Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 13(1): 3385, 2022 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-35697674

RESUMEN

Extremely rare circulating tumor cell (CTC) clusters are both increasingly appreciated as highly metastatic precursors and virtually unexplored. Technologies are primarily designed to detect single CTCs and often fail to account for the fragility of clusters or to leverage cluster-specific markers for higher sensitivity. Meanwhile, the few technologies targeting CTC clusters lack scalability. Here, we introduce the Cluster-Wells, which combines the speed and practicality of membrane filtration with the sensitive and deterministic screening afforded by microfluidic chips. The >100,000 microwells in the Cluster-Wells physically arrest CTC clusters in unprocessed whole blood, gently isolating virtually all clusters at a throughput of >25 mL/h, and allow viable clusters to be retrieved from the device. Using the Cluster-Wells, we isolated CTC clusters ranging from 2 to 100+ cells from prostate and ovarian cancer patients and analyzed a subset using RNA sequencing. Routine isolation of CTC clusters will democratize research on their utility in managing cancer.


Asunto(s)
Células Neoplásicas Circulantes , Humanos , Masculino , Células Neoplásicas Circulantes/patología , Análisis de Secuencia de ARN
2.
Sci Rep ; 11(1): 20583, 2021 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-34663896

RESUMEN

Reliable and routine isolation of circulating tumor cells (CTCs) from peripheral blood would allow effective monitoring of the disease and guide the development of personalized treatments. Negative enrichment of CTCs by depleting normal blood cells ensures against a biased selection of a subpopulation and allows the assay to be applied on different tumor types. Here, we report an additively manufactured microfluidic device that can negatively enrich viable CTCs from clinically-relevant volumes of unmanipulated whole blood samples. Our device depletes nucleated blood cells based on their surface antigens and the smaller anucleated cells based on their size. Enriched CTCs are made available off the device in suspension making our technique compatible with standard immunocytochemical, molecular and functional assays. Our device could achieve a ~ 2.34-log depletion by capturing > 99.5% of white blood cells from 10 mL of whole blood while recovering > 90% of spiked tumor cells. Furthermore, we demonstrated the capability of the device to isolate CTCs from blood samples collected from patients (n = 15) with prostate and pancreatic cancers in a pilot study. A universal CTC assay that can differentiate tumor cells from normal blood cells with the specificity of clinically established membrane antigens yet require no label has the potential to enable routine blood-based tumor biopsies at the point-of-care.


Asunto(s)
Células Neoplásicas Circulantes/metabolismo , Adulto , Anciano , Recuento de Células , Línea Celular Tumoral , Separación Celular/métodos , Femenino , Humanos , Dispositivos Laboratorio en un Chip , Leucocitos/citología , Masculino , Técnicas Analíticas Microfluídicas/instrumentación , Persona de Mediana Edad , Células Neoplásicas Circulantes/patología , Proyectos Piloto , Impresión Tridimensional
3.
Lab Chip ; 19(20): 3427-3437, 2019 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-31553343

RESUMEN

Isolation and analysis of circulating tumor cells (CTCs) from blood samples present exciting opportunities for basic cancer research and personalized treatment of the disease. While microchip-based negative CTC enrichment offers both sensitive microfluidic cell screening and unbiased selection, conventional microchips are inherently limited by their capacity to deplete a large number of normal blood cells. In this paper, we use 3D printing to create a monolithic device that combines immunoaffinity-based microfluidic cell capture and a commercial membrane filter for negative enrichment of CTCs directly from whole blood. In our device, stacked layers of chemically-functionalized microfluidic channels capture millions of white blood cells (WBCs) in parallel without getting saturated and the leuko-depleted blood is post-filtered with a 3 µm-pore size membrane filter to eliminate anucleated blood cells. This hybrid negative enrichment approach facilitated direct extraction of viable CTCs off the chip on a membrane filter for downstream analysis. Immunofluorescence imaging of enriched cells showed ∼90% tumor cell recovery rate from simulated samples spiked with prostate, breast or ovarian cancer cells. We also demonstrated the feasibility of our approach for processing clinical samples by isolating prostate cancer CTCs directly from a 10 mL whole blood sample.


Asunto(s)
Separación Celular/métodos , Células Neoplásicas Circulantes/química , Impresión Tridimensional , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Separación Celular/instrumentación , Humanos , Células Jurkat , Dispositivos Laboratorio en un Chip , Leucocitos/citología , Leucocitos/inmunología , Células Neoplásicas Circulantes/inmunología
4.
Nano Lett ; 17(11): 7110-7116, 2017 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-28967259

RESUMEN

Many regulated epigenetic elements and base lesions found in genomic DNA can both directly impact gene expression and play a role in disease processes. However, due to their noncanonical nature, they are challenging to assess with conventional technologies. Here, we present a new approach for the targeted detection of diverse modified bases in DNA. We first use enzymatic components of the DNA base excision repair pathway to install an individual affinity label at each location of a selected modified base with high yield. We then probe the resulting material with a solid-state nanopore assay capable of discriminating labeled DNA from unlabeled DNA. The technique features exceptional modularity via selection of targeting enzymes, which we establish through the detection of four DNA base elements: uracil, 8-oxoguanine, T:G mismatch, and the methyladenine analog 1,N6-ethenoadenine. Our results demonstrate the potential for a quantitative nanopore assessment of a broad range of base modifications.


Asunto(s)
Técnicas Biosensibles/métodos , Daño del ADN , ADN/análisis , Nanoporos , Neoplasias/genética , Adenina/análogos & derivados , Disparidad de Par Base , ADN/genética , Reparación del ADN , Epigénesis Genética , Guanina/análogos & derivados , Guanina/análisis , Humanos , Modelos Moleculares , Nanoporos/ultraestructura , Nanotecnología/métodos , Uracilo/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...