are reported. CONCLUSIONS: The highest test concentrations are each considered safe for patch testing consecutive patients. Further surveillance based on these preparations will evaluate the hypothesis that QRA-driven consumer product levels of these fragrances can prevent sensitization.


Asunto(s)
Alérgenos , Dermatitis Alérgica por Contacto , Pruebas del Parche , Perfumes , Humanos , Pruebas del Parche/métodos , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/diagnóstico , Perfumes/efectos adversos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Alérgenos/efectos adversos , Alérgenos/administración & dosificación , Anciano , Medición de Riesgo , Adulto Joven , Adolescente , Vigilancia de Productos Comercializados
7.
Dermatitis ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38386591

RESUMEN

Background: Increasing trends of oxidized linalool contact allergy have been reported. However, the impact of reactivity and dose in eliciting allergic contact dermatitis caused by linalool hydroperoxides is insufficiently investigated. Objectives: To perform repeated open application tests (ROATs) using the real-world concentrations of linalool hydroperoxides in patients and control participants. Materials and Methods: Patients who previously had a positive (patients) and a negative (controls) patch test reaction to linalool hydroperoxides 1.0% in petrolatum were patch tested with a dilution series of linalool hydroperoxides preparations and asked to perform ROAT twice daily with 3 concentrations of linalool hydroperoxides creams and a negative control cream for 28 days. The creams contain 44, 140, and 440 PPM of linalool hydroperoxides, representing real-world doses reported in consumer products. Results: Of all 47 participants, 31 were linalool hydroperoxides contact allergy patients, and 16 were controls. One patient had a positive ROAT reaction in the area where cream at the highest concentration of linalool hydroperoxides was applied for 28 days. Conclusions: Repeated exposure to creams containing linalool hydroperoxides at real-life concentrations could rarely elicit an allergic reaction on intact skin after 4 weeks.

8.
Contact Dermatitis ; 90(2): 134-142, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37852634

RESUMEN

BACKGROUND: Contact allergy rates of linalool and limonene hydroperoxides (HPs) have increased. OBJECTIVES: To demonstrate the patterns of simultaneous positive patch test (PT) reactions and prevalences of multiple contact allergies (MCAs) in patients with contact allergy to linalool and/or limonene HPs. METHODS: A retrospective analysis of consecutive dermatitis patients in 2015-2020 was performed. RESULTS: Of all 4192 patients, 1851 had at least one positive PT reaction. Of these, 410 (22.2%) had MCAs, significantly related to a higher age (p-value = 0.003). Patients with an exclusively positive reaction to linalool HPs but not limonene HPs were shown to have MCAs (p-value <0.001, odds ratio (95% confidence interval) = 4.15 (3.01-5.73)). Patients with simultaneous contact allergies to both linalool and limonene HPs had contact allergies to many other screening and fragrance allergens. CONCLUSIONS: Simultaneous positive PT reactions to allergens in baseline series and fragrances are common in patients with the HPs contact allergy, especially linalool HPs. The pattern of simultaneous PT reactions principally suggested the co-sensitization of the cosmetic allergens.


Asunto(s)
Monoterpenos Acíclicos , Dermatitis Alérgica por Contacto , Perfumes , Humanos , Limoneno/efectos adversos , Monoterpenos/efectos adversos , Terpenos/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Estudios Retrospectivos , Ciclohexenos/efectos adversos , Alérgenos/efectos adversos , Peróxido de Hidrógeno/efectos adversos , Perfumes/efectos adversos , Pruebas del Parche
10.
Contact Dermatitis ; 90(1): 79-83, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37840237

RESUMEN

BACKGROUND: Simultaneous overrepresentations of contact allergies and photocontact allergies are common in individuals with photocontact allergy to ketoprofen. AIMS: To investigate whether contact allergy to oxidised (ox.) geraniol, geraniol, geranial, neral and citral is overrepresented in individuals with photocontact allergy to ketoprofen. METHODS: The contact allergy rates to ox. geraniol, geraniol, geranial, neral and citral in routinely patch tested dermatitis patients were compared with the corresponding rates in individuals with photocontact allergy to ketoprofen. RESULTS: Allergic patch test reactions were noted to ox. geraniol 11% (n = 39, 5.8%), ox. geraniol 6% (n = 12, 1.8%), geraniol 6% (n = 2, 0.3%), geranial (n = 18, 2.7%), neral (n = 7, 1.0%) and citral (n = 15, 2.2%). In those four patients who were diagnosed with photocontact allergy to ketoprofen during the test period, a significant overrepresentation (p = 0.020) of simultaneous contact allergy to ox. geraniol 11% was demonstrated. Overrepresentation of simultaneous contact allergy to various combinations of ox. geraniol, ox. limonene and ox. linalool was also noted in ketoprofen-photoallergic patients. CONCLUSIONS: Contact allergy to ox. geraniol, geranial and citral is common in routinely tested dermatitis patients. There is an overrepresentation of simultaneous contact allergy to ox. geraniol, ox. limonene and ox. linalool in patients with photocontact allergy to ketoprofen.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Fotoalérgica , Cetoprofeno , Humanos , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/diagnóstico , Cetoprofeno/efectos adversos , Limoneno , Dermatitis Fotoalérgica/epidemiología , Dermatitis Fotoalérgica/etiología , Pruebas del Parche
11.
Contact Dermatitis ; 90(1): 74-78, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37915267

RESUMEN

BACKGROUND: Contact allergy to the mint-tasting flavour carvone has been observed in patients with oral lichenoid lesions (OLL). Mint-flavoured products such as toothpaste frequently contain carvone. Snuff is a smokeless tobacco product that is chewed or placed in the mouth rather than smoked. In Sweden, the use of snuff and its flavoured versions is extremely common. OBJECTIVES: To investigate whether the consumption of mint-flavoured snuff is associated with contact allergy to carvone and subsequently plays a role in the aetiology of OLL. METHODS: Regarding the two patients, patch testing with snuff pouches was performed. High-performance liquid chromatography and gas chromatography-mass spectrometry analysis were used for identification of carvone in different snuff samples. RESULTS: Two patients with OLL were contacted allergic to carvone when patch tested. Both were using mint-flavoured snuffs several hours a day for many years. One patient was contacted allergic to the snuff pouch tested as is. Carvone was detected in the snuff samples of both patients. CONCLUSIONS: The patients were recommended to avoid the use of mint-flavoured snuffs, toothpaste and foodstuffs. At follow-up 3 months later, the patients had a dramatic clinical improvement of the OLL and oral symptoms. Exposure to mint-flavoured snuffs can be overlooked as a possible aggravating/provoking factor in OLL.


Asunto(s)
Dermatitis Alérgica por Contacto , Tabaco sin Humo , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Tabaco sin Humo/efectos adversos , Pastas de Dientes , Monoterpenos Ciclohexánicos
12.
Acta Derm Venereol ; 103: adv22336, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38078690

RESUMEN

Fibromyalgia is a common chronic pain condition. Rates of contact allergy in individuals with fibromyalgia have not been widely studied. Systemic contact allergy can present with muscle and joint pain and general malaise. The aim of this study is to investigate contact allergy rates in individuals with fibromyalgia to the sensitizers in an extended dental series and compare with control groups. Contact allergy to gold was significantly more common in the fibromyalgia group than the dermatitis control group. When corrected for patch test system, contact allergy to gold was significantly more common in the fibromyalgia group than the dental control group. Contact allergy to hydroxyethyl methacrylate and grouped acrylates and methacrylates was significantly more common in the fibromyalgia group than the dental control group. In conclusion, individuals with fibromyalgia may have a propensity to sensitization to gold, either via an increased exposure or an alteration in the oral environment. Gold is also implicated in systemic contact dermatitis and may be a factor in elicitation of symptoms in individuals with fibromyalgia. Acrylate allergy is also common in the fibromyalgia population and may be a consequence of occupational exposure or dental treatment.


Asunto(s)
Dolor Crónico , Dermatitis Alérgica por Contacto , Dermatitis Profesional , Fibromialgia , Humanos , Dermatitis Profesional/diagnóstico , Dermatitis Profesional/epidemiología , Alérgenos , Pruebas del Parche , Oro/efectos adversos , Fibromialgia/diagnóstico , Fibromialgia/epidemiología , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Acrilatos/efectos adversos , Metacrilatos/efectos adversos
13.
Acta Derm Venereol ; 103: adv18428, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38059803

RESUMEN

Medical adhesive tapes are commonly recommended for the prevention of friction blisters during hiking and military marches. The aim of this paper is to report on the results of investigations into an outbreak of tape-related foot dermatitis in 26 military conscripts following continuous use of medical adhesive tapes for several days during a field exercise. Patch tests were performed using baseline series and aimed testing was performed with colophonium-related substances and different medical adhesive tapes. Contact allergy to the adhesive tapes used was found in 20 (77%) subjects, and contact allergy to colophonium in 16 (61%). Chemical analysis detected colophonium-related substances in the culprit tapes. Compared with consecutive dermatitis patients investigated at our Department of Occupational and Environmental Dermatology in the previous 10 years, conscripts with colophonium allergy had increased odds ratios for concomitant contact allergy to phenol formaldehyde resins and fragrance substances including hydroperoxides of limonene and linalool. The results show that prolonged use of medical adhesive tapes on intact skin carries a high risk for allergic contact dermatitis. Prior to their introduction on the market, medical devices should be assessed for possible side-effects.


Asunto(s)
Dermatitis Alérgica por Contacto , Personal Militar , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Resinas de Plantas/efectos adversos , Pruebas del Parche/métodos , Alérgenos/efectos adversos
17.
Contact Dermatitis ; 89(2): 95-102, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37218587

RESUMEN

BACKGROUND: Eugenol is a known contact sensitiser included in fragrance mix I. OBJECTIVE: To assess the allergic reactivity to eugenol in different concentrations using patch test as well as repeated open application test (ROAT). METHODS: Overall 67 subjects from 6 European dermatology clinics participated in the study. The ROAT was performed for 21 days twice a day, applying 3 dilutions of eugenol (2.7%-0.5%) and a control. Before and after the ROAT, patch testing with 17 dilutions of eugenol (2.0%-0.00006%) and controls was performed. RESULTS: Out of the 34 subjects with contact allergy to eugenol, 21 (61.8%) showed a positive patch test before ROAT was performed, the lowest positive concentration was 0.031%. The ROAT was positive in 19 (55.9%) of the 34 subjects, the time until a positive reaction occurred was negatively associated with the concentration of the ROAT solution, as well as with the allergic reactivity of the subjects as defined by patch testing. In the patch test after ROAT, 20 of the 34 test subjects (58.8%) showed a positive reaction. In 13 (38.2%) of the 34 test subjects, the patch test result was not reproduceable, still 4 (31.0%) of these 13 subjects developed a positive ROAT. CONCLUSION: Eugenol can provoke a positive patch test reaction in a very low dose; besides, this hypersensitivity may persist even if a former positive patch test is not reproduceable.


Asunto(s)
Dermatitis Alérgica por Contacto , Perfumes , Humanos , Eugenol/efectos adversos , Pruebas del Parche , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Alérgenos/efectos adversos , Perfumes/efectos adversos , Relación Dosis-Respuesta a Droga
18.
Contact Dermatitis ; 89(1): 16-19, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37072615

RESUMEN

BACKGROUND: During the COVID-19 pandemic, the use of face masks has increased among healthcare workers (HCWs). Questionnaire studies have shown a high frequency of self-reported facial adverse skin reactions. Case reports have been published on face mask-induced allergic contact dermatitis and urticaria. OBJECTIVES: To describe the results of the contact allergy investigations in consecutive HCWs investigated for skin reactions to face masks during the COVID-19 pandemic and the results of the chemical investigations of face masks supplied by the hospital. METHODS: Participants were patch tested with baseline series and chemicals previously reported in face masks not included in the baseline series. Face mask(s) brought by the HCW were tested as is and/or in acetone extract. Chemical analyses were performed on nine different face masks for potential allergens. RESULTS: Fifty-eight HCWs were investigated. No contact allergies were found to the face mask(s) tested. Eczema was the most common type of skin reaction, followed by an acneiform reaction. Colophonium-related substances were found in one respirator and 2,6-di-t-butyl-4-methylphenol (BHT) were found in two respirators. CONCLUSION: Based on this report, contact allergies to face masks is uncommon. Patch test with colophonium-related substances and BHT should be considered when investigating adverse skin reactions to face masks.


Asunto(s)
COVID-19 , Dermatitis Alérgica por Contacto , Dermatitis Profesional , Dermatosis Facial , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/diagnóstico , Dermatitis Profesional/epidemiología , Dermatitis Profesional/etiología , Pandemias , Máscaras/efectos adversos , COVID-19/epidemiología , COVID-19/prevención & control , Pruebas del Parche/métodos , Dermatosis Facial/epidemiología , Dermatosis Facial/etiología , Personal de Salud
19.
Dermatitis ; 34(4): 323-328, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37001151

RESUMEN

Background: Allergic contact dermatitis (ACD) caused by hexavalent chromium (Cr(VI)) is often severe and difficult to treat. The content of Cr(VI) in cement can be reduced by, for example, addition of iron(II) sulfate. Since 2005 the content of Cr(VI) in cement is regulated in the EU Directive 2003/53/EC and must not exceed 2 ppm. Since this regulation came into force, ACD caused by cement has markedly been reduced. Objective: To investigate Cr(VI) and total chromium content in samples of cement from countries within and outside the EU. Methods: The members of the International Contact Dermatitis Research Group (ICDRG) were invited to participate in the study with the aim to collect cement samples from geographically different areas. The content of Cr(VI) in the samples was estimated by the diphenyl carbazide spot test, atomic absorption spectroscopy was used to assess the total chromium content. Results: Forty-five cement samples were analyzed, containing amounts of Cr(VI) from <0.1 to >70 ppm. Twenty-one samples contained >2 ppm Cr(VI), 24 contained less. Four of 17 samples from within the EU contained >2 ppm Cr(VI), that is, higher amounts than stipulated in the EU directive, as compared with 17 samples from countries outside the EU. Conclusion: In countries outside the EU, significantly more cement samples contained >2 ppm Cr(VI).


Asunto(s)
Cromo , Dermatitis Alérgica por Contacto , Humanos , Cromo/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Cementos para Huesos
20.
Contact Dermatitis ; 88(6): 472-479, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36975130

RESUMEN

BACKGROUND: The two dialkylthiocarbamyl benzothiazole sulphides, dimethyl-thiocarbamylbenzothiazole sulphide (DMTBS) and diethylthio-carbamylbenzothiazole sulphide (DETBS) were shown to be good markers of both thiuram and mercaptobenzothiazole sensitivity. OBJECTIVES: To investigate if DMTBS and/or DETBS could be better markers of contact allergy to common rubber additives than the ones currently used. METHODS: Sixty-eight dermatitis patients were patch tested with DMTBS and DETBS, both at 1% in petrolatum (pet). Because of late reactions in 10 patients, these were retested to DMTBS and DETBS in serial dilutions. Tetramethylthiuram monosulphide (TMTM) 1.0% pet was also tested. RESULTS: At the initial reading Days 3 and 7, no reactions were noted to DMTBS or DETBS. At retesting, 10 of the 68 (15%) patients reacted positively to lower concentrations of DMTBS than the initial test concentration. Seven of 8 also reacted to TMTM. Three of them had positive reactions to DEBTS. All 10 patients had reactions to more diluted solutions to DMBTS than to DEBTS (p = 0.0077; Mc-Nemar test, two-sided). CONCLUSIONS: Results speak for patch test sensitization to DMTBS with cross-reactivity to TMTM and also DEBTS. DMTBS and DEBTS could be new markers of rubber allergy but a safe test concentration must be found.


Asunto(s)
Dermatitis Alérgica por Contacto , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Goma/efectos adversos , Alérgenos/efectos adversos , Pruebas del Parche/efectos adversos , Sulfuros/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...